CXNsolid - Phocos

Report 3 Downloads 202 Views
CXNsolid (50 A)

Industrial Solar Charge Controller

Powerful. Intelligent. Informative. • Works with 12, 24 or 48 V systems • Backlit LCD display • Two (2) years of system datalogging • Optional USB and RS232 interface (MXI) • Inverter control port for Go Power! GP-ISW series inverters

Powerful solar charge controller for industrial projects

The CXNsolid is a programmable PWM solar charge controller for the toughest industrial applications. At 50A max charge/load current, CXNsolid is suitable for PV systems up to 3.5 kW. CXNsolid can be easily paired with the Go Power! GP-ISW series pure sine wave inverters for full control over all charging and discharging of the battery.

High Powered • Capable of simultaneously controlling 50A of charge current and 50A load current up to +50C • Works in 12, 24, or 48V PV charging systems

Developed for demanding applications • Robust aluminum heat sink for maximum heat dissipation • External battery temperature sensor for high-accuracy temperature compensation

Application Examples • Telecom • Oil and Gas • SCADA • Traffic • Solar Home Systems

Intelligent • Access up to 2 years of system performance data • Fully adjustable load disconnect feature optimizes discharge for desired battery lifespan

www.phocos.com

Phocos North America 325 S Euclid Ave. Suite 101 Tucson, AZ 85719 USA

Tel. +1 (520) 777-7906 Fax +1 (520) 882-3191 www.phocos.com

Technical Data Type

CXNsolid 50

System voltage

12/24/48 V automatic recognition of system voltage

Max. charge/load current

50 A

Float charge

13.8/27.6/55.2 V (77 °F/25 °C)

Main charge

14.4/28.8/57.6 V (77 °F/25 °C), 30 min. (daily)

Boost charge

14.4/28.8/57.6 V (77 °F/25 °C), 2 h Activation: battery voltage < 12.3/24.6/49.2 V

Equalization charge

14.8/29.6/59.2 V (77 °F/25 °C), 2 h Activation: battery voltage < 12.1/24.2/48.4 V

Deep discharge protection

11.00 – 12.02 V/22.00 – 24.04 V/44.00 – 48.08 V by SOC

Load disconnect voltage

11.00 – 12.00 V/22.00 – 24.00 V/44.00 – 48.00 V by voltage

Adaptive

11.00 – 12.20 V/22.00 – 24.40 V/44.00 – 48.80 V

Reconnect level

12.8/25.6 /51.2 V

Overvoltage protection

15.5/31.0/62.0 V

Undervoltage protection

10.5/21.0/42.0 V

Max. panel voltage (overvoltage protection by varistor)

30 V in 12 V; 50 V in 24 V; 100 V in 48 V systems

Temperature compensation (charge voltage)

−25/-50/-100 mV/K at 12/24/48 V

Inverter Control Compatibility

Yes (GP-ISW-700, GP-ISW-1000, GP-ISW-1500, GP-ISW-2000, GP-ISW-3000)

Self-consumption

< 10 mA

Grounding

Negative grounding

Ambient temperature

-4 °F to 122 °F (- 20 °C to + 50 °C)

Max. altitude

13,000 ft (4,000 m) above sea level

Battery type

Lead acid (GEL, AGM, flooded)

Wire cross section

Up to 1-1/0 AWG (50 mm²)

Dimensions (W x H x D)

6.6 x 5.9 x 2.0 in (167 x 150 x 52 mm)

Weight

2.2 lbs (1000 g)

Type of protection

IP20

MXI

CXNsolid TV Inverter

www.phocos.com

Phocos North America 325 S Euclid Ave. Suite 101 Tucson, AZ 85719 USA