cooper lighting - metalux - Cooper Industries

Report 14 Downloads 618 Views
COOPER LIGHTING - METALUX

®

DESCRIPTION

The New Cruze Retrofit Kit is an effective “Energy Savings Alternative” for today’s environmentally conscious marketplace. This retrofit kit system provides customers the opportunity to upgrade their dated louver or lens to a more contemporary center basket lens shielding that is highly efficient, quick to install and fully NEC compliant. The architectural retrofit kit is designed for installation into a 2' x 4' parabolic or troffer.

Type

Catalog # Project

Date

Comments Prepared by

In a marketplace where aesthetics are still critical elements used to convey style, appearance and performance, the Cruze Retrofit Kit is the smart solution for any office, government, educational and retail retrofit kit application whose goal involves energy awareness and conservation without the added renovation and disposal costs. SPECIFICATION FEATURES

Construction

The retrofit kit assembly consists of four components and fits into most parabolics and troffers. Universal brackets are made from code gauge steel and come pre-wired to ballast and sockets. Kits are pre-assembled and ready for quick, easy install right out of the box. A one-piece high reflectance white reflector installs without any hardware, while a die formed doorframe and architectural lens shielding provides the last component of this retrofit system. Minimum housing depth = 3-1/2"

brackets with one hand while driving in screws. No parts bag or extra hardware needed. Electrical

Standard Class “P” electronic ballast with captive hardware for ease of install. Push-in lampholders. UL/cUL Listed. Suitable for damp locations. No junction box required.

H i n g e / L a t ch

Positive spring loaded, self locking, steel latching allows for easy opening and closing of louver or other shielding media. Hinging and latching can be done from either side of the retrofit kit for increased installation flexibility and ease of maintenance. Optics

Door Finish

Cold rolled steel w/multistage iron phosphate pre-treatment for maximum bonding. Highly reflective matte white finish on all reflective surfaces for increased efficiency.

Ready-Set

Pre-installed self-tapping screws easily penetrates existing fixture body and ends. Leveling flange aligns, supports, and holds hardware in place, letting you hold the

Die formed doorframe and architectural center position lens shielding provides a modern architectural appearance similar to the Metalux Ovation. Overall optical efficiency is above 84%. Optional 97% reflective White Optics material is available to help further maximize kit efficiency, distribution, energy savings and payback.

Cruze Retrofit 2x4 232, 228T5 254T5 2 LAMP TROFFER AND PARABOLIC ARCHITECTURAL RETROFIT KIT

Patent Pending

13-1/2" [342mm]

3-1/2" [89mm]

4" [101mm]

RETROFIT COMPATIBILITY

The Cruze retrofit kit was designed to upgrade troffer or parabolic fixtures from all major manufacturers that have the following minimum dimensions: 12-1/4" [311mm] CROSS SECTION 5/8" [16mm]

3-1/2" [89mm]

22-7/16" [569mm] 23-3/4" [603mm] Nominal

ENERGY DATA Input Watts: EB Ballast & STD Lamps 228T8=47 232=55

47-15/16" [1218mm] 47-29/32" [1217mm] Min. End to End

T5 Ballast & STD Lamps 228T5=62 254T5=117

45-3/8" [1153mm] Min. Inside 46-1/2" [1181mm] Min. Inside Opening 47-3/4" [1213mm] Nom. Overall Length

Safe and convenient means of disconnecting power. S

Before ordering refer to these dimensions as a reference or contact your local representative for a trial install prior to ordering large job quantities.

LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS

COOPER LIGHTING

ADF101331

YS

CE

TE MS

RTIFIED

CRUZE RETROFIT 2' x 4'

PHOTOMETRICS

Coefficients of Utilization

ART-2CRZ-232L

Electronic Ballast (2) 32W T8lamps 3100 lumens. Spacing criterion: (II) 1.3 x mounting height, (⊥) 1.3 x mounting height. Efficiency = 85.6%. Test Report: ART-2CRZ-232L.IES

rc rw RCR 0 1 2 3 4 5 6 7 8 9 10

Candela

Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10

20% 50% 50 30 10

30% 50 30 10

10% 50 30 10

0% 0

102 92 83 75 69 63 58 54 50 47 44

95 82 71 62 54 49 44 40 36 33 31

91 79 68 59 52 47 42 38 35 32 30

87 76 65 57 50 45 41 37 34 31 29

86 70 57 47 40 34 29 26 23 20 18

102 88 76 66 58 51 46 42 38 35 32

102 84 69 58 50 43 38 34 30 27 25

102 80 64 52 44 37 32 28 25 22 20

100 90 81 73 67 61 56 52 48 45 42

100 86 74 64 57 50 45 41 37 34 31

100 100 82 79 68 63 57 52 49 43 43 37 38 32 33 28 30 25 27 22 25 20

95 79 66 56 48 42 37 33 30 27 24

95 76 62 51 43 37 32 28 25 22 20

91 76 64 54 47 41 36 32 29 26 24

Zonal Lumen Summary

Luminance Data

Zone 0-30 0-40 0-60 0-90 0-180

Angle In Deg 45 55 65 75 85

Lumens

%Lamp

%Fixture

1267 2105 3896 5305 5305

20.4 33.9 62.8 85.6 85.6

23.9 39.7 73.4 100.0 100.0

Average 0-Deg cd/sm 2484 2458 2387 2169 1822

91 74 60 50 42 36 31 28 25 22 20

87 74 62 53 46 40 35 32 29 26 24

Average 45-Deg cd/sm 2681 2757 2968 3452 1969

87 72 59 49 42 36 31 28 25 22 20

Average 90-Deg cd/sm 2815 3102 3640 2826 1914

Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90

Along II

45°

Across⊥

1607 1593 1569 1533

1607 1599 1582 1552

1607 1602 1590 1569

1485 1425 1357 1277 1191 1095 992 879 759 629 490 350 216 99 1

1513 1465 1407 1342 1266 1182 1088 986 882 782 698 557 265 107 1

1539 1499 1450 1389 1318 1241 1159 1077 1024 959 813 456 265 104 1

LER = FP-82 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $2.93

Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801

8/12

ADF101331

CRUZE RETROFIT 2' x 4'

ORDERING INFORMATION SAMPLE NUMBER: ART-2CRZ-232L-UNV-EB81-10B

Product ART=Advanced Retrofit Technology

Width 2=2' Nominal Series CRZ=Cruze Retrofit Kit

Number of Lamps 2=2 lamps (Not Included)

Wattage (Length) 32=32W T8 (48") 28T5=28W T5 (48") 254T5=54W T5HO (48")

Distribution Blank=White (Medium) WO=White Optics (General)

Voltage (1) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (2) NB=No Ballast Emergency Option EL=Emergency Installed. Low Profile Battery Pack Only. (consult factory)

Shielding L=Acrylic Lens Shield (Standard)

Ballast Type T5 Ballasts EBT =T5 or T5HO Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Standard Ballast Factor=1.0

Packaging 10B=Bulk Pack U=Unit Pack (Consult factory for other packaging options)

Ballast/FactorType

EBT N=T5 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Normal Ballast Factor=.90 EBT H=T5 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. High Ballast Factor=1.15 T8 Ballasts EB8 =T8 Electronic Start. Total Harmonic Distortion < 10% EB8 /PLUS= T8 Electronic Start. Total Harmonic Distortion < 10%. High Ballast Factor > 1.15 ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%

High Performance T8 Ballasts HB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HB8 L=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Low Ballast Factor .77 – .82 HB8 N=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Normal Ballast Factor 1.15 – 1.20 HR8 T8 Electronic Program Rapid (3) Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HR8 DIM=T8 Electronic Program (3) Rapid Start. Total Harmonic Distortion < 10%. Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program (3) Rapid Start. Total Harmonic Distortion < 10%. Low Ballast Factor .71 – .79 HR8 H=T8 Electronic Program (3) Rapid Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 Number of Ballasts 1=1 Ballast 2=2 Ballasts [Blank]=No Ballast (NB Option Only)

(1)

NOTES: Products also available in non-US voltages and frequencies for international markets. motion sensor, daylight harvesting or similar controls.

(2)

Not available when specifying emergencies, voltage must be specific.

(3)

Recommended when using retrofits together with

For complete product data, go to www.metalux-lighting.com. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.

Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801

8/12

ADF101331