Emergency Stop Relays, Safety Gate Monitors

Report 3 Downloads 43 Views
Emergency Stop Relays, Safety Gate Monitors Category 4, EN 954-1 PNOZ X9 Technical Details Electrical Data Supply Voltage

Emergency stop relay and safety gate monitor in accordance with VDE 0113-1, 11/98, EN 60204-1, 12/97 and IEC 204-1, 11/98

Features ● Dual-channel operation, with or without detecting shorts across the input contacts ● Automatic or monitored manual reset can be selected ● Designed for operation via semiconductor outputs ● 2 semiconductor outputs (Fault, K1/K2) ● Each AC unit can be operated with 24 VDC

Approvals PNOZ X9 ● ● ●

PNOZ X9

AC: 24, 42, 100, 120, 200, 230 V DC: 24 V 85 ... 110 % Approx. 5.5 W/11 VA 24 VDC, 50 mA

Tolerance Power Consumption Voltage and Current at the Input and Reset Circuits and Feedback Control Loop Switching Capability in accordance with EN 60947-4-1, 10/91 AC1: 240 V/8 A/2000 VA 400 V/8 A/2000 VA DC1: 24 V/8 A/200 W EN 60947-5-1, 10/91 AC15: 230 V/5 A; DC13: 24 V/7A (DC13: 6 cycles/min.) Output Contacts 7 safety contacts (N/O), 2 auxiliary contacts (N/C) Contact Fuse Protection 10 A quick or 6 A slow (EN 60947-5-1, 10/91) Times Delay-on Energisation Max. 250 ms Delay-on De-energisation Max. 25 ms Recovery Time Approx. 0.3 s Simultaneity channel 1/2 Max. 150 ms Max. Supply Interruption before De-energisation Approx. 35 ms Mechanical Data Maximum Cross Section of 2 x 1.5 mm 2 or 1 x 2.5 mm2 External Conductors Single-core or multi-core with crimp connectors Dimensions (H x W x D) 87 x 90 x 121 mm Weight 950 g

Description

Operating Modes

● 90 mm, P-93 housing, DIN-Rail mounting ● Positive-guided relay outputs: – 7 safety contacts (N/O) – 2 auxiliary contacts (N/C) ● Connections for – E-STOP button – safety gate limit switch – reset button ● LEDs for power, channel 1 IN, channel 2 IN, start (reset), channel 1 and channel 2 ● Increase in the number of safety contacts available by connecting expander modules.

● ● ● ● ●

Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: [email protected]

1

Single-channel operation Dual-channel operation Automatic reset Manual reset Monitored manual reset

NSG-D-2-037-07/03

1-1

Emergency Stop Relays, Safety Gate Monitors Category 4, EN 954-1 PNOZ X9 Internal Wiring Diagram

– Key

Auxiliary Input circuits Reset circuit Safety contacts contacts S12 S11 S52 S21 S22 S33 S34 Y1 Y2 S37 Y1 13 23 33 43 53 63 73 81 91

B1 (+) S11

1

S1/2:

E-STOP or safety gate switch

S3:

Reset button Switch operated

A1

AC

A2 Y31

K1

Gate open

K2

Gate closed

DC 24 V DC ext.

K3

Y35 & Y32 Y30

K2

K1

0 V ext.

K3

B2 (0 V)

14 24 34 44 54 64 74 82 92

External Wiring

● Increase in safety contacts The number of output contacts can be increased by using expander modules or relays/contactors with positive-guided contacts. 1L1

● Example 1 Single-channel E-STOP wiring with manual reset.

● Example 4 Dual-channel E-STOP wiring with monitored manual reset. S21 S11 S11

S11 S12 S21 S33 Y1

S1

S1

S12

Y1

K4

K5

Y1

Y2

13

Y1

S3

14

S3 K4

K5

1L2

S22 S12 S52

S12 S52 S22 S34 Y2

● Example 2 Dual-channel E-STOP wiring with manual reset. S21 S11 S11

S12

Y1

S34 S37

Y2

● Example 5 Dual-channel safety gate control with manual reset. S11

S21

S12

Y1

S34

Y2

S1

S1 S3

S22 S11

S3

S2

S22 S12 S52

S34

Y2

● Example 3 Single-channel E-STOP wiring with monitored manual reset. S11 S12 S21 S33 Y1

Y1

S12

S52

● Example 6 Dual-channel safety gate control with automatic reset. S11

S33

S21

Y1

S22

Y2

S1

S1

S52 S11

S3

S12 S52 S22 S34 S37 Y2

S2

S12

S34

Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: [email protected]

NSG-D-2-037-07/03

Emergency Stop Relays, Safety Gate Monitors Category 4, EN 954-1 PNOZ X9 General Technical Data Unless stated otherwise in the technical details for the specific unit Electrical Data Frequency Range AC Residual Ripple DC Contact Material Continuous Duty Environmental Data EMC Vibration in accordance with EN 60068-2-6, 04/95 Climatic Suitability Airgap Creepage Ambient Temperature Storage Temperature Mechanical Data Torque Setting on Connection Terminals Mounting Position Housing Material Protection

1

50 ... 60 Hz 160 % AgSnO2 100 % EN 50081-1, 01/92, EN 50082-2, 03/95 Frequency: 10 ... 55 Hz, Amplitude: 0.35 mm DIN IEC 60068-2-3, 12/86 DIN VDE 0110 part 1, 04/97 -10 ... +55 °C -40 ... +85 °C 0.6 Nm (screws) Any Thermoplast Noryl SE 100 Mounting: IP 54 Housing: IP 40 Terminal Range: IP 20

The units were tested in accordance with the relevant standards current at the time of development. Order References Type PNOZ PNOZ PNOZ PNOZ PNOZ PNOZ

X9 X9 X9 X9 X9 X9

UB 24 V AC/DC 42 V AC/ 24 V DC 100 V AC/24 V DC 120 V AC/24 V DC 200 V AC/ 24 V DC 230 V AC/ 24 V DC

Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: [email protected]

Order No. 774 609 774 601 774 602 774 605 774 608 774 606

NSG-D-2-037-07/03

1-3