Electric Products, Inc. Quality Weatherproof Electrical Equipment
RV product catalog
MEPC-RV09
Midwest Electric Products, Inc. P.O. Box 910 Mankato, MN 56002-0910
Customer Service Phone: (507) 345-2505 Customer Service Fax: (507) 345-2530 www.midwestelectric.com
How to Use This Catalog Midwest Electric Products, Inc., is pleased to introduce our Recreational Vehicle product catalog. The product alphanumeric list is found on page 5.
Each model number is described in the following manner within its respective section:
Example Model Layout Drawing
Model Layout Drawing An easy-to-understand diagram that illustrates the internal component configuration.
Model Data Table The table is located on the same page as the Model Layout Drawing. This table thoroughly defines each model, as well as all necessary ordering information. These tables may vary slightly between sections to best describe each product line.
Technical Data Table
5-20R2GFI
Following the Model Data Tables and Model Layout Drawings, we have included a table at the end of each section that defines specific information including replacement parts, cabinet dimensions, enclosure styles, and knockout configurations.
(2) 14-50R
A M004C010
Example Model Data Table
FIG. UL A
Y
MODEL NUMBER RING TYPE
RINGLESS
M004C010
——
RECEPTACLES
CIRCUIT PROTECTION (2) CB250 CB120
5-20R2GFI (2) 14-50R
AMP VOLTS 100
120/240
WIRE CABINET HUB LOAD & UNIT STD. RANGE* SIZE OPENING NEUTRAL BAR WT. PKG. AA
9 X 30
Y
LC55N1
26
Example Technical Data Table (found at the end of each product section)
REPLACEMENT PARTS MODEL NUMBER
M004C010
2
HUB OPENING
CABINET DIMENSIONS
METER SOCKET
POST LUGS
CABINET SIZE page
MSM100930
——
9 X 30
ENCLOSURE STYLE page
HEIGHT
WIDTH
DEPTH
A
B
C
KNOCKOUT FIGURE page
B
30"
9-3/4"
5-3/16"
2
1
How to Use This Catalog Model Diagram Symbol Key Meter Socket
Circuit Breaker space: 2-pole Plug-In Style
Circuit Breaker Installed: 1-pole Plug-In Style
GE - KR Style Main Breaker
Circuit Breaker Installed: 2-pole Plug-In Style
SPACE
GE - KR Style Main Breaker Space
Circuit Breaker space: 1-pole Plug-In Style
For Receptacle Identification.
Timer
Lug
See Application Data
Model Number System Key Model Numbers are based on the following system: Example: Model Number U041CP6010
unmetered
0
4
1
series number
{
U METERING M = Ring-Type Meter Socket R = Ringless Meter Socket
SERIES NUMBER Assigned by Midwest
U = Unmetered
C
P6
010
circuit breaker
Earth Burial Post
Options
POST OPTIONS B4 = Back to Back Pad Mounted Post
010 = GFCI Duplex Receptacle
B6 = Back to Back Earth Burial Post
031 = GFCI Duplex Receptacle; TV/Tel
H = Head Post Design
033 = GFI Breaker (Double Pole); GFCI Duplex Receptacle
TYPE OF PROTECTION
HP = Head Post Design
C = Circuit Breaker installed
P4 = Pad Mounted Post
E = Empty Spaces for FieldInstalled Breakers
P6 = Earth Burial Post
F = Fused G = Ground Fault Breaker Protection H = Hybrid: Combination of Different Protection EXAMPLE: Fuse/Switch
OPTIONS
034 = Meter with Lever Bypass
R1 = Vertical Barrier for Meter 039 = 350 MCM Lugs Compartment (Top & Bottom) L10 = Lighted with GFCI R2 = Horizontal Barrier Between Receptacles Meter and Circuit Breaker L31 = Lighted with Compartments. Vertical TV/Tel Barriers in Both Meter and Circuit Breaker Compartments.
P = Puller, Non-Fused
S4 = Stud Termination Pad Mounted Post
T = Circuit Breaker with Triple Tap Lugs
S6 = Stud Termination Earth Burial Post TL = Twin Lugs Per Phase (Loopfeed for Surface Mount Units) W4 = Back to Back, Stud Termination Pad Mounted Post W6 = Back to Back, Stud Termination Earth Burial Post B1 = Barrier (Bottom)
3
Product Features and Warranty All equipment manufactured by Midwest Electric Products, Inc. , contains a label located on the inside of the door which gives electrical data and wiring information for the unit. On
select models the label also lists the renewal parts for the unit. Pictured below is a sample label.
TYPICAL WIRING DIAGRAM BOND WHEN USED AS SERVICE EQUIPMENT. (CONNECT TO ANY OPEN SIDE OR END HOLE ON NEUTRAL.) - LINE -
LOOP FEED INSUL. NEUTRAL
S P A C E
BONDING JUMPER
RAINPROOF POWER OUTLET LISTED POWER OUTLET B6FL
SUITABLE FOR USE AS RECREATIONAL VEHICLE SITE SUPPLY EQUIPMENT. IF USED AS RECREATIONAL VEHICLE SITE SUPPLY EQUIPMENT, DO NOT BOND NEUTRAL.
EQUIP. GRD.
TEST MONTHLY
- LOAD RECEPT. GRD. IF FEED-THROUGH CIRCUIT IS UTILIZED FIELD WIRE FROM “LOAD” TERMINALS.
GROUND FAULT PROTECTED - WARNING: PERSONS CONTACTING MORE THAN ONE LEG OF THE CIRCUIT AT THE SAME TIME ARE NOT PROTECTED.
USE COPPER WIRE ONLY EXCEPT LINE, NEUTRAL AND EQUIPMENT GROUND TERMINALS ARE SUITABLE FOR CU OR AL CONDUCTORS.
MODEL NO.
U075CTL010
100 AMPS MAX. 120/240 VOLTS A - C 3 WIRE, 1 PHASE TYPE 3R ENCLOSURE
USE ONLY 80 DEG. C (140 DEG.F) CONDUCTORS ON ALL FIELD INSTALLED LINE, LOAD AND NEUTRAL TERMINATIONS. THE FOLLOWING GFCI RECEPTACLES MAY BE UTILIZED IN THIS EQUIPMENT: ARROW HART: CAT NOS. GF6242 AND GF6342. LEVITON: CAT NOS. 6803, 6899, 6580, AND 6589. ADDITIONAL CIRCUIT BREAKER SPACE PROVIDED FOR (1): G.E. TYPE THQL 20 AMP MAX. SINGLE -POLE, ITE/SIEMENS TYPE Q OR CUTLER HAMMER/BRYANT/WESTINGHOUSE TYPE BR. OVER CURRENT PROTECTION IF BREAKER TRIPS, HANDLE WILL BE IN INTERMEDIATE POSITION. TO RESTORE SERVICE; 1. MOVE HANDLE TO “OFF” POSITION, 2. THEN TO “ON” POSITION. LUG TIGHTENING TORQUE (LB - IN) SCREW TYPE
WIRE SIZE 14-10 8 8-4 3-2/0
SLOTTED
WARNING: TO AVOID ACCIDENTAL CONTACT WITH LIVE PARTS, CLOSE ALL OPENINGS WITH BREAKERS OR FILLER PLATES: CAT. NO. 265A5003P1 FOR (1) POLE FILLER PLATE. ALUMINUM TERMINATIONS: TO HELP GUARD AGAINST OVERHEATING WHEN CONNECTING ALUMINUM WIRE IN CU/AL LUG, REMOVE OXIDE FILM FROM WIRE AND PROTECT IT WITH OXIDE INHIBITING COMPOUND. TEST PROCEDURE FOR GFCI RECEPTACLE 1. PUSH TEST BUTTON. RESET BUTTON SHOULD POP OUT FROM INNERSURFACE. THIS SHOULD RESULT IN POWER BEING OFF AT ALL OUTLETS PROTECTED BY THE GFCI. VERIFY BY PLUGGING TEST LAMP INTO EVERY SUCH OUTLET. IF YOUR GFCI HAS AN INDICATOR LIGHT, THIS LIGHT SHOULD BE ON WHEN CIRCUIT IS COMPLETE. TEST WITH TEST LAMP TO DETERMINE CONDITION OF CIRCUIT AND PROPER OPERATION OF INDICATOR LIGHT. CAUTION: IF RESET BUTTON DOES NOT POP OUT OR IF TEST LAMP OR INDICATOR LIGHT REMAINS LIT WHEN RESET BUTTON DOES POP OUT, DO NOT USE ANY OUTLETS ON THE CIRCUIT. CALL A QUALIFIED ELECTRICIAN. 2. IF THE GFCI TEST OKAY, RESTORE POWER BY PUSHING THE RESET BUTTON BACK IN. THE RESET BUTTON MUST BE PUSHED FIRMLY AND FULLY INTO PLACE UNTIL IT LOCKS AND REMAINS DEPRESSED AFTER PRESSURE HAS BEEN REMOVED. IF THE GFCI FAILS TO RESET PROPERLY, DO NOT USE - CALL A QUALIFIED ELECTRICIAN. TEST LAMP AND/OR INDICATOR LIGHT SHOULD AGAIN LIGHT PROPERLY, DO NOT USE - CALL A QUALIFIED ELECTRICIAN. TEST LAMP AND/OR INDICATOR LIGHT SHOULD AGAIN LIGHT. SHORT CIRCUIT CURRENT RATING OF THIS POWER OUTLET IS 10,000 RMS SYMMETRICAL AMPERES, 240 VOLTS AC MAX., THE BREAKER SHALL HAVE MINIMUM INTERRUPTING RATING OF 10,000 AMPS RMS. ADDITIONAL OR REPLACEMENT CIRCUIT BREAKERS SHALL BE OF THE SAME MANUFACTURER AND TYPE DESIGNATION AND SHALL HAVE AN EQUAL OR GREATER SHORT CIRCUIT CURRENT RATING.
TORQUE 32-95 36-40 40-45 45-50
WIRE RANGE CONNECTOR
COPPER SOLID STRD 14-8 14-1/0 14-10 14-10 12-8 12-1/0 14-8 14-4 12-8 12-2
LINE - CB BASIC JL - LOOP LOAD - PLUG/DUPLEX NEUTRAL - LARGE HOLE NEUTRAL - SMALL HOLE EQUIPMENT GRD. - GL3
ALUMINUM SOLID STRD 12-8 12-1/0 --------12-8 10-1/0 12-8 12-4 12-8 12-2
WHEN CABINET HAS PROVISIONS FOR A CONDUIT HUB. SELECT FROM THE CHART BELOW:
CONDUIT SIZE CAT. NO.
CLOSURE CAP B01
3/4
1
1-1/4
1-1/2
B07
B10
B12
B15
DANGER HAZARD OF ELECTRICAL SHOCK OR BURN. TURN OFF POWER BEFORE WORKING INSIDE THIS EQUIPMENT.
MIDWEST ELECTRIC PRODUCTS, INC. P.O. BOX 910 MANKATO, MN 56002-0910 WWW.MIDWESTELECTRIC.COM
MNP600737 XXXXX
Warranty MIDWEST ELECTRIC PRODUCTS, INC. The Company warrants to the Purchaser that the equipment to be delivered hereunder will be free from defects in material or workmanship and will be of the kind and quality designated or specified in the contract. This warranty shall apply only to defects appearing within one year from the date of shipment by the company. If the equipment delivered hereunder does not meet the above warranty, and if the Purchaser promptly notifies the Company, the Company shall thereupon correct any defect including nonconformance with the specifications either (at its option), by repairing any defective or damaged parts of the equipment, or by making available at the Company's plant necessary repaired or replacement parts. The liability of the Company under this warranty (except as to title), or for any loss or damage to the equipment whether the claim is based on contract or negligence, shall not in any case exceed the cost of correcting defects in the equipment as herein provided and upon the expiration of the warranty period all such liability shall terminate. The foregoing shall constitute the exclusive remedy of the Purchaser and the exclusive liability of the Company. The foregoing warranty is exclusive and in lieu of all other warranties, whether written, oral, implied, or statutory (except as to title). NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR PURPOSE SHALL APPLY. The Company does not warrant any equipment of other manufacture designated by the Purchaser.
4
Alpha-Numeric Index Model Number
Page No.
121 ..................................................33 131 ..................................................33 265A5003P1 ...................................33 265A5003P2 ...................................33 520R2 .............................................32 520R2GFI .......................................32 AD2030 ...........................................32 AD3020 ...........................................32 AD5020 ...........................................32 ASR1 ..............................................33 B01 .................................................33 B07 .................................................33 B10 .................................................33 B12 .................................................33 B15 .................................................33 B20 .................................................33 B25 .................................................33 BR32U ............................................32 BR33 ...............................................32 BR34 ...............................................32 BR53 ...............................................32 BR54U ............................................32 BR64U ............................................32 C32U...............................................32 C33 .................................................32 C34 .................................................32 C53 .................................................32 C54 .................................................32 C54U...............................................32 C64U...............................................32 CLP1 ...............................................34 EK126 .............................................33 EK129 .............................................33 FBEM9 ............................................33 LC1212PC ......................................35 LC33N1...........................................35 LC33N1T ........................................35 LC33N7...........................................35 LC44X1 ...........................................35 LC55N1...........................................35 LC55N1T ........................................35 M004C010 ......................................10 M004CP6010 ..................................14 M031C010 ......................................10 M041C010 ......................................10 M041CB6010 ..................................16 M041CP4010 ..................................14 M041CP4L10 ..................................17 M041CP4L31 ..................................17 M041CP6010 ..................................14 M041CP6L10 ..................................17 M041G ............................................10 M041GB6........................................16 M041GP4........................................14 M041GP6........................................14 M055C010 ......................................10 M055G ............................................10 M055GP6........................................14 M075C010 ......................................10 M075CB4010 ..................................16 M075CB6010 ..................................16 M075CB6031 ..................................16 M075CP4010 ..................................14 M075CP4L10 ..................................17 M075CP4L31 ..................................17 M075CP6010 ..................................14 M075CP6031 ..................................14 M075CP6L10 ..................................17 M075CP6L31 ..................................17 M075CP6L39 ..................................17 M075G ............................................10 M075GB6........................................16 M075GP4........................................15 M075GP6........................................15 M076C010 ......................................10 M355C010 ......................................10 M355CP6010 ..................................15 M355G ............................................10 M355GB6........................................16 M355GP4........................................15 M355GP6........................................15 M355GP6028..................................15 M358CP6 ........................................15 M655GB6........................................16 M655GP6........................................15
Model Number
Page No.
M775CB6010 ..................................16 M775CP6010 ..................................15 MS62 ..............................................33 MSM100930 ...................................35 MSM100P9 .....................................35 MSR100930 ....................................35 MSR100P9 .....................................35 MW200M ........................................35 P5POST..........................................32 P6POST..........................................32 PCAMOTEX....................................33 PBLUE ............................................33 PBLUETEX .....................................33 PBRONZETEX ...............................33 PGRAY61........................................33 PTAN...............................................33 PTANTEX........................................33 PWHITE ..........................................33 PWHITETEX ...................................33 PLK50 .............................................34 PR32U ............................................32 PR33 ...............................................32 PR34 ...............................................32 PR53 ...............................................32 PR54U ............................................32 PR64U ............................................32 R031C010.......................................10 R041C010.......................................10 R041CP6010 ..................................14 R041G ............................................10 R041GB6 ........................................16 R041GP6 ........................................14 R055C010.......................................10 R055G ............................................10 R075C010.......................................10 R075CB6010 ..................................16 R075CP4010 ..................................14 R075CP6010 ..................................14 R075CP6031 ..................................14 R075GB6 ........................................16 R075GP6 ........................................15 R076C010.......................................10 R32U...............................................32 R355CP6010 ..................................15 R355CP6031 ..................................15 R355G ............................................10 R355GP6 ........................................15 SFEM6 ............................................33 SFEM9 ............................................33 SNPR1 ............................................33 SUBSTATION .................................34 TTV100 ...........................................33 U004CB4010 ..................................13 U004CB6010 ..................................13 U004CP4010...................................11 U004CP4031..............................11,19 U004CP6010...................................11 U01 .................................................33 U010C010.........................................8 U010G ..............................................8 U011C010 .........................................8 U011CP4010...................................11 U011CP6010...................................11 U011CTL010.....................................8 U011G...............................................8 U011GB4 ........................................13 U011GB6 ........................................13 U011GP4.........................................11 U011GP6.........................................11 U011GTL...........................................8 U031C010.........................................8 U04 .................................................33 U040G ..............................................8 U040GP4 ........................................11 U040GP6 ........................................11 U040GP6010 ..................................11 U040GTL ..........................................8 U041C010.........................................8 U041CB4010 ..................................13 U041CB4L10 ..................................18 U041CB6010 ..................................13 U041CB6L10 ..................................18 U041CP4010...................................11 U041CP4031...................................11 U041CP4039...................................11
Model Number
Page No.
U041CP4L10 ..................................18 U041CP6010...................................11 U041CP6031..............................11,19 U041CP6039...................................11 U041CP6L10 ..................................18 U041CTL010 ....................................8 U041CTLL10 ..................................17 U041G ..............................................8 U041GB4 ........................................13 U041GB6 ........................................13 U041GP4 ........................................11 U041GP4L ......................................18 U041GP6 ........................................11 U041GP6L ......................................18 U041GTL ..........................................9 U042GB6 ........................................13 U042GP6 ........................................11 U043GP6 ........................................11 U055C010.........................................9 U055CP4010...................................11 U055CP6010...................................11 U055G ..............................................9 U055GB6 ........................................13 U074GTL ..........................................9 U075CB4010 ..................................13 U075CB4031 .............................13,19 U075CB4L10 ..................................18 U075CB6010 ..................................13 U075CB6031 .............................13,19 U075CB6L10 ..................................18 U075CP4010...................................11 U075CP4031..............................11,19 U075CP4L10 ..................................18 U075CP4L31 .............................18,19 U075CP6010...................................11 U075CP6010D ................................11 U075CP6031..............................11,19 U075CP6039...................................11 U075CP6039D ................................11 U075CP6L10 ..................................18 U075CP6L31 .............................18,19 U075CTL010 ....................................9 U075CTLL10 ..................................17 U075GB6 ........................................13 U075GP4 ........................................11 U075GP4L ......................................18 U075GP6 ........................................11 U075GP6019 ..................................11 U075GP6L ......................................18 U075GTL ..........................................9 U076C010.........................................9 U10 .................................................33 U12 .................................................33 U131CP6010 ..................................12 U131CTL010 ....................................9 U15 .................................................33 U175CP6HP010 .............................12 U20 .................................................33 U25 .................................................33 U30 .................................................33 U35 .................................................33 U355C010.........................................9 U355G ..............................................9 U355GP6 ........................................12 U40 .................................................33 U412CP6010 ..................................12 U412G ..............................................9 U412GP6 ........................................12 U611CB4010...................................13 U611CB6010...................................13 U611CP4010...................................12 U611CP6010...................................12 U611CTL010.....................................9 U611GTL...........................................9 U775C010.........................................9 U775CP4010 ..................................12 U775CP6010 ..................................12 UH11AL...........................................34 UH12AL ..........................................34 UH20GG .........................................34 UH90G ............................................34 UH90GT..........................................34 UH90ST ..........................................34 UWATER34.....................................34
Search e-Catalog for More Products Online at http://www.midwestelectric.com
5
Available Models
RV Park Equipment RV Metallic
pg. 7
-
Painted galvanized steel Surface mounts available Metered, unmetered, lighted, and TV/Tel available RV Equipment available factory assembled on a padmount or earth-burial post for underground services - 200-Amp Loop Feed lugs have twin 2-250 MCM minimum terminals per phase Cu/Al - All components are factory wired and assembled, reducing installation time - Single or Double-sided models available - Padlock provision can prevent unauthorized entry - UL listed
PARKMATETM
pg. 27
- Wide array of accessories: light, photoelectric sensor, telephone, cable TV connections, and electronic metering - VALOX thermoplastic enclosure and internal components are corrosion resistant - Post is galvanized or stainless steel - Factory wired power receptacles are available in 20, 30, or 50 Amp configurations, protected by thermal magnetic circuit breakers. Ground fault breakers are also available - Surface, earth burial, or padmount post available - Single or Double-sided models available - Pedestal features 350 MCM minimum loop feed lugs - UL listed
PARKRANGERTM
pg. 30
- Specific to padmount - Corrosion resistant Non-Metallic power pedestal - Wide array of accessories: light, photoelectric sensor, telephone, cable TV connections, and electronic metering - Factory wired power receptacles are available in 20, 30, 50, or 100 Amp configurations, protected by thermal magnetic circuit breakers. Ground fault breakers are also available - Single or Double-sided models available - Base module with loop feed terminal bar 350 MCM - UL listed
REMOTE METERING PACKAGES AVAILABLE CONSULT MANUFACTURER
(( ((( 6
(((
(( Data subject to change without notice.
Application Information
RV Park Equipment
Today, most recreational vehicle parks provide power for their tenants. This application presents unique requirements including user safety, rugged construction, weather protection, receptacle versatility, and attractiveness. Midwest Electric offers a complete line of power outlet products for RV Park applications including standard power outlets, post mounted units, and metered models for both surface and pedestal units.
The 2002 National Electric Code Requires: 551-71. Type Receptacles Provided. Every recreational vehicle site with electrical supply shall be equipped with at least one 20-ampere, 125-volt receptacle. A minimum of 5 percent of all recreational vehicle sites with electrical supply, shall each be equipped with a 50-ampere, 125/250 volt receptacle conforming to the configuration as identified in Figure 551-46(c). These electrical supplies shall be permitted to include additional receptacles that have configurations in accordance with Section 551-81. A minimum of 70 percent of all recreational vehicle sites with electrical supply shall each be equipped with a 30-ampere, 125-volt receptacle conforming to Figure 551-46(c). This supply shall be permitted to include additional receptacle configurations conforming to Section 551-81. The remainder of all recreational vehicle sites with electrical supply shall be equipped with one or more of the receptacle configurations conforming to Section 551-81. Dedicated tent sites with a 15- or 20ampere electrical supply shall be permitted to be excluded when determining the percentage of recreational vehicle sites with 30- or 50-ampere receptacles. Additional receptacles shall be permitted for the connection of electrical equipment outside the recreational vehicle within the recreational vehicle park.
Recreational Vehicle Parks are typically wired using either a loop-feed or radial-feed system as illustrated on this page. The most popular, and generally most economical, is the loop-feed system where each feeder services a single power outlet. Midwest Electric offers a complete line of power outlets for recreational vehicle park application that meet the National Electrical Code: standard power outlets, post mounted power outlets (completely factory assembled and wired with loop-feed lugs in the post) and metered power outlets (ring-type and ringless). Also listed are surface mounted models with twin lugs per phase ideal for overhead loop-feed systems. Midwest offers both the traditional metallic equipment and the ParkMate and ParkRanger series of non-metallic thermoplastic units. Midwest has the unit for your unique application.
Figure 551-46(c) Transformer
Transformer
All 125-volt, single-phase, 15- and 20-ampere receptacles shall have listed ground-fault circuit-interrupter protection for personnel. Figure 551-46(c). Configurations for grounding-type receptacles and attachment plug caps used for recreational vehicle supply cords and recreational vehicle lots. 551-77(b). Disconnecting Means. A disconnecting switch or circuit breaker shall be provided in the site supply equipment for disconnecting the power supply to the recreational vehicle.
Loop-Feed System
Radial-Feed System
Features and Benefits Rugged Durability • All-In-One construction for factory assured terminations • Rolled edge door for cord protection • Heavy (16 gauge) galvanized zinc-coated steel with highest quality electro-deposition finish – resists corrosion and fading • Welded flange NEMA 3R construction for lasting service in outdoor installations Installation Ease • All components are factory wired and assembled, reducing installation time • Door has stay-open position for user convenience • All terminals accept copper or aluminum wire for added installation flexibility • Wide range of receptacle configurations • Broad range of concentric knock-outs to accommodate wiring needs • All units with 12-2 Cu/Al equipment ground lug • 10,000 AIC Data subject to change without notice.
Posts • Recreational vehicle park equipment available factory assembled on a padmount or earth-burial post for underground services. • Factory wired from loop-feed lugs, located in the post to receptacles, reducing installation time • 200 Amp Loop-feed lugs have twin 2-250 MCM terminals minimum per phase, Cu/Al (some models available up to 350 MCM) • Rolled edge post bottoms to protect service cable • Post door removable for installation ease User Safety • Listed by Underwriters Laboratories, a safety plus • Padlock provision can prevent unauthorized entry • Dead front construction prevents accidental contact with live parts
7
Surface - Unmetered
RV Park Equipment
20 20
20
20
GFI
S P A C E
20 20
S P A C E
20 20 GFI GFI
S P A C E
S P 20 20 AC GFI GFI E
5-20R2GFCI
5-20R2
(2) 5-20R2GFCI
(2) 5-20R2GFCI
(2) 5-20R2
(2) 5-20R2
A U010C010
B U010G
C U011C010
D U011CTL010
E U011G
F U011GTL
S P A 30 20 C GFI GFI E
S P 30 20 AC GFI GFI E
(2) 5-20R2GFCI
R32U
R32U
G U031C010
FIG. UL
LUG TYPE
BR32U
5-20R2
H U040G
MODEL NUMBER
A
Y
STANDARD
U010C010
B
Y
STANDARD
U010G
30 20
R32U
5-20R2
I U040GTL
S P A C E
30 20
5-20R2GFCI
J U041C010
BR32U
S P A C E
S P A C E
30 20 GFI
5-20R2GFCI
R32U
K U041CTL010
5-20R2
L U041G
CIRCUIT PROTECTION
AMP
VOLTS
5-20R2GFCI
CB120
20
120
B
6X9
Y
——
7
4
5-20R2
GFI120
20
120
B
6X9
Y
——
7
4
(2) CB120 SPACE CB120
70
120/240
P
6 X 14
Y
LC33N7
10
100
120/140
W
9 X 17
Y
LC33N1T
14
RECEPTACLES
WIRE CABINET HUB LOAD & UNIT STD. RANGE* SIZE OPENING NEUTRAL BAR WT. PKG.
4
C
Y
STANDARD
U011C010
(2) 5-20R2GFCI
D
Y
LOOP FEED
U011CTL010
(2) 5-20R2GFCI
E
Y
STANDARD
U011G
(2) 5-20R2
(2) GFI120 SPACE CB120
70
120/240
P
6 X 14
Y
LC33N7
10
F
Y
LOOP FEED
U011GTL
(2) 5-20R2
(2) GFI120 SPACE CB120
100
120/240
W
9 X 17
Y
LC33N1T
14
1
G
Y
STANDARD
U031C010
R32U (2) 5-20R2GFCI
CB130, (2) CB120 100 SPACE (2) CB120
120/240
AA
9 X 17
Y
LC55N1
16
1
H
Y
STANDARD
U040G
R32U 5-20R2
GFI130 GFI120 SPACE CB120
70
120/240
P
6 X 14
Y
LC33N7
10
4
I
Y
LOOP FEED
U040GTL
BR32U 5-20R2
GFI130 GFI120 SPACE CB120
100
120/240
W
9 X 17
Y
LC33N1T
14
1
J
Y
STANDARD
U041C010
R32U 5-20R2GFCI
CB130 CB120 SPACE CB120
70
120/240
P
6 x 14
Y
LC33N7
10
4
K
Y
LOOP FEED
U041CTL010
BR32U 5-20R2GFCI
CB130 CB120 SPACE CB120
100
120/240
W
9 x 17
Y
LC33N1T
14
1
L
Y
STANDARD
U041G
R32U 5-20R2
CB130 GFI120 SPACE CB120
70
120/240
P
6 x 14
Y
LC33N7
10
4
(2) CB120 SPACE CB120
1 4
* Wire Range Table on page 25
8
Data subject to change without notice.
Surface - Unmetered
RV Park Equipment
30 20 GFI
BR32U
S P A C E
50
5-20R2
A U041GTL
14-50R
20
20
GFI
5-20R2GFCI
B U055C010
50
S P 30 20 AC GFI GFI E
50
14-50R
50 30 20
50
14-50R, BR32U, 5-20R2GFCI
5-20R2
D U074GTL
C U055G
S P A C E
S P 20 AC GFI E
30
14-50R, BR32U, 5-20R2
E U075CTL010
F U075GTL
50
S P A C E
20 20
14-50R, (2) 5-20R2GFCI
G U076C010
50A
20 30 30 20
S P A C E
50
20
S P A C E
S P A C E
SPACE
20
50
GFI
50A
30 30 20
30 20 20
30 30 20
GFI GFI
20A 30A
GFI
(2) BR32U (2) BR32U 5-20R2GFCI 5-20R2GFCI
H U131CTL010
FIG. UL
LUG TYPE
(2) BR32U 14-50R
5-20R2GFCI
I U355C010
MODEL NUMBER
14-50R
5-20R2
J U355G
BR32U
(2) 5-20R2
K U412G
5-20R2GFCI
5-20R2
L U611CTL010
RECEPTACLES
CIRCUIT PROTECTION
AMP
VOLTS
M U611GTL
R32U (2) 14-50R
5-20R2GFCI
N U775C010
WIRE CABINET HUB LOAD & UNIT STD. RANGE* SIZE OPENING NEUTRAL BAR WT. PKG.
A
Y
LOOP FEED
U041GTL
BR32U 5-20R2
CB130 GFI120 SPACE CB120
100
120/240
W
9 x 17
Y
LC33N1T
14
1
B
Y
STANDARD
U055C010
14-50R 5-20R2GFCI
CB250 CB120
70
120/240
P
6 X 14
Y
LC33N7
10
4
14-50R 5-20R2
CB250 GFI120
70
120/240
P
6 X 14
Y
LC33N7
10
4
14-50R R32U 5-20R2 14-50R R32U 5-20R2GFCI 14-50R R32U 5-20R2
CB250, GFI130 GFI120 SPACE CB120 CB250, CB130 CB120 SPACE CB120 CB250, CB130 GFI120 SPACE CB120
100
120/240
W
9 x 17
Y
LC55N1T
16
1
100
120/240
W
9 x 17
Y
LC55N1T
16
1
100
120/240
W
9 x 17
Y
LC55N1T
16
1
C
Y
STANDARD
U055G
D
Y
LOOP FEED
U074GTL
E
Y
LOOP FEED
U075CTL010
F
Y
LOOP FEED
U075GTL
G
Y
STANDARD
U076C010
14-50R (2) 5-20R2GFCI
CB250 (2) CB120 SPACE CB120
100
120/240
U
9 x 17
Y
LC55N1
16
1
H
Y
LOOP FEED
U131CTL010
(2) 5-20R2GFCI (2) BR32U
(2) CB120 (2) CB130 SPACE CB120
100
120/240
U
14 X 21
Y
LC55N1T
28
1
I
Y
STANDARD
U355C010
14-50R 5-20R2GFCI
CB250, CB120 (2 SPACES 100A MAX)
100
120/240
U
9 X 17
Y
LC55N1
16
1
J
Y
STANDARD
U355G
14-50R 5-20R2
CB250, GFI120 (2 SPACES 100A MAX)
100
120/240
U
9 X 17
Y
LC55N1
15
1
K
Y
STANDARD
U412G
BR32U (2) 5-20R2
CB130 (2) GFI120
70
120/240
U
9 X 17
Y
LC33N1
16
1
L
Y
LOOP FEED
U611CTL010
(2) BR32U 5-20R2GFCI
(2) CB130 CB120
80
120/240
W
9 X 17
Y
LC33N1T
16
1
M
Y
LOOP FEED
U611GTL
(2) BR32U 5-20R2
(2) CB130 GFI120
80
120/240
W
9 X 17
Y
LC33N1T
15
1
N
Y
STANDARD
U775C010
(2) 14-50R BR32U 5-20R2GFCI
(2) CB250T CB130 CB120T
125
120/240
W
9 X 17
Y
——
15
1
* Wire Range Table on page 25 Data subject to change without notice.
9
Surface - Metered
RV Park Equipment
50
20
5-20R2GFCI
30 20
50
(2) 14-50R
R32U
A M004C010
B M031C010 R031C010
50
30 20
S P A C E
14-50R, BR32U 5-20R2GFCI
G M075C010 R075C010
FIG. UL
MODEL NUMBER RING TYPE RINGLESS
A
Y
M004C010
B
Y
M031C010
BR32U
(2) 5-20R2GFCI
—— R031C010
50
S P A C E
S P A GFI C E
30 20
BR32U
5-20R2GFCI
30
50
20 20
14-50R, BR32U, 5-20R
14-50R, (2) 5-20R2GFCI
H M075G
I M076C010 R076C010
RECEPTACLES
CIRCUIT PROTECTION
5-20R2GFCI (2) 14-50R
(2) CB250 CB120
(2) 5-20R2GFCI
5-20R2
S P A C E
50
20
20 GFI
14-50R
14-50R
5-20R2GFCI
50
14-50R
20
S P A C E
S P A C E
14-50R
S P A C E
5-20R2
K M355G R355G
J M355C010
AMP VOLTS
S P A 20 C GFI E
50
5-20R2GFCI
5-20R2
F M055G R055G
E M055C010 R055C010
D M041G R041G
C M041C010 R041C010
S P 20 AC GFI E
50
WIRE CABINET HUB LOAD & UNIT STD. RANGE* SIZE OPENING NEUTRAL BAR WT. PKG.
100
120/240
AA
9 X 30
Y
LC55N1
26
1
(2) SPACE CB120 100
120/240
AA
9 X 30
Y
LC55N1
25
1
BR32U 5-20R2GFCI
CB130 CB120 SPACE CB120
100
120/240
AA
9 X 30
Y
LC33N1
24
1
BR32U 5-20R2
CB130 GFI120 SPACE CB120
100
120/240
AA
9 X 30
Y
LC33N1
25
1
14-50R 5-20R2GFCI
CB250 CB120
70
120/240
AA
9 X 30
Y
LC33N1
25
1
14-50R 5-20R2
CB250 GFI120
70
120/240
AA
9 X 30
Y
LC33N1
25
1
C
Y
M041C010
R041C010
D
Y
M041G
R041G
E
Y
M055C010
R055C010
F
Y
M055G
R055G
G
Y
M075C010
R075C010
14-50R BR32U 5-20R2GFCI
CB250, CB130 CB120 SPACE CB120
100
120/240
AA
9 X 30
Y
LC55N1
25
1
H
Y
M075G
——
14-50R BR32U 5-20R2
CB250, CB130 GFI120 SPACE CB120
100
120/240
AA
9 X 30
Y
LC55N1
25
1
I
Y
M076C010
14-50R (2) 5-20R2GFCI
CB250 (2) CB120 SPACE CB120
90
120/240
AA
9 X 30
Y
LC55N1
26
1
J
Y
M355C010
14-50R 5-20R2GFCI
CB250, CB120 (2) SPACE CB120 100
120/240
AA
9 X 30
Y
LC55N1
25
1
K
Y
M355G
14-50R 5-20R2
CB250 GFI120 100 (2) SPACE CB2100
120/240
AA
9 X 30
Y
LC55N1
25
1
R076C010 —— R355G
* Wire Range Table on page 25
10
Data subject to change without notice.
Pedestal - Unmetered
RV Park Equipment 50
20
20 20
50
S P A C E
S P A C E
20 20 GFI GFI
POST
POST
POST
(2) 14-50R, 5-20R2GFCI
(2) 5-20R2GFCI
(2) 5-20R2
A U004CP6010 U004CP4010
B U011CP6010 U011CP4010
C U011GP6 U011GP4
S P A GFI GFI C E
30 20
POST
POST
30 20
R32U
GFI
5-20R2
D U040GP6 U040GP4
R32U
S P A C E
30 20
S P A C E
30 20 GFI
POST R32U
5-20R2GFCI
E U040GP6010
S P A C E
POST
5-20R2GFCI
F U041CP6010 U041CP4010
R32U
5-20R2
G U041GP6 U041GP4
MAIN
30 30 20
50
GFI
POST 14-50R
20
POST
5-20R2GFI
R32U
5-20R2
I U043GP6
H U042GP6
14-50R
5-20R2GFCI
J U055CP6010 U055CP4010
MODEL NUMBER FIG. UL A
Y
EARTH BURIAL
PADMOUNT
U004CP6010
U004CP4010 %
RECEPTACLES
50
S P A C E
30 20
50
POST
30 20
S P A C E
50
K U075CP6010 U075CP4010
CIRCUIT AMP PROTECTION
14-50R, BR32U, 5-20R2GFCI
14-50R, BR32U, 5-20R2
M U075GP6 U075GP4
L U075CP6010D
VOLTS
GFI
S P A C E
POST
POST
14-50R, BR32U, 5-20R2GFCI
30 20
50
30 20
GFI GFI
S P A C E
POST 14-50R, BR32U, 5-20R2GFCI
N U075GP6019
WIRE CABINET HUB LOAD & UNIT STD. RANGE* SIZE OPENING NEUTRAL BAR WT. PKG.
(2) 14-50R 5-20R2GFCI
(2) CB250 CB120
100
120/240
T2
9PT
N
LC55N1
47
1
(2) 5-20R2GFCI
(2) CB120 SPACE CB120
70
120/240
T2
6PT
N
LC33N7
32
1
B
Y
U011CP6010
U011CP4010
C
Y
U011GP6
U011GP4
(2) 5-20R2
(2) GFI120 SPACE CB120
70
120/240
T2
6PT
N
LC33N7
32
1
D
Y
U040GP6
U040GP4
R32U 5-20R2
GFI130, GFI120, SPACE CB120
70
120/240
T2
9PT
N
LC33N7
32
1
——
R32U 5-20R2GFCI
GFI130, CB120, SPACE CB120
70
120/240
T2
9PT
N
LC33N7
32
1
R32U 5-20R2GFCI
70
120/240
T2
6PT
N
LC33N7
32
1
70
120/240
T2
6PT
N
LC33N7
32
1
E
Y
U040GP6010
F
Y
U041CP6010 % + U041CP4010 % +
G
Y
U041GP6
U041GP4
R32U 5-20R2
CB130 CB120 SPACE CB120 CB130 GFI120 SPACE CB120
H
Y
U042GP6
——
R32U 5-20R2
GFI130 MAIN CB130, CB120
30
120
T2
6PT
N
LC33N7
32
1
I
Y
U043GP6
——
R32U 5-20R2
CB130 MAIN CB130 GFI120
70
120/240
T2
6PT
N
LC33N7
32
1
J
Y
U055CP6010
U055CP4010
K
Y
U075CP6010 %+ U075CP4010 %
L
Y
U075CP6010D P+
M
Y
U075GP6
N
Y
U075GP6019
—— U075GP4 ——
14-50R 5-20R2GFCI 14-50R BR32U 5-20R2GFCI
CB250, CB120
70
120/240
T2
6PT
N
LC33N7
32
1
CB250, CB130 CB120 SPACE CB120
100
120/240
T2
9PT
N
LC55N1
47
1
14-50R BR32U 5-20R2GFCI
CB250, CB130 CB120 SPACE CB120
100
120/240
T2
9PT
N
LC55N1
47
1
100
120/240
T2
9PT
N
LC55N1
47
1
100
120/240
T2
9PT
N
LC55N1
47
1
14-50R, BR32U CB250, CB130 5-20R2 GFI120 14-50R, BR32U CB250, GFI130 5-20R2 GFI120
% Available with factory-installed TV/Telephone, replace “010 with “031” P Post depth dimension is non-standard (4-3/8") + Available w/350 MCM loop lugs, replace “010” with “039”
Data subject to change without notice.
Tv/Tel model diagrams on page 19
* Wire Range Table on page 25
11
Pedestal - Unmetered
RV Park Equipment S P A C E
30 30 20 20
50
S P A GFI C E
(2) BR32U, (2) 5-20R2GFCI
14-50R, R32U, 5-20R2GFCI
A U131CP6010
B U175CP6HP010
14-50R
5-20R2
C U355GP6
MODEL NUMBER EARTH BURIAL
PADMOUNT
RECEPTACLES
50
30 20 20
30 30 20
30 20 20
50 20 30
GFI GFI
POST
POST
POST
FIG. UL
S P A C E
20
BR32U
(2) 5-20R2GFCI
POST BR32U
(2) BR32U
(2) 5-20R2
E U412GP6
D U412CP6010
CIRCUIT PROTECTION
POST
AMP
VOLTS
5-20R2GFCI
POST BR32U (2) 14-50R, 5-20R2GFCI
G U775CP6010 U775CP4010
F U611CP6010 U611CP4010
WIRE CABINET HUB LOAD & UNIT STD. RANGE* SIZE OPENING NEUTRAL BAR WT. PKG.
A
Y
U131CP6010
——
(2) BR32U (2) 5-20R2GFCI
(2) CB130, (2) CB120 100 SPACE CB120
120/240
T2
14PT
N
LC55N1
47
1
B
Y
U175CP6HP010
——
W
14PT
N
——
89
1
Y
U355GP6
——
CB2100 MAIN, CB250 100 CB130, CB120 CB250, GFI120 (2) SPACE CB120 100
120/240
C
14-50R, BR32U 5-20R2GFCI 14-50R 5-20R2
120/240
T2
9PT
N
LC55N1
47
1
D
Y
U412CP6010
——
BR32U (2) 5-20R2GFCI
CB130 (2) CB120
70
120/240
T2
9PT
N
LC33N1
47
1
E
Y
U412GP6
——
BR32U (2) 5-20R2
CB130 (2) GFI120
70
120/240
T2
9PT
N
LC33N1
51
1
F
Y
U611CP6010
U611CP4010
(2) BR32U 5-20R2GFCI
(2) CB130 CB120
80
120/240
T2
9PT
N
LC33N1
47
1
G
Y
U775CP6010
U775CP4010
(2) 14-50R BR32U 5-20R2GFCI
(2) CB250T CB130 CB120T
125
120/240
T2
9PT
N
——
97
1
* Wire Range Table on page 25 PLK50 Replacement deadfront kit with 50-Amp lockout feature for all U075- or M075-series units. Line Drawing on page 34. Consult Manufacturer for details.
12
Data subject to change without notice.
Pedestal - Unmetered
RV Park Equipment
50
20
50
50
20
S P 20 20 AC GFI GFI E
50
S P 20 20 AC GFI GFI E
30 20
POST
POST 5-20R2GFCI (2) 14-50R
50
50
GFI
20
50
GFI
30
30 20
S P A C E
50
30 20
S P A C E
50
30
S P 20 AC GFI E
MAIN
MAIN
30 30 20
30 30 20
GFI
GFI
POST
R32U, 5-20R2
R32U, 5-20R2
D U041GB6 U041GB4
S P A GFI C E
30 20
50
S P A GFI C E
30 30 20
30 30 20
POST (2) BR32U, 5-20R2GFCI
14-50R, BR32U, 5-20R2
H U075GB6
G U075CB6010 U075CB4010
E U042GB6
30 20
POST
14-50R, BR32U, 5-20R2GFCI
F U055GB6
S P 20 AC GFI E
POST
C U041CB6010 U041CB4010
POST
POST 14-50R, 5-20R2
30 20
R32U, 5-20R2GFCI
B U011GB6 U011GB4
20
S P A C E
POST
(2) 5-20R2
A U004CB6010 U004CB4010
S P A C E
I U611CB6010 U611CB4010
Back-to-Back FIG. UL
MODEL NUMBER EARTH BURIAL
PADMOUNT
RECEPTACLES (PER SIDE)
CIRCUIT PROTECTION (PER SIDE)
AMP
VOLTS
(2) 14-50R 5-20R2GFCI
(2) CB250 CB120
100
120/240
S
9PT
N
LC55N1
62
1
(2) 5-20R2
(2) GFI120 SPACE CB120
70
120/240
T2
6PT
N
LC33N7
47
1
R32U 5-20R2GFCI
CB130 CB120 SPACE CB120
70
120/240
T2
6PT
N
LC33N7
47
1
WIRE CABINET HUB LOAD & UNIT STD. RANGE* SIZE OPENING NEUTRAL BAR WT. PKG.
A
Y
U004CB6010
U004CB4010
B
Y
U011GB6
U011GB4
C
Y
U041CB6010
U041CB4010
D
Y
U041GB6
U041GB4
R32U 5-20R2
CB130 GFI120 SPACE CB120
70
120/240
T2
6PT
N
LC33N7
47
1
E
Y
U042GB6
——
R32U 5-20R2
GFI130 MAIN (2) CB120
30
120
T2
6PT
N
LC33N7
47
1
——
14-50R 5-20R2
CB250 GFI120
70
120/240
T2
6PT
N
LC33N7
47
1
14-50R BR32U 5-20R2GFCI
CB250, CB130 CB120 SPACE CB120
100
120/240
S
9PT
N
LC55N1
62
1
14-50R BR32U 5-20R2
CB250, CB130 GFI120 SPACE CB120
100
120/240
S
9PT
N
LC55N1
62
1
(2) BR32U 5-20R2GFCI
(2) CB130 CB120
80
120/240
T2
9PT
N
LC33N1
62
1
F
Y
U055GB6
G
Y
U075CB6010 % U075CB4010 %
H
Y
U075GB6
I
Y
U611CB6010
—— U611CB4010
% Available with added factory-installed TV/Telephone. Replace “010” with “031” See page 19 * Wire Range Table on page 25
Data subject to change without notice.
13
Pedestal - Metered
RV Park Equipment
50
20
30 20
50
S P A C E
S P A GFI C E
50
30 20
POST
POST
POST
BR32U, 5-20R2GFCI
BR32U, 5-20R2
B M041CP6010 M041CP4010 R041CP6010
50
GFI
(2) 14-50R, 5-20R2GFCI
A M004CP6010
20
C M041GP6 M041GP4 R041GP6
S P A C E
POST
POST 14-50R
30 20
5-20R2
14-50R,BR32U,5-20R2GFCI
E M075CP6010 M075CP4010 R075CP6010 R075CP4010
D M055GP6
Earth Burial FIG. UL
MODEL NUMBER RING TYPE
RINGLESS
RECEPTACLES
A
Y
M004CP6010
——
(2) 14-50R 5-20R2GFCI
B
Y
M041CP6010
R041CP6010
BR32U 5-20R2GFCI
C
Y
M041GP6
R041GP6
BR32U 5-20R2
D
Y
M055GP6
——
E
Y
M075CP6010 % R075CP6010 %
CIRCUIT PROTECTION (2) CB250 CB120 CB130 CB120 SPACE CB120
AMP VOLTS
WIRE CABINET HUB LOAD & UNIT STD. RANGE* SIZE OPENING NEUTRAL BAR WT. PKG.
100
120/240
T2
9PT
N
LC88X1
48
1
100
120/240
T2
9PT
N
LC33N1
53
1
CB130 GFI120 SPACE CB120
100
120/240
T2
9PT
N
LC33N1
59
1
14-50R 5-20R2
CB250 GFI120
70
120/240
T2
9PT
N
LC33N1
59
1
14-50R BR32U 5-20RGFCI
CB250, CB130 CB120 SPACE CB120
100
120/240
T2
9PT
N
LC55N1
59
1
Padmount B
Y
M041CP4010
——
BR32U 5-20R2GFCI
CB130 CB120 SPACE CB120
100
120/240
T2
9PT
N
LC33N1
53
1
C
Y
M041GP4
——
BR32U 5-20R2
CB130 GFI120
100
120/240
T2
9PT
N
LC33N1
59
1
14-50R BR32U 5-20RGFCI
CB250, CB130 CB120 SPACE CB120
100
120/240
T2
9PT
N
LC55N1
59
1
E
Y
M075CP4010
R075CP4010
% Available with added factory-installed TV/Telephone in post. Replace “010” with “031”. * Wire Range Table on page 25
14
Data subject to change without notice.
Pedestal - Metered
RV Park Equipment
SPACE
50
S P A GFI C E
S P A C E
30 20
S P A C E
20
20
50
50
GFI
S P A C E
SPACE
S P A C E
50
30
SPACE SPACE
BR32U
POST
POST
POST 14-50R
5-20R2
14-50R, 5-20R2GFCI
14-50R
B M355CP6010 R355CP6010
A M075GP6 R075GP6 M075GP4
R32U
C M355GP6 R355GP6 M355GP4
50 20 30
20 GFI SPACE
POST
POST
5-20R2
50 50
SPACE
5-20R2
14-50R
POST
14-50R
E M655GP6
D M358CP6
BR32U,(2)14-50R,5-20R2GFCI
F M775CP6010
Earth Burial FIG. UL
MODEL NUMBER RING TYPE
RINGLESS
A
Y
M075GP6
R075GP6
B
Y
M355CP6010
R355CP6010 %
C
Y
M355GP6 +
R355GP6
D
Y
M358CP6
——
RECEPTACLES
CIRCUIT PROTECTION
14-50R BR32U 5-20R2
CB250, CB130 GFI120 SPACE CB120
100
120/240
T2
9PT
N
LC55N1
59
1
14-50R 5-20R2GFCI
CB250 CB120 (2) SPACE
100
120/240
T2
9PT
Y
LC55N1
59
1
14-50R 5-20R2
CB250 GFI120 SPACE CB2100
100
120/240
T2
9PT
N
LC55N1
59
1
R32U, 14-50R
CB250, CB130
100
120/240
T2
9PT
N
LC55N1
53
1
200
120/240
T2
14PT
N
LC1212PC
89
1
AMP VOLTS
WIRE CABINET HUB LOAD & UNIT STD. RANGE* SIZE OPENING NEUTRAL BAR WT. PKG.
E
Y
M655GP6
——
14-50R 5-20R2
CB250, GFI120 SPACE CB2200B SPACE (5) CB120 200A. MAX
F
Y
M775CP6010
——
(2) 14-50R BR32U 5-20R2GFCI
(2) CB250T CB130 CB120T
125
120/240
T2
9PT
N
——
59
1
Padmount A
Y
M075GP4
——
14-50R BR32U 5-20R2
CB250, CB130 GFI120 SPACE CB120
100
120/240
T2
9PT
N
LC55N1
59
1
C
Y
M355GP4
——
14-50R 5-20R2
CB250 GFI120 SPACE CB2100
100
120/240
T2
9PT
N
LC55N1
59
1
% Available with factory-installed TV/Telephone in post. Replace “010” with “031”. + Available with Penta-head kit installed, 9" or 14" post. Order as M355GP6028. Consult Manufacturer. * Wire Range Table on page 25
Data subject to change without notice.
15
Pedestal - Metered
RV Park Equipment
S P A C E
S P A GFI C E
30 20
POST
S P A GFI C E
30 20
50
5-20R2
14-50R
POST BR32U
5-20R2GFCI
S P A GFI C E
20
S P A C E
50
S P A GFI C E
20
S P A C E
14-50R
5-20R2
E M355GB6
Back-to-Back
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
S P A C E
50
S P A GFI C E
30 20
SPACE SPACE
SPACE
SPACE SPACE
SPACE
14-50R
50
S P A GFI C E
30 20
POST 5-20R2GFCI
14-50R
BR32U
5-20R2
D M075GB6 R075GB6
50A 50A 20A 30A
SPACE
POST
POST
30 20
C M075CB6010 M075CB4010 R075CB6010
20
50
50
BR32U
B M041GB6 R041GB6
50
A M041CB6010
S P A C E
POST
20
BR32U
30 20
50
30 20
GFI
S P A C E
GFI
30 20
50A 50A 20A 30A
POST 5-20R2
BR32U 14-50R
F M655GB6
14-50R
5-20R2GFCI
G M775CB6010
Earth Burial MODEL NUMBER
FIG. UL
RING TYPE
RINGLESS ——
RECEPTACLES (PER SIDE)
CIRCUIT PROTECTION (PER SIDE)
AMP
VOLTS
BR32U 5-20R2GFCI
CB130, CB120 SPACE CB120
100
120/240
S
9PT
N
LC33N1
82
1
BR32U 5-20R2
CB130, GFI120 SPACE CB120
100
120/240
S
9PT
N
LC33N1
82
1
14-50R BR32U 5-20R2GFCI
CB250, CB130 CB120 SPACE CB120
100
120/240
S
9PT
N
LC55N1
82
1
14-50R BR32U 5-20R2
CB250, CB130 GFI120 SPACE CB120
100
120/240
S
9PT
N
LC55N1
82
1
WIRE CABINET HUB LOAD & UNIT STD. RANGE* SIZE OPENING NEUTRAL BAR WT. PKG.
A
Y
M041CB6010
B
Y
M041GB6
R041GB6
C
Y
M075CB6010 %
R075CB6010
D
Y
M075GB6
R075GB6
E
Y
M355GB6
——
14-50R 5-20R2
CB250 GFI120 100 (2) SPACE CB2100
120/240
S
9PT
N
LC55N1
82
1
F
Y
M655GB6
——
14-50R 5-20R2
CB250 GFI120 (9) SPACE CB120
200
120/240
S
14PT
N
LC1212PC N1200A4
80
1
G
Y
M775CB6010
——
(2) 14-50R BR32U 5-20R2GFCI
(2) CB250T CB130 CB120T
125
120/240
S
9PT
N
——
82
1
——
14-50R BR32U 5-20R2GFCI
CB250, CB130 CB120 SPACE CB120
100
120/240
S
9PT
N
LC55N1
82
1
Padmount C
Y
M075CB4010
% Available with factory-installed TV/Telephone in post. Replace “010” with “031”.
*
Wire Range Table on page 25
16
Data subject to change without notice.
Lighted RV
RV Park Equipment
30 20
BR32U
50
5-20R2GFCI
BR54U
A U041CTLL10
Surface - Unmetered FIG. UL
S P A C E
30 20
BR32U
S P A C E
5-20R2GFCI
B U075CTLL10
LUG TYPE
MODEL NUMBER
RECEPTACLES
CIRCUIT PROTECTION
AMP
VOLTS
WIRE CABINET HUB LOAD & UNIT STD. RANGE* SIZE OPENING NEUTRAL BAR WT. PKG.
A
Y
LOOP FEED
U041CTLL10
BR32U 5-20R2GFCI
CB130 CB120
100
120/240
W
9 X 17
N
LC33N1T
14
1
B
Y
LOOP FEED
U075CTLL10
BR54U BR32U 5-20R2GFCI
CB250, CB130 CB120 SPACE
100
120/240
W
9 x 17
N
LC55N1T
16
1
30 20
S P A C E
50
MODEL NUMBER EARTH BURIAL
PADMOUNT
SPACE
14-50R
C M041CP6L10 M041CP4L10
Pedestal - Metered FIG. UL
5-20R2GFCI
RECEPTACLES
S P A C E
POST
POST BR32U
30 20
BR32U
5-20R2GFCI
D M075CP6L10 M075CP4L10
CIRCUIT WIRE CABINET HUB LOAD & UNIT STD. AMP VOLTS PROTECTION RANGE* SIZE OPENING NEUTRAL BAR WT. PKG.
C
Y
M041CP6L10
M041CP4L10 %
BR32U 5-20R2GFCI SPACE
CB130 CB120 SPACE
100
120/240
T2
9PT
Y
LC33N1
50
1
D
Y
M075CP6L10 %+ M075CP4L10 %
14-50R BR32U 5-20R2GFCI
CB250, CB130 CB120 SPACE CB120
100
120/240
T2
9PT
Y
LC55N1
59
1
+ Available with 350 MCM lug, replace “L10” with “L39” % Available with factory-installed TV/Telephone, replace “L10” with “L31”
* Wire Range Table on page 25 = Light Socket Assembly. Photocell and 7-watt incandescent lamp included in separate box - GE # 265A5262P39.
Data subject to change without notice.
17
Lighted RV
RV Park Equipment Pedestal - Unmetered
30 20
S P A C E
30 20
S P A C E
30 20
S P A C E
30 20 GFI
S P A C E
POST
S P A C E
50
30 20
S P A C E
50
30 20
S P A C E
50
30 20
S P A C E
POST 5-20R2GFCI
A U041CB6L10 U041CB4L10
R32U
5-20R2GFCI
R32U
B U041CP6L10 U041CP4L10
EARTH BURIAL
PADMOUNT
5-20R2
POST
POST BR54U
C U041GP6L U041GP4L
MODEL NUMBER FIG. UL
30 20
POST
POST R32U
50
BR32U
5-20R2GFCI
D U075CB6L10 U075CB4L10
RECEPTACLES
CIRCUIT PROTECTION
AMP
VOLTS
BR54U
BR32U
5-20R2GFCI
E U075CP6L10 U075CP4L10
BR54U
BR32U
5-20R2
F U075GP6L U075GP4L
WIRE CABINET HUB LOAD & UNIT STD. RANGE* SIZE OPENING NEUTRAL BAR WT. PKG.
A
Y
U041CB6L10
U041CB4L10
R32U 5-20R2GFCI
CB130, CB120 SPACE CB120
100
120/240
T2
6PT
N
LC33N1
42
1
B
Y
U041CP6L10
U041CP4L10
R32U 5-20R2GFCI
CB130, CB120 SPACE CB120
100
120/240
T2
6PT
N
LC33N1
30
1
C
Y
U041GP6L
U041GP4L
R32U 5-20R2
CB130 GFI120 SPACE CB120
100
120/240
T2
6PT
N
LC33N1
30
1
D
Y
U075CB6L10
U075CB4L10
BR54U BR32U 5-20R2GFCI
CB250, CB130 CB120 SPACE CB120
100
120/240
S
9PT
N
LC55N1
62
1
E
Y
U075CP6L10 %
U075CP4L10%
BR54U BR32U 5-20R2GFCI
CB250, CB130 CB120 SPACE CB120
100
120/240
T2
9PT
N
LC55N1
36
1
F
Y
U075GP6L
U075GP4L
BR54U BR32U 5-20R2
CB250, CB130 GFI120 SPACE CB120
100
120/240
T2
9PT
N
LC55N1
62
1
% Available with factory-installed TV/Telephone, replace “L10” with “L31” * Wire Range Table on page 25 = Light Socket Assembly. Photocell and 7-watt incandescent lamp included.
18
Data subject to change without notice.
TV/Tel Unmetered Units
RV Park Equipment
U004CP4031-
U075CP4031-
U075CB6031-
Unmetered
Unmetered
Unmetered
A
41-1/8”
A
65-1/8”
A
B
3-1/8”
B
4-1/2”
B
4-1/2”
C
9”
C
9”
C
9”
D
19-1/2”
D
24”
D
19”
E
16”
E
41-1/8”
E
14-1/2”
F
19-1/2”
F
5-1/4”
G
20”
U041CP6031-
see pg. 11
see pg. 13
Unmetered
Unmetered
Unmetered
A
41-1/8”
A
40-1/2”
A
B
3-3/8”
B
4-1/2”
B
3-3/8”
C
9”
C
9”
C
9”
D
19-1/2”
D
19”
D
24”
E
16”
E
7”
E
41-1/8”
F
19-1/2”
G
16”
U075CP4L31-
see pg. 11
see pg. 13
Data subject to change without notice.
U075CB4031-
see pg. 11
40-1/2”
U075CP6L31-
see pg. 18
Unmetered
Unmetered
A
65-1/8”
A
65-1/8”
B
4-1/2”
B
3-3/8”
C
9”
C
9”
D
24”
D
24”
E
41-1/8”
E
41-1/8”
F
19-1/2”
F
19-1/2”
G
15”
G
16”
H
5-1/4”
U075CP6031-
65-1/8”
see pg. 18
Flip-Cover for TV/Tel is standard with padlock provision.
see pg. 11
19
Technical Data
RV Metallic
REPLACEMENT PARTS MODEL NUMBER
M004C010 M004CP6010 M031C010 M041C010 M041CB6010 M041CP4010 M041CP4L10 M041CP4L31 M041CP6010 M041CP6L10 M041G M041GB6 M041GP4 M041GP6 M055C010 M055G M055GP6 M075C010 M075CB4010 M075CB6010 M075CB6031 M075CP4010 M075CP4L10 M075CP4L31 M075CP6010 M075CP6031 M075CP6L10 M075CP6L31 M075CP6L39 M075G M075GB6 M075GP4 M075GP6 M076C010 M355C010 M355CP6010 M355G M355GB6 M355GP4 M355GP6 M355GP6028 M358CP6 M655GB6 M655GP6 M775CB6010 M775CP6010 R031C010 R041C010 R041CP6010 R041G R041GB6 R041GP6
CABINET DIMENSIONS **
METER * SOCKET
POST LUGS
CABINET SIZE pages 23-24
MSM100930 MSM100P9 MSM100930 MSM100930 A MSM100P9 MSM100P9 MSM100P9 MSM100P9 MSM100P9 MSM100930 A MSM100P9 MSM100P9 MSM100930 MSM100930 MSM100P9 MSM100930 A A A MSM100P9 MSM100P9 MSM100P9 MSM100P9 MSM100P9 MSM100P9 MSM100P9 MSM100P9 MSM100930 A MSM100P9 MSM100P9 MSM100930 MSM100930 MSM100P9 MSM100930 A MSM100P9 MSM100P9 MSM100P9 MSM100P9 MW200M MW200M A MSM100P9 MSR100930 MSR100930 MSR100P9 MSR100930 B MSR100P9
—— LT100S300 —— —— LT100B350 LT100S300 LT100S250 LT100S300 LT100S300 LT100S250 —— LT100B350 LT100S250 LT100S300 —— —— LT100S250 —— LT100B350 LT100B350 LT100B350 LT100S300 LT100S300 LT100S300 LT100S300 LT100S300 LT100S300 LT100S300 LT100S350 —— LT100B350 LT100S250 LT100S250 —— —— LT100S300 —— LT100B350 LT100S300 LT100S300 LT100S250 LT100B350 LT200B350 LT200S350 LT100B350 LT100S250 —— —— LT100S300 —— LT100B350 LT100S250
9 X 30 9PT 9 X 30 9 X 30 9PT 9PT 9PT 9PT 9PT 9PT 9 X 30 9PT 9PT 9PT 9 X 30 9 X 30 9PT 9 X 30 9PT 9PT 9PT 9PT 9PT 9PT 9PT 9PT 9PT 9PT 9PT 9 X 30 9PT 9PT 9PT 9 X 30 9 X 30 9PT 9 X 30 9PT 9PT 9PT 9PT 9PT 14PT 14PT 9PT 9PT 9 X 30 9 X 30 9PT 9 X 30 9PT 9PT
ENCLOSURE STYLE page 23
HEIGHT
A
B
C
KNOCKOUT FIGURE page 23
B B B B B B B B B B B B B B -
30" 30" 30" 30" 30" 30" 30" 30" 30" 30" 30" 30" 30” 30" -
9-3/4" 9-3/4" 9-3/4" 9-3/4" 9-3/4" 9-3/4" 9-3/4" 9-3/4" 9-3/4" 9-3/4" 9-3/4" 9-3/4" 9-3/4” 9-3/4" -
5-3/16" 5-3/16" 5-3/16" 5-3/16" 5-3/16" 5-3/16" 5-3/16" 5-3/16" 5-3/16" 5-3/16" 5-3/16" 5-3/16" 5-3/16” 5-3/16" -
2 2 2 2 2 2 2 2 2 2 2 2 2 2 -
WIDTH
DEPTH
A Front (Inline Side) MSM100P9, Back (Powerhead side) MSM100HP B Front (Inline Side) MSR100P9, Back (Powerhead side) MSR100HP
** For Post Cabinet Sizes and Dimensions see page 24.
20
Data subject to change without notice.
Technical Data
RV Metallic
REPLACEMENT PARTS MODEL NUMBER
R055C010 R055G R075C010 R075CB6010 R075CP4010 R075CP6010 R075CP6031 R075GB6 R075GP6 R076C010 R355CP6010 R355CP6031 R355G R355GP6 U004CB4010 U004CB6010 U004CP4010 U004CP4031 U004CP6010 U010C010 U010G U011C010 U011CP4010 U011CP6010 U011CTL010 U011G U011GB4 U011GB6 U011GP4 U011GP6 U011GTL U031C010 U040G U040GP4 U040GP6 U040GP6010 U040GTL U041C010 U041CB4010 U041CB4L10 U041CB6010 U041CB6L10 U041CP4010 U041CP4031 U041CP4039 U041CP4L10 U041CP6010 U041CP6031 U041CP6039 U041CP6L10 U041CTL010 U041CTLL10 U041G U041GB4 U041GB6 U041GP4
CABINET DIMENSIONS **
METER SOCKET
POST LUGS
CABINET SIZE pages 23-24
MSR100930 MSR100930 MSR100930 MSR100P9 MSR100P9 MSR100P9 MSR100P9 B MSR100P9 MSR100930 MSR100P9 MSR100P9 MSR100930 MSR100P9 —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— ——
—— —— —— LT100B350 LT100S250 LT100S300 LT100S300 LT100B350 —— —— —— —— —— —— LT100B350 LT100B350 LT100S250 LT100S300 LT100S300 —— —— —— LT100S300 LT100S300 —— –— LT100B250 LT100B250 LT100S250 LT100S300 —— —— —— LT100S250 LT100S300 LT100S250 —— —— LT100B250 LT100B250 —— LT100B250 LT100S250 LT100S250 LT100S350 LT100S250 LT100S300 LT100S250 LT100S350 LT100S300 —— —— —— LT100B250 LT100B250 LT100S300
9 X 30 9 X 30 9 X 30 9PT 9PT 9PT 9PT 9PT 9PT 9 X 30 9PT 9PT 9 X 30 9PT 9PT 9PT 9PT 9PT 9PT 6X9 6X9 6 X 14 6PT 6PT 9 X 17 6 X 14 6PT 6PT 6PT 6PT 9 X 17 9 X 17 6 X 14 6PT 6PT 6PT 9 X 17 6 X 14 6PT 6PT 6PT 6PT 6PT 6PT 6PT 6PT 6PT 6PT 6PT 6PT 9 X 17 9 X 17 6 X 14 6PT 6PT 6PT
ENCLOSURE STYLE page 23
HEIGHT
A
B
C
KNOCKOUT FIGURE page 23
B B B -
30" 30" 30" -
9-3/4" 9-3/4" 9-3/4" -
5-3/16" 5-3/16" 5-3/16" -
2 2 2 -
B B A A A A A A A A A A A A A -
30" 30" 9-1/8" 9-1/8" 14-3/8" 17-3/8" 14-3/8" 17-3/8" 17-3/8" 14-3/8" 17-3/8" 14-3/8" 17-3/8" 17-3/8" 14-3/8" -
9-3/4" 9-3/4" 7-1/4" 7-1/4" 7-1/4" 9-3/4" 7-1/4" 9-3/4" 9-3/4" 7-1/4" 9-3/4" 7-1/4" 9-3/4" 9-3/4" 7-1/4" -
5-3/16" 5-3/16" 5-3/16" 5-3/16" 5-3/16" 5-3/16" 5-3/16" 5-3/16" 5-3/16" 5-3/16" 5-3/16" 5-3/16" 5-3/16" 5-3/16" 5-3/16" -
2 2 1 1 1 2 1 2 2 1 2 1 2 2 1 -
WIDTH
DEPTH
B - Front (Inline Side) MSR100P9, Back (Powerhead side) MSR100HP
** For Post Cabinet Sizes and Dimensions see page 24. Data subject to change without notice.
21
Technical Data
RV Metallic
REPLACEMENT PARTS MODEL NUMBER
U041GP4L U041GP6 U041GP6L U041GTL U042GB6 U042GP6 U043GP6 U055C010 U055CP4010 U055CP6010 U055G U055GB6 U074GTL U075CB4010 U075CB4031 U075CB4L10 U075CB6010 U075CB6031 U075CB6L10 U075CP4010 U075CP4031 U075CP4L10 U075CP4L31 U075CP6010 U075CP6010D U075CP6031 U075CP6039 U075CP6039D U075CP6L10 U075CP6L31 U075CTL010 U075CTLL10 U075GB6 U075GP4 U075GP4L U075GP6 U075GP6019 U075GP6L U075GTL U076C010 U131CP6010 U131CTL010 U175CP6HP010 U355C010 U355G U355GP6 U412CP6010 U412G U412GP6 U611CB4010 U611CB6010 U611CP4010 U611CP6010 U611CTL010 U611GTL U775C010 U775CP4010 U775CP6010
CABINET DIMENSIONS **
METER SOCKET
POST LUGS
CABINET SIZE pages 23-24
—— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— —— ——
LT100S250 LT100S300 LT100S250 —— LT100B250 LT100S300 LT100S250 —— LT100S300 LT100S300 —— LT100B250 —— LT100B350 LT100B350 LT100B350 LT100B350 LT100B350 LT100B350 LT100S300 LT100S300 LT100S300 LT100S250 LT100S300 LT100S250 LT100S300 LT100S350 —— LT100S300 LT100S300 —— —— LT100B350 LT100S300 LT100S250 LT100S300 LT100S250 LT100S300 —— —— LT100S250 —— —— —— —— LT100S250 LT100S300 —— LT100S300 LT100B250 LT100B250 LT100S250 LT100S300 —— —— —— LT100S300 LT100S250
6PT 6PT 6PT 9 X 17 6PT 6PT 6PT 6 X 14 6PT 6PT 6 X 14 6PT 9 X 17 9PT 9PT 9PT 9PT 9PT 9PT 9PT 9PT 9PT 9PT 9PT 9PT 9PT 9PT 9PT 9PT 9PT 9 X 17 9 X 17 9PT 9PT 9PT 9PT 9PT 9PT 9 X 17 9 X 17 14PT 14 X 21 14PT 9 X 17 9 X 17 9PT 9PT 9 X 17 9PT 9PT 9PT 9PT 9PT 9 X 17 9 X 17 9 X 17 9PT 9PT
ENCLOSURE STYLE page 23
HEIGHT
WIDTH
DEPTH
A
B
C
KNOCKOUT FIGURE page 23
A A A A A A A A A A A A A A A -
17-3/8" 14-3/8" 14-3/8" 17-3/8" 17-3/8" 17-3/8" 17-3/8" 17-3/8" 21-3/8" 17-3/8" 17-3/8" 17-3/8" 17-3/8" 17-3/8" 17-3/8" -
9-3/4" 7-1/4" 7-1/4" 9-3/4" 9-3/4" 9-3/4" 9-3/4" 9-3/4" 14-3/4" 9-3/4" 9-3/4" 9-3/4" 9-3/4" 9-3/4" 9-3/4" -
5-3/16" 5-3/16" 5-3/16" 5-3/16" 5-3/16" 5-3/16" 5-3/16" 5-3/16" 6-7/16" 5-3/16" 5-3/16" 5-3/16" 5-3/16" 5-3/16" 5-3/16" -
2 1 1 2 2 2 2 2 3 2 2 2 2 2 2 -
** For Post Cabinet Sizes and Dimensions see page 24. 22
Data subject to change without notice.
Cabinet Dimensions & Knockouts RV Power Outlets - Cabinet Dimensions CABINET SIZE
ENCLOSURE STYLE
A
B
C
6x9 6x14 9x17 9x30 14x21
Fig. A Fig. A Fig. A Fig. B Fig. A
9-1/8” 14-3/8” 17-3/8” 30” 21-3/8”
7-1/4” 7-1/4” 9-3/4” 9-3/4” 14-3/4”
5-3/16” 5-3/16” 5-3/16” 5-3/16” 6-7/16”
KO DETAIL Fig. Fig. Fig. Fig. Fig.
1 1 2 2 3
Enclosure Style (FIG. B)
(FIG. A)
Knockout Configurations (FIG. 2)
(FIG. 1)
G
G G
N
G G
G
G
(FIG. 3)
D
G G
B B
G
C
C
C
C
A E
C
C Q
A= 1-1/2", 2", 2-1/2"
D= 3/4", 1", 1-1/4"
N= 1/2", 3/4", 1", 1-1/4", 1-1/2"
B= 1", 1-1/4", 1-1/2"
E= 3/4"
Q= 1"
C= 1-1/4", 1-1/2", 2"
G= 1/2", 3/4", 1"
W= 1/2", 3/4", 1", 1-1/4", 2"
Data subject to change without notice.
23
Post Dimensions 6PT EARTH BURIAL
6PT PAD MOUNT UNMETERED A
UNMETERED
62"
C 19-3/4"
A
D 6-1/2"
C 17-3/4"
E 3-1/4"
D 6-1/2"
F
18"
E
G
6"
Single Head Post
Single Head Post
36"
3-3/4"
Double Head Post (Back to Back)
Double Head Post (Back to Back)
9PT PAD MOUNT
9PT EARTH BURIAL UNMETERED
METERED
UNMETERED METERED
A
65"
77-1/2"
A 41-1/8" 53-1/2"
B
----
45-1/4"
B
19-1/8"
C 19-3/4" 19-1/2"
C 19-1/8" D
9"
9"
E 3-1/2"*
D 9"
3-1/2"*
F
18"
18"
G
6"
6"
---
45-1/2" 9"
E 3-1/2"* 3-1/2"* * Some models available in 4-3/8". Contact Distributor/Factory.
* Some models available in 4-3/8". Contact Distributor/Factory.
Single Head Post Single Head Post
Double Head Post (Back to Back)
Double Head Post (Back to Back)
14PT EARTH BURIAL
KEY UNMETERED
METERED
A 83-1/2"
86"
B
50"
----
C 49-1/2" D
9"
E 3-1/2"*
49-1/2" 9"
A= B= C= D= E= F= G=
Post Length Meter Center to Grade Terminal Bar to Grade Post Width Post Depth Grade to Wire Opening Wire Opening
3-1/2"*
F
18"
18"
G
6"
6"
* Some models available in 4-3/8". Contact Distributor/Factory.
Single Head Post
24
Double Head Post (Back to Back)
Data subject to change without notice.
Wire Range Tables TABLE B
TABLE P Copper
Connector
Copper
Aluminum Connector
Solid
Strand
Solid
Strand
Line
14-8
14-6
12-8
12-6
Line
Load
14-10
14-10
----
----
Load
Neutral
12-8
12-6
12-8
12-6
Neutral
Equip. Grnd.
12-8
12-2
12-8
12-2
Neutral
End Hole Side Hole
Equip. Grnd.
TABLE U
Line Load Neutral Neutral
Large Hole Small Hole
Equip. Grnd.
Load Neutral Neutral
Large Hole Small Hole
Equip. Grnd.
Solid
Strand
14-8
14-1/0
12-8
12-1/0
14-10
14-10
----
----
14-8
14-2
12-8
12-2
14-8
14-4
12-8
12-4
12-8
12-2
12-8
12-2
Copper Connector
Solid
Strand
Solid
Strand
14-8
14-1/0
12-8
12-1/0
Line
14-10
14-10
----
----
Load
(Loop Feed)
Large Hole Small Hole
12-8
12-1/0
10-8
10-1/0
Neutral
14-8
14-4
12-8
12-4
Neutral
12-8
12-2
12-8
12-2
Equip. Grnd.
Aluminum
Solid
Strand
Solid
Strand
14-8
14-1/0
12-8
12-1/0
14-10
14-10
----
----
12-8
12-1/0
10-8
10-1/0
14-8
14-4
12-8
12-4
12-8
12-2
12-8
12-2
TABLE AR Copper
Line
Strand
Aluminum
TABLE AA Connector
Solid
TABLE W Copper
Connector
Aluminum
Copper
Aluminum
Solid
Strand
Solid
Strand
----
6-1/0
----
6-1/0
14-10
14-10
----
----
12-8
12-1/0
10-8
10-1/0
14-8
14-4
12-8
12-4
12-8
12-2
12-8
12-2
Connector
Aluminum
Solid
Strand
Solid
Strand
Line
14-1/0
14-1/0
----
----
Load
14-10
14-10
----
----
Neutral
----
----
----
----
Equip. Grnd.
12-8
12-2
----
----
TABLE S
TABLE T2
Post Line Connectors Suitable for Loop Feed #6-350 KCMIL CU #6-350 KCMIL AL
Post Line Connectors Suitable for Loop Feed #1-300 KCMIL CU #1-300 KCMIL AL
Equip. Grnd.
Data subject to change without notice.
#12-2 CU/AL
Equip. Grnd.
#12-2 CU/AL
25
RV Non-Metallic
ParkMate/ParkRanger
ParkMateTM
12.75”
10”
20.75”
H3 Receptacle (GFI duplex)
8“ Dockmate shown with optional Metallic Post
41.5”
Loop feed Terminal Lugs
Double Head Post (Back to Back)
ParkRangerTM
16.1
13.1
14.7
13.6
41.7
7.0
26
ParkMateTM
RV Power Center
ParkMate™ RV Power Centers represent the latest in technology and design, combining appearance and functionality. Now, campground owners can select an attractive power center that combines all the features RVers request.
VKKJHCQT
ParkMate™ is excellent for surface mount and post applications, offering a wide array of accessories including: light, photoelectric sensor, telephone, cable T.V. connections and electric metering. All this in one attractive package - now that makes sense!
Front Dimensions D 8” W 10” H 13-1/2”
H
ParkMate™ is injection molded from VALOX® engineered thermoplastic resin. VALOX® resin is a lightweight, impact and corrosion resistant material, designed to provide long, maintenance free service. ParkMate™ RV Power Centers are rugged, convenient and attractive. Manufactured in the quality tradition of Midwest Electric Products, Inc.
D
Back Dimensions D 8” W 9-3/16” H 12-1/8”
W
Interior view of the head
Features and Benefits
FLUORESCENT LIGHT Long lasting, low consumption 7 watt light provides security and easy night time plug in.
ELECTRONIC DIGITAL METER
MOLDED OF ® TOUGH VALOX THERMOPLASTIC
UP TO THREE RECEPTACLES AVAILABLE
CABLE TV JACK TELEPHONE JACK PHOTOCELL (Not Shown) SINGLE OR BACK TO BACK MODELS
G-90, HEAVILY GALVANIZED STEEL POST
WATER SHROUD ACCESSORY (faucet not included)
20 AMP AVAILABLE with GFI breaker or GFI receptacles.
LOOP FEED LUGS 350 KCMIL STANDARD FACTORY WIRED FOR EASY INSTALLATION
DIRECT BURIAL OR PAD MOUNT INSTALLATION
Data subject to change without notice.
• 4-circuit load center installed (LC44X1) • Service Entrance rated and Listed by Underwriters Laboratories • VALOX® thermoplastic enclosure and internal components are corrosion resistant • Factory wired power receptacles are available in 20 amp, 30 amp, or 50 amp configurations protected by thermal magnetic circuit breakers. Ground Fault breakers are also available • Hinged cover closes over plugs and cords, maintaining a safe, weather tight enclosure • Easy to wire terminal lugs accept up to 1/0 Cu/Al cable • Post features 350 KCMIL loop-feed lugs • Optional 7 watt fluorescent light illuminates receptacle for easy night time plug-in, while providing security lighting and easy identification of power center location. Light circuit is protected by a 20 Amp circuit breaker. Light cover molded of LEXAN® polycarbonate • Photoelectric sensor automatically turns light on and off • Telephone and cable TV jack accessory kits mount easily in power center, giving your installation a neat and uncluttered appearance. Telephone jacks are PH6596 corrosion resistant outlets. Cable TV jacks are suitable for type RG-59 coax cable. • Electrical rating of 100 amp max., 120/240 volt, 1Ø-3 wire with ground • Hinged cover has a positive latch with padlocking provisions • Post dimensions are 62"H (38" above grade) x 9"W x 3-1/4"D or 4-3/8" D • Optional loop feed lug kit (ULOOP) available for Parkmate™ not on a post • ParkMate™, post, and water shroud are tan in color • Standard 200A/350KCMIL lugs installed in Pedestal models. • Amp Rating – 200 Amp on back-to-back; 100 Amp on single. • Galvanized post is type G90-16 gauge • Stainless post is type 304L-16 gauge NOTE: Metered units for use in California require special testing and certification. Contact Manufacturer for information.
27
ParkMateTM
Technical Information
Example: Model Number VPKJHCQT VP
KJH
CQ
Model Type
Side 1 Receptacle
Side 1 Options
Model Type
T Side 2 Receptacle
Side 2 Options
Paint Options
(where applicable)
(where applicable)
(standard tan)
Receptacles
Option Codes
Color
Most Common Models - Single Sided**
ParkMate Model
Receptacle Configuration
No Options
7 watt light
7 watt light & photocell
“CQ” 7 watt light, photocell & 1 TV/Tel
Choose Specific Model
20A/20A 30A/20A 50A/20A 30A/30A/20A 50A/30A/20A
ZHHAAT JZHAAT KZHAAT JJHAAT KJHAAT
ZHHAQT JZHAQT KZHAQT JJHAQT KJHAQT
ZHHAUT JZHAUT KZHAUT JJHAUT KJHAUT
ZHHCQT JZHCQT KZHCQT JJHCQT KJHCQT
*model # prefix not shown
“AA”
“AQ”
“AU”
“AC” Metered Only
“CS” Metered, 7 watt light, photocell, 1 TV/Tel
ZHHACT JZHACT KZHACT JJHACT KJHACT
ZHHCST JZHCST KZHCST JJHCST KJHCST
** Models can be single or double-sided. See Model Configurator on page 29.
Wiring Diagrams
S P A C E S P A C E
S P A C E
30 20
7 watt light
S P A C E
30 20
S P A C E S P A C E
S P A C E
30 20
7 watt light
S P A C E
30 20
7 watt light
digital meter
R32U
R32U
R32U
(1)-TV/phone photo-cell
photo-cell
JZHAAT
30 20
7 watt light
30 20
7 watt light
50 GFI
7 watt light
50 GFI
50 GFI
JZHCST
JZHAUT
30 20
JZHCQT 30 20
5-20R2GFI
5-20R2GFI
5-20R2GFI
R32U
(1)-TV/phone photo-cell
50 GFI
5-20R2GFI
digital meter
G Y W
5-20R2GFI
R32U
14-50R
R32U
14-50R
photo-cell
KJHAAT
28
KJHAUT
Y
X W
5-20R2GFI
G
G
G Y
X
5-20R2GFI R32U
Y
X W
14-50R
X W
5-20R2GFI
R32U
14-50R
photo-cell
(1)-TV/phone photo-cell
KJHCQT
KJHCST
(1)-TV/phone
ParkMate/ParkRanger STEP 1: Choose Unit Type (2 characters) ParkMate Single:
Back-to-Back:
VP
VS
Examples:
STEP 2: Choose desired receptacles for Head 1 or 2 (3 characters) Single:
Back-to-Back:
KJH
KJH
Examples:
STEP 3: Choose desired options for Head 1 or 2 (2 characters) Single:
Back-to-Back:
CQ
AW
Examples:
Repeat Steps 2 & 3 for any back-to-back models to arrive at model number. Receptacles and options can vary on back side.
Code VK VM VN VO VP VQ VR VS VT VW VW
Unit Type-Base Only ParkMate Power Center (Head Only) ParkMate, single-side, w/stainless steel padmount post ParkMate, single-side, w/stainless steel earth burial post ParkMate, single-side, w/galvanized steel padmount post ParkMate, single-side, w/galvanized steel earth burial post ParkMate, back-to-back, w/stainless steel padmount post ParkMate, back-to-back, w/stainless steel earth burial post ParkMate, back-to-back, w/galvanized steel padmount post ParkMate, back-to-back, w/galvanized steel earth burial post ParkRanger, single-side, w/thermoplastic padmount post ParkRanger, back-to-back, w/thermoplastic padmount post
Code K G J N H I
Most Common Receptacle/Circuit Breaker Combinations (Straight Blade Receptacles) 14-50R 50 amp 125/250 V 14-50R 50 amp 125/250 V with GFI Breaker R32U 30 amp 125 V R32U 30 amp 125 V with GFI Breaker 5-20R2 20 amp 125 V with GFCI Duplex 5-20R2 20 amp 125 V Duplex with GFI Breaker
Code AA AQ AU AW CQ AC AS CM CS CO BW BY DS EK EO
Options No Options 7 watt light only 7 watt light and Photocell 7 watt light, Photocell, and Metered 1 TV/Tel, 7 watt light, and Photocell Metered 7 watt light and Metered 1 TV/Tel and 7 watt light 1 TV/Tel, 7 watt light, Photocell, and Metered 1 TV/Tel, 7 watt light, and Metered 1 TV/Tel 1 TV/Tel and Metered 2 TV/Tel 2 TV/Tel and Metered 2 TV/Tel, 7 watt light, Photocell, and Metered
Accessories (Field Installed)
STEP 4: Color
* May be factory installed using appropriate option code
ParkMate -- Standard Tan (add T suffix) ParkRanger -- Standard White (add W suffix) Contact factory for special paint requests. Example Models:
Model Configuration
Single: VPKJHCQT Back-to-Back: VSKJHAWKJHAWT
Data subject to change without notice.
Model VLIGHT VLOOP VAPE VKTELTV1 VKTELTV2 ULUG3 UH11AL UH12AL UH90ST UH90GT UHH UBFP UWATER34
Description 7 Watt Fluorescent Light 1/0 Loop Lug Kit (For head only -- Loop lug installed in post) Photoelectric sensor TV/Tel Connection Kit (1 TV/Tel Jack)** TV/Tel Connection Kit (2 TV/Tel Jacks)** 4th Position Lug For 3-Phase Loop Feed #6-350 KCMIL Water Shroud (1) - Handicapped Accessible (ParkRanger) Water Shroud (2) - Handicapped Accessible (ParkRanger) Stainless Steel Water Shroud (ParkMate) Galvanized Water Shroud (ParkMate) One Pair Cord and Hose Storage Rack Backflow Preventer 3/4” Hose Bib ** Standard RJ-11 Phone Jack
* Replacement Posts Available for ParkMate Models. Contact Factory for more information. Reference ‘VB’ or ‘VP’ prefixes.
29
ParkRangerTM
Non-Metallic RV Power Pedestal
The Next Generation of Outdoor Luxury ParkRanger is a new, non-metallic padmount power pedestal that combines all the favorite features of the old pedestals with the advanced technology and advantages of a non-metallic pedestal. ALL THE AMENITIES OF HOME • Power, running water, cable TV, and telephone access • Multiple options available to fulfill individual needs • Emphasis on convenience and safety • Connections grouped behind weather resistant cover for easy access and security • Lighting options provide clear view of service panel for nighttime connection AESTHETICS AND DESIGN FLEXIBILITY • Flip-top receptacles and other external components have been eliminated • Clean, crisp lines • Controlled lighting system for accent lighting • Custom finishes • Single or double-sided • Individual site metering to recover electrical costs INSTALLATION, UPGRADING AND MAINTENANCE ADVANTAGES • Factory assembled and wired to minimize on-site installation time and expense • Advance shipping of base sections available to facilitate rough wiring and plumbing • Easy to change or add service options with upgrade kits • Long-term durability • Molded from GE engineered VALOX plastics • Reduces corrosion problems • Infrequent maintenance FEATURES • Unitized service panel to accept electrical components, telephone, cable TV, and lighting options • 100 to 200 amps for use with 120/240 volt, single phase, 3 wire plus ground • Ambient compensated thermal magnetic circuit breaker • Weather resistant with VALOX thermoplastic enclosure • Corrosion resistant internal components • Prismatic lens with lighting options to effectively eliminate glare and create maximum illumination • Dress panel on reverse side of all single service pedestals • Oversize access panel for easy installation, upgrading and quick meter reading • Base module with loop feed terminal bar • 4-Circuit load center installed • 350 MCM loop feed 30
Data subject to change without notice.
ParkRangerTM
Technical Information
Example: Model Number VWKJHCQW VW
KJH
CQ
Model Type
Side 1 Receptacle
Side 1 Options
Model Type
W Side 2 Receptacle
Side 2 Options
Paint Options
(where applicable)
(where applicable)
(standard white)
Receptacles
Option Codes
Color
Most Common Models - Single Sided** “AA”
“AU”
“CQ”
Receptacle Configuration
No Options
7 watt light & photocell
7 watt light, photocell, & 1 TV/Tel
“CS” Metered w/ 7 watt light, photocell, & 1 TV/Tel
30A/20A 50A/30A/20A
VWJZHAAW VWKJHAAW
VWJZHAUW VWKJHAUW
VWJZHCQW VWKJHCQW
VWJZHCSW VWKJHCSW
** Models can be single or double-sided. See Model Configurator on page 29.
30 20
S P A C E
S P A C E
7 watt light
S P A C E
7 watt light
S P A C E
S P A C E
S P A C E
30 20
S P A C E S P A C E
30 20
7 watt light
30 20
Wiring Diagrams
digital meter
R32U
R32U
7 watt light
30 20
50 GFI
7 watt light
30 20
VWJZHAUW
VWJZHCSW
7 watt light
50 GFI
photo-cell
VWJZHAAW
(1)-TV/phone photo-cell
30 20
R32U
50 GFI
30 20
VWJZHCQW
5-20R2
5-20R2
5-20R2
R32U
(1)-TV/phone photo-cell
50 GFI
5-20R2
digital meter
5-20R2
5-20R2
5-20R2 R32U
14-50R
R32U
14-50R
photo-cell
VWKJHAAW
Data subject to change without notice.
VWKJHAUW
5-20R2 R32U
14-50R
(1)-TV/phone photo-cell
VWKJHCQW
R32U
14-50R
(1)-TV/phone photo-cell
VWKJHCSW
31
Parts & Accessories TEMPORARY ADAPTERS
(Not UL listed)
AD 20 30
AD 30 20
AD 50 20
ADAPTS
ADAPTS
ADAPTS
TO
TO
TO
15 AMP., 125 VOLT 30 AMP., 125 VOLT 10 PK. ONLY
30 AMP., 125 VOLT 15 AMP., 125 VOLT 10 PK. ONLY
RECEPTACLES AND ANGLE PLUGS
50 AMP., 125/250 VOLT 15 AMP., 125 V. 10 PK. ONLY
Receptacles
Angle Plugs
Receptacles on Plates
BR54U
C54U
PR54U
Angle Plugs Offers increased flexibility by plugging into receptacles at an angle where space limitations exist. Plugs are molded of Zytel® Nylon, a rugged impact resistant material. NEMA CONFIGURATIONS
AMP.
VOLTAGE
MODEL NUMBER
MODEL NUMBER
MODEL NUMBER
5-20 R
20
125
5-20R2 DUPLEX
—
—
30
125
BR32U1 R32U2
C32U
PR32U
30 30 50 50 60 60
125/250 125/250 125/250 125/250 120/208 125/250
BR331 BR341 BR531 BR54U1 --BR64U1
C33 C34 C53 C54U C54 C64U
PR33 PR34 PR53 PR54U --PR64U
ANSI C73 13-1972 R-32-U 30 AMP. 125 VOLT (Travel Trailer Use Only) 10-30R 14-30R 10-50R 14-50R 18-60R 14-60R
(See Below)
1Receptacle 2Bracket
is complete with bracket to base mount into unit. not included. Mounts directly on dead front.
Post Only
(With cover)
FEATURES • Post only with 3 wire openings (back and both sides) • Earth burial and pad mounted • Terminal bar assembly with loop feed lugs standard • Surface mount units may be field installed on these posts (Not UL listed) • Swing-down hasp (latch) for padlock provision • Painted 16 gauge galvanized steel
32
MODEL NUMBER
DESCRIPTION
W
P5 POST P6 POST
Pad Mount Earth Burial
9 9
DIMENSIONS H D 59-1/2 83-1/2
4-1/2 4-1/2
520R2
FACTORY INSTALLED TERMINAL ASSEMBLY
STD. PKG
LT200B350 LT200B350
1 1
520R2GFI (No Leads)
Data subject to change without notice.
Parts & Accessories Post Extensions
Sealing Ring
EK126 6PT (6") Post Models EK129* 9PT (9") Post Models
ASR1 Screw Style Sealing Ring for Ring-Type Meter Sockets
Kit consists of: (1) Post Extension Bracket, (2) 1/2" Bolts, (2) 1/2" Nuts, (4) 1/2" Flatwashers. Dimensions: 18"L x 6"W or 9"W
SNPR1 Snap-On Style Sealing Ring for RingType Meter Sockets
*Add “CW” for WEPCO Approved Model
Bolt-On Hub
Post Stake
(Standard Pkg Qty in 10 pcs.) Closure plate is standard with most Midwest products. Order appropriate hub from chart below.
MS62 Kit consists of: (1) Post Stake Bracket, (2) 1/2" Bolts, (2) 1/2" Nuts, (4) 1/2" Flatwashers. Dimensions: 44"L x 3"W or 1"D
MODEL NUMBER HUB SIZE
Tie Bars 121
131
(threaded)
MIDWEST HUB
UNIVERSAL HUB
3/4"
B07
––––
1"
B10
U10
1-1/4"
B12
U12
1-1/2"
B15
U15
2"
B20
U20
2-1/2"
B25
U25
3"
U30
4"
–––– –––– ––––
CLOSURE PLATE – SM
B01
U01
CLOSURE PLATE – LG
––––
U04
3-1/2"
Stabilizer Base & Stabilizer Foot Kit FBEM9 Earth Burial Installation - wire from back only
U40
*For replacement hub screws, order B01, U01, or U04 as appropriate.
SFEM9
SFEM6 6" Stabilizer Foot Kit
FBEM9
U35
SFEM9 9" Stabilizer Foot Kit
Circuit Breaker Filler Plates MODEL 265A5003P1 265A5003P2 265A5003P11
DESCRIPTION 1" Metal 2" Metal 1" Plastic
265A5003P12
2" Plastic
- wire from side or back
Touch-Up Paint TV/Telephone Add-On TTV100 – TV/Telephone Add-on accessory bolts on at ground level to the back of a padmount post, earth-burial post, or a wall. The open back and open bottom make for easy wiring. Factory or field-installed TV/Telephone receptacle may be field replaced with data (Cat5) or other similar feature receptacle. Includes in-use cover. - Unit is non-NEMA and non-UL - RJ11 Phone Jack; height 12 inches - will mount on pad or direct burial post Data subject to change without notice.
Textured Paint PRODUCT NUMBER
PCAMOTEX PTANTEX PBLUETEX PWHITETEX PBRONZETEX Glossy Paint PBLUE PGRAY61 PTAN PWHITE
DESCRIPTION
Camo Green Tan Blue White Bronze Blue Gray Tan White
33
Parts & Accessories Water Shroud & Hose Bib Water Shroud Models: UH20GG - Adapts to 6” wide galvanized steel post - grey color UH90G - Adapts to 9” wide galvanized steel post - grey color UH90GT - Adapts to 9”wide galvanized steel post - tan color UH90ST - Adapts to 9” wide stainless steel post - tan color UH11AL - Water shroud (1) - Handicap Accessible (ParkRanger) UH12AL - Water shroud (2) - Handicap Accessible (ParkRanger) Hose Bib: UWATER34 - 3/4” Hose Bib Faucet for Post Applications
Water Shroud
Water Shroud and Hose Bib Connected on ParkMate
Camper Clips
50-Amp Receptacle Lockout Panel
CLP1 - Kit contains: 6 clips and 6 screws
PLK50 - Replacement deadfront kit with 50-Amp Receptacle lockout feature for all U075- or M075series units, with Sample Deadfront GFCI duplex cut-out.
- Tempered steel (galvanized, zinc-coated) spring tensioned clips used to attach site cards to post. - Dimensions: 1” W x 2.13” H
Included in PLK50 Kit: Replacement Deadfront & Plate Cover for 50 Amp Receptacle
50 Amp
RV Substation Midwest Electric’s RV substations provide a safe, economical way to deliver power to Power Centers and Power Pedestals. The substations consist of a core and coil dry-type transformer and a distribution panelboard in a common enclosure. • NEMA 3R, Marine grade enclosures • 15kva-300kva transformer range • Contact Midwest rep for additional information
34
Parts & Accessories Load Center Interiors Part Number LC33N1 LC33N1T LC33N7 LC44X1 LC55N1T LC55N1 LC1212PC
Circuits 3 3 3 4 5 5 12
Volts 120/240 120/240 120/240 120/240 120/240 120/240 120/240
Amps 100 100 70 100 100 100 200
Line Lug Size #14-1/0 CU AL (2)#14-1/0 CU AL/Phase #14-1/0 CU AL #14-1/0 CU AL (2)#14-1/0 CU AL/Phase #14-1/0 CU AL #6-250 KCMIL
LC33N7
LC33N1T
LC33N1
LC55N1
Neutral Lug Size (2)#14-1/0, (2)#14-4 CU AL (2)#14-1/0, (2)#14-4 CU AL (4)#14-2 CU AL None (2)#14-1/0, (2)#14-4 CU AL (2)#14-1/0, (2)#14-4 CU AL None
LC44X1
LC1212PC
LC55N1T
Meter Bases 100 Amp sockets for models manufactured after February 1995 Replacement Model No.
Type
Rating
Lug Style
Line Lug Wire Range
Optional Neutral Kit
MSM1009301
Ring-Type
100
Lay-in
#6-350KCMIL
MSBN4
9" x 30" Surface Panels
MSR100930
Ringless
100
Lay-in
#6-350KCMIL
MSBN4
9" x 30" Surface Panels
MSM100P91
Ring-Type
100
Lay-in
#6-350KCMIL
MSBN4
9PT Single Sided Posts
MSR100P9
Ringless
100
Lay-in
#6-350KCMIL
MSBN4
9PT Single Sided Posts
MSBN4
All Other Panels and Post Units
Description
200 Amp socket for models manufactured after 1984 MW200M1 1
Ring-Type
200
Box Style
1/0-350KCMIL
Midwest Electric manufactured meter socket only.
MSM100930
35
MSR100P9
MW200M
Manufacturer’s Sales Representatives Offices A
*
A
British Columbia
A
A
A 75 Lachine, Quebec
Auburn
30
*
*
66
Billings
30
Minneapolis
37
6
*
* *
*
Milwaukee
*
Salt Lake City
23
36
Kansas City
59
83
55
35
Los Angeles
*
*
50
Cincinnati
* *
*
*
39
Atlanta
KEY:
* 58 Houston
*
29
62
*
41
Irving
30
12
Farmingdale
Greensboro
7
*
25
*
*
Glen Allen
*
56
53
Tempe
*
77
Millersville
*57 Memphis
85 Bensalem
*
Woburn
45
Louisville
St. Louis
Little Rock
Oklahoma City
*
46
11
*
Indianapolis
La Vergne Tulsa
Pittsburgh
* *
Hudson
61
Council Bluffs
*
Denver
Syracuse
Detroit
Elk Grove Village
9 Sausalito
*
22
Mankato
*
A
36
Portland
*
Representative Office Headquarters Factory and Headquarters Representative Territories
Metairie
72
State/Province Borders
Deerfield Beach
*
1
Midwest Electric Products, Inc. Mankato, MN 56002 Phone: (507) 345-2505 FAX: (507) 345-2530 www.midwestelectric.com
25
Electra Sales of North Texas, Inc. Irving, TX 75061 Phone: (972) 554-8200 FAX: (972) 554-7861 www.electrasales.net
A
Hydel Vaughan, ON L4K5W1 Phone: (800) 263-4579 FAX: (905) 669-4518 www.circaent.com/hydel
29
E-Tel Houston, TX 77028 Phone: (713) 678-4460 FAX: (713) 678-4371 www.etelinc.com
6
Lesco, Inc. Milwaukee, WI 53225 Phone: (414) 393-1428 FAX: (414) 438-0741 www.lesco-inc.com
30
Robert A. Amey Company Portland, OR 97229 Phone: (503) 646-7196 FAX: (503) 626-8569 www.ameyco.com
50
Schaeffer Sales, Inc. St. Louis, MO 63043 Phone: (314) 291-9500 FAX: (314) 291-9595 www.schaeffersales.com
7
Bishop & Brogdon Atlanta, GA 30336 Phone: (404) 494-4333 (800) 241-2963 FAX: (404) 344-3696
35
53
9
Bixler Marketing Group Council Bluffs, IA 51501 Phone: (712) 328-1841 (888) 924-9537 FAX: (712) 328-7449 www.bixlermarketing.com
SEGI Tempe, AZ 85282 Phone: (480) 317-0868 (866) 969-7344 FAX: (480) 317-0875 www.segisalespros.com
36
SEGI Billings, MT 59101 Phone: (406) 248-9224 FAX: (406) 245-6953
55
37
Electro-Lines, Inc. Syracuse, NY 13208 Phone: (315) 455-5701 (800) 962-5760 FAX: (315) 455-7114 www.electrolines.com
11
12
Arthur Boyle Company, Inc. Indianapolis, IN 46220 Phone: (317) 577-9100 (800) 776-9101 FAX: (317) 577-9161 Gumersell Cashdan, Inc. Farmingdale, NY 11735 Phone: (631) 752-9440 FAX: (631) 752-9415 www.gumcash.com
22
G.N. Deperro Company Detroit, MI 48211 Phone: (313) 875-4010-11-12 (800) 875-9120 FAX: (313) 872-5544
23
Electrorep Sausalito, CA 94965 Phone: (415) 332-4100 FAX: (415) 332-4150 www.electrorep.com
39
Farmer Electrical Sales, Inc. Greensboro, NC 27415 Phone: (336) 375-1122 (800) 849-0244 FAX: (336) 375-0177 www.farmerelectrical.com
41
L.W. French, Inc. Glen Allen, VA 23060 Phone: (804) 270-3205 FAX: (804) 270-0885 www.lwfrench.com
45
Gemco Sales, Inc. Pittsburgh, PA 15201 Phone: (412) 562-9300 FAX: (412) 562-9028
46
J.R. Bovyer Electrical Sale of OH Hudson, OH 44236 Phone: (330) 656-4128 (800) 362-6613 FAX: (330) 650-2586 www.bovyereso.com
59
MWE, Inc. Kansas City, MO 64108 Phone: (816) 842-9283 FAX: (888) 842-8047 www.mweinc.com
61
Schmitz Electrical Sales Elk Grove Village, IL 60007 Phone: (847) 364-3605 FAX: (847) 364-4107
62
O.T. Hall & Son, Inc. Millersville, MD 21108 Phone: (410) 987-5990 (888) 621-7435 FAX: (410) 987-9691 www.othall.com
Curtis H. Stout, Inc. Little Rock, AR 72202 Phone: (501) 372-2555 FAX: (501) 375-4453 www.curtishstoutinc.com
66
Lesco, Inc. Minneapolis, MN 55427 Phone: (763) 542-8242 FAX: (763) 542-9309 www.lesco-inc.com
Electrical Products of Oklahoma Oklahoma City, OK 73116 Phone: (405) 842-8371 FAX: (405) 843-1636
72
Tulsa, OK 74112 Phone: (918) 663-1923 Fax: (918) 663-0015
Metra Associates, Inc. Deerfield Beach, FL 33442 Phone: (954) 428-4444 (800) 201-3465 FAX: (954) 428-4455 www.metra-assoc.com
75
John Moore & Associates, Inc. La Vergne, TN 37086 Phone: (615) 287-0500 FAX: (615) 287-0662 www.jmaone.com
Theovine, Inc. Lachine, Quebec, Canada Phone: (514) 637-0050 FAX: (514) 637-4630 www.theovine.com
77
David Role & Co. Woburn, MA 01801 Phone: (781) 932-8810 (800) 878-0852 FAX: (781) 932-8815
Cincinnati, OH 45227 Phone: (513) 561-0500 800-582-0500 Fax: (513) 561-1811
56
Memphis, TN 38114 Phone: (901) 948-0193 FAX: (901) 948-0194 57
Summit Sales & Marketing, Inc. Louisville, KY 40203 Phone: (888) 279-2780 FAX: (502) 636-2575 www.summitsales-mkt.com
83
J.R. Schmidt & Associates Englewood, CO 80115 Phone: (866) 592-1313 FAX: (303) 778-7613 www.jr-schmidt.com
58
Syn-Tech, Inc. Metairie, LA 70002 Phone: (504) 835-7825 (800) 535-7619 FAX: (504) 835-7853 www.syntech-inc.com
85
Pollart Electrical Sales Co., Inc. Bensalem, PA 19020 Phone: (800) 372-8000 FAX: (215) 245-0773 www.pollart-electrical.com
36