GE Lumination BT Series LED Luminaire Installation ...

Report 8 Downloads 64 Views
Installation Guide

GE Lighting

Lumination LED Luminaires TM

(BT Series UL Version – EL Emergency Light Option)

BT22 Series

BT14 & BT24 Series

IMPORTANT SAFEGUARDS

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED INCLUDING THE FOLLOWING:

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. Turn power off before inspection, installation or removal. 2. To reduce the risk of electric shock, disconnect both normal and emergency power suppliers and converter connector of the emergency driver before servicing. 3. The emergency driver must be fed from the same branch circuit as the AC driver. 4. Do not attempt to service the battery. A sealed, no-maintenance battery is used that is not field replaceable. Contact the manufacturer for information on service. 5. Follow all NEC and local codes. Properly ground electrical enclosure. 6. Use only UL listed wire for input/output connections. Minimum size 18 AWG (0.75mm2). 7. Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. 8. Do not use outdoors. 9. Do not mount near gas or electric heaters. 10. Do not use this equipment for other than intended use. 11. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.

SAVE THESE INSTRUCTIONS Ni-Cd Battery

The rechargeable Nickel-Cadmium battery in this product must be recycled or disposed of properly.

imagination at work

BEFORE YOU BEGIN

Read these instructions completely and carefully.

Tools and Components Required

Prepare Electrical Wiring

Fixture Installation • Phillips head screwdriver. • UL listed conduit fitting. • UL listed twist-on wire connectors.

Electrical Requirements • LED driver must be supplied with 120-277VAC 60 Hz and connected to an individual properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker. Use min. 75°C supply conductor.

Indicator Test Switch Installation • Slotted head screwdriver. • UL listed single-gang electrical box. • UL listed conduit fittings and conduit. • UL listed wire, minimum size 18 AWG (0.75mm2), min. 75°C rating. • UL listed twist-on wire connectors.

Grounding Instructions • The grounding and bonding of the overall system shall be done in accordance with National Electric Code (NEC) Article 600 and local codes.

Wiring Diagrams Caution: 1. Switched and unswitched line inputs must be provided from the same branch circuit. 2. Connect external ITS indicator test switch according to NEC and local codes. (A) Switched Fixture:

Switch Fixture Neutral Input

White

Violet

White

Brown

To external ITS (Violet)

Green

Switched Line Input

White/Red

Green (BT24/BT14 Only)

Unswitched Line Input

Ground Input

To external ITS (Brown)

Black

B) Unswitched Fixture:

Unswitched Fixture Neutral Input

Unswitched Line Input

White

Violet

White

Brown

To external ITS (Violet)

Green White/Red Black

Green (BT24/BT14 Only)

Ground Input

To external ITS (Brown)

Unit Installation BT22 Series

1

Carefully unpack unit from its packaging. Properly inspect for defects before installing. Wear work gloves to prevent dirt and oil from being transferred to the luminaire.

BT22 Series

2

BT14 & BT24 Series

BT14 & BT24 Series

Install the unit into the reserved hole in the ceiling. Note: Luminaires shall be securely fastened to the ceiling framing member by mechanical means such as bolts, screws or rivets. UL listed clips identified for use with type of ceiling framing member(s) and luminaire(s) shall also be permitted. CAUTION When utilizing mechanical means, take caution to avoid perforating electrical enclosure.

Optional Safety Brackets

Attach 4 brackets

3

Optional Earthquake Brackets

Attach 4 brackets

Optional Safety Brackets: Attach the supplied L-shape safety brackets to the back of the fixture in each corner. Hang the unit through the holes of the brackets with cable. Optional Earthquake Brackets: Position four brackets on both ends of the two long sides of the luminaire. Press brackets to fasten to grid.

Indicator Test Switch Installation 1

Important: This unit must be installed with the factoryprovided remote mount Indicator test switch (ITS). Follow National Electrical Code (NEC) and local code regulations when installing the ITS.

2

Choose a suitable location in a wall or the ceiling for the ITS. Maximum remote mounting distance for the ITS is 50 feet. Install a UL listed single-gang electrical box.

3

Using UL listed wire, minimum size 18 AWG, minimum 75°C rating, and UL listed electrical conduit, connect the leads on the ITS. Provide enough wire to reach the lighting fixture electrical enclosure. Use 18-14AWG twist-on wire connectors.

ITS Installation: BT22, BT14 & BT24 Series

Recommended: use one violet and one brown wire to match the leads on the ITS.

4

Remove one knockout from the single-gang electrical box. Using UL listed conduit, run wire from the ITS to the lighting fixture electrical enclosure.

5

Close the single-gang electrical box using the factory-provided wall plate cover and hardware.

Electrical Connections 1

Important: Make sure the necessary branch circuit wiring is available. An unswitched source of power is required. The emergency driver must be fed from the same branch circuit as the AC driver. BT22 Series

BT14 & BT24 Series

For indicator test switch

For indicator test switch For AC line

Remove cover

Remove cover

For AC line

2

Remove electrical enclosure cover. Remove knockout for AC line input wires. Install listed electrical fittings in the knockout holes for wire protection. Remove knockout for indicator test switch wires. Install listed electrical fittings in the knockout holes for wire protection. BT22 Series

BT14 & BT24 Series

To indicator test switch

To indicator test switch

To emergency driver

3

To emergency driver

Connect the conduit from the indicator test switch to the electrical enclosure. Connect the positive (violet) and negative (brown) leads of the indicator test switch to the matching leads of the emergency driver using 18-14AWG twist-on wire connectors.

BT22 Series

BT14 & BT24 Series To emergency driver

Ground wires

AC line

AC line To emergency driver

Ground

4

Connect the switched AC line input wire to the white/red (switched line) connection of the emergency driver. Connect the unswitched AC line input wire to the black (line) connection of the emergency driver. For an unswitched fixture, connect the unswitched AC line input wire to both the white/red and black wires of the emergency driver. Connect the white (neutral) input wire to the white (neutral) connection of the emergency driver and the AC LED Driver. Use 18-14AWG twist-on wire connectors. For BT22 Series: Connect the ground wire to the green grounding wire. For BT14 & BT24 Series: Connect the ground wire to the green grounding wire and driver grounding wire.

BT22 Series

5

BT14 & BT24 Series

Replace electrical enclosure cover.

This equipment is not self-testing in conformance with the Life Safety Code, ANSI/NFPA 101 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class [A] RFLD complies with the Canadian standard ICES-003. Ce DEFR de la classe [ A ] est conforme à la NMB-003 du Canada. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

GE Lighting • 1-888-MY-GE-LED (1- 8 8 8 - 6 9 - 4 3 - 5 33 ) • www.gelighting.com GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. The GE brand, logo, Lumination are trademarks of the General Electric Company. USG and Logix are trademarks of USG Interiors, LLC. © 2013 GE. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions. IND078-123013