DT-355 Dual Technology Line Voltage Ceiling Sensor

Report 2 Downloads 75 Views
c o m m e r c i a l O C C U P A N C Y S E N S OR S & C o n t r o l s

DT-355 Dual Technology Line Voltage Ceiling Sensor Operates at 120, 277 or 347 VAC, 50/60 Hz

Architecturally appealing low profile appearance

Terminal wiring for quick and easy installation

Auto set automatically selects optimal settings for each space

Walk-through mode increases savings potential

Ultrasonic diffusers give more comprehensive coverage PROJECT LOCATION/TYPE

Product Overview

Description

Auto Set

WattStopper’s low profile DT-355 dual technology occupancy sensor combines the benefits of passive infrared (PIR) and ultrasonic technologies. The sensor mounts on the ceiling with a flat, unobtrusive appearance and provides 360 degrees of coverage.

The DT-355 requires no adjustment at installation. Auto set continuously monitors the controlled space to identify usage patterns. Using this information, it automatically adjusts the time delay and sensitivity settings for optimal performance and energy efficiency. The sensor assigns short delays (as low as 5 minutes) for times when the space is usually vacant, and longer delays (up to 30 minutes) for busier times.

Operation The DT-355 is line voltage and operates at 120, 277 or 347 VAC. The sensor turns lighting on when both PIR and ultrasonic technologies detect occupancy. PIR technology senses the difference between infrared energy from a human body in motion and the background space. Ultrasonic technology uses high frequency (40KHz) ultrasound to sense motion within the space. Once lighting is on, detection by either technology holds lighting on. When no occupancy is detected for the length of the time delay, lighting turns off. The DT-355 can also be set so that only one technology is needed to trigger or both technologies are needed to hold lighting on.

Features

• Advanced control logic based on RISC microcontroller provides: • Detection Signature Processing eliminates false triggers and provides immunity to RFI and EMI • Walk-through mode turns lights off 3 minutes after the area is initially occupied – ideal for brief visits such as mail delivery • Built-in light level sensor featuring simple, one-step setup

www.wattstopper.com 800.879.8585

Application WattStopper’s patented dual technology has the flexibility to work in a variety of applications, where one technology alone could encounter false triggers. Ideal applications include classrooms, open office spaces, large offices, and computer rooms. In addition, because the DT-355 can be mounted onto a variety of junction boxes, the sensor has the flexibility to be used in a wide range of spaces. The sensors eliminate the need for a power pack by using line voltage wiring. • Ultrasonic diffusion technology spreads coverage to a wider area (patent pending) • DIP switch simplifies sensor adjustments • LEDs indicate occupancy detection • Uses existing line voltage wiring and doesn’t require a power pack • Six occupancy logic options give users the ability to customize control to meet application needs • Qualifies for ARRA-funded public works projects

DT-355 Wiring Diagram

• Multi-level, 360° Fresnel lens for superior occupancy detection • Mounting options: 4 square junction box with double gang mudring; 4 inch octagonal junction box • Dimensions: 4.50” diameter x 1.45” deep (114.3mm x 25.9mm) • UL and cUL listed • Five year warranty

Ceiling Mounting

Neutral

Trigger

Product Controls Ultrasonic sensitivity trimpot

Light level pushbutton

DIP switches E

8 7 6 5 4 2 1

PIR Activity LED (Red)

Either(5) Either(5)

PIR

Either

Either(5)

Both

Both

Both(5)

PIR

PIR

PIR(5)

Ultra

Ultra

Ultra(5)

Front Cover

Man. Either Either(30)

Man.

Both

Both(30)

Switch#

Logic 1 2 3 Standard Option 1 Option 2 Option 3 Option 4 Option 5 Option 6 Option 7

Time Delay 4 5 6

Ultrasonic activity LED (Green)

Coverage

= ON = OFF

Keyhole slots (for mounting to 4" octagonal box)

3

ON

Both Either Either Either

DIP Switch Settings

Double gang mudring mounting holes

EC

Ultrasonic transducer cones

Standard Option 1 Option 2 Option 3 Option 4 Option 5 Option 6 Option 7

5 sec/SmartSet 5 minutes 10 min. 10 minutes 15 min. 15 minutes 20 minutes 30 min.

PIR lens

Coverage Pattern

= walk-through mode

44 ft (13.4m)

Standard Option 1 Option 2 Option 3 Option 4 Option 5 Option 6 Option 7

Either(5) Both(5) PIR(5) Ultra(5) Either(30) Both(30)

Switch#

1 2 3

Initial Occupancy Maintain Occupancy Re-trigger (seconds duration)

Controls & Settings

Occupancy Logic

(Optional)

Rear Housing Sensor Flange = ON Logic = OFF Screws

Either(5)

Trigger Time Delay 4 5 6

Standard Both Either 5 sec/SmartSet Option 1 Either Either 5 minutes Option 2 PIR Either 10 min. Option 3 Both Both 10 minutes Option 4 PIR PIR 155 min. Option Ultra Ultra 15 minutes Option 6 Man. Either 20 minutes Option 7 Man. Both 30 min.

Occupancy Logic

Ground

Occupancy

Hot

Initial Occupancy Maintain Occupancy Re-trigger (seconds duration)

Load

Either(5)

= walk-through mode

= ON = OFF

Either(5) Either(5) Either(5) Both(5) PIR(5) Ultra(5) Either(30) Both(30)

Switch#

Logic LEDs 7 1 2 3 Standard Disabled Option 1 Enabled Option 2 Option 83 PIR Sensitivity Option 4 Minimum Option 5 Max./SmartSet Option 6 Option 7 Occupancy

Neutral

Load

Occupancy Logic

Initial Occupancy Maintain Occupancy Re-trigger (seconds duration)

4" Square, 2.25" Deep* Junction Box with Double Gang Trigger Mudring attached Standard Both Either Option 1 Ceiling Either Either Drop Option 2 PIR Either Option 3 Both Both Option 4 PIR PIR CA-1 Adapter Option 5 Ultra Ultra Option 6 Man. Either Option 7 Man. Both

Occupancy

Wiring & Mounting

• 120/277/347 VAC, 50/60 Hz • Ultrasonic frequency of 40kHz • Time delays: Auto set, fixed (5, 10, 15, 20, or 30 minutes), walk-through, test-mode • Sensitivity adjustment: Auto set or reduced sensitivity (for PIR sensitivity); ultrasonic sensitivity is variable with trimpot • Built-in light level sensor – works from 10 to 300 footcandles (107.6 to 3,229.2 lux)

LEDs 7 The technologyDisabled control (occupancy logic) options are adjustable Time Delay 4 5 6 by user. The standard setting (recommended for most applicaEnabled 5 sec/SmartSet tions) is both technologies to trigger on, either to5 hold on. minutes PIR Sensitivity 8 10 min. Minimum 10 minutes 15 min. Max./SmartSet 15 minutes 20 minutes 30 min.

= walk-through mode

Coverage shown is maximum and represents half-step walking LEDs 7 motion. Under ideal conditions, coverage for half-step walking Disabled motion can reach up to 1000 ft2 (92.9 m2). Enabled

40 ft x 40 ft (12.2m x 12.2m)

Ordering Information

Catalog No. Voltage Load Rating DT-355 DT-355-U CA-1

120 VAC, 50/60 Hz 277 VAC, 50/60 Hz 347 VAC, 50/60 Hz



0-800W Ballast/Tungsten 0-1200W Ballast 0-1500W Ballast

PIR Sensitivity 8 Minimum up to 1000 ft2, (92.9 m2Max./SmartSet )

Coverage

Cosmetic adapter for ceiling installations with 4” square j-box or Wiremold #V5748-2 box

Sensors are white.

Pub. No. 15807 rev. 11/2010

www.wattstopper.com | 8 0 0 . 8 7 9 . 8 5 8 5

c o m m e r c i a l O C C U P A N C Y S E N S OR S & c o n t r o l s

Specifications