Convotherm Acc 101705.qxd

Cleveland

Item __________________________________ Quantity _______________________________ FCSI Section ____________________________

COMBI OVEN-STEAMER Options & Accessories

Approval _______________________________ Date __________________________________

Kleensteam II

(for Combi's with a Generator, models OEB & OGB): (with Prefilter, two Carbon-Block Cartridges & one Scale Stick Cartridge)

MODEL:

 C9797-K2PF

Cleveland Standard Features : Kleensteam II

I Recommended filter delivering high quality filtered water with

scale inhibition I System includes: one prefilter, two carbon-block cartridges and one scale stick cartridge. I Dual cartridge design provides enhanced performance for low or high flow capacity steamers I 2 five micron carbon block filters improve performance, maximize energy efficiency and increase the life of combi oven steamers I Reduces chlorine-induced corrosion I Long lasting SS-10 cartridge is more effective in higher alkalinity/hardness/TDS/temperature installations. I Sophisticated Hydroblend compound prevents limescale formation in high temperature steam applications I System is simple to install, operate and maintain

Prefilter: I Filters out larger dirt and rust particles I Extends the life of primary filter cartridges I Tightly spun EC210 sediment cartridge delivers 10 micron nominal filtration I Durable slim bowl design makes cartridge change outs easy to handle I Clear housing allows for visually inspection of trapped particles and makes determining when to change the cartridge easy

Prefilter

COMBI OVEN-STEAMER

Project ________________________________



Kleensteam II

Short Form Specifications Shall be Cleveland Model C9797-K2PF Kleensteam II with one prefilter, two carbon-block cartridges and one scale stick cartridge, dual cartridge design for Combi's with a Generator, models OEB & OGB, 2 five micron carbon block filters and SS-10 cartridge for higher alkalinity / hardness / TDS / temperature installations.

Options and Accessories

Ë Replacement Cartridges

SECT.

179 St., St., 1333 East 179

Tel: 1-216-481-4900 1-216-481-4900

Web Site: www.ClevelandRange.com www.ConvothermUSA.com

Cleveland, Ohio, Ohio, U.S.A. U.S.A.44110 44110

Fax: 1-216-481-3782 1-216-481-3782

Email: [email protected] [email protected]

IIB

PAGE

12C 0913

Kleensteam II

(for Combi's with a Generator, models OEB & OGB): (with Prefilter, two Carbon-Block Cartridges & one Scale Stick Cartridge)

20.50” 521mm

5.16” 131mm

Inlet 3/4” FNPT

Outlet to Combi Oven-Steamer

25.50” 521mm

22.44” 570mm

Prefilter

Kleensteam II

Technical Data Overall Dimensions:

25.50”H x 20.50”W x 7.00”D

Inlet Connection:

3/4” FNPT

Outlet Connection:

3/4” FNPT

Service Flow Rate:

Maximum 3.5 gpm (13.2 Lpm) - twin cartridges

Pressure Requirements:

10 - 125 psi (0.7 – 8.6 bar), non-shock

16.50” 521mm

Inlet FNPT Maximum Water Temperature at Inlet:3/4”100°F (38°C)

Alkalinity Range:

2 to 12 grains per gallon

Electrical:

No electrical connection required

Shipping Weight:

34 lbs.

Operating Weight:

42 lbs.

The contaminants or other substances removed or reduced by this drinking water system are not necessarily in your water. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used with disinfected water that may contain filterable cysts. NSF Certified under NSF/ANSI Standard 42 for materials Outlet to Combi Oven-Steamer

25.50” 521mm

NOTES:

Cleveland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Cleveland Range equipment is built to comply with applicable standards for manufacturers.

SECT.

IIB

PAGE

12D 0913

Cleveland

Item __________________________________ Quantity _______________________________ FCSI Section ____________________________

COMBI OVEN-STEAMER Options & Accessories

Approval _______________________________ Date __________________________________

MODEL:

Kleensteam II

(for Boilerless Combi's models OES & OGS): with two Carbon-Block Cartridges (Prefilter not included)

 C9797-40

Cleveland Standard Features : Kleensteam II

I Recommended filter delivering high quality filtered water with scale inhibition I System includes: two carbon-block cartridges.

I Dual cartridge design provides enhanced performance for low or high flow capacity steamers

I 2 five micron carbon block filters improve performance, maximize energy efficiency and increase the life of combi oven steamers I Reduces chlorine-induced corrosion

I Sophisticated Hydroblend compound prevents limescale formation in high temperature steam applications I System is simple to install, operate and maintain

Kleensteam II

Options and Accessories

Ë Prefilter, filters out larger dirt and rust particles (20" clear housing)

Ë Replacement Cartridges

COMBI OVEN-STEAMER

Project ________________________________



Short Form Specifications Shall be Cleveland Model C9797-40 Kleensteam II with two carbonblock cartridges, dual cartridge design for Boilerless Combi's models OEB & OGB.

SECT.

179 St., St., 1333 East 179

Tel: 1-216-481-4900 1-216-481-4900

Web Site: www.ClevelandRange.com www.ConvothermUSA.com

Cleveland, Ohio, Ohio, U.S.A. U.S.A.44110 44110

Fax: 1-216-481-3782 1-216-481-3782

Email: [email protected] [email protected]

IIB

PAGE

12E 0913

Kleensteam II

(for Boilerless Combi's models OES & OGS): with two Carbon-Block Cartridges (Prefilter not included)

16.50” 521mm

Inlet 3/4” FNPT

Outlet to Combi Oven-Steamer

25.50” 521mm

Kleensteam II

Technical Data Overall Dimensions:

25.50”H x 16.50”W x 7.00”D

Inlet Connection:

3/4” FNPT

Outlet Connection:

3/4” FNPT

Service Flow Rate:

Maximum 3.5 gpm (13.2 Lpm) - twin cartridges

Pressure Requirements:

10 - 125 psi (0.7 – 8.6 bar), non-shock

The contaminants or other substances removed or reduced by this drinking water system are not necessarily in your water. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used with disinfected water that may contain filterable cysts. NSF Certified under NSF/ANSI Standard 42 for materials

Maximum Water Temperature at Inlet: 100°F (38°C) Alkalinity Range:

2 to 12 grains per gallon

Electrical:

No electrical connection required

Shipping Weight:

27 lbs.

Operating Weight:

32 lbs.

NOTES:

Cleveland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Cleveland Range equipment is built to comply with applicable standards for manufacturers.

SECT.

IIB

PAGE

13F 0913