365/7 DAY ADVANCE MULTIPURPOSE CONTROLS 1,2 OR 4 CHANNEL APPLICATIONS • Indoor and outdoor lighting • Heating and air conditioning • Security Systems • Horns and bells • Low voltage lighting • Misting and spraying • Roof cooling • Clock correction systems • Process functions FEATURES SCHEDULING: 99 ON & OFF set points allow individual programs for each day of the week at a minumum 1 minute apart. SEASONS: 1 to 4 with different daily schedules which can wrap around into the new year. HOLIDAYS: 1 to 24 individual dates SIGNAL/PULSE DURATION: 2 different settings per channel: each 1-99 seconds. DAYLIGHT SAVING: Automatic adjustment (can be omitted) LEAP YEAR: Automatic Compensation MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. In signal mode, activates pulse. CLOCK FORMAT: AM/PM or Military time POWER OUTAGE BACKUP: Permanent schedule retention. Supercapacitor provides 4 days of real time back up. SPECIFICATIONS TIMING ACCURACY: Line frequency TERMINAL RANGE: #14-#16AWG for line input. #12-#16AWG load outputs. OPERATING TEMPERATURE: -40˚ to 158˚F (-40˚ to +70˚C) POWER CONSUMPTION: 5VA Max : DTS100/200B 6VA Max : DTS400B ENCLOSURE: Noryl® Indoor/Outdoor NEMA 3R is standard. DIMENSIONS: 91/8” x 5” x 41/2”
L
NO C
LOAD
277V
BOARD
N
DTS SERIES
L
NO C NC LOAD WIRING DIAGRAMS N
AC LINE INPUT SELECT PROPER TERMINALS LOWER AND APPLY ONLY ONE VOLTAGE
120
208-240 277
DPDT L
120V AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE
N
120
LOAD
N
277V TIMER SUPPLY
DTS100B
L
LOAD
208-240V
C
NC
N
N
NO NC
C
NO NC
208-240 277
120V
L
208-240V
AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE
L LOAD
277V
N
120
N
CH 1 SPDT
CH 2 SPDT
C
TIMER SUPPLY
DTS200B
LOAD
N
NO NC
C
NO NC
208-240 277
120V
L
208-240V
AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE
L LOAD
277V
N DPDT
CH 3 SPDT
TIMER SUPPLY
DTS100B
UPPER BOARD
N
120
C
NO NC
GND NO
C
NC
C
NO NC
NO
C
NC
L
L
208-240V
DTS400B
CH 4 SPDT
208-240 277
120V AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE
LOAD
N
LOAD
N
277V
L
L
LOAD
LOAD N
N
N
CH 1 SPDT
CH 2 SPDT
NO C
TIMER SUPPLY
LOAD
NC
NO C
NC
LOWER BOARD N
120
208-240 277
L
120V AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE
LOAD
N
277V
N
CATALOG NO.*
UPC CODE
TIMER SUPPLY (VAC) 50/60Hz
NO. OF CHANNELS
DTS100B DTS200B DTS400B
82185 82186 82187
120/208-240/277 120/208-240/277 120/208-240/277
1 2 CH 1 SPDT 4
DTS200B
TYPE
C
TIMER SUPPLY
DTS100B, DTS200B VOLTAGE
AC LINE INPUT SELECT PROPER TERMINALS
N
120
120V
RATING
208-240 277
NO
208-240V
L
LOAD
208-240V
NC
L
DRY CONTACTS (UNPOWERED) DPDT SPDT CH 2 SPDT SPDT
NO NC
C
NO NC
DTS400B
RATING
VOLTAGE L
LOAD
277V ANDPurpose APPLY ONLY ONE VOLTAGE N General 24-277VAC 30A 30A 24-277VAC 120VAC 30A 10A DPDT Ballast 120-277VAC 277VAC 20A 10A Tungsten 120-277VAC TIMER15A 2A 120VAC C NO NC C SUPPLY Pilot Duty 120-277VAC 720VA 720VA 12-277VAC DTS100B 120VAC N 1HP 1HP Motor Load 120-277VAC 120V 208-277VAC208-240V 2HP 2HP L L AC LINE INPUT LOAD SELECT PROPER TERMINALS Resistive 28VDC 30A 30A 277V N AND APPLY ONLY ONE VOLTAGE 120