Download PDF - GracePorts

Report 6 Downloads 25 Views
K M 35

Panel Mount Housing Dimensions UL Type 4 - IP65 Ratings

HOUSING/ NEMA CODES

P - B2 M

-

P1 5

- - Uxx

ThruView™ Housings

K M F5 0 M 35 R

POWER OPTIONS CODES

CONNECTOR CODES

EXCEPTION CODES

1........UL Type 1 2 ........UL Type 4X

(Special text, logos, cable lengths, MORE!)

3 .......UL Type 4 (IP-65) (Nema 12/4)

Mounting Housing Dimensions (inches [mm]) Code

B

A C

E

A 2.06K.010 [52.4K.2]

B 1.42K.010 [36.0K.2]

C 2.76K.004 [70.0K.1]

D 1.26K.004 [32.0K.1]

EØ .18+.010 [4.5+.2]

F

5.1

3.36K.010 [85.4K.2]

1.42K.010 [36.0K.2]

4.03K.004 [102.4K.1]

1.26K.004 [32.0K.1]

.18+.010 [4.5+.2]

H

5.9

4.42K.010 [112.4K.2] 1.42K.010 [36.1K.2]

5.12K.004 [130.0K.1]

1.26K.004 [32.0K.1]

.18+.010 [4.5+.2]

K

10.8

3.39K.010 [86.0K.2]

2.91K.010 [74.0K.2]

4.41K.004 [112.0K.1]

2.76K.004 [70.0K.1]

.26+.010 [6.5+.2]

M

13.2

4.80K.010 [122.0K.2] 3.15K.010 [80.0K.2]

5.83K.004 [148.0K.1]

2.76K.004 [70.0K.1]

.26+.010 [6.5+.2]

Overall Housing Dimensions (inches [mm]) Code

B

F G H 3.15 [80.0] 1.72 [43.6] 3.20 [81.2]

B M 35

HOUSING CODE:

D

3.8

Weight (oz)

B

4........UL Type 12 5........UL Type 4X, Type 304 Stainless Steel 6........UL Type 4X, Type 316 Stainless Steel 7........UL Type 7-9 8........UL Type 3R Every Enclosure Type Available

I J K 1.60 [40.7] 4.33 [110.1] .96 [24.4]

LØ N/A

MØ .18K.004 [4.5K.1]

F

4.45 [113.0] 1.72 [43.6] 3.20 [81.2]

1.60 [40.7] 4.87 [123.7] .57 [14.4]

N/A

.18K.004 [4.5K.1]

H

5.51 [140.0] 1.72 [43.6] 3.20 [81.2]

1.60 [40.7] 4.87 [123.7] .57 [14.4]

N/A

.18K.004 [4.5K.1]

K

5.08 [129.0] 3.54 [90.0] 4.79 [121.6] 1.60 [40.7] 8.28 [210.2] .45 [11.4] .45 [11.5] .26K.004 [6.5K.1]

M

6.50 [165.0] 3.78 [96.0] 5.02 [127.6] 1.60 [40.7] 8.52 [216.4] .57 [14.4] .45 [11.5] .26K.004 [6.5K.1]

HOUSING CODE:

HOUSING CODE:

F 35 M

H M 35

Drawings available at www.graceport.com

L

F

M

H

G I

!

HOUSING CODE:

J

K M 35

INSTALLATION

GracePorts® are intended to be mounted in or on an enclosure product. Installation should be performed by a qualified technician and adhere to applicable regulatory codes. These devices are for mounting on the flat surface of enclosures having the same type environmental ratings. All installations: 1) Cut panel opening and mount GracePort® assembly to enclosure with gasket. 2) Connect low voltage interface wiring according to documentation provided with unit. On units configured for optional AC power: 1) Connect outlet device as per code. Note: It is the responsibility of the installer to ensure adequate separation of high and low voltage circuits in the end-use product. 2) Ensure that the metal housing is reliably grounded using grounding means provided.

K

SPECIFICATIONS: ELECTRICAL

SPECIFICATIONS: MECHANICAL

Low voltage (data), limited to 30 VDC High voltage supply (for computer use only) 120 VAC, 15A (UL), 5A (CSA) 230-240 VAC, 16A (CE only)

Housing: Cast aluminum base Latch: Type 304 Stainless Steel (1CR18NI19) Cover: Polycarbonate, UV rated, V-O Flame rated Gasket: Thermoplastic elastomer Insert Material: Acrylic UL94HB

HOUSING CODE: R

APPROVALS

M M 35 R

RoHS

UL RECOGNIZED: E207344 Type 4, IP-65 (Outdoor Use) CSA: LR110845 (not for interrupting circuit) CE: EN61010/EN60950 (Foreign Power Outlets)

5001 Tremont Avenue Davenport, IA 52807 (800) 280-9517 Fax: (563) 386-9639 www.GracePort.com

©2012 Grace Engineered Products, Inc. DataSheets:PMH_T4_2/2012 GracePort® is a registered Trademark of Grace Engineered Products, Inc