CRS-4 - Columbia Lighting

Report 8 Downloads 150 Views
CRS-4

1' × 4', 2' × 4' Cleanroom, Class 1 / 2, 3, 4, or 6-Lamp T5, T5HO, T8 PROJECT INFORMATION Project Name

Type

Catalog No.

Date

CONSTRUCTION

FEATURES • • • • •

Class 1 Cleanroom certified for any application 11/2" T-Bar standard, 1" or 2" optional Anodized extruded aluminum door frame One-piece, 18 gauge stainless or carbon steel doors available Meets Federal Standard No. 209E for Class 1 cleanrooms and ISO 14644-1 Class 6 cleanrooms

FINISH

Heavy duty channel is constructed of die-formed code gauge steel. All holes in housing are completely closed with silicone sealant. Both housing and door frame are sealed with gasketing. Full length steel ballast cover and socket plates completely enclose all wiring. Fixture is designed for installation into either 11⁄2" wide face T-Bar used in clean rooms as standard with 1" or 2" T-Bar as option.

All painted parts are processed with a multi-stage phosphate bonding treatment and finished with a high temperature baked white enamel after fabrication. Internal reflecting parts will have a reflectance of 90%. SHIELDING

Lens is constructed of acrylic material with many pattern and thicknesses available. The door frame is of anodized extruded aluminum material. Also, a one piece 18 gauge stainless steel or carbon steel door is available.

BALLASTS

Energy efficient, thermally protected, automatic resetting, Class P, high power factor, sound rated A, unless otherwise specified. CEE NEMA Premium compliant.

CERTIFICATION

Meets Federal Standard No. 209E for Class 1 cleanrooms and ISO 14644-1 Class 6 cleanrooms. All luminaires are built to UL 1598 standards and bear appropriate UL and cUL or CSA labels. Damp location labeling is standard and Wet Location labeling is an option. Emergency-equipped fixtures labeled UL 924. UL Sanitation Approved.

ELECTRICAL

Standard class “P,” thermally protected, autoresetting HPF ballast, sound rated A. CEE NEMA Premium compliant. All ballast leads extend a minimum of 6" through access location. NEC/CECcompliant ballast disconnect is standard.

ORDERING INFORMATION CRS

EXAMPLE CRS24-332G-FCSA12125-3EU



MODEL



NO. OF LAMPS IN CROSS SECTION

CRS Cleanroom, Class 1

2 3 4 6

SIZE 14 1' × 4' 24 2' × 4'

Two Three Four (2 × 4 only) Six (2 × 4 only)





CEILING TYPE

DOORS

VOLTAGE

G Lay-in Inverted 11/2" Grid F Flange with Wing Hangers S Surface Mount

FA Flush Aluminum FCS Flush One-Piece Carbon Steel Door1 FSS Flush One-Piece Stainless Steel Door1

U 120V-277V 347 347V

LAMP TYPE 28 4', T5: 28 Watt 32 4', T8: 32, 30, 28 or 25 Watt 54 4', T5HO; 54 or 51 Watt (not available in 1' × 4' 3-Lamp)

LENS A12 A12125 A12125M A19 RF12125

Pattern 12 Acrylic Lens Pattern 12 Acrylic Lens, 0.125" Nominal Pattern 12 Acrylic Lens, 0.125" Minimum Pattern 19 Acrylic Lens, 0.156" Nominal Pattern 12 Acrylic Lens, Radio Frequency Suppressed, 0.125" Nominal3 SASRF Surgical Symmetric/Asymmetric Configuration with RFI Grounding Overlay3

OPTIONS 1T 2T GLR RIF EL WL NYC NYCU

1" T-Bar 2" T-Bar Fast Blow Fuse Radio Interference Filter3 4 Emergency Battery Pack Wet Location5 NYC Compliant NYC Compliant, Union Label

BALLAST2 E 3E 4E EP 3EP

Electronic T8, Instant Start 3-Lamp Electronic T8, Instant Start 4-Lamp Electronic T8, Instant Start Electronic T5 or T8, Programmed Start 3-Lamp Electronic T5HO or T8, Programmed Start 4EP 4-Lamp, Electronic T5 (N/A 347V) or T8, Programmed Start

Not available for 11/2" or 2" grid, RF12125 or SASRF lens. Ballasts may not be available in all combinations of lamp/voltage/starting temp/THD shown above. Contact your local Columbia Representative for more details. 3  When using electronic ballasts, Radio Frequency Interference (RFI) cannot be blocked by an RFI filtering lens to the levels specified by MIL std 461. RFI reflected back onto the primary line by the ballast can be blocked by this RFI filter. 4  One per ballast. 5  Not available with emergency battery pack. 1  2 

Page 1/2 Rev. 11/13/15 © 2015 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com

EXTREME ENVIRONMENT / CRS-4

CRS-4

1' × 4', 2' × 4' Cleanroom, Class 1 / 2, 3, 4, or 6-Lamp T5, T5HO, T8

PHOTOMETRIC DATA

Test Lpi62521 Test Date 1/26/05

LUMINAIRE DATA

ZONAL LUMEN SUMMARY Zone

CRS24-432F-FAA12.125-EB8 CRS Cleanroom 2 × 4 4-Lamp with 0.125" A-12 Pattern Acrylic Prismed Lens B432I120RH 0.88 F32T8 2850 111 0º = 90  90º = 90 0º = 0.96  90º = 0.93 Length: 3.79 Width: 1.80 Height: 0.00

Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet

Lumens %Lamp

0-30 0-40 0-60 0-90 0-180

2117 3384 6006 7799 7799

ENERGY DATA

%Fixt.

18.6 29.7 52.7 68.4 68.4

27.1 43.4 77.0 100.0 100.0

INDOOR CANDELA PLOT

RCR

70 74 67 61 56 52 48 44 41 38 36

80 50 30 71 68 62 57 54 48 48 42 43 36 38 32 35 29 32 26 29 24 27 22

10 65 53 44 37 32 28 24 22 20 18

70 72 65 60 54 50 46 43 40 37 35

70 50 30 69 67 60 56 53 48 47 41 42 36 38 32 34 28 31 26 29 23 27 21

10 64 52 43 37 32 28 24 22 20 18

50 66 58 51 45 40 36 33 30 28 26

50 30 64 54 46 40 35 31 28 25 23 21

10 62 51 42 36 31 27 24 22 20 18

68.4%

Luminaire Efficacy Rating (LER) IESNA RP-1-1993 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

62 Noncompliant $3.87 based on 3000 hrs. and $0.08 per KWH

AVG. LUMINANCE (Candela/Sq. M.)

COEFFICIENTS OF UTILIZATION (%) RC RW 1 2 3 4 5 6 7 8 9 10

Total Luminaire Efficiency

Average Luminance Angle

Luminaire

0 0 57 47 39 34 29 25 22 20 18 16

0 30 40 45 50 55 60 65 70 75 80 85

0.0

22.5

45.0

67.5

90.0

5518 3950 3911 3885 3871 3909 3976 3999 3889 3572 2989 2046

5518 3955 3911 3892 3896 3912 3919 3872 3718 3390 2835 1991

5518 3903 3878 3867 3856 3859 3850 3808 3672 3359 2808 1991

5518 3875 3889 3916 3947 3989 4008 3984 3847 3554 3035 2245

5518 3893 3895 3912 3920 3961 4049 4137 4129 3908 3326 2426

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

DIMENSIONAL DATA 48" 39" 48" 39" 24"

12" 7/8" Dia. KO

7/8" Dia. KO

11"

51/2"

65/16"

61/8" CRS24 2LT

51/2"

51/2"

61/8" CRS14 3LT

65/16"

5"

CRS14 2LT 51/2" 23/4"

7/8" Dia. KO

7/8" Dia. KO

5" CRS24 3LT SWW 125/8" 79/16"

51/2" 5"

CRS24 4LT

21/2"

5"

CRS24 6LT SWW

NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. Page 2/2 Rev. 11/13/15 © 2015 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com