Natural slate roof covering Conservation rooflights

***The top or underside of the entire roof structure is to have 9mm ply, or similar to be laid with staggered joint, and nailed to every rafter with 3mm dia. galv round wire nails at max 200mm centres.

Natural slate roof covering

L2 at bearing ends, use 440 x 100 x 215mm mass concrete p/stone 2 no M16 Rag bolts

2/50 x 150mm C24 timber rafters eitherside of dormer window/ rooflight construction bolted together at max 600mm c/c with M12 (gr8.8) bolts

Gable Elevation

timber leadged and braced doors

Front Elevation (Scale 1:100)

(Scale 1:100)

125 x 50mm C16 timber rafters @ max 400c/c

2/50 x 150mm C24 timber rafters eitherside of dormer window/ rooflight construction bolted together at max 600mm c/c with M12 (gr8.8) bolts

SVP

VB - 2/50 x 200mm C24 or 225 x 75mm C24 timber valley beams bolted together with M12 (gr8.8) bolts at max 600mm c/c

DR

VB - 2/50 x 200mm C24 or 225 x 75mm C24 timber valley beams bolted together with M12 (gr8.8) bolts at max 600mm c/c

DR

Storage Area

125 x 50mm C16 timber rafters @ max 400c/c

Dormer roof construction (refer to specification) In-line slate vent for SVP outlet

EXTRACT

tr

R3 - 305 x 165 x 54 UB ridge beam DR

VB

R1

R1

Storage Area

R2 - 200 x 75mm C16 Ridge beam L1

R1 - 254 x 146 x 37 UB cantilever ridge beam

SD

SD

125 x 50mm C16 timber rafters @ max 400c/c

Ridge beam to cantilever over internal blockwork walls and support ridge R4 & Valley beams VB 440 x 100 x 215mm deep mass concrete p/stones with ragbolts (see eng. detail)

L1

Storage Area

R4 - 200 x 100mm Timber ridge beam

DR VB - 2/50 x 200mm C24 or 225 x 75mm C24 timber valley beams bolted together with M12 (gr8.8) bolts at max 600mm c/c

SD

125 x 50mm C16 timber rafters @ max 400c/c

440 x 100 x 215mm mass concrete p/stone 2 no M16 Rag bolts

VB

at bearing ends, use 440 x 100 x 215mm mass concrete p/stone 2 no M16 Rag bolts L2

L2

Rear Elevation (Scale 1:100)

Gable Elevation (Scale 1:100) Ref to Eng design calculations for connection details

Ref to Eng design calculations for connection details

First Floor Plan

(Scale 1:50) ic 110mm dia uPVC foul drain at min fall