energizer 337 product datasheet - Energizer Technical Information

Report 2 Downloads 184 Views
PRODUCT DATASHEET 1-800-383-7323 1-800-383-7323 / USA USA/CAN 1-800-383-7323 / CANADA www.energizer.com

ENERGIZER 337

SILVER OXIDE

Specifications

Industry Standard Dimensions mm (inches)

Chemical System:

Silver Oxide (Zn/Ag2O)

Nominal Voltage: Typical Capacity: Capacity Test: Typical Weight: Typical Volume: Impedance (40 Hz):

1.55 Volts 8.3 mAh* (to 1.2 volts) 100K ohm continuous drain at 21°C 0.13 grams (0.004 oz.) 0.03 cubic centimeters (0.001 cubic inch) 75 to 85 ohms

* Varies according to the applied load, temperature, and cutoff voltage.

3.50 (0.138) Ref.

4.80 (0.189)

2.90 (0.114) Ref.

4.65 (0.183)

Cross Section

1.65 (0.065)

E

1.50 (0.059)

R0.95 (0.037) Ref.

1.57 (0.062) Ref.

R0.45 (0.018) Ref.

LE T

1.37 (0.054) Ref.

Anode Cap Gel Anode Gasket Can Separator

0.15 (0.006) Maximum Ref. Permissible deflection from a flat

O

0.03 (0.001) Minimum Ref. (applies to top edge of gasket or edge of crimp, whichever is higher)

Cathode

DESIGNED FOR USE ON CONTINUOUS LOW DRAIN

Temperature Characteristics

Typical Performance at 21°C (70°F)

Typical Performance at Low Discharge Rates

BS

Typical Discharge Characteristics

Service (%)

O

1.7 1.6 1.5 1.4 1.3 1.2 1.1 1.0

Service Effects 125 100 75 50 25 0 -20

0

150

Schedule

Continuous

300 Service, Hours

450

600

Typical Drains at 1.55V (milliamperes)

(ohm)

Cutoff 1.2V (hours)

0.016

100K

519

Load

0 20 Temperature (C)

40

Storage Effects 100 Service (%)

Voltage, CCV

Schedule: Continuous Typical Drain @1.55V: 0.016 milliamperes Load: 100K ohm

0 C

90

20 C

80 70

40 C

60 0

2

4 6 8 Storage Time (yrs)

10

12

Important Notice

This datasheet contains typical information specific to products manufactured at the time of its publication. ©Energizer Holdings, Inc. - Contents herein do not constitute a warranty. Form No. EBC - 4313F