Ordering: L39 Red Lens L40 Yellow Lens L41 Blue Lens L42 Amber Lens L43 Green Lens L46 MR16 Violet Blue Lens
1 3/4" MR16 Color Lens
1 3/4" MR16 Filter Lens
For use with LR1377 & LR1367 trims. Ordering: L40S Yellow Lens L41S Blue Lens L43S Green Lens L46S Small MR16 Violet Blue lens
For use with LR1377 & LR1367 trims. Ordering: L49S Sand Spread Lens L50UVS Ultra Violet Filter L53S Sand Spread Lens L54S Diffuse Spread Lens L55S Linear Spread Lens
MR11 Hex Louver
Ordering: LL11B Black LL11C Clear
MR16 Hex Louver
2008.6.10
Ordering: LL16B Black LL16C Clear LL16HD-B LL16HD-BHeavy Duty Black LL16HD-C Heavy Duty Clear
For more detail information, please see specification sheets.
www.liton.com
· LITON
131
Recessed Downlight Accessories Trim Accessories
Adjustable Hanger Bar Set
Ordering: HB24 24" Set
Socket Extender
MR16 Socket
Ordering: PE260 Medium Base
Coilex Hook Trim Spring
Ordering: PA270
Lamp Socket Holder
Ordering: PS7 For Use w/ LH7 Series Housing
Insulation Thermal Protection Sensor
Ordering: TPS90 3 Wire
2008.6.10
Ordering: SPR1 Metal Ring
Ordering: PMR16 24" Wire
Flexible Socket Extender
132 LITON ·
www.liton.com
For more detail information, please see specification sheets.
Recessed Downlight Accessories LFB2012 · Fire Barrier
9 1/2" 25 3/8"
17 3/8"
This galvanized welded steel enclosure is rated (able) for one-hour resistance to active fire. LFB2012 enclosure is designed for use with both existing and new installation of Recessed Luminaires. Fulfills the required 1-hour-fire-resistance-rating, to operate as an active fire wall, with less effort. FEATURES • 24GA Galvanized welded steel constructed body • 4 flanges with 3/16" nail/screw openings • 16"/24" (apart) joist/stud applicable • (6)1/2" knockouts provided for wire access • UL/NFPA/ASTM evaluated; ETL certified. INSTALLATION The LFB2012 requires a minimum of 9 1/2" Steel Stud or Wood Joist, and must be spaced either 16" or 24" apart. The Luminaire affixes to the interior of the Fire Barrier, LFB2012 using self-tapping screws. OPERATION Liton's LFB2012 acts as a physical barrier to stop the progress of an active fire. This onehour minimum rating enclosure meets that of a typical 3/8" drywall barrier. This unit eliminatees the requirement to specify more costly fire rated luminaires and labor, such as, hand constructed drywall enclosures. Which normally are not consistent of uniform in their construction, as well as their ability to maintain the fire stop.
2008.6.10
STANDARD APPROVALS • ASTM-E119-00a • UL263 • UBC 7-1 • NFPA 251 • ASI A2.1
Example: LFB2012 Options LFB2012 19 3/8 X 12 X 9 1/2
For more detail information, please see specification sheets.
APPLICATIONS: • For cutting round holes in ceilings, walls and floors (in sizes ranging from 1 1/2" to 6 5/8" in Diameter) • Cuts plywood, plasterboard and acrylic sheet up to 2.3cm thick (when using Blade "A" which is included). • Drilling from the opposite side allows cuts up to 4.5 cm thick. • For cutting aluminum, brass and metal sheets up to 1mm thick (when using Blade "B" which is also included). FEATURES:
ACCESSORIES PH1 :Drill PH2 :Upright Axle PH3 :Transverse Axle PH4 :Blade A (Long) PH5 :Blade B (Short) PH6 :Fixed Disk PH7 :Fixed Adjusting Disk PH8 :Adjusting Rod PH9 :Gasket PH10 :Support PH19 :Balance Bar PH22 :Hexagonal Wrench Example: LW3000 Cutting Diameter LW3000 Cutting O.D 1 1/4'' to 3 7/8'' LW6000 Cutting O.D 1 1/2'' to 6 7/8'' LW8000 Cutting O.D 2'' to 8''
136 LITON ·
www.liton.com
For more detail information, please see specification sheets.
2008.6.10
1. Support base steadies the drill bit while cutting and keeps the cut perpendicular to the surface. 2. Transparent bowl/shield helps prevent debris from flying into eyes and body while cutting and reduces your clean-up because the bowl captures most of the debris. 3. Compression spring absorbs vibrations while cutting. 4. Cutting depth is freely adjustable via hex locknut and compression spring. 5. Cutting radius is freely adjustable via adjusting lever. 6. Can be used with any variable speed drill and drill press.