elephant quickbrace systems

Report 0 Downloads 41 Views
Elephant Plasterboard QuickBrace Systems

September 2013

ELEPHANT QUICKBRACE SYSTEMS SUPPLEMENTARY UPDATE: SEPTEMBER 2013

Revised and Improved Performances Enhanced QuickBrace Software Consolidated Bracing Systems Smart Numbering System Independently Appraised NZS 3604:2011 Compliant

www.elephantplasterboard.co.nz

0800 ELEPHANT (353742)

Elephant Plasterboard Quickbrace Elephant Plasterboard (NZ) Limited have conducted extensive bracing tests. The Bracing ratings published in this document have been obtained by independent testing and opinions sourced by organizations with accredited quality assurance. Detailed in this document are some unique design solutions now available to the New Zealand Building Industry to satisfy the bracing requirements of the New Zealand Standard NZS 3604:2011 Timber framed buildings.

Recent Changes We have made changes and improvements to the Elephant Plasterboard Quickbrace Systems.

• Revised Performances Recent testing on the ENSS and the EHMSc systems using the new BRANZ P21 (2010) Test Methodology have shown improved performances. All published performances have either been re-evaluated or tested to the new BRANZ P21 (2010) Test Methodology. These provide responsible, conservative and reliable bracing ratings.

• Enhanced Elephant QuickBrace© Software There have been a number of significant changes and enhancements to the QuickBrace Software. These enhanced features will assist designers and engineers to not only comply to the rules of NZS 3604:2011 but also assist in good design and construction. The new software can be downloaded from our website www.elephantplasterboard.co.nz or by emailing [email protected] to request a copy.

Elephant Plasterboard Bracing Design Solutions System Lining Requirement Code

Additional Bottom Plate Fixing

ENS

Elephant Standard-Plus on one side

ENSS

Elephant Standard-Plus on both sides

EHSc

Elephant Standard-Plus on one side

EHSSc

Elephant Standard-Plus on both sides

EHSPc

Elephant Standard-Plus on one side, Plywood on the other

External

EHMc

Elephant Multiboard on one side

External or Internal

EHMSc

Elephant Multiboard on one side, Standard-Plus on the other

EHMPc

Elephant Multiboard on one side, Plywood on the other

External or Internal

None

Internal External or Internal

Panel End Hold Downs

Panel End Hold Downs

Internal

Internal External

Compliance to NZS 3604:2011 The Elephant Quickbrace Systems detailed in this document and the Elephant Quickbrace Software are fully compliant to the requirements of NZS 3604:2011 Timber-framed buildings.

Elephant Quickbrace© Numbering System E = Elephant Plasterboard Systems

H = Panel Hold Downs Required N = No Panel Hold Downs

For further information call our Free Help line 0800 ELEPHANT (353 742)

S SS SP M MS MP

=

=

Standard-Plus on one side Standard-Plus on both sides Standard-Plus on one side, Plywood the other Multiboard on one side Multiboard on one side, Standard-Plus the other Multiboard on one side, Plywood the other

c

=

Requires the Condensed Corner Pattern

= = = =

Elephant Plasterboard Bracing Systems

Elephant Plasterboard

September 2013

Elephant Quickbrace© Corner Pattern Types

50

50

150

50

150

50

50

50 50 50 50 50 50

Typical Bracing Corner Pattern Fix 12mm min from paper bound edges and18mm min from sheet ends or cut edges

50

50

50

150

Condensed Bracing Corner Pattern

150

150

150

50 50 50

50

Fix 12mm min from paper bound edges and18mm min from sheet ends or cut edges

Elephant Quickbrace© Systems System Number

ENS

ENSS

EHSc

EHSSc

EHSPc

EHMc

EHMSc

EHMPc

Lining Requirement

Elephant Standard-Plus on one side

Elephant Standard-Plus on both sides

Elephant Standard-Plus on one side

Elephant Standard-Plus on both sides

Elephant Standard-Plus on one side Plywood on the other

Elephant Multiboard on one side

Elephant Multiboard on one side Elephant Standard-Plus on the other

Elephant Multiboard on one side Plywood on the other

Min. Length (m)

BU/m Wind

Earthquake

0.4

65

65

0.8

70

65

1.8

85

70

0.4

75

65

0.8

85

75

1.2

95

85

0.4

85

80

0.8

105

90

1.8

120

90

0.4

100

115

0.8

145

135

1.2

150

145

0.4

105

120

0.6

130

140

0.8

150

150

0.4

90

105

0.8

130

120

1.2

150

125

0.4

110

115

0.8

150

140

1.2

150

150

0.4

115

125

0.6

135

140

0.8

150

150

Panel Holddowns

Corner Pattern

No

Typical

Yes

Condensed

Yes

Condensed

* Timber Floors - It is required by NZS 3604:2011 to limit BU ratings to 120 BU/m for timber floors. For a higher floor frame uplift, a specifically engineered design will be required. Note- The Elephant QuickBrace© Numbering System and the sub components thereof are protected by copyright.

For further information go to www.elephantplasterboard.co.nz

Elephant Plasterboard Bracing Systems

Elephant Plasterboard QuickBrace Systems

Elephant Plasterboard (NZ) Limited For more information visit www.elephantplasterboard.co.nz or email [email protected] or call 0800 ELEPHANT (353742)

September 2013