DCS 409R - Dynacord

Report 5 Downloads 88 Views
Dynacord | DCS 409R

DCS 409R www.dynacord.com

▪ 5 low frequency relays, 2 switch contacts each. ▪ Gold-plated double contacts for high level of contact reliability. ▪ Pluggable connection terminals with screwed flange for all contacts. ▪ 5 relay control LEDs.

The module is fitted on the back of the DCS 400 rack plug-in board. This is used to switch audio signals (line levels) or for control outputs. Additional properties: • Configure the audio distributor by separating the wire jumpers • A maximum of 12 DCS 408R/DCS 409R relay modules can be cascaded

Parts included No.

Component

1

DCS 409R

2

Plug, 15-pin (Phoenix MC 1.5/15-STF-3.81 - 1827839)

Technical specifications Operating voltage

24 V DC, -10%/+30%

Operating current, relays off • Standby

24 V, 5.5 mA, 0.14 W

• Idle/Announcement/Alert

24 V, 60 mA, 1.44 W

Electromagnetical environment

E1, E2, E3

Operating temperature

-5 °C to 45 °C

Product dimensions (Width by Height by Depth)

37.5 by 80.6 by 245 mm

Net weight

185 g

Relay contacts • Contacts

2 SPDT

• Contact material

AgPd + 10μ Au

• Contact load (real)

1 A / 24 V DC 0.5 A / 120 V DC

• Contact current max.

2A

2 | DCS 409R

DATA4_A

A1 A3 B18 B16

J1 DATA3_A DATA3

+24V

J2

CLK2 CLK2_A

A2

CLK3 CLK3_A

B17

BR4

BR2

BR1

BR18

BR3

BR17

*RES *RES_A RES_A EN 3_A

A4 A6

EN 2_A

B21

DATA2_A

P/S

ID

+24V

B19

DATA1

A5

CLK1_A

BR7

BR8

BR6

BR5

BR19

EN4

BR20

B20

A7

EN5

A9

EN5_A

B24 +24V

EN6

B22

EN6_A

A8

EN7 EN7_A

B23

BR11

BR12

BR10

BR9

BR21

EN8 EN8_A

BR22

CN to Backplane

EN4_A

A10 A12 RES

B27

+24V

EN 3 EN 2

S/P

DATA2 DATA1_A

B25

Relay Driver

A11 B26

BR15

BR16

BR14 BR13

BR23

+24V

BR24

CLK1

A13 A15 DATA5

B30

DATA5_A

DC

DATA_SEL DATA_SEL_A

+24V

t

DC

+5V

B28 A14

EN1 EN1_A

B29

MON+ MON-

Block diagram

Installation/configuration notes Installation information On the DCS 400 rack plug-in board, slots 1–10 must be occupied in ascending sequence (left to right) without any gaps. Different module types can otherwise be arranged in any sequence. Exception: Slot 1 (far left) must always be occupied with a DCS 801R control module or DCS 405R extension module. When assembling the device and installing the connections, please comply with the standards VDE 0100 and EN 60065. Connector The scope of delivery for the device includes two 15pin connectors. Conductor cross-sections of 0.14 mm² (AWG26) to 1.5 mm² (AWG16) can be used. Recommended connecting cable: flexible CU strand, LiY, 0.75 mm².

Represented by: Germany: EVI Audio GmbH Sachsenring 60 94315 Straubing Germany www.dynacord.com © Bosch Security Systems 2013 | Data subject to change without notice Document Number | Vs1 | 19. Mar 2013

Position of the bridges on the circuit board

Certifications and approvals Status as of November 2012: • • • •

EN EN EN EN

50130-4 54-16 55103-1 55103-2

Ordering information DCS 409R Order number F01U121786