Molded Case Circuit Breakers
Industrial Circuit Breakers 15-150A Circuit Breakers Thermal-Magnetic Trip E150 Line Circuit Breakers Types TEB, TED, THED Noninterchangeable Trip Note: All UL listed as HACR type except 10 ampere 60°C/75°F Conductor 10-150 Amperes Rating Through 100 Amperes 120-600 Vac 75°C above 100 Amperes 125, 250 Vdc
Single Pole — Includes Cu/Al load lugs only. If line lugs are required, add suffix “WL” to Product Number. Type TEB Ampere Rating 10 15 20 25 30 35 40 45 50 60 70 80 90 100
Type TED
120 Vac 125 Vdc
347 Vac1
277 Vac 125 Vdc
Product Number
List Price
Product Number
TEB1110102 TEB1110153 TEB1110203 TEB111025 TEB111030 TEB111035 TEB111040 TEB111045 TEB111050 TEB111060 TEB111070 TEB111080 TEB111090 TEB111100
$78.50 $78.50 $78.50 $78.50 $78.50 $78.50 $78.50 $78.50 $78.50 $78.50 $134.00 $134.00 $134.00 $134.00
TED1130102 TED1130153 TED1130203 TED113025 TED113030 TED113035 TED113040 TED113045 TED113050 TED113060 TED113070 TED113080 TED113090 TED113100
GO-135B
Type THED
List Price $82.50 $82.50 $82.50 $82.50 $82.50 $82.50 $82.50 $82.50 $82.50 $82.50 $159.00 $159.00 $159.00 $159.00
347 Vac1
277 Vac
Product Number
List Price
Product Number
List Price
TED1140153 TED1140203 TED114025 TED114030 — — — — — — — — —
$152.00 $152.00 $152.00 $152.00 — — — — — — — — —
THED113015 THED113020 THED113025 THED113030 — — — — — — — — —
$229.00 $229.00 $229.00 $229.00 — — — — — — — — —
Product Number THED1140153 THED1140203 THED114025 THED114030 — — — — — — — — —
Two Pole — Includes Cu/Al line and load lugs. For optional lugs, see page 3-101 and 3-102.
MOLDED CASE CIRCUIT BREAKERS
Type TEB
3
240 Vac, 250 Vdc
480 Vac, 250 Vdc
Product Number
List Price
Product Number
10 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 150
TEB122010WL2 TEB122015WL TEB122020WL TEB122025WL TEB122030WL TEB122035WL TEB122040WL TEB122045WL TEB122050WL TEB122060WL TEB122070WL TEB122080WL TEB122090WL TEB122100WL — — —
$159.00 $159.00 $159.00 $159.00 $159.00 $159.00 $159.00 $159.00 $159.00 $159.00 $261.00 $261.00 $261.00 $261.00 — — —
TED124010WL2 TED124015WL TED124020WL TED124025WL TED124030WL TED124035WL TED124040WL TED124045WL TED124050WL TED124060WL TED124070WL TED124080WL TED124090WL TED124100WL TED124110WL TED124125WL TED124150WL
$416.00 $416.00 $416.00 $416.00 — — — — — — — — —
GO-135B Type THED, Hi-Break 4
Type TED
Ampere Rating
List Price
List Price $290.00 $290.00 $290.00 $290.00 $290.00 $290.00 $290.00 $290.00 $290.00 $290.00 $377.00 $377.00 $377.00 $377.00 $1000.00 $1000.00 $1000.00
480 Vac, 250 Vdc Product Number
List Price
— THED124015WL THED124020WL THED124025WL THED124030WL THED124035WL THED124040WL THED124045WL THED124050WL THED124060WL THED124070WL THED124080WL THED124090WL THED124100WL — — —
— $560.00 $560.00 $560.00 $560.00 $560.00 $560.00 $560.00 $560.00 $560.00 $653.00 $653.00 $653.00 $653.00 — — —
1Suitable for 10 kAIC at 480 Vac, but not labeled or UL listed. 2Not UL listed 3Single-pole, 15-and 20-ampere breakers are also UL listed as switching duty breakers, suitable for switching 120 Vac (TEB), 277, 347 Vac (TED, THED) fluorescent lighting loads. 4Two-pole breaker is furnished in three-pole case.
3-50 Prices and data subject to change without notice
BuyLog Catalog
www.geelectrical.com
Rev. 12/04
Molded Case Circuit Breakers
Industrial Circuit Breakers 10-1200A Circuit Breakers Thermal Magnetic Trip Ratings do not apply to molded case switches. The interruption ratings and voltages shown in the table are maximum ratings. A circuit breaker of the type given in the left-hand column may be applied at the given circuit voltage in any electrical distribution system where the available fault current at the load terminals of the breaker does not exceed the value in the table. That circuit breaker type may also be applied at intermediate values of circuit voltage provided the available fault current at the load terminals of the breaker does not exceed the value in the table for the higher value of voltage.
TFJ, TFK, THFK
TJJ, TJK, THJK
Quick Reference Guide E150 (UL File E-11592; Fixed Thermal Magnetic Trip Unit; CSA LR 57114)
Circuit Breaker Type
TEB2
Ampere Rating
10-100 3
ac
dc
120
1
120
125
10
2
240
THED2
250 —
1
277,347 4
125
2
480
250
10-150
3
600
500
15-30
1
277,347 4
125
15-100
2
480
250
10-100 3 15-100
15-100
Vac
No. Poles
3 TED2
UL Listed Interrupting Ratings— kA
Maximum Voltage Rating
3
480,600
—
3
600
—
—
—
120/ 240
15-150
277
480
—
—
10
—
125
250
500 1
—
—
—
5 —
—
—
14
10
18
—
18
—
—
—
—
65
—
25
18
—
65
25
A
B
C
E
26 lb/24
—
—
4 1/8
10
—
—
1 3/8
10
—
10
10
4 1/8
11/16
28 lb/8
—
—
1 3/8
—
26 lb/24
205
—
205
—
65
D
—
—
—
W 1 3/8
—
14 65
H
Approx. Ship Wt./Std. Pack
5 —
—
—
Dimensions (In.)
600
—
110-150 TEL6
240
Vdc
—
6 5/16
6 5/16
2 3/4
2 3/4
6 5/16
10
—
—
—
3 3/8
2 41/64 2 15/64
23/32 11/16
28 lb/8 26 lb/24
— 3 3/8
3 3/8
2 41/64 2 15/64
23/32
2 41/64 2 15/64
23/32
4 1/8
11/16
4 1/8
3 29/32 2 7/16 2 15/32 11/16
24 lb/12
24 lb/12
24 lb/12 28 lb/8
42 —
100
100
—
6 5/16
23/32
3 1/2 lb/1
Approx. Ship Wt./Std. Pack
F225 (UL File E-11592; TFJ, Fixed Thermal Magnetic Trip Unit; TFK, THFK: Interchangeable Thermal Mag. Trip Unit; CSA LR 40350) UL Listed Interrupting Ratings— kA
MOLDED CASE CIRCUIT BREAKERS
Circuit Breaker Type
3
TFJ
2
2
Maximum Voltage Rating Ampere Rating
No. Poles
ac
dc
70-225
2
480
250
70-250
3
600
500
2
480
250
70-225
TFK
2
THFK
70-225
TFL6
70-225
Vac 120
120/ 240
240
277
480
250
500 1
10
—
18
10
10
12 lb/1
—
10
—
10 lb/1
—
—
5
—
600
125
— —
—
—
—
25
25
—
—
22
22
—
3
600
—
18
2
480
250
—
3
600
—
3
600
—
—
—
65
—
25
—
—
20 —
—
—
—
—
18 —
100
100
—
Dimensions (In.)
Vdc
65
25
H
W
D
A
B
C
E
10 1/8
4 1/8
3 13/16
3 7/8
3 7/8
11/16
1 3/16
10 1/8
4 1/8
3 13/16
3 7/8
3 7/8
11/16
1 3/16
10 lb/1
12 lb/1 10 1/8
4 1/8
3 13/16
3 7/8
3 7/8
11/16
1 3/16
10 1/8
4 1/8
3 13/16
3 7/8
3 7/8
11/16
1 3/16
1 3/8
1 3/16
10 lb/1 12 lb/1 —
J600 (UL File E-11592; TJJ, Fixed Thermal Magnetic Trip Unit; TJK, THJK: Interchangeable Thermal Mag. Trip Unit; CSA LR 40350) TJJ, TJK4
125-400
TJK6
250-600
THJK4
2
600
125-400
250-600
—
—
42
—
30
22
—
10
—
20
10 1/8
8 1/4
3 13/16 3 15/16 3 13/16
16 lb/1
10
3
500
20
20
20 lb/1
2
250
40
—
16 lb/1
—
—
40
—
—
—
2
500 600
600
3 THJK6
250
208 —
3
2
600
3
250
— 250 —
—
—
—
—
—
—
42
65
65
—
—
—
30
35
35
22
25
25
—
—
—
17 1/2 lb/1 10 1/8
10 1/8
8 1/4
8 1/4
3 13/16 3 15/16 3 13/16
3 13/16 3 15/16 3 13/16
1 3/8
1 3/8
1 3/16
1 3/16
18 lb/1
17 1/2 lb/1 10 1/8
8 1/4
3 13/16 3 15/16 3 13/16
1 3/8
1 3/16
18 lb/1 20 lb/1
K1200 (UL File E-11592; Interchangeable Thermal Magnetic Trip Unit; CSA LR 40350) TKM8
300-800
2
600
TKM12
600-1200
2
250
—
—
42
—
30
22
—
500
3 600
—
—
—
42
—
30
22
—
10
—
20
22
—
—
15 1/2
8 1/4
5 1/2
8 9/16 5 11/16
1 3/8
5/8
15 1/2
8 1/4
5 1/2
8 9/16 5 11/16
1 3/8
5/8
39 lb/1
300-800
2
600
3 THKM12 600-1200
2
38 lb/1 41 1/2 lb/1
3 THKM8
33 lb/1
600
250 — —
—
—
—
—
65
65
—
—
35
35
25
25
—
—
407
—
—
—
—
—
15 1/2
8 1/4
5 1/2
8 9/16 5 11/16
1 3/8
5/8
33 lb/1 39 lb/1
15 1/2
8 1/4
5 1/2
8 9/16 5 11/16
1 3/8
5/8
38 lb/1 41 1/2 lb/1
3 1 UL listed with poles in series for 500 Vdc ungrounded battery applications. 2 All UL listed as HACR type. 3 10 amp not UL listed. 4 UL listed/CSA Certified for 10kA @ 347 Vac (TED) and 18kA @ 347V
5 UL listed at 10,000 amps. 6 Discontinued 7 Also 10,000 amps at 500 Volts dc. Not UL listed. 8 500 Vdc on TJJ only.
(THED). Also rated 10kA @ 480V but not UL listed.
3-46 Prices and data subject to change without notice
BuyLog Catalog
www.geelectrical.com
Rev. 12/04