Commercial Electric INTEGRAT ED H O M E C O M F O RT Water Booster Water Heaters Commercial Electric INTEGRATED H O M E C O M F O RT Water Booster Water Heater
Electric boosters are designed to fit under counters and deliver sanitizing rinse water for all stationary rack and conveyor type commercial dishwashers Features & Benefits
AGA/ASME Rated T&P Valve
Our 10 gallon electric booster will raise preheated or cold water to 180° F rinse temperature for compliance with UL sanitation (NSF5) and all federal, state, county and local health department sanitation codes. In addition, these models can be used as circulating tank commercial electric water heaters for gravity or pump circulation to an auxiliary storage tank. They are available in 6 kW through 54 kW and in 208, 240, 277 and 480 voltages.
Factory installed relief valve
System Sentinel All electric booster models employ an element diagnostic panel, utilizing light emitting diodes (L.E.D.), corresponding to the number and location of each heating element. L.E.D.’s are energized when the electric elements are operating. An unlit L.E.D. pinpoints the exact location of a non-functioning element, making element operation diagnosis simple and positive.
Long Life Tank Design Proprietary steel formulation with a unique coat of high temperature porcelain enamel maximizes corrosion resistance resulting in a superior tank design.
Long Life Heating Elements Separate screw-in type elements feature a Nichrome wire filament, embedded in magnesium oxide sealed in a copper tube to resist water chemical corrosion…for long element life and a long life performance. Elements are directly immersed in the water for maximum recovery efficiency (98%) and are easily changed by simply screwing new ones into the tank.
Integral Fusing All models have integral fusing for each element.
Anode rods Two (2) magnesium anodes are installed in each tank for maximum corrosion resistance.
Electrical Connections Pre-wired, accessible control box with multiple knock-outs on side in size selections to match the National Electric Code. Sizes range from 1/2" to 2". A grounding screw is provided for attaching an equipment grounding conductor.
Single Panel Control Box It comes with hinged stainless steel door that provides immediate access to all electrical components and elements.
Terminal Block All models are equipped with UL Listed terminal blocks for simplicity of installation. The terminal block will accept either copper or aluminum field connect wire.
Rheem Booster
10-Gallon Capacity 6kW-54kW 208, 240, 277 and 480 Voltages
120 Volt Control Circuit All units are furnished with a fused 120 volt control circuit. All controls (thermostats, high temperature limit, etc.) are operated off of this basic 120 volt control circuit. This circuit is created by an internal multi-tap transformer of unique design that has four (4) taps for the primary voltages, 208, 240, 277 and 480.
Warranty 3-Year limited tank warranty See Commercial Warranty Certificate for complete information. Efficiency | All models meet or exceed thermal efficiency and standby loss requirements of current ASHRAE standards. (Part of the Federally mandated Energy Policy Act (EPact)). Also exceeds energy efficiency codes of all states including California Energy Commission (CEC). Safety and Construction | Design certified by Underwriters Laboratories (UL) to meet UL standard 1453 as electric booster and commercial storage tank water heaters. All models are UL Sanitation (NSF5). Certified for 150 PSI maximum working pressure.
Continued next page
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Manufacturing MEA FZE Dubai Airport Free Zone - Dubai, UAE www.rheem-mea.com
IIN T EEGGRAT OIM OM NT RATEEDDHA RE&CW AF TO E RT R I N T E G RAT E D HOME H O M E COMFORTT C O M F O RT IINTEGRATED
I
w
Commercial Electric INTEGRATED H O M E C O M F O RT Water Booster Water Heater
Rheem Booster Electric
Water Connections
Fuse Type
Hot outlet and cold inlet are 1-1/4" NPT dielectric nipples which prevent excessive turbulence of heated water and results in optimum tank draw.
The “G” in the model number represents Class G fuses.
Heavy Insulation an effective blanket of insulation completely surrounds tanks to limit heat loss and assure high operating efficiency.
Stainless steel legs 6" stainless steel legs are provided with each unit.
Fuseless Constructions Any standard model not exceeding 48 Amps (See “Electrical Characteristics” Table) may be ordered without element fuses. Add “N” after the fuse type designation. Example: E10-9-G becomes E10-9-GN
Approximate Shipping Weight 110 lbs./50 kgs.
Factory Accessories from Rheem-Ruud
MODEL NUMBERS
INPUT KW
E10-6-G
6
E10-9-G
9
E10-12-G
12
E10-15-G
15
E10-18-G
18
E10-24-G
24
E10-27-G
27
E10-30-G
30
E10-36-G
36
E10-45-G
45
E10-54-G
54
Solid state low water cut-off: probe type cut-off for field installation (AP8408).
WATER TEMPERATURE RATINGS MODEL NUMBER
TANK CAPACITY
THERMOSTAT TYPE
MINIMUM DELIVERED TEMPERATURE
MAXIMUM DELIVERED TEMPERATURE
HIGH TEMPERATURE LIMIT
E10
10 Gal./ 38L
Immersion
90°F / 32.2°C
190°F / 87.8°C
200°F / 93.3°C
OPTIONAL THERMOSTATS (GS MODELS ONLY) 213/4"
81/4"
OUTLET
T&P
43/4"
17"
133/4" 53/4"
INLET
THERMOSTAT
11/4" HOT
TEMPERATURE LIMIT CONTROL
OUTLET NIPPLE
11/4" COLD INLET NIPPLE
TRANSFORMER TERMINAL BLOCK
6"
211/2"
CONTACTORS FUSE BLOCKS (FUSED MODELS ONLY)
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Manufacturing MEA FZE Dubai Airport Free Zone - Dubai, UAE www.rheem-mea.com I N T E G RAT E D HOME H O M E COMFORTT C O M F O RT IINTEGRATED
I
w
Commercial Electric INTEGRATED H O M E C O M F O RT Water Booster Water Heater
Rheem Booster Electric
ELECTRICAL CHARACTERISTICS
Rheem Booster Electric
FULL LOAD CURRENT IN AMPERES
IMMERSION THERMOSTATS
NUMBER ELECTRICAL CHARACTERISTICS INPUT ELEMENT 240V 208V OF ELEMENTS
KW
9
NUMBER OF 3 ELEMENTS 3
12 6 15 9 18 12 18 15 24 18 27 18 30 24 36 27 36 30 45 36 54 36
3 3 3 3 3 3 6 3 6 3 6 6 6 6 6 6 9 6 9 6 9 9
INPUT 6 KW
WATTAGE
ELEMENT 2000 WATTAGE 3000 4000 2000 5000 3000 6000 4000 3000 5000 4000 6000 4500 3000 5000 4000 6000 4500 4000 5000 5000 6000 6000 4000
277V FULL LOAD CURRENT Phase PHASE IN AMPERES 1 3 1 240V 277V 25 14 22 Phase PHASE 38 22 33 1 3 1 50 29 43 25 14 22 63 36 54 38 22 33 75 43 65 50 29 43 – – – 63 36 54 100 58 87 75 43 65 113 65 98 – – – 125 73 108 100 58 87 150 87 130 113 65 98 – – – 125 73 108 188 109 163 150 87 130 225 130 195 – – –
PHASE 1
3 208V 29 17 PHASE 43 25 1 3 58 33 29 17 72 42 43 25 – – 58 33 87 50 72 42 116 67 – – 130 75 87 50 144 84 116 67 – – 130 75 173 100 144 84 217 125 – – 260 150 173 100
480V PHASE 1
3 480V 13 7 PHASE 19 11 1 3 25 15 13 7 31 18 19 11 38 22 25 15 – – 31 18 50 29 38 22 56 33 – – 63 36 50 29 75 43 56 33 – – 63 36 94 54 75 43 113 65 – –
NUMBER NUMBER OF OF IMMERSION THERMOSTATS CONTACTORS FUSES NUMBER NUMBER 2 6 OF OF CONTACTORS FUSES 2 6 2 2 2 2 2 2 4 2 4 2 4 4 4 4 4 4 6 4 6 4 6 6
6 6 6 6 6 6 12 6 12 6 12 12 12 12 12 12 18 12 18 12 18 18
45
9
5000
217
125
188
109
163
94
54
6
18
54
9
6000
260
150
225
130
195
113
65
6
18
RECOVERY CAPACITIES
Recovery in U.S. Gallons/Hr. (GPH) and Liters/Hr. (LPH) at Various Temperature Rises
INPUT EQUIVALENT RECOVERY CAPACITIES KW BTU/H UNITS
40°F (22°C)
50°F (28°C)
60°F (33°C)
70°F (39°C)
80°F (45°C)
90°F (50°C)
100°F (56°C)
110°F (61°C)
120°F (67°C)
130°F (72°C)
140°F (78°C)
GPH
62 40°F 235 (22°C) 93 62 352 235 124 93 470 352 155 124 587 470 186 155 705 587 248 186 939 705 279 248 1057 939 310 279 1174 1057 372 310 1409 1174 465 372 1761 1409 558 465 2114 1761
50 50°F 188 (28°C) 74 50 282 188 99 74 376 282 124 99 470 376 149 124 564 470 199 149 751 564 223 199 845 751 248 223 939 845 298 248 1127 939 342 298 1409 1127 447 342 1691 1409
41 60°F 157 (33°C) 62 41 235 157 83 62 313 235 103 83 391 313 124 103 470 391 165 124 626 470 186 165 705 626 207 186 783 705 248 207 939 783 310 248 1174 939 372 310 1409 1174
35 70°F 134 (39°C) 53 35 201 134 71 53 268 201 89 71 335 268 106 89 403 335 142 106 537 403 160 142 604 537 177 160 671 604 213 177 805 671 266 213 1006 805 319 266 1208 1006
31 80°F 117 (45°C) 47 31 176 117 62 47 235 176 78 62 294 235 93 78 352 294 124 93 470 352 140 124 548 470 155 140 587 548 186 155 705 587 233 186 881 705 279 233 1057 881
28 90°F 104 (50°C) 41 28 157 104 55 41 209 157 69 55 261 209 83 69 313 261 110 83 417 313 124 110 470 417 138 124 522 470 165 138 626 522 207 165 783 626 248 207 939 783
25 100°F 94 (56°C) 37 25 141 94 50 37 188 141 62 50 235 188 74 62 282 235 99 74 376 282 112 99 423 376 124 112 470 423 149 124 564 470 186 149 705 564 223 186 845 705
23 110°F 85 (61°C) 34 23 128 85 45 34 171 128 56 45 213 171 68 56 256 213 90 68 342 256 102 90 384 342 113 102 427 384 135 113 512 427 169 135 640 512 203 169 769 640
21 120°F 78 (67°C) 31 21 117 78 41 31 157 117 52 41 196 157 62 52 235 196 83 62 313 235 93 83 352 313 103 93 391 352 124 103 470 391 155 124 587 470 186 155 705 587
19 130°F 72 (72°C) 29 19 108 72 38 29 145 108 48 38 181 145 57 48 217 181 76 57 289 217 86 76 325 289 95 86 361 325 115 95 434 361 143 115 542 434 172 143 650 542
18 140°F 67 (78°C) 27 18 101 67 35 27 134 101 44 35 168 134 53 44 201 168 71 53 268 201 80 71 302 268 89 80 335 302 106 89 403 335 133 106 503 403 160 133 604 503
Recovery in U.S. Gallons/Hr. (GPH) and Liters/Hr. (LPH) at Various Temperature Rises 6 INPUT KW
20,473 EQUIVALENT BTU/H
9 6
30,710 20,473
12 9
40,946 30,710
15 12
51,183 40,946
18 15
61,420 51,183
24 18
81,893 61,420
27 24
92,129 81,893
30 27
102,366 92,129
36 30
122,839 102,366
45 36
153,549 122,839
54 45
184,259 153,549
54
LPH UNITS GPH GPH LPH LPH GPH GPH LPH LPH GPH GPH LPH LPH GPH GPH LPH LPH GPH GPH LPH LPH GPH GPH LPH LPH GPH GPH LPH LPH GPH GPH LPH LPH GPH GPH LPH LPH GPH GPH LPH LPH
GPH 558 447 372 319 279 248 223 203 186 172 184,259 In keeping with its policy of continuous progress product improvement, reserves the right845 to make changes without LPH 2114 and 1691 1409 1208 Rheem 1057 939 769 705 notice. 650
160 604
Rheem Manufacturing MEA FZE Dubai Airport Free Zone - Dubai, UAE www.rheem-mea.com I N T E G RAT E D HOME H O M E COMFORTT C O M F O RT IINTEGRATED
I
w
Commercial Electric INTEGRATED H O M E C O M F O RT Water Booster Water Heater Commercial Electric INTEGRAT ED H O M E C O M F O RT Water Booster Water Heaters
Recommended Specifications Water heater(s) shall be model ____________________, manufactured by RHEEM-RUUD, having electrical input of __________ kW and a recovery rate of _____________ GPH at a 100°F temperature rise. Water heater(s) shall have a storage capacity of 10 gallons. Water heater(s) shall have the UL seal of certification and be factory equipped with an AGA/ ASME rated temperature and pressure relief valve. Tank(s) shall have a unique coating of high temperature porcelain enamel and furnished with magnesium anode rods rigidly supported. Water heater(s) shall meet or exceed the efficiency requirements of ASHRAE. Tank(s) shall have a working pressure rating of 150 psi, and shall be completely assembled.
Water heater(s) shall be approve-listed and constructed in accordance with UL Sanitation (NSF5). Water heater(s) shall be equipped with “screw-in” type elements. Water heater(s) shall be constructed with a SYSTEM SENTINEL element diagnostic panel utilizing light emitting diodes. Each LED will correspond to the number and location of the heating elements and monitor their on-off function. Water heater(s) shall be provided with internal power circuit fusing, control circuit fusing, magnetic contactors, 120 volt control circuit transformer and immersion thermostat(s) with manual reset high limit control. 1-1/4" inlet and outlet water connections shall be provided. Water heater(s) shall be covered by a three year limited warranty against tank leaks.
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Manufacturing MEA FZE Dubai Zone - Dubai, In keeping with its policy of continuous progress and Airport product Free improvement, RheemUAE reserves the right to make changes without notice. www.rheem-mea.com Rheem Water Heating • 101 Bell Road Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1 I N T E G RAT E D HOME H O M E COMFORTT C O M F O RT IINTEGRATED Montgomery, Alabama 36117-4305 • www.rheem.comI Brampton, Ontario L6Y 0P5 • www.rheem.com IIN T EEGGRAT OIM OM NT RATEEDDHA RE&CW AF TO E RT R
w
4