F Pilot Operated Check Valves

Report 6 Downloads 44 Views
Pilot Operated Check Valves

27 Series Load Holding

Single, without Trapped Pressure Relief 2-Way 2-Position, Pressure Controlled Ports Size

Valve Model Number*

Signal Port

CV

Weight lb (kg)

1/4

2751A2908

1/8-27 NPT

2.2

2.3 (1.0)

3/8

2751A3908

1/8-27 NPT

2.9

2.3 (1.0)

1/2

2751A4915

1/8-27 NPT

3.2

2.3 (1.0)

* NPT port threads. For BSPP threads, add a “D” prefix to the model number, e.g.,D2751A2908. Valve Dimensions – inches (mm) 1/8-27 NPT SIGNAL PORT

1/8-27 NPT SIGNAL PORT

1/4-18 NPT (2X) 1.72 (43.6) 1.27 (32.2)

Port Size 1/4

0.35 (9.0)

1.26 (32.1)

(2X) 1.72 (43.6)

0.44 (11.1) 1.5 (38.1)

0.75 (19.1)

1/8-27 NPT SIGNAL PORT

(2X) 1.72 (43.6) 1.21 (30.1) 0.35 (9.0)

1.26 (32.1)

1/8-27 NPT SIGNAL PORT

1.26 (32.1) 1.99 (50.4)

1/8-27 NPSM SIGNAL PORT

3/8-18 NPT

Port Size 3/8

(2X) 3.25 1/4-18 (82.5) NPT 3.67 (93.7) 0.83 (21.1)

(2X) 3.25 3/8-18 (82.5) NPT 3.69 (93.7) 0.77 (19.56)

(2X) 1.72 (43.6)

1.5 (38.1)

0.75 (19.1)

1.26 (32.1) 1.99 (50.4)

0.33 (8.5) 1.5 (38.1)

0.75 (19.1)

1/2-14 NPT

1/8-27 NPT SIGNAL PORT 0.52 (13.2)

1.28 (32.5)

0.49 (12.45)

0.75 (19.1) (2X)

0.37 (9.4)

3.35 (85.6) 3.79 (96.3)

1.75 (44.5)

1.48 (37.6)

F4

0.44 (11.1)

1/2-14 NPT

Port Size 1/2

0.75 (19.1) (2X)

0.37 (9.4)

1.48 (37.6) 2.47 (62.5)

F

0.75 (19.1) (2X)

0.50 (12.7)

Cylinder

Single Pilot Operated Check Valve Application

CIRCUIT FEATURES: • Cylinder moves as long as the control valve solenoid is energized. Use for continuous motion or jogging. • Cylinder remains stationary if neither control valve solenoid is energized, or if electrical signal is lost.

Flow Control Valves

Check Valve with CYL Internal Pilot

Check Valve with Internal Pilot CYL VALVE

VALVE

L-O-X Valve

3- Position, OpenCenter Control Valve

STANDARD SPECIFICATIONS (for valves on this page): Construction: Poppet. Mounting Type: In-Line. Ambient/Media Temperature: 40° to 175°F (4° to 80°C).

Inlet Pressure: 15 to 150 psig (1 to 10.3 bar). Flow Media: Filtered air. Signal Pressure: Must be equal to or greater than inlet pressure.

IMPORTANT NOTE: Please read carefully and thoroughly all of the CAUTIONS, WARNINGS on the inside back cover. Online Version Rev. 05/16

www.rosscontrols.com

F4.5