WALLIGHTER 400 LUMINAIRE APPLICATIONS • Underpasses, loading docks and building perimeter security • Applications where a high wattage wall mounted luminaire is needed SPECIFICATION FEATURES
• / 1598 Listed
Suitable For Wet Locations • Sealed and charcoal filtered housing • Die-cast aluminum housing protected inside and out with dark bronze polyester powder paint finish • ALGLAS® finish on aluminum reflector • Heat and impact resistant prismatic glass refractor
• Pre-wired terminal board and integral direct-mounted ballast • .75 in. (19mm) NPT conduit entrances sides and top • Photoelectric receptacle available • Mogul base E39 socket standard except 150W PMH medium base socket • Magnapack packaging available
The Energy Independence and Security Act of 2007 (EISA) affects Metal Halide (MH) and Pulse Metal Halide (PMH) wattages from 175W to 450W and for domestic usage, the new digit is “E = EISA-compliant PMH” which has a minimum efficiency of 88%. In many cases, the lumen value and lamp life of a lesser wattage meets or exceeds the former MH ballast/lamp system. For 175W applications, where 175W E-PMH is not available, 150W PMH may be an acceptable substitute. 150W PMH is medium base socket unless otherwise listed or requested.
ORDERING NUMBER LOGIC W4L PRODUCT IDENT XXX W4L = Wallighter 400
25
S
WATTAGE
LIGHT SOURCE X E = Energy Act Compliant Pulse MH (EPMH) S = HPS M = MH P = PMH
XX 15 = 150 17 = 175 20 = 200 25 = 250 32 =320 35 = 350 40 = 400
Standard: Lamp not included.
0
A
1
VOLTAGE
BALLAST TYPE X X 60Hz See Ballast and 0 = 120/208/ Photometric 240/277 Selection Table Multivolt 1 = 120 A = Autoreg 2 = 208 3 = 240 G = Mag4 = 277 Reg with 5 = 480 Grounded C = 120/240/ Socket Shell 277 D = 347 H = HPF Reactor T = 220 or Lag 50Hz 6 = 220 Y = 240
PE FUNCTION X 1 = None 2 = PE Receptacle
IES DISTRIBUTION TYPE XXX See Ballast and Photometric Selection Table NOTE: Receptacle SN4 = Short, Non-cutoff, connected same Type IV voltage as unit. Vertical mounting only. Order PE Control separately.
K = Hot Restart M = Mag-Reg N = NPF Reactor or Lag P = CWI with Grounded Socket Shell
GE Lighting Systems, Inc. A-82/2008
SN4
www.gelightingsystems.com
DB
F
COLOR
OPTIONS
XX DB = Dark Bronze
XXX B = Time Delay Automatically Switched Quartz F = Fusing (Not available with multivolt) L = Latch on door S = External Slipfitter for 1-1/4 inch (32mm) diameter Pipe Mounting Ø48=External Slipfitter for 2 in. (51mm) diameter pipe mounting
WALLIGHTER 400 LUMINAIRE FIXTURE DIMENSIONS
DATA Approximate Net Weight Effective Projected Area
27-45 lbs 1.5 sq ft max
12-20 kgs 0.15 sq M max
BALLAST AND PHOTOMETRIC SELECTION TABLE All light sources are clear unless otherwise indicated. Ballast Type/Voltage 60Hz 50Hz Light Multi- 120, 208, Wattage Source volt 240, 277 347 480 220 220 240 150 (55V) HPS H,N G,H,K,M,N H,M,N M N/A N/A H,M 200, 250, 400 HPS A A,P A, P A,P A A A 150 PMH H* H H N/A N/A N/A N/A 250,320 EPMH A A N/A N/A N/A 350, 400 EPMH A A A N/A N/A N/A CANADA & EXPORT ONLY 175, 250 MH A A A A A A A 400 MH A A, P A, P A,P N/A CF CF NOTE: N/A = Not Available. CF = Contact Factory.
Photometric IES Curve Distribution Number Type 35-17 - - - SN4 9714 SN4 CF SN4 SN4
9664 CF 9713 9665
SN4 SN4
9713 9665
* = 120X240X277
REFERENCES See Page A-97 for start of Accessories. See Page A-101 for Explanation of Options and Other Terms Used.
GE Lighting Systems, Inc. www.gelightingsystems.com
2008/ A-83