CONVECTION STEAMER WITH GAS FIRED STEAM BOILER Model

Description

GCX-2

6 pan steamer with 140,000 Btu boiler.

GCX-10

10 pan steamer with 200,000 Btu boiler.

Pan Capacity Per Compartment Model

Pan Depth 1"

2-1/2"

4"

6"

GCX-2

6

3

2

1

GCX-10

10

5

3

2

OPERATION SHALL BE BY: Gas fired steam boiler operating at 9-11 psi. The controls shall be equipped for operation on 115 VAC, 1 phase, 50/60 Hz. Natural gas. L.P. gas. SPECIFICATIONS: , convection Shall be a Solaris Model steamer on a modular gas fired steam boiler base, with stainless steel type 304 exterior and #4 finish. The convection steamer shall have doors with removable inner liner of stainless steel, full perimeter gasket seal, outer shell of one piece all welded stainless steel, positive lock and seal mechanism and a stainless steel drip trough connected to drain to collect x 438 mm) . condensate when doors are opened. (356 Eachmm cooking chamber shall be constructed of all welded type 316 stainless steel, fully insulated and provided with removable stainless steel pan supports. The cooking chamber for models GCX-2 shall be 13.875"W x 10.875"H x 19.875D(352mm x 276mm x 504mm) and the cooking chamber for models GCX-10 shall be 13.875"W x 17.375"H x 19.875D(352mm x 441mm x 504mm). Steamer controls shall be accessible through a fully removable side panel and each compartment shall include a 60 minute mechanical timer with ready and cooking pilot light and shall interrupt steam flow to the chamber when the compartment door is opened during cooking cycle and shall be reactivated when the door is closed. An audible signal which will sound at the end of the cooking cycle. The cabinet base with gas fired boiler and controls shall be provided with full perimeter painted angle frame, reinforced boiler mountings, hinged door(s) with flanged magnetic and bullet feet on the front and adjustable feetlatch on the 6"(152mm) stainless steel legs fitted with adjustable bullet feet rear. Standard boiler controls shall be automatic water level on the front and adjustable flanged feet glass, on thepressure rear for securing control, pressure gauge, water gauge control unit to the floor. Boiler controls shall include automatic water with pressure safety control, safety relief valve and cathodic level control, pressure gauge, water gauge glass, operating protector. pressure control, safety high-limit pressure control, safety relief valve and cathodic protector. The unit shall be ASME code stamped and National Board registered, AGA, CGA and NSF certified. REV 5/08

OPTIONAL ITEMS AT EXTRA COST: 200,000 BTU, 24" or 36" (610mm or 915mm) cabinet.. 250,000 BTU, 36" (915mm) cabinet. 300,000 BTU, 36" (915mm) cabinet. 220 VAC, 1 Phase, 50/60 Hz. Electronic ignition. CSD-1. Automatic boiler blow down. 36" wide cabinet size. Stainless steel rear panel. Stainless steel frame. Split water line. Correctional package. Adjustable front flanged feet. Load compensating timers. ACCESSORIES: Steam take off kit (STOK). De-liming kit (DPA-1)not available with CSD-1. Water in “Y” strainer. Spray and rinse assembly.

Customer Service (570) 497-5477 - Fax (888) 388-6017 - www.solarissteam.com

DETAILS AND DIMENSIONS SERVICE CONNECTIONS ELECTRICAL CONNECTION: 1/2" conduit connection to controls. 120VAC-60Hz-1PH, max. 2 AMPS. DRAIN: 2"IPS piped to open floor drain. No Solid Connection. COLD WATER: 3/8" O.D. tubing at 25-50 PSI(170-345 kPa) GAS CONNECTION: 3/4"IPS supply line required. STEAM TAKE-OFF CONNECTION: 3/4" IPS optional to operate adjacent equipment.

WATER QUALITY STATEMENT Water quality is the major factor affecting the performance of your appliance. If you are unsure of water quality, consult a local water treatment specialist and have the water analyzed. Your water supply must be within these general guidelines: Total dissolved solids Less than 60 PPM Total alkalinity Less than 20 PPM Less than 13 PPM Silica Less than 1.5 PPM Chlorine 7.0-8.5 pH Factor Water which fails to meet these standards should be treated by installation of water conditioner. FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS NOT COVERED UNDER WARRANTY.

MODEL

BTU/HOUR 140,000 200,000 250,000 300,000

GCX-2 GCX-10

GCX-2

SHIPPING WT. (24" CABINET) 630 lbs. [286 kg]

SHIPPING WT. (36" CABINET) 764 lbs. [347 kg]

GCX-10

670 lbs. [304 kg]

840 lbs. [381 kg]

MODEL

GAS SUPPLY

kW/HOUR 41.0 58.6 73.3 87.9

AVAILABLE CABINET WIDTH 36" 24" YES YES YES YES NO YES NO YES

WATER COLUMN PRESSURES NATURAL PROPANE

7" - 14" [178mm-355mm]

11" - 14" [279mm-355mm]

MIN. CLEARANCE SIDES

3 [76]

BACK

6 [152]

2 EQUALLY SPACED Ø7/16" [11mm] HOLES ON 2.5" [63mm] B.C.

3.5 [89]

D S

REAR FLANGED FOOT DETAIL

2.75 [70]

C

5.75 [146]

8 [203] S

33 [838]

2.5 [64]

(36" CABINET)

25 [635]

55.5 [1410] GCX-2

68.5 [1740] GCX-10

9.5 [241]

6.25 [159]

S

16.75 [425]

28 [711]

6 [152]

8.75 [222]

12.5 [318]

14.75 [375]

24 [610]

3 [76]

C D 24 [610]

5.75 [146]

36 [914]

IN [mm] 6376R4