D5 Series - HVACQuick

Report 6 Downloads 177 Views
D5 Series BASIC. VARIO. STRONG. SOLAR. An entirely new generation of pumps, with minimum energy consumption, a shaft-less spherical motor and permanent magnet technology

BR-19A

D5 Series

basic. vario. strong. solar. Applications

Speed controller

• D5 pumps (basic, vario, strong and solar) can be used in a wide variety of DC applications where a highly efficient circulation pump is required. • D5 pumps are used in a wide variety of applications such as medical devices, electronics cooling, chillers, laser cooling, RV hot water systems, battery cooling, and fuel cells.

• Easily adjusts by turning a dial in the pump end. It can be adjusted to vary the hydraulic performance and/or the electrical power consumption. • Regardless of the setting, the pump always starts with maximum torque. This ensures a reliable start even at the lowest speed.

Design

• Each pump has an integrated over-temperature safety device that shuts the pumps electronics off when reaching the temperature limit of +203°F. • If the over-temperature safety device is activated the pump will restart automatically after the pump has cooled completely.

• The single moving part in a spherical motor is a hemispherical rotor/impeller unit. The rotor/ impeller rides on an ultra-hard, wear-resistant ceramic ball. • There are no conventional shaft bearings or seals. Eliminating the possibility of bearing-play and a potential leak path. • Provide an exceptionally long service life in excess of 50,000 hours. • Maintenance is not necessary under normal conditions. Even after lengthy shut down periods a reliable start-up is virtually guaranteed. • Parts exposed to the fluid are completely corrosion resistant even with aggressive fluids.

Integrated over-temperature protection

O-ring Rotor/impeller

Pump housing Stator pump motor Screw ring Ceramic bearing ball

Dimensional Drawings D5 Bronze

D5 Plastic D5 810N

Model

Connection

D5 710 B

1/2” female thread

D5 720 B

1/2” sweat

D5 090 B

1/2” sweat union w/check valve

Model

Connection

D5 850 N

1/2” MPT

D5 810 N

1/2” hose barb

D5 790 N

3/4” hose barb

4 3/16” 3/4”

4 3/16” 1/2”

3 1/2”

2 1/4”

2 1/4”

2 3/4”

2 3/4”

5 1/2”

3/4”

3 1/2”

3 1/2”

2 1/2”

D5 790N

1/2”

1/2”

4 3/16” 1/2”

4 3/16”

3”

D5 850N

2 1/4” 4 3/16”

2 1/4”

D5 090B

1/2”

1/2”

2 3/4”

D5 710B/ D5 720B

2 1/4” 4 3/16”

2 1/4” 4 3/16”

Power Consumption

Housing Material

8-25 Volt DC 3-35 Watts, 0.30-1.50 Amps D5 strong: 3-55 Watts, 0.13-2.1 Amps

Bronze

Power Consumption

Housing Material

8-24 Volt DC, 3-35 Watts, 0.30-1.50 Amps D5 strong: 3-55 Watts, 0.13-2.1 Amps

Plastic (Noryl)

Technical Data Motor design Electronically commutated spherical motor with permanent magnet rotor/impeller Voltage 8 - 25 Volt Power consumption See pump curves Current draw D5 basic and vario: 0.25 – 1.46 A D5 strong: 0.13 - 2.1 A Acceptable media Domestic hot water, water/glycol mixtures, other media on request Insulation class IP 42 / Class F Max. system pressure 150 PSI - 1.0 MPa (10 bar) for pumps with brass housings 50 PSI - 0.35 MPa (3.5 bar) for pumps with plastic housing Max. system temperature -10°F to +203°F (-10°C to + 95°C) for pumps with brass housing (non-freezing) +32°F to +140°F (+/- 0°C to + 60°C) for pumps with plastic housing (non-freezing) Weight 1.54 LBS. (0.7 kg) for pumps with brass housing.77 LBS. (0.35 kg) for pumps with plastic housing when using more than 20 % glycol, check pump performance

Note: Pump curves vary depending on pump housing, speed control setting and supply voltage. The D5 Vario will vary based on the speed control setting. The curves in blue 5 4 3 2 1 are for supply voltage range 12-23 volts. For maximum performance for the D5 Vario (shown in yellow), the supply voltage must be 24 volts and speed control setting at maximum. The D5 Basic have a fixed performance curve for a supply voltage range 12-24 volts, the curve is shown as 4 setting of the Vario charts. The D5 Strong will vary based on the supply voltage. The maximum performance is shown in yellow with 24 volts supply and the 12 volts supply performance curve is shown in blue.

D5 Series Pump Curves - Brass 5 24V

8

20

5 4

6 4

15 10

3

2

5

2 1

0 0

1

Head (ft)

25 Watts

Head (ft)

10

2

3 GPM

4

5

6

UCT Curve (Vario)

14 12 10

30

0

30 25 5 24V

8 6 4 2 0

20

5

15

4

10

3

5

2 1

0

Watts

BS and BT Curve (Vario)

12

1

2

3 GPM

4

5

6

0

UCT Curve (Strong)

24V

Watts

Watts

Head (ft)

24V

Head (ft)

BS and BT 1/2” Curve (Strong)

12V

12V

0

1

2

3

GPM

4

5

6

GPM

D5 Series Pump Curves - Plastic ½” Barb Connection (Vario)

5 4

6 4

3

2 0

2 1

0

1

2

3

4

5

6

7

GPM

20 5

10

3

5

2 1

0

1

2

3 GPM

4

5

6

0

Head (ft)

½” Barb Connection (Strong)

Watts Watts

Head (ft)

15

4

¾” Barb and ½” MPT Connection (Strong)

24V

25

5 24V

Watts

8

30

24V

12V

12V

GPM

GPM

Xylem Inc. 3878 S. Willow, Suite 104 Fresno, CA 93725 Tel: (559) 265-4730 (800) 554-6853 Fax: (559) 265-4740 (800) 453-7523 www.xyleminc.com/brands/laingthermotech Laing Thermotech is a trademark of Xylem Inc. or one of its subsidiaries. © 2012 Xylem, Inc. BR-19A November 2012

Watts

5 24V

16 14 12 10 8 6 4 2 0

Watts

Head (ft)

10

Head (ft)

12

40 35 30 25 20 15 10 5 0

Watts

¾” Barb and ½” MPT Connection (Vario) 14