SECTION 8
ENCAPSULATED DISTRIBUTION TRANSFORMERS Commercial & Industrial Single Phase and Three Phase HPS Fortress™ Commercial Encapsulated Transformers Applications & Features ..................................................................................... Single Phase Standard Specification ............................................................. Single Phase Selection Tables .......................................................................... Three Phase Standard Specifications ............................................................. Three Phase Selection Tables ...........................................................................
190 192 193 196 197
HPS TITAN® Industrial Encapsulated Transformers Applications ............................................................................................................. Features & Benefits .............................................................................................. Single Phase Standard Specifications ............................................................ Single Phase Selection Tables .......................................................................... Three Phase Standard Specifications ............................................................. Three Phase Selection Tables ...........................................................................
199 199 200 201 203 204
Enclosure Dimensional Drawings .................................................................... Accessories - Enclosure Mounting Kits, Anti-Vibration Pads & Isolators .............................. Wiring Schematic Drawings ..............................................................................
228 238 243
SECTION 8
HPS FORTRESS™
HPS Fortress Features HPS Fortress is an innovative design that provides the ideal solution for commercial applications where quality, ease of installation, and low cost are key. All units are encapsulated with electrical grade silica sand and resin compounds, which completely enclose the core and coil to seal out moisture, airborne contaminants and eliminates corrosion and deterioration.
Standard Features
SECTION 8
Features
Single Phase
Three Phase
Voltage Groups
9 standard voltage groups
8 standard voltage groups
Ratings
From 50VA to 37.5kVA
From 2kVA to 75kVA
Shield
Standard shield from 750VA and up
Standard shield on all units
Frequency
60 Hz (50Hz standard on four voltage groups)
60Hz standard on all voltage groups Standard via copper leads
Connection Type 3R
Enclosure Quality Design
Conduit Knockouts Installation
Warranty
Type 3R (type 4/12 with optional gasket kit installed)
All units are encapsulated with electrical grade silica sand and resin compounds, which completely enclose the core and coil to seal out moisture, airborne contaminants and eliminates corrosion and deterioration. For rear and side entry into an easily accessible and roomy wiring compartment (no knock-outs on Stainless Steel enclosures). Wall mounting up to 25kVA, optional wall mounting bracket available on 37.5kVA. Wall mounting template supplied.
Wall mounting up to 9kVA, optional wall mounting bracket available on 15kVA, 30kVA and 45kVA. Wall mounting template supplied.
All HPS standard catalog encapsulated transformers come with a 10 year limited* warranty *(Please refer to the HPS Warranty on page 26 for full details.)
Inexpensive & a s y © Hammond Power Solutions Inc.
190
Applications •
Shopping Centers
•
Schools
•
Sports Complexes
•
Office Buildings
•
Lighting
For accessories see pages 238 to 241 Data subject to change without notice.
SECTION 8
COMMERCIAL ENCAPSULATED
HPS Fortress Features continued...
Totally enclosed to seal out moisture and airborne contaminants.
Type 4/12 enclosure rating available when optional gasket kit is installed.
Type 3R enclosure meets or exceeds listing criteria including NEMA, and ANSI standards for indoor and outdoor applications.
Installation made quick and easy with keyhole mounting slots and supplied wall mounting template.
Easily accessible nameplate. All three phase units come standard with two nameplates. One on the front and one on the inside top cover.
All units are encapsulated with electrical grade silica sand and resin compounds.
Note: Picture displayed above is a standard three phase HPS Fortress units.
© Hammond Power Solutions Inc.
191
For accessories see pages 238 to 241 Data subject to change without notice.
SECTION 8
Rear and side entry conduit knockouts into an easily accessible and roomy wiring compartment.
SECTION 8
HPS FORTRESS™
HPS FORTRESS™
COMMERCIAL ENCAPSULATED DISTRIBUTION TRANSFORMERS SINGLE PHASE STANDARD SPECIFICATIONS 1.5 TO 37.5 KVA
.05 kVA to 1 kVA
1.5 kVA to 37.5 kVA
SECTION 8
0.50 TO 1 KVA
UL Listed
File: E50394
File: E50394
CSA Certified
File: LR3902
File: LR3902
Frequency
60 Hz (50/60 Hz)
60 Hz (50/60 Hz)
Insulation System
130°C (80°C rise) standard on all units
180°C (115°C rise) standard on all units.
Electrostatic Shield
Standard on 0.75 kVA and up.
Standard on all units.
Encapsulation
All units are encapsulated with electrical grade silica sand and resin compounds.
All units are encapsulated with electrical grade silica sand and resin compounds.
Enclosure Type
Type 3R
Type 3R
Enclosure Finish
ANSI 61 Grey, UL50
ANSI 61 Grey, UL50
Termination
Front accessible separate high and low voltage lead wires or copper tabs.
Front accessible separate high and low voltage lead wires or copper tabs.
Conduit Knock-Outs
Standard side and rear knock-outs on all units (no knock-outs on Stainless Steel enclosures).
Standard side and rear knock-outs on all units (no knock-outs on Stainless Steel enclosures).
Impedance
Typically 5 to 10%.
Typically 1 to 5%.
Mounting
Standard Wall Mounting.
Standard Wall Mounting up to 25kVA. Optional wall mounting kit for 37.5kVA units. Lifting provisions standard on units 5 kVA and up.
Sound Level
Meets NEMA ST-20 standards.
Meets NEMA ST-20 standards
Other voltages and kVA ratings not listed in this section are available upon request. Please contact customer service for details, price and availability.
© Hammond Power Solutions Inc.
192
For accessories see pages 238 to 241 Data subject to change without notice.
SECTION 8
COMMERCIAL ENCAPSULATED
SINGLE PHASE, NEMA 3R STYLE ENCLOSURE 120 X 240 Primary Volts
0.05 0.10 0.15 0.25 0.35 0.50 0.75 1 1.5 2 3 5 7.5 10
C1FC05EE C1FC10EE C1FC15EE C1FC25EE C1FC35EE C1FC50EE C1FC75EES C1F1C0EES C1F1C5EES C1F002EES C1F003EES C1F005EES C1F007EES C1F010EES
Case Style
(Pages 228 - 230)
Width
Depth
Height
Approx. Weight (Lbs.)
NQ0 NQ0 NQ0 NQ0 NQ1 NQ1 NQ2 NQ3 NQ3 NQ4 NQ4 NQ5 NQ6A NQ6
3.69 3.69 3.69 3.69 4.31 4.31 5.06 5.88 5.88 7.06 7.06 10.00 12.25 12.25
5.06 5.06 5.06 5.06 5.56 5.56 4.56 5.19 5.19 6.25 6.25 7.75 9.25 9.25
7.19 7.19 7.19 7.19 7.19 7.19 9.30 10.56 10.56 11.75 11.75 17.25 17.63 20.88
7 7 8 9 15 16 23 24 33 42 55 96 148 178
208 X 416 Primary Volts kVA
Catalog Number
0.05 0.10 0.15 0.25 0.35 0.50 0.75 1 1.5 2 3 5 7.5 10
C1FC05GE C1FC10GE C1FC15GE C1FC25GE C1FC35GE C1FC50GE C1FC75GES C1F1C0GES C1F1C5GES C1F002GES C1F003GES C1F005GES C1F007GES C1F010GES
Case Style
Catalog Number
0.05 0.10 0.15 0.25 0.35 0.50 0.75 1 1.5 2 3 5 7.5 10
C1FC05WE C1FC10WE C1FC15WE C1FC25WE C1FC35WE C1FC50WE C1FC75WES C1F1C0WES C1F1C5WES C1F002WES C1F003WES C1F005WES C1F007WES C1F010WES
Approx. Dimensions (Inches)
(Pages 228 - 230)
Width
Depth
Height
NQ0 NQ0 NQ0 NQ0 NQ1 NQ1 NQ2 NQ3 NQ3 NQ4 NQ4 NQ5 NQ6A NQ6
3.69 3.69 3.69 3.69 4.31 4.31 5.06 5.88 5.88 7.06 7.06 10.00 12.25 12.25
5.06 5.06 5.06 5.06 5.56 5.56 4.56 5.19 5.19 6.25 6.25 7.75 9.25 9.25
7.19 7.19 7.19 7.19 7.19 7.19 9.30 10.56 10.56 11.75 11.75 17.25 17.63 20.88
7 7 8 9 15 16 23 24 33 42 55 96 148 178
Case Style
Mtg Type W - Wall F - Floor
(Pages 243 - 258)
W W W W W W W W W W W W W W
SCD1 SCD1 SCD1 SCD1 SCD1 SCD1 SCD1 SCD1 SCD1 SCD1 SCD1 SCD1 SCD2 SCD2
120/240 Secondary Volts Approx. Weight (Lbs.)
120/208/240/277 Primary Volts kVA
Approx. Dimensions (Inches)
(Pages 228 - 230)
Width
Depth
Height
Approx. Weight (Lbs.)
NQ0 NQ0 NQ0 NQ1 NQ2 NQ2 NQ2 NQ3 NQ3 NQ4 NQ5 NQ5 NQ6 NQ6
3.69 3.69 3.69 4.31 5.06 5.06 5.06 5.88 5.88 7.06 10.00 10.00 12.25 12.25
5.06 5.06 5.06 5.56 4.56 4.56 4.56 5.19 5.19 6.25 7.75 7.75 9.25 9.25
7.19 7.19 7.19 7.19 9.30 9.30 9.30 10.56 10.56 11.75 17.25 17.25 20.88 20.88
7 7 8 10 17 25 23 24 37 52 65 108 171 183
© Hammond Power Solutions Inc.
193
Wiring Diagram
60 Hz
Mtg Type W - Wall F - Floor
(Pages 243 - 258)
W W W W W W W W W W W W W W
SCD1 SCD1 SCD1 SCD1 SCD1 SCD1 SCD1 SCD1 SCD1 SCD1 SCD1 SCD1 SCD2 SCD2
120/240 Secondary Volts Approx. Dimensions (Inches)
60 Hz
Wiring Diagram
60 Hz
Mtg Type W - Wall F - Floor
Wiring Diagram
(Pages 243 - 258)
W W W W W W W W W W W W W W
SCD41 SCD41 SCD41 SCD41 SCD41 SCD41 SCD41 SCD41 SCD41 SCD41 SCD2 SCD2 SCD2 SCD2
For accessories see pages 238 to 241 Data subject to change without notice.
SECTION 8
kVA
Catalog Number
120/240 Secondary Volts
SECTION 8
HPS FORTRESS™
SINGLE PHASE, NEMA 3R STYLE ENCLOSURE
SECTION 8
240 X 480 Primary Volts kVA
Catalog Number
0.05 0.10 0.15 0.25 0.35 0.50 0.75 1 1.5 2 3 5 7.5 10 15 25 37.5
C1FC05LE C1FC10LE C1FC15LE C1FC25LE C1FC35LE C1FC50LE C1FC75LES C1F1C0LES C1F1C5LES C1F002LES C1F003LES C1F005LES C1F007LES C1F010LES C1F015LES C1F025LES C1F037LES
120/240 Secondary Volts Approx. Dimensions (Inches)
(Pages 228 - 230)
Width
Depth
Height
Approx. Weight (Lbs.)
NQ0 NQ0 NQ0 NQ1 NQ1 NQ1 NQ2 NQ3 NQ3 NQ4 NQ4 NQ5 NQ6A NQ6 NQ7 NQ8 NQS10
3.69 3.69 3.69 4.31 4.31 4.31 5.06 5.88 5.88 7.06 7.06 10.00 12.25 12.25 14.50 14.50 21.88
5.06 5.06 5.06 5.56 5.56 5.56 4.56 5.19 5.19 6.25 6.25 7.75 9.25 9.25 10.75 10.75 18.50
7.19 7.19 7.19 7.19 7.19 7.19 9.30 10.56 10.56 11.75 11.75 17.25 17.63 20.88 21.38 27.38 31.00
7 7 8 9 15 16 23 24 33 42 55 115 148 179 265 385 598
Case Style
60 Hz
Mtg Type W - Wall F - Floor
Wiring Diagram
(Pages 243 - 258)
W W W W W W W W W W W W W W W W F or W*
SCD1 SCD1 SCD1 SCD1 SCD1 SCD1 SCD1 SCD1 SCD1 SCD1 SCD1 SCD1 SCD2 SCD2 SCD2 SCD2 SCD2
*Optional wall mounting kit required. Refer to page 240 for details.
277 Primary Volts kVA
Catalog Number
0.05 0.10 0.15 0.25 0.35 0.50 0.75 1 1.5 2 3 5 7.5 10
C1FC05CE C1FC10CE C1FC15CE C1FC25CE C1FC35CE C1FC50CE C1FC75CES C1F1C0CES C1F1C5CES C1F002CES C1F003CES C1F005CES C1F007CES C1F010CES
277/480 Primary Volts kVA
Catalog Number
0.05 0.10 0.15 0.25 0.35 0.50 0.75 1 1.5 2 3 5 7.5 10
C1FC05HR C1FC10HR C1FC15HR C1FC25HR C1FC35HR C1FC50HR C1FC75HRS C1F1C0HRS C1F1C5HRS C1F002HRS C1F003HRS C1F005HRS C1F007HRS C1F010HRS
120/240 Secondary Volts Approx. Dimensions (Inches)
(Pages 228 - 230)
Width
Depth
Height
Approx. Weight (Lbs.)
NQ0 NQ0 NQ0 NQ0 NQ2 NQ2 NQ2 NQ3 NQ3 NQ4 NQ4 NQ5 NQ6A NQ6
3.69 3.69 3.69 3.69 5.06 5.06 5.06 5.88 5.88 7.06 7.06 10.00 12.25 12.25
5.06 5.06 5.06 5.06 4.56 4.56 4.56 5.19 5.19 6.25 6.25 7.75 9.25 9.25
7.19 7.19 7.19 7.19 9.30 9.30 9.30 10.56 10.56 11.75 11.75 17.25 17.63 20.88
7 7 8 9 15 15 23 24 33 42 55 115 148 178
Case Style
208/277 Secondary Volts Approx. Dimensions (Inches)
(Pages 228 - 230)
Width
Depth
Height
NQ0 NQ0 NQ0 NQ1 NQ2 NQ2 NQ3 NQ3 NQ4 NQ4 NQ5 NQ5 NQ6 NQ6
3.69 3.69 3.69 4.31 5.06 5.06 5.88 5.88 7.06 7.06 10.00 10.00 12.25 12.25
5.06 5.06 5.06 5.56 4.56 4.56 5.19 5.19 6.25 6.25 7.75 7.75 9.25 9.25
7.19 7.19 7.19 7.19 9.30 9.30 10.56 10.56 11.75 11.75 17.25 17.25 20.88 20.88
7 8 11 12 15 18 25 31 39 54 80 156 188 179
© Hammond Power Solutions Inc.
194
Mtg Type W - Wall F - Floor
Wiring Diagram
(Pages 243 - 258)
W W W W W W W W W W W W W W
SCD4 SCD4 SCD4 SCD4 SCD4 SCD4 SCD4 SCD4 SCD4 SCD4 SCD4 SCD4 SCD2 SCD2
50/60 Hz
Approx. Weight (Lbs.)
Case Style
50/60 Hz
Mtg Type W - Wall F - Floor
Wiring Diagram
(Pages 243 - 258)
W W W W W W W W W W W W W W
SCD42 SCD42 SCD42 SCD42 SCD42 SCD42 SCD42 SCD42 SCD42 SCD42 SCD43 SCD43 SCD43 SCD43
For accessories see pages 238 to 241 Data subject to change without notice.
SECTION 8
COMMERCIAL ENCAPSULATED
SINGLE PHASE, NEMA 3R STYLE ENCLOSURE 347/380 Primary Volts Catalog Number
0.05 0.10 0.15 0.25 0.35 0.50 0.75 1 1.5 2 3 5 7.5 10
C1FC05JE C1FC10JE C1FC15JE C1FC25JE C1FC35JE C1FC50JE C1FC75JES C1F1C0JES C1F1C5JES C1F002JES C1F003JES C1F005JES C1F007JES C1F010JES
(Pages 228 - 230)
Width
Depth
Height
Approx. Weight (Lbs.)
NQ0 NQ0 NQ0 NQ0 NQ1 NQ1 NQ2 NQ3 NQ3 NQ4 NQ5 NQ5 NQ6A NQ6
3.69 3.69 3.69 3.69 4.31 4.31 5.06 5.88 5.88 7.06 10.00 10.00 12.25 12.25
5.06 5.06 5.06 5.06 5.56 5.56 4.56 5.19 5.19 6.25 7.75 7.75 9.25 9.25
7.19 7.19 7.19 7.19 7.19 7.19 9.30 10.56 10.56 11.75 17.25 17.25 17.63 20.88
7 7 8 9 14 14 23 32 35 51 98 120 162 194
Case Style
600 Primary Volts kVA
Catalog Number
0.05 0.10 0.15 0.25 0.35 0.50 0.75 1 1.5 2 3 5 7.5 10 15 25 37.5
C1FC05PE C1FC10PE C1FC15PE C1FC25PE C1FC35PE C1FC50PE C1FC75PES C1F1C0PES C1F1C5PES C1F002PES C1F003PES C1F005PES C1F007PES C1F010PES C1F015PES C1F025PES C1F037PES
Approx. Dimensions (Inches)
50/60 Hz (Pages 243 - 258)
W W W W W W W W W W W W W W
SCD33 SCD33 SCD33 SCD33 SCD33 SCD33 SCD33 SCD33 SCD33 SCD33 SCD44 SCD44 SCD44 SCD44
120/240 Secondary Volts Approx. Dimensions (Inches)
(Pages 228 - 230)
Width
Depth
Height
Approx. Weight (Lbs.)
NQ0 NQ0 NQ0 NQ0 NQ1 NQ1 NQ2 NQ3 NQ3 NQ4 NQ4 NQ5 NQ6A NQ6 NQ7 NQ8 NQS10
3.69 3.69 3.69 3.69 4.31 4.31 5.06 5.88 5.88 7.06 7.06 10.00 12.25 12.25 14.50 14.50 21.88
5.06 5.06 5.06 5.06 5.56 5.56 4.56 5.19 5.19 6.25 6.25 7.75 9.25 9.25 10.75 10.75 18.50
7.19 7.19 7.19 7.19 7.19 7.19 9.30 10.56 10.56 11.75 11.75 17.25 17.63 20.88 21.38 27.38 31.00
7 7 8 9 15 16 23 24 33 42 55 120 148 179 265 385 598
Case Style
Mtg Type W - Wall F - Floor
Wiring Diagram
60 Hz
Mtg Type W - Wall F - Floor
Wiring Diagram
(Pages 243 - 258)
W W W W W W W W W W W W W W W W F or W*
SCD4 SCD4 SCD4 SCD4 SCD4 SCD4 SCD4 SCD4 SCD4 SCD4 SCD4 SCD4 SCD5 SCD5 SCD5 SCD5 SCD5
*Optional wall mounting kit required. Refer to page 240 for details.
Export Model
190/200/208/220/2401 X 380/400/416/440/4801 Primary Volts 120/240 Secondary Volts 50/60 Hz kVA
Catalog Number
Case Style
(Pages 228 - 230)
Approx. Dimensions (Inches) Width
Depth
0.05 C1FC05XE NQ0 3.69 5.06 0.10 C1FC10XE NQ0 3.69 5.06 0.15 C1FC15XE NQ0 3.69 5.06 0.25 C1FC25XE NQ0 3.69 5.06 0.35 C1FC35XE NQ1 4.31 5.56 0.50 C1FC50XE NQ1 4.31 5.56 0.75 C1FC75XES NQ2 5.06 4.56 1 C1F1C0XES NQ3 5.88 5.19 1.5 C1F1C5XES NQ4 7.06 6.25 2 C1F002XES NQ4 7.06 6.25 3 C1F003XES NQ5 10.00 7.75 5 C1F005XES NQ5 10.00 7.75 7.5 C1F007XES NQ6A 12.25 9.25 10 C1F010XES NQ6 12.25 9.25 Note 1: The primary voltage ratio of 240 or 480 is available at 60Hz only with a secondary voltage of approximately 130/262V.
© Hammond Power Solutions Inc.
195
Height
Approx. Weight (Lbs.)
Mtg Type W - Wall F - Floor
Wiring Diagram
(Pages 243 - 258)
7.19 7.19 7.19 7.19 7.19 7.19 9.30 10.56 11.75 11.75 17.25 17.25 17.63 20.88
7 7 9 10 15 16 24 32 37 52 97 120 148 179
W W W W W W W W W W W W W W
SCD28 SCD28 SCD28 SCD28 SCD28 SCD28 SCD28 SCD28 SCD28 SCD28 SCD2 SCD2 SCD2 SCD2
For accessories see pages 238 to 241 Data subject to change without notice.
SECTION 8
kVA
120/240 Secondary Volts
SECTION 8
HPS FORTRESS™
HPS FORTRESS™
COMMERCIAL ENCAPSULATED DISTRIBUTION TRANSFORMERS THREE PHASE STANDARD SPECIFICATIONS 6 TO 75 KVA
SECTION 8
2 TO 3 KVA
2 kVA to 3 kVA
6 kVA to 75 kVA
UL Listed
File: E50394
File: E50394
CSA Certified
File: LR3902
File: LR3902
Frequency
60 Hz (50/60 Hz)
60 Hz (50/60 Hz)
Insulation System
130°C (80°C rise) standard on all units.
180°C (115°C rise) standard on all units.
Electrostatic Shield
Standard on all units.
Standard on all units.
Encapsulation
All units are encapsulated with electrical grade silica sand and resin compounds.
All units are encapsulated with electrical grade silica sand and resin compounds.
Enclosure Type
Type 3R
Type 3R
Enclosure Finish
ANSI 61 Grey, UL50
ANSI 61 Grey, UL50
Termination
Top accessible separate high and low voltage lead wires or copper tabs.
Top accessible separate high and low voltage lead wires or copper tabs.
Conduit Knock-Outs
Standard side and rear knock-outs on all units (no knock-outs on Stainless Steel enclosures).
Standard side and rear knock-outs on all units (no knock-outs on Stainless Steel enclosures).
Impedance
Typically 4 to 8%
Typically 1 to 5%.
Mounting
Standard Wall Mounting Lifting provisions standard on all units.
Standard Wall Mounting up to (but not including) 15 kVA (optional wall mounting kit available for 15 kVA, 30 kVA and 45 kVa). Floor mount only over 45 kVA. Lifting provisions standard 6 kVA to 75 kVA.
Sound Level
Meets NEMA ST-20 standards.
Meets NEMA ST-20 standards.
Other voltages and kVA ratings not listed in this section are available upon request. Please contact customer service for details, price and availability.
© Hammond Power Solutions Inc.
196
For accessories see pages 238 to 241 Data subject to change without notice.
SECTION 8
COMMERCIAL ENCAPSULATED
THREE PHASE, NEMA 3R STYLE ENCLOSURE 208 Primary Volts kVA
Catalog Number
2 3 6 9 15 30 45 75
C3F002BBS C3F003BBS C3F006BBS C3F009BBS C3F015BBS C3F030BBS C3F045BBS C3F075BBS
208Y/120 Secondary Volts Case Style
Approx. Dimensions (Inches)
(Pages 228 - 230)
Width
Depth
Height
Approx. Weight (Lbs.)
NQT3 NQT3 NQT5 NQT6 NQT7 NQT8 NQT9 NQT9A
12.38 12.38 16.63 19.25 20.25 22.25 31.50 34.63
5.44 5.44 10.25 10.44 13.00 13.00 16.00 18.50
11.13 11.13 16.63 16.63 23.38 28.38 29.88 36.75
50 70 140 210 350 525 700 1420
60 Hz
Mtg Type W - Wall F - Floor
Wiring Diagram
(Pages 243 - 258)
W W W W F or W* F or W* F or W* F
SCD8 SCD8 SCD8 SCD8 SCD8 SCD9 SCD9 SCD9
*Optional wall mounting kit required. Refer to page 240 for details.
208 Primary Volts Catalog Number
2 3 6 9 15 30 45 75
C3F002BKS C3F003BKS C3F006BKS C3F009BKS C3F015BKS C3F030BKS C3F045BKS C3F075BKS
Case Style
Approx. Dimensions (Inches)
(Pages 228 - 230)
Width
Depth
Height
Approx. Weight (Lbs.)
NQT3 NQT3 NQT5 NQT6 NQT7 NQT8 NQT9 NQT9A
12.38 12.38 16.63 19.25 20.25 22.25 31.50 34.63
5.44 5.44 10.25 10.44 13.00 13.00 16.00 18.50
11.13 11.13 16.63 16.63 23.38 28.38 29.88 36.75
50 70 140 210 350 525 700 1420
60 Hz
Mtg Type W - Wall F - Floor
Wiring Diagram
(Pages 243 - 258)
W W W W F or W* F or W* F or W* F
SCD23 SCD23 SCD23 SCD23 SCD23 SCD26 SCD26 SCD26
*Optional wall mounting kit required. Refer to page 240 for details.
240 Primary Volts kVA
Catalog Number
2 3 6 9 15 30 45 75
C3F002DBS C3F003DBS C3F006DBS C3F009DBS C3F015DBS C3F030DBS C3F045DBS C3F075DBS
208Y/120 Secondary Volts Case Style
Approx. Dimensions (Inches)
(Pages 228 - 230)
Width
Depth
Height
Approx. Weight (Lbs.)
NQT3 NQT3 NQT5 NQT6 NQT7 NQT8 NQT9 NQT9A
12.38 12.38 16.63 19.25 20.25 22.25 31.50 34.63
5.44 5.44 10.25 10.44 13.00 13.00 16.00 18.50
11.13 11.13 16.63 16.63 23.38 28.38 29.88 36.75
50 70 140 210 350 525 700 1420
60 Hz
Mtg Type W - Wall F - Floor
Wiring Diagram
(Pages 243 - 258)
W W W W F or W* F or W* F or W* F
SCD8 SCD8 SCD8 SCD8 SCD8 SCD9 SCD9 SCD9
*Optional wall mounting kit required. Refer to page 240 for details
240 Primary Volts kVA
Catalog Number
2 3 6 9 15 30 45 75
C3F002DKS C3F003DKS C3F006DKS C3F009DKS C3F015DKS C3F030DKS C3F045DKS C3F075DKS
480Y/277 Secondary Volts Case Style
Approx. Dimensions (Inches)
(Pages 228 - 230)
Width
Depth
Height
Approx. Weight (Lbs.)
NQT3 NQT3 NQT5 NQT6 NQT7 NQT8 NQT9 NQT9A
12.38 12.38 16.63 19.25 20.25 22.25 31.50 34.63
5.44 5.44 10.25 10.44 13.00 13.00 16.00 18.50
11.13 11.13 16.63 16.63 23.38 28.38 29.88 36.75
50 70 140 210 350 525 700 1420
60 Hz
Mtg Type W - Wall F - Floor
Wiring Diagram
(Pages 243 - 258)
W W W W F or W* F or W* F or W* F
SCD23 SCD23 SCD23 SCD23 SCD23 SCD26 SCD26 SCD26
*Optional wall mounting kit required. Refer to page 240 for details.
© Hammond Power Solutions Inc.
197
For accessories see pages 238 to 241 Data subject to change without notice.
SECTION 8
kVA
480Y/277 Secondary Volts
SECTION 8
HPS FORTRESS™
THREE PHASE, NEMA 3R STYLE ENCLOSURE 480 Primary Volts kVA
Catalog Number
2 3 6 9 15 30 45 75
C3F002KBS C3F003KBS C3F006KBS C3F009KBS C3F015KBS C3F030KBS C3F045KBS C3F075KBS
208Y/120 Secondary Volts Case Style
Approx. Dimensions (Inches)
(Pages 228 - 230)
Width
Depth
Height
Approx. Weight (Lbs.)
NQT3 NQT3 NQT5 NQT6 NQT7 NQT8 NQT9 NQT9A
12.38 12.38 16.63 19.25 20.25 22.25 31.50 34.63
5.44 5.44 10.25 10.44 13.00 13.00 16.00 18.50
11.13 11.13 16.63 16.63 23.38 28.38 29.88 36.75
50 70 140 210 350 525 700 1420
60 Hz
Mtg Type W - Wall F - Floor
Wiring Diagram
(Pages 243 - 258)
W W W W F or W* F or W* F or W* F
SCD8 SCD8 SCD8 SCD8 SCD8 SCD9 SCD9 SCD9
*Optional wall mounting kit required. Refer to page 240 for details.
SECTION 8
480 Primary Volts kVA
Catalog Number
2 3 6 9 15 30 45 75
C3F002KDS C3F003KDS C3F006KDS C3F009KDS C3F015KDS C3F030KDS C3F045KDS C3F075KDS
240D Secondary Volts Case Style
Approx. Dimensions (Inches)
(Pages 228 - 230)
Width
Depth
Height
Approx. Weight (Lbs.)
NQT3 NQT3 NQT5 NQT6 NQT7 NQT8 NQT9 NQT9A
12.38 12.38 16.63 19.25 20.25 22.25 31.50 34.63
5.44 5.44 10.25 10.44 13.00 13.00 16.00 18.50
11.13 11.13 16.63 16.63 23.38 28.38 29.88 36.75
50 70 140 210 350 525 700 1420
60 Hz
Mtg Type W - Wall F - Floor
Wiring Diagram
(Pages 243 - 258)
W W W W F or W* F or W* F or W* F
SCD12 SCD12 SCD12 SCD12 SCD12 SCD38 SCD38 SCD38
*Optional wall mounting kit required. Refer to page 240 for details.
600 Primary Volts kVA
Catalog Number
2 3 6 9 15 30 45 75
C3F002PBS C3F003PBS C3F006PBS C3F009PBS C3F015PBS C3F030PBS C3F045PBS C3F075PBS
208Y/120 Secondary Volts Case Style
Approx. Dimensions (Inches)
(Pages 228 - 230)
Width
Depth
Height
Approx. Weight (Lbs.)
NQT3 NQT3 NQT5 NQT6 NQT7 NQT8 NQT9 NQT9A
12.38 12.38 16.63 19.25 20.25 22.25 31.50 34.63
5.44 5.44 10.25 10.44 13.00 13.00 16.00 18.50
11.13 11.13 16.63 16.63 23.38 28.38 29.88 36.75
50 70 140 210 350 525 700 1420
60 Hz
Mtg Type W - Wall F - Floor
Wiring Diagram
(Pages 243 - 258)
W W W W F or W* F or W* F or W* F
SCD8 SCD8 SCD8 SCD8 SCD8 SCD9 SCD9 SCD9
*Optional wall mounting kit required. Refer to page 240 for details.
600 Primary Volts kVA
Catalog Number
2 3 6 9 15 30 45 75
C3F002PDS C3F003PDS C3F006PDS C3F009PDS C3F015PDS C3F030PDS C3F045PDS C3F075PDS
240D Secondary Volts Case Style
Approx. Dimensions (Inches)
(Pages 228 - 230)
Width
Depth
Height
Approx. Weight (Lbs.)
NQT3 NQT3 NQT5 NQT6 NQT7 NQT8 NQT9 NQT9A
12.38 12.38 16.63 19.25 20.25 22.25 31.50 34.63
5.44 5.44 10.25 10.44 13.00 13.00 16.00 18.50
11.13 11.13 16.63 16.63 23.38 28.38 29.88 36.75
50 70 140 210 350 525 700 1420
60 Hz
Mtg Type W - Wall F - Floor
Wiring Diagram
(Pages 243 - 258)
W W W W F or W* F or W* F or W* F
SCD12 SCD12 SCD12 SCD12 SCD12 SCD45 SCD45 SCD45
*Optional wall mounting kit required. Refer to page 240 for details.
© Hammond Power Solutions Inc.
198
For accessories see pages 238 to 241 Data subject to change without notice.
SECTION 8
INDUSTRIAL ENCAPSULATED
HPS Titan® Applications The HPS Titan® line of transformers have been designed for installation in harsh environments where efficiency and performance are key. Typical applications include institutional, commercial, industrial, petrochemical, marine, mining, etc. HPS Titan® designs provide:
• Superior Performance • Compact Efficient Design • Easy Installation and Hook-up
HHPS Titan® Series transformers are UL Listed for “Class 1, Division 2, Groups A, B, C, D and Class I, Zone 2 Group IIC, T3C Hazardous Locations” and also meet ABS Type Approval for “Marine Duty Service and Offshore Applications - Electrical Distribution and Propulsion”. With a North American Temperature Classification of T3C/T3A, the HPS Titan Series will remain cool under load.
HPS Titan® Features and Benefits Single Phase
Three Phase
Voltage Groups
5 standard voltage groups
5 standard voltage groups
Ratings
0.5 kVA to 37.5 kVA
2 kVA to 150 kVA
Frequency
60 Hz (50/60 Hz on units with 380V primary)
60 Hz (50/60 Hz on units with 380V primary)
Electrostatic Shield
Optional on 0.50 kVA Standard on 0.75 kVA to 37.5 kVA
Standard on all units
Encapsulated
All units are encapsulated with electrical grade silica sand and resin compounds
Enclosure
Heavy duty type 3R Optional type 4, 4X (stainless steel) and 12
Heavy duty type 3R Optional type 4, 4X (stainless steel) and 12 Optional gasket kit
Terminations
Front accessible separated high and low voltage lead wires or copper tabs
Top accessible separate high and low voltage lead wires or copper tabs
Insulation System
130°C (80°C rise) up to 1 kVA - standard 180°C (115°C rise) 1.5 kVA to 37.5 kVA - standard 180°C (80°C rise) 1.5 kVA to 37.5 kVA - optional
130°C (80°C rise) up to 5 kVA - standard 180°C (115°C rise) 6 kVA to 150 kVA - standard 180°C (80°C rise) 6 kVA to 150 kVA - optional
Mounting
Standard wall mounting with keyhole mounting slots. Lifting provisions standard from 5 kVA to 37.5 kVA.
Standard wall mounting with keyhole mounting slots 2 kVA to 15 kVA (Optional wall mounting kit available for 30 kVA and 45 kVA). Floor Mounted 25 kVA to 150 kVA. Lifting provisions standard on 6 kVA to 150 kVA.
Conduit Knockouts
For rear and side entry into an easily accessible and spacious wiring compartment (no knock-outs on Stainless Steel enclosures).
Approvals
ANSI/ISA 12.12.10 - File No. E258346 (Class 1, Division 2, Groups A, B, C, D and Class I, Zone 2, Group IIC, T3 Hazardous Locations) T3C Temperature Classification for 80°C rise units T3A Temperature Classification for 115°C rise units UL 508 Listed - File No. E258346 UL Certificate No. 14-HS1174640-PDA (Marine Duty Service and Offshore Applications) ABS Type Approval
Warranty
All HPS standard catalog encapsulated transformers come with a 10 year limited warranty (please refer to the HPS standard Catalog Transformer Products Warranty for full details)
© Hammond Power Solutions Inc.
199
For accessories see pages 238 to 241 Data subject to change without notice.
SECTION 8
Features
SECTION 8
HPS TITAN®
HPS TITAN® TRANSFORMERS FOR HARSH ENVIRONMENTS AND HAZARDOUS LOCATIONS SINGLE PHASE STANDARD SPECIFICATIONS
SECTION 8
0.50 TO 1 KVA
1.5 TO 37.5 KVA
0.50 kVA to 1 kVA
1.5 kVA to 37.5 kVA
ANSI/ISA 12.12.10
File No. E258346 (Class 1, Division 2, Groups A, B, C, D and Class I, Zone 2, Group IIC, T3 Hazardous Locations) - T3C Temperature Classification
File No. E258346 (Class 1, Division 2, Groups A, B, C, D and Class I, Zone 2, Group IIC, T3 Hazardous Locations) - T3C/T3A Temperature Classification
ABS Type Approval (RQS)
Certificate No.: 14-HS1174640-PDA
Certificate No.: 14-HS1174640-PDA
North American Temperature Classification
T3C Approval
T3C Approval for 80°C rise units T3A Approval for 115°C rise units
Frequency
60 Hz (50/60 Hz on units with 380V primary)
60 Hz (50/60 Hz on units with 380V primary)
Insulation System
130°C (80°C rise) standard on all units.
180°C (115°C rise) standard on all units. Optional 180°C (80°C rise) available.
Electrostatic Shield
Optional on 0.50 kVA. Standard on 0.75 kVA and 1 kVA.
Standard on all units.
Encapsulation
All units are encapsulated with electrical grade silica sand and resin compounds.
All units are encapsulated with electrical grade silica sand and resin compounds.
Heavy duty type 3R
Heavy duty type 3R
Optional type 4, 4X (stainless steel) and 12
Optional type 4, 4X (stainless steel) and 12
Enclosure Finish
ANSI 61 Grey, UL50
ANSI 61 Grey, UL50
Termination
Front accessible separate high and low voltage lead wires or copper tabs.
Front accessible separate high and low voltage lead wires or copper tabs.
Conduit Knock-Outs
Standard side and rear knock-outs on all units (no knock-outs on Stainless Steel enclosures).
Standard side and rear knock-outs on all units (no knock-outs on Stainless Steel enclosures).
Impedance
Typically 5 to 10% on 0.50 kVA. Typically 1 to 5% on 0.75 kVA and 1 kVA
Typically 1 to 5%.
Mounting
Standard Wall Mounting Lifting provisions standard on all units.
Standard Wall Mounting Lifting provisions standard on units.
Seismic
Seismically certified in accordance with IBC 2009; Section 1613 Earthquake Loads, for SDS