Drawings

Report 6 Downloads 326 Views
3

2

GENERAL NOTES:

INTERNATIONAL AFFAIRS PARTIAL REMODEL SHARWAN SMITH STUDENT CENTER SOUTHERN UTAH UNIVERSITY

1.

ARCHITECTS 577 South 200 East S L C, Utah 84111 ph: (801) 533-2100 jrcadesign.com

351 W 200 S CEDAR CITY, UT 84720

ABBREVIATIONS

D

A AC ADD A/C ALT. AL A.B. & ARCH ASP. @ B BSMT. B.M. BLKG. BD. B.O. BLDG. C CAB'T C.I.P. C.B. CLG. CL C.T. CH C.O. CLR. CL. COL. CONC. CMU COND. CONN. CONST. CONT CJ

C:\Users\mgreen\Documents\16040 - SUU Smith Center Design Option 2_mjgWJPKP.rvt

C

B

FL. ACOUSTIC ADDENDUM AIR CONDITIONING ALTERNATE ALUMINUM ANCHOR BOLT AND ARCHITECT(URAL) ASPHALT AT

BASEMENT BENCHMARK BLOCKING BOARD BOTTOM OF BUILDING

CABINET CAST IN PLACE CATCH BASIN CEILING CENTER LINE CERAMIC TILE CHANNEL CLEAN OUT CLEAR CLOSET COLUMN CONCRETE CONCRETE MASONRY UNIT CONDITION CONNECTION CONSTRUCTION CONTINUOUS CONTROL JOINT

D D.P. D.B. DIAG. DIA. DIM. DISP. DWL. DN. D.S. D.W.V. DWG.

DAMP PROOFING DECK BEARING DIAGONAL DIAMETER DIMENSION DISPENSER DOWEL DOWN DOWN SPOUT DRAINAGE WASTE VENT DRAWING

E EA. E.W.C. EL. ELEV. EQ. EQUIP. EXH. EXIST. E.J. EXT.

EACH ELEC. WATER COOLER ELECTRIC ELEVATION EQUAL EQUIPMENT EXHAUST EXISTING EXPANSION JOINT EXTERIOR

F FT. FIN. F.E. F.E.C. FIXT.

FEET FINISH(ED) FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FIXTURE

G GALV. GA. G.C. G.S.N. GL. GD. GRL. GRD. GYP. H HDW. HDWD. HTR. HT. H.P. H.M. HORIZ. H.B. H.W. HR. I IN. I.D. INSUL. INT. INV.

FLASHING

GALVANIZED GAUGE GENERAL CONTRACTOR GENERAL STRUCTURAL NOTES GLASS GRADE GRILLE GROUND GYPSUM

HARDWARE HARDWOOD HEATER HEIGHT HIGH POINT HOLLOW METAL HORIZONTAL HOSE BIB HOT WATER HOUR

INCH INSIDE DIAMETER INSULATION INTERIOR INVERT

J JAN. JT. JST.

JANITOR JOINT JOIST

L LAM. LDG. LAV. LT. L.W.C. LVR.

LAMINATED LANDING LAVATORY LIGHT LIGHT WEIGHT CONCRETE LOUVER

M M.B. MFR. M.O. MAT'L MAX. MECH. MTL. MIN. MLDG. MULL.

MACHINE BOLT MANUFACTURER MASONRY OPENING MATERIAL MAXIMUM MECHANICAL METAL MINIMUM MOLDING MULLION

N N.G. NOM. N/A N.I.C. N.T.S.

NATURAL GRADE NOMINAL NOT APPLICABLE NOT IN CONTRACT NOT TO SCALE

O O.C. OPNG. O.D. O.F.S. O.F.C.I.

P PT. PTD. PR. PNL. d P.L. PL. PLBG. P.C.

MATERIALS / SYMBOLS

ON CENTER OPENING OUTSIDE DIAMETER OVERFLOW SCUPPER OWNER FURNISHED, CONTRACTOR INSTALLED

PLYW'D P.S.I. P.S.F.

PLYWOOD POUND PER SQUARE INCH POUNDS PER SQUARE FOOT

R RAD. REC. REG. REQ'D R.A. REV. R.D. RFG. RM. RGH. RND.

RADIUS RECOMMENDATION REGISTER REQUIRED RETURN AIR REVISION ROOF DRAIN ROOFING ROOM ROUGH ROUND

WOOD MOLDING

1

SCREW SECTION SELECT SHEET SIMILAR SLIDING SMOOTH SPECIFICATION SPLASH SQUARE STAINLESS STEEL STANDARD STRUCTURE SUPPLY AIR SUSPENDED SWITCHBOARD

T TELCO T.G. T&G T&B T.O. T.O.C. T.O.D. T.O.P. TYP.

TELEPHONE COMPANY TEMPERED GLASS TONGUE & GROOVE TOP & BOTTOM TOP OF TOP OF CURB TOP OF DECK TOP OF PARAPET TYPICAL

U U.N.O.

UNLESS NOTED OTHERWISE

V V. V.T.R. VERT. V.G. VEST. V.C.T. V.C.P.

VENT VENT THROUGH ROOF VERTICAL VERTICAL GRAIN VESTIBULE VINYL COMPOSITION TILE VITREOUS CLAY PIPE

W W.C. W.H. W.P. W.R. W.W.F. W.F. WDW. W/ W/O WD.

WATER CLOSET WATER HEATER WATER PROOF WATER RESISTANT WELDED WIRE FABRIC WIDE FLANGE WINDOW WITH WITHOUT WOOD

BUILDING SECTION FLAG

AEXXX SIM CONCRETE (SECTION)

1

GYPSUM BOARD (SECTION)

AEXXX SIM

WALL SECTION / EXTERIOR ELEVATION

TILE (PLAN)

COMPACTED GRAVEL (SECTION)

S SCR. SECT. SEL. SHT. SIM. SLDG. SM. SPEC. SPL. SQ. S.S. STD. STRUC. S.A. SUSP. SW.BD.

DESIGN TEAM CENTERLINE

PLYWOOD (SECTION)

COMPACTED SUBGRADE

1 AEXXX

INTERIOR ELEVATION

1 AEXXX

DETAIL

SIM STEEL FRAMING (PLAN, SECTION)

CMU (PLAN, SECTION)

BRICK VENEER (PLAN, SECTION)

RIGID INSULATION (SECTION)

A

GRID HEAD

1i

WINDOW TAG

101A

DOOR TAG

ROOM NAME 101

ROOM TAG

DRAWING INDEX GENERAL INFORMATION GI101 GENERAL INFORMATION GI111 VICINTIY PLAN

ARCHITECT JRCA, Architects 577 South 200 East Salt Lake City, Utah 84111 (801)533-2100 Ph. Contact: Danny Fuchs [email protected]

MECHANICAL & PLUMBING ENGINEER VAN BOERUM & FRANK ASSOCIATES 230 North 1680 East Bldg. V Saint George, Utah 84790 (435)674-4800 Ph. Contact: Ladd M. Birch [email protected]

ARCHITECTURAL AE101 AE161 AE411

FLOOR PLAN & DEMOLITION PLAN REFLECTED CEILING PLAN & DEMOLITION REFLECTED CEILING PLAN INTERIOR ELEVATIONS

MECHANICAL MH001 MH101 MH601

MECHANICAL LEGEND AND ABBREVIATIONS MECHANICAL PLAN MECHANICAL SHCEDULES AND DETAILS

ELECTRICAL E001 E101 E201 E301

SYMBOLS, SCHEDULES AND NOTES ELECTRICAL DEMOLITION PLANS ELECTRICAL PLANS ELECTRICAL DIAGRAMS

ELECTRICAL ENGINEER BNA CONSULTING 635 South State Street Salt Lake City, Utah 84111 801.532.2196 Ph. Contact: Ian Madison [email protected]

WALL TYPE

1

KEYNOTE TAG

1

VICINITY MAP

1

REVISION TAG

G3 ELEVATION NAME

1 AEXXX

WINDOW GLAZING TAG

ELEVATION, (DATUM)

PROJECT #:

VIEW NAME SCALE

DRAWING TITLE

SCALE

DATE

PAINT PAINTED PAIR PANEL PENNY PLASTIC LAMINATE PLATE PLUMBING PLUMBING CONTRACTOR

4/28/2017 4:15:09 PM

GI101

A 3

2

REVISION

GENERAL INFORMATION

PROJECT LOCATION

4

16040

CONSTRUCTION DRAWINGS 5/2/2017

CONSTRUCTION DRAWINGS 5/2/2017 5

WHILE THE DOCUMENTS ARE SEPARATED BY SHEET NUMBERS FOR CONVENIENCE IN REFERENCING DOCUMENTATION, SHEET NAMES AND NUMBERS ARE NOT INTENDED TO DEFINE SCOPE. CONTRACTORS AND SUBCONTRACTORS ARE RESPONSIBLE FOR ALL WORK DESCRIBED IN THE ENTIRE PACKAGE.

351 W 200 S CEDAR CITY, UT 84720

4

INTERNATIONAL AFFAIRS PARTIAL REMODEL SHARWAN SMITH STUDENT CENTER SOUTHERN UTAH UNIVERSITY

5

1

5

4

3

2

ARCHITECTS 577 South 200 East S L C, Utah 84111 ph: (801) 533-2100 jrcadesign.com

PROJECT LOCATION

C:\Users\mgreen\Documents\16040 - SUU Smith Center Design Option 2_mjgWJPKP.rvt

C

PROJECT #:

351 W 200 S CEDAR CITY, UT 84720

INTERNATIONAL AFFAIRS PARTIAL REMODEL SHARWAN SMITH STUDENT CENTER SOUTHERN UTAH UNIVERSITY

D

16040

CONSTRUCTION DRAWINGS 5/2/2017 DATE

REVISION

B

VICINTIY PLAN PROJECT NORTH

4/28/2017 4:15:09 PM

SHARWAN SMITH BUILDING SOUTHERN UTAH UNIVERSITY A4 GI111

GI111

VICINTIY MAP SCALE

1/32" = 1'-0"

A 5

4

3

2

1

5

4

3

2

GENERAL NOTES: ROOM FINISH SCHEDULE

1.

SEE SHEET GI101 FOR ARCHITECTURAL LEGENDS, SYMBOLS, AND ABBREVIATIONS.

WALL FLOOR

BASE

N

E

S

W

F1/F2 F1 F2 F1 F1

B2 B1 B1 B1 B1

W1 W1 W1 W1 W1

W1 W1 W1 W1 W1

W1 W1 W1 W1 W1

W1 W1 W1 W1 W1

WAITING RECEPTION WAITING MEETING ROOM OFFICE

NOTES

ARCHITECTS 577 South 200 East S L C, Utah 84111 ph: (801) 533-2100 jrcadesign.com

PROJECT LIMIT LINE

REINSTALL EXSITING CARPET TILE PAVER TILE

0° .0 85

02.04

105A

6" HIGH RUBBER BASE WOOD BASE; COMPLY WITH C4/AE101

02.02 02.03 A

DOOR

7'-0" 7'-0" 8'-0" 7'-0"

TYPE

MATL

FINISH

GLAZING

TYPE

MATL

FINISH

D1 D1 D2

WD WD WD

DF1 DF1 DF1

G1 G1 --

--F1

HM HM HM

FF1 FF1 FF1

DETAILS HEAD JAMB

ASSEMBLY FIRE RATING

A

-A5/AE101

104A

AE411 B3

AE411 B4

0° .0 85

WAITING 103

DOOR & FRAME FINISH LEGEND FF1

GLAZING SCHEDULE G1 G2 G3

A ABV.

09.01

ABV.

ABV.

1"

06.03 09.01

1'-6"

1/4" CLEAR - TEMPERED 1/4" CLEAR EXISTING GLAZING TO REMAIN

A*

A4/AE101

FRAME FINISH

02.04 02.05

PROJECT LIMIT LINE

A5 AE411

09.01

NOTES

WAITING 101

102A

RECEPTION 102

4'-8"

AE411 B2

06.03

NOTE: MATCH EXISTING BASE; FEILD VERIFY PRIOR TO BID

MEETING ROOM 104

0° .0 90

2'-11" 6'-0" 3'-0" 3'-0"

FRAME

A

2'-3"

EXISTING WALL TO BE REMOVED EXISTING WALL BASE TO REMOVED AND SALVAGED PATCH AND REPAIR EXISTING WALL EXISTING CARPET TILE TO BE REMOVED AND SALVAGED FOR RE-INSTALLATION RECEPTION DESK, NIC FLOOR FINISHED TRANSITION

A

4"

PROJECT LIMIT LINE

DOOR AND FRAME SCHEDULE SIZE DOOR WIDTH HEIGHT

KEY NOTES:

A

PAINTED SURFACE

D

102A 104A 105A

A ABV.

WALL FINISH W1

OFFICE 105

2'-6"

B1 B2

8'-0"

BASE FINISH

A ABV.

2'-9"

4'-11"

F1 F2

2'-8"

FLOOR FINISH

LEGEND:

FIELD PAINTED

PROJECT LIMIT LINE POPLAR; PAINT

DOOR FINISH FACTORY FINISHED

C4 AE101

F.V.

02.04

6"

DF1

HATCH INDICATES EXTEND OF FLOOR FINISH F2; HATCH PATTERN DOES NOT DEPICT ACTUAL TILE PATTERN.

6'-7"

BASE DETAIL SCALE

C3 AE101

3" = 1'-0"

FLOOR PLAN SCALE

1/4" = 1'-0"

C:\Users\mgreen\Documents\16040 - SUU Smith Center Design Option 2_mjgWJPKP.rvt

C

W

PROJECT LIMIT LINE

W

INTERIOR WALL LEGEND: A

DOOR TYPES SCALE

B4 AE101

1/4" = 1'-0"

FRAME TYPES SCALE

1/4" = 1'-0"

B

02.05

02.05

TYP.

TYP.

3 5/8" 20 GA METAL STUDS AT 16" O.C. W/ (1) LAYER 5/8" GYP. BD. EACH SIDE. EXTEND WALL ASSEMBLY TO 4" ABOVE ADJACENT CEILING; BRACE TO STRUCTURE ABOVE @ 32" O.C. EACH WAY, STAGGER ; STC 45

PROJECT #:

16040

CONSTRUCTION DRAWINGS 5/2/2017

PROJECT LIMIT LINE

F1

D2

PROJECT LIMIT LINE

D1

H

H

G1

351 W 200 S CEDAR CITY, UT 84720

ROOM NAME

101 102 103 104 105

INTERNATIONAL AFFAIRS PARTIAL REMODEL SHARWAN SMITH STUDENT CENTER SOUTHERN UTAH UNIVERSITY

ROOM NO.

DATE

REVISION

02.02

02.03

4"

FACE OF WALL; WHERE OCCURS. H.M. FRAME.

TYP.

02.02

(2) METAL STUDS, EXTEND TO B.O. STRUCTURE.

WALL AS SCHEDULED. CONT. SEALANT, EA SIDE. H.M. FRAME.

FLOOR PLAN & DEMOLITION PLAN

PROJECT LIMIT LINE

DOOR AS SCHEDULED.

WALL AS SCHEDULED. CONT. SEALANT, EA SIDE. DOOR AS SCHEDULED.

5/1/2017 11:53:31 AM

PROJECT NORTH

0"

A5 AE101

DOOR HEAD DETAIL SCALE

A4 AE101

1 1/2" = 1'-0"

DOOR JAMB DETAIL SCALE

A3 AE101

1 1/2" = 1'-0"

1/4" = 1'-0"

A 5

4

3

8'

AE101

DEMOLITION FLOOR PLAN SCALE

4'

2

1

5

4

3

2

9'-0"

ARCHITECTS

PROJECT LIMIT LINE

577 South 200 East S L C, Utah 84111 ph: (801) 533-2100 jrcadesign.com 9'-0"

KEY NOTES:

SCREW ATTACHMENT TO STUDS

9'-0"

EXISTING BEAM TO BE REMOVED; EXISTING PARTIITION ABOVE BEAM TO BE REMOVED EXISTING CEILING TO BE REMOVED EXISTING LIGHT FIXTURE; SEE ELEC. DWGS. EXISTING MECH. DIFFUSER/GRILLE, SEE MECH. DWGS. GYP.BD. CONTROL JOINT

02.06 02.07 02.08 06.04

9'-0"

BERC2 SEISMIC CLIP OR EQUAL @ EACH GRID

A4

9'-0"

9'-0"

" 1/8

SCHEDULED CEILING

REFLECTED CEILING PLAN LEGEND:

B4

PROJECT LIMIT LINE

06.04

AE161

RM VARIES

WALL ASSEMBLY AS SCHEDULED

NOTE: COMPLY W/ 1997 UBC STANDARDS 25-2

C4 AE161

SCHEDULED SUSPENSION SYSTEM

2x2 LIGHT FIXTURE - SEE ELEC. DWGS

ICC-ESR-1308 (MANUFACTURE REQUIREMENTS) 2x4 LIGHT FIXTURE - SEE ELEC. DWGS

RESTRAINED EDGE DETAIL @ ACOUSTICAL LAY-IN CEILING SCALE

ROOM NUMBER CEILING HEIGHT

C3 AE161

3" = 1'-0"

REFLECTED CEILING PLAN SCALE

RETURN AIR GRILL - SEE MECH. DWGS

1/4" = 1'-0"

C

C:\Users\mgreen\Documents\16040 - SUU Smith Center Design Option 2_mjgWJPKP.rvt

SUPPLY AIR GRILL - SEE MECH. DWGS

02.06

02.07

02.08

TYP.

02.06

TYP.

TYP.

CEILING TYPES:

EXISTING WALL ABOVE

2X2 SUSPENDED ACOUSTICAL PANEL CEILING SYSTEM; COMPLY WITH C4/AE161

PROJECT LIMIT LINE

?

FRAMED GYP. BD. CEILING

SCHEDULED CEILING

CEILING DETAIL SCALE

3" = 1'-0"

B

3"

02.08

PROJECT LIMIT LINE

B4 AE161

PROJECT LIMIT LINE

PROJECT #:

02.01

TYP.

DATE

4/28/2017 4:15:08 PM

A4 AE161

1/2" X 1/2" REVEAL EDGE TRIM

PROJECT NORTH

CEILING DETAIL SCALE

A3 AE161

3" = 1'-0"

1/4" = 1'-0"

A 5

4

3

4'

REFLECTED CEILING PLAN & DEMOLITION REFLECTED CEILING PLAN

8'

AE161

DEMOLITION REFLECTED CEILING PLAN SCALE

REVISION

9'-0"

PROJECT LIMIT LINE

0"

16040

CONSTRUCTION DRAWINGS 5/2/2017

02.07

SCHEDULED CEILING

351 W 200 S CEDAR CITY, UT 84720

7/8" EDGE TRIM WITH CONT. ACOUSTICAL SEALANT BETWEEN WALL ASSEMBLY AND TRIM

INTERNATIONAL AFFAIRS PARTIAL REMODEL SHARWAN SMITH STUDENT CENTER SOUTHERN UTAH UNIVERSITY

AE161 8" M AX .

7/8 "

PROJECT LIMIT LINE

D

PROJECT LIMIT LINE

02.01

2

1

5

4

3

2

GENERAL NOTES: 1

TELEPHONE

CONTROLS

SIGNS

LAVATORY

URINALS

ARCHITECTS

4" 1'-6"

DRYER

1'-0"

TO 3'-0"

5'-0"

MIN.

2'-9"

NOTE 2

TOILETS

577 South 200 East S L C, Utah 84111 ph: (801) 533-2100 jrcadesign.com

TYP.

16"-18"

8"

DRINKING FOUNTAIN

H.C.

1'-6"

1'-9"

TO 3'-0"

2'-9" 1'-0"

6" MAX.

TOWEL DISPENSER

1'-6"

3'-6"

1'-0"

4'-0"

11" - 17"

NOTE 3

NOTE 4

MIN.

3'-2"

1'-0"

SANITARY NAPKIN DISPENSER

1'-6"

H.C.

5'-0"

ELECTRICAL OUTLET

18"

4'-0"

5'-0"

3'-0" MAX.

2'-3" MIN.

9" MIN.

H.C.

2'-0"

2'-0"

MIN. CLR.

3'-0"

3'-4"

STANDARD

SOAP DISPENSE R

2'-8"

3'-4"

MIRROR

2'-7"

2'-3" MAX.

17" TO 19"

4'-6"

H.C. ACCESSIBLE

SANITARY NAPKIN DISPOSAL

TOILET TISSUE DISPENSER

--

NOTE 1: 48" MAX. HT. FOR ACCESSORY CONTROLS ACCESSED BY A FORWARD OR SIDE REACH

NOTE 1

NOTE 4: 2'-10" MEASURED FROM FINISH FLOOR TO RIM OF SINK/LAV

FIRE CABINET ELECTRICAL SWITCH

8" MAX.

NOTE 2: 12" ABOVE GRAB BAR. 46" IF RECESSED

NOTE 3: 40" MAX. TO BOTTOM OF REFLECTING SURFACE

3'-4"

GENERAL NOTES: - ALL MEASUREMENTS ARE TO FINISH FLOOR - ALL ADA ACCESSIBLE FIXTURES TO COMPLY WITH ANSI A117 LATEST EDITION - ENCLOSURE CAN PROTRUDE A MAX. OF 19" AND CANNOT REDUCE THE MIN. REQUIRED CLEAR WIDTH OF ACCESSIBLE PATH.

ACCESSORIES

SHOWER

PARTITIONS

STANDARD MOUNTING HEIGHTS

D4 AE411

SCALE

1/4" = 1'-0"

D

SCHEDULED WALL HOLLOW METAL FRAME, PAINT

HOLLOW METAL FRAME, PAINT

GYPSUM BOARD; PATCH AND REPAIR

CONT. SEALANT, TYP.

HOLLOW METAL FRAME, PAINT

5 3/4" SCHEDULE GLASS

5 3/4"

5 3/4"

5 3/4"

SCHEDULE GLASS

NOTE: MATCH FRAME PROFILE OF EXITING HM. FIELD VERIFY PRIOR TO BID

SCHEDULE GLASS

SCHEDULE GLASS HOLLOW METAL FRAME, PAINT

5 3/4"

CONT. SEALANT, TYP.

C5 AE411

SCALE

5 3/4" HOLLOW METAL FRAME, PAINT

NOTE: MATCH FRAME PROFILE OF EXITING HM. FIELD VERIFY PRIOR TO BID

HOLLOW METAL FRAME JAMB (HEAD SIM)

HOLLOW METAL FRAME JAMB (HEAD SIM)

C4 AE411

3" = 1'-0"

CONT. SEALANT, TYP.

SCHEDULE GLASS

SCALE

C3 AE411

3" = 1'-0"

HOLLOW METAL FRAME JAMB SCALE

C2 AE411

3" = 1'-0"

PROVIDE AND INSTALL MTL. STUD/TRACK; MATCH PROFILE OF EXISTING METAL STUDS

DOOR SCHEDULE

HOLLOW METAL FRAME JAMB SCALE

C1 AE411

3" = 1'-0"

NOTE: MATCH FRAME PROFILE OF EXITING HM. FIELD VERIFY PRIOR TO BID

H. M. FRAME JAMB (HEAD AND JAMB SIM) SCALE

3" = 1'-0"

C

C:\Users\mgreen\Documents\16040 - SUU Smith Center Design Option 2_mjgWJPKP.rvt

GLAZING SCHEDULE 2'-8"

4'-0"

2'-8"

4'-0"

2'-8"

G1 G2 G3

4'-0"

C4

C4

AE411

1'-6"

AE411

G2

G2

G2

C2 AE411

EQ

EQ 2"

G1

AE411

AE411 TYP.

PROJECT #: EQ

W 2"

HOLLOW METAL FRAME

MEETING ROOM ELEVATION SCALE

HOLLOW METAL FRAME

2"

HOLLOW METAL FRAME

B3 AE411

G1

C1 6'-6"

AE411

C2

6"

G1

C3

6"

G1

C3 7'-2"

7'-2"

AE411

B4 AE411

1/4" = 1'-0"

B2 AE411

1/4" = 1'-0"

16040

CONSTRUCTION DRAWINGS 5/2/2017 DATE

MEETING ROOM ELEVATION SCALE

1/4" CLEAR - TEMPERED 1/4" CLEAR EXISTING GLAZING TO REMAIN

351 W 200 S CEDAR CITY, UT 84720

FACE OF EXISTING WALL

NOTE: MATCH FRAME PROFILE OF EXITING HM. FIELD VERIFY PRIOR TO BID

INTERNATIONAL AFFAIRS PARTIAL REMODEL SHARWAN SMITH STUDENT CENTER SOUTHERN UTAH UNIVERSITY

CONT. SEALANT, TYP.

5 3/4"

NOTE: MATCH FRAME PROFILE OF EXITING HM. FIELD VERIFY PRIOR TO BID

REVISION

WAITING ELEVATION SCALE

1/4" = 1'-0"

B

FACE OF EXISTING WALL

C4 PROVIDE AND INSTALL HM FRAME; CONT. WELD; GRIND SMOOTH; MATCH PROFILE OF EXISTING FRAME; PAINT

AE411

C5 C4

7'-2"

AE411 G1

G1

AE411 SIM

C2 G1 AE411

G3

G3

G2

G3

G3

G3

G3

G1

G3

G3

PROVIDE AND INSTALL HM FRAME; CONT. WELD; GRIND SMOOTH; MATCH PROFILE OF EXISTING FRAME; PAINT OPEN

6"

INTERIOR ELEVATIONS

5/1/2017 11:20:12 AM

EQ 2"

A5 AE411

2"

INTERIOR ELEVATION SCALE

EQ

W

HOLLOW METAL FRAME

W

2"

REMOVE AND REINSTALL EXISTING ADJACENT GLASS AS NECESSARY TO FACILITATE WORK.

2"

HOLLOW METAL FRAME

A3 AE411

1/4" = 1'-0"

REMOVE AND REINSTALL EXISTING ADJACENT GLASS AS NECESSARY TO FACILITATE WORK.

AE411

INTERIOR ELEVATION SCALE

1/4" = 1'-0"

A 5

4

3

2

1

5

ARCHITECTS 577 South 200 East S L C, Utah 84111 ph: (801) 533-2100 jrcadesign.com

C

PROJECT #:

351 W 200 S CEDAR CITY, UT 84720

INTERNATIONAL AFFAIRS PARTIAL REMODEL SHARWAN SMITH STUDENT CENTER SOUTHERN UTAH UNIVERSITY

D

16040

PROGRESS DRAWINGS 01/30/2017 DATE

REVISION

B

SYMBOLS, SCHEDULES AND NOTES

LOUDSPEAKER

CEILING

7.

E001 A 5

4

3

2

1

5

ARCHITECTS 577 South 200 East S L C, Utah 84111 ph: (801) 533-2100 jrcadesign.com

PROJECT LIMIT LINE

C

PROJECT LIMIT LINE

PROJECT #:

351 W 200 S CEDAR CITY, UT 84720

PROJECT LIMIT LINE

D

INTERNATIONAL AFFAIRS PARTIAL REMODEL SHARWAN SMITH STUDENT CENTER SOUTHERN UTAH UNIVERSITY

PROJECT LIMIT LINE

PROJECT LIMIT LINE

16040

PROGRESS DRAWINGS 01/30/2017

PROJECT LIMIT LINE

B

REVISION

PROJECT LIMIT LINE

DATE

ELECTRICAL DEMOLITION PLANS

PROJECT LIMIT LINE

E101 A 5

4

3

2

1

5

ARCHITECTS 577 South 200 East S L C, Utah 84111 ph: (801) 533-2100 jrcadesign.com

EXISTING ELECTRICAL ROOM PROJECT LIMIT LINE

OFFICE 105

MEETING ROOM 104

WAITING 103

PROJECT LIMIT LINE

C

EXISTING ELECTRICAL ROOM PROJECT LIMIT LINE

OFFICE 105

PROJECT #:

351 W 200 S CEDAR CITY, UT 84720

INTERNATIONAL AFFAIRS PARTIAL REMODEL SHARWAN SMITH STUDENT CENTER SOUTHERN UTAH UNIVERSITY

WAITING 101

RECEPTION 102

PROJECT LIMIT LINE

PROJECT LIMIT LINE

D

16040

PROGRESS DRAWINGS 01/30/2017

B

WAITING 101

RECEPTION 102

WAITING 103

REVISION

PROJECT LIMIT LINE

PROJECT LIMIT LINE

DATE

MEETING ROOM 104

ELECTRICAL PLANS PROJECT LIMIT LINE

E201 A 5

4

3

2

1

5

ARCHITECTS 577 South 200 East S L C, Utah 84111 ph: (801) 533-2100 jrcadesign.com

C

PROJECT #:

351 W 200 S CEDAR CITY, UT 84720

INTERNATIONAL AFFAIRS PARTIAL REMODEL SHARWAN SMITH STUDENT CENTER SOUTHERN UTAH UNIVERSITY

D

16040

PROGRESS DRAWINGS 01/30/2017 DATE

REVISION

B

ELECTRICAL DIAGRAMS

E301 A 5

4

3

2

1