Grounding BURNDY® Products

Report 81 Downloads 12 Views
BURNDY® Products

Grounding Mechanical

TYPE GRC HIGH STRENGTH GROUND ROD CLAMP For Copper Cable to Rod High copper alloy ground connector for E-44 joining a range of cable to copper clad, galvanized steel, and stainless steel ground rods. Slips over end of rod, one-wrench installation. UL467 Listed for direct burial in earth and concrete.

REA LISTED

Catalog Number GRC12 GRC58 GRC34

TYPE GCRT1/0 GROUND CONNECTORS

Drive Rod 1/2 5/8 3/4

Conductor Range Min. Max. 10 Sol. 8 Sol.

2 Str. 1 Str. 1/0 Str.

H

W

L

J

2.00 2.19 2.47

.89 .95 1.09

.63 .63 .65

3/8

Features and Benefits

! W NE

• Range taking design helps reduce inventory. • UL and CSA Listed. • UL 467 Listed for direct burial in earth and concrete.

GROUND CLAMP RANGE TAKING, UP TO 1/0 The GCRT1/0 is a range taking ground rod clamp offering another choice from the BURNDY® family of connectors. The GCRT1/0 works on 1/2⬙, 5/8⬙ and 3/4⬙ ground rods with a wire range of #8 through 1/0! The clamp is UL467 Listed for direct burial in earth and concrete. Catalog number GCRT1/0.

TYPE GRL LIGHT DUTY ECONOMICAL GROUND ROD CLAMP UL 467 Listed. Acceptable for direct burial.

Catalog Number

Rod Size

GRL3* GRL4 GRL5 GRL6

3/8 1/2 5/8 3/4

Conductor Range Minimum Maximum 10 AWG 10 AWG 10 AWG 10 AWG

4 AWG 2 AWG 2 AWG 2 AWG

* GRL3 not UL Listed.

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products. Canada: 1-800-387-6487

www.burndy.com

US: 1-800-346-4175

You’re Here: Product Catalog - Rigid Conduit & IMC Fittings

Zinc Die Cast Insulated Grounding Bushings Application

Rigid Conduit & IMC Fittings EMT Conduit Fittings Liquid Tight Conduit Fittings

Used with locknut to terminate service conduit to cabinet. Lug provided for bonding jumper to neutral busbar. Grounding lug; aluminum alloy 6061-T6. Plastic metaliner prevents damage to wire insulation. Rated 150° C. Specifications and Certifications

Portable Cord Fittings Flexible Metal Conduit & Armored Cable Fittings Non Metallic Cable Fittings

Click on catalog number below.

Metal Clad Cable Fittings Grounding Fittings

Grounding Grounding Lug Lug Wire Capacity Wire Capacity Solid Strand Solid Strand Min Max

Catalog Number

UPC Number

Trade Size

Unit Qty

Std Pkg Qty

WeightLbs Per C

381-DC

09381

1/2"

50

500

5.1

#14

#4

Miscellaneous Fittings

382-DC

09382

3/4"

50

500

7.0

#14

#4

Signaling Products

383-DC

09383

1"

25

250

9.7

#14

#4

Material Specifications

384-DC

09384

1 1/4"

20

200

17.3

#14

#1/0

384DC14

93841

1 1/4"

20

200

12.5

#14

#4

385-DC

09385

1 1/2"

20

200

20.3

#14

#1/0

385DC14

93851

1 1/2"

20

200

15.4

#14

#4

386-DC

09386

2"

10

100

27.4

#14

#1/0

386DC14

93861

2"

10

100

22.8

#14

#4

387-DC

09387

2 1/2"

Bulk

25

40.4

#14

#1/0

387DC40

93874

3 1/2"

Bulk

25

54.0

#6

#250MCM

388-DC

09388

3"

Bulk

25

47.6

#14

#1/0

388DC40

93884

3"

Bulk

25

61.6

#6

#250MCM

389-DC

09389

3 1/2"

Bulk

25

52.4

#14

#1/0

389DC40

93894

3 1/2"

Bulk

25

66.0

#6

#250MCM

390-DC

09390

4"

Bulk

20

61.0

#14

#1/0

390DC40

93904

4"

Bulk

25

74.0

#6

#250MCM

Clamps & Hangers Service Entrance Cable & Conduit Fittings Voice & Data

Material Data Safety Sheets

Click here to have some free Bridgeport products sent to you at no charge! Click here to view the Bridgeport Switch Product Line Training Module

BURNDY®

Products

Mechanical TYPES KA-U, KKA-U UNIVERSAL TERMINAL A-24

(One Conductor) For Aluminum and Copper Conductors These dual-rated one-conductor lugs are constructed from high strength aluminum alloy and electro tin-plated to provide low contact resistance.

Fig. 1

Fig. 2

AL9CU

Fig. 3

CATALOG NUMBER*

FIG. NO.

WIRE RANGE ALUMINUM OR COPPER

KA6U KA2U KA25U KA26U KA29U KA30U KA31U KA34U KA36U KA40U KA44U KKA31U-2N KA36U-2N KA40U-2N KA44U-2N

1 1 1 2 2 2 2 2 2 2 2 3 4 4 4

14 STR. - 6 STR. 14 STR. - 2 STR. 14 STR. - 1/0 STR. 6 STR. - 2/0 STR. 6 STR. - 250 6 STR. - 300 6 STR. - 350 4 STR. - 500 2 STR. - 600 300 - 800 500 - 1000 6 STR. - 350 2 STR. - 600 300 - 800 500 - 1000

* "N" indicates NEMA standard stud holes. ▲ Listed torque values are for maximum conductor sizes accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor sizes. ** Maximum dimension.

STUD HOLE SIZE 1/4

5/16 3/8 1/2

1/2

D

L

.63 .63 .81 .81 .94 .94 1.03 1.50 1.72 1.69 1.69 3.16 3.22 3.03 3.03

1.06 1.16 1.50 1.47 2.00 2.00 2.25 2.81 3.19 3.38 3.38 5.50 4.69 4.75 4.75

Fig. 4

DIMENSIONS ** N W E .25 .31 .44 .47 .50 .50 .88 .88 .78 .88 .88 .63 .63 .63 .63

.50 .50 .63 .63 1.00 1.00 1.13 1.51 1.50 1.75 1.75 1.25 1.50 1.75 1.75

— — — — — — — — — — — 1.75 1.75 1.75 1.75

T

** H

RECOMMENDED TIGHTENING ▲ TORQUE in-lb

.09 .10 .19 .19 .25 .25 .25 .31 .44 .50 .50 .38 .44 .50 .50

.50 .55 .80 .80 1.13 1.12 1.25 1.58 1.56 1.94 1.94 1.50 1.57 1.94 1.94

45 50 50 120 275 275 375 500 500 500 600 375 500 500 600

BURNDY®

Products

Mechanical TYPES K3A-U, KK3A-U UNIVERSAL TERMINAL A-26

(Three Conductor) For Aluminum and Copper Conductors Fig. 1

Dual-rated three-conductor lugs are constructed from high strength aluminum alloy and electro tin-plated to provide low contact resistance.

Fig. 2

AL9CU

Fig. 3

CATALOG NUMBER* K3A2U-2* K3A25U-2* K3A26U-2N K3A27U-2N K3A29U-2N K3A31U-2N K3A36U-2N KK3A36U-2N KK3A40U-2N KK3A44U-2N

FIG. NO.

WIRE RANGE ALUMINUM OR COPPER

1 1 3 3 3 3 3 2 2 2

Three: 14 STR. - 2 STR. Three: 14 STR. - 1/0 STR. Three: 14 STR. - 2/0 STR. Three: 6 STR. - 3/0 STR. Three: 6 STR. - 250 Three: 6 STR. - 350 Three: 2 STR. - 600 Three: 2 STR. - 600 Three: 300 - 800 Three: 500 - 1000

* Slotted screw. ** ‘‘N” indicates NEMA standard stud holes. ▲ Listed torque values are for maximum conductor sizes accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor sizes. All 4N items See note page A-2

K

STUD HOLE SIZE

11/32 7/16

5/16 3/8

9/16

1/2

D

L

1.63 2.09 3.06 3.00 3.00 3.00 3.22 3.00 3.03 3.34

2.19 2.91 3.75 3.88 4.00 4.31 4.69 5.63 5.69 6.19

DIMENSIONS N W E

T

H

.34 .34 .63 .63 .63 .63 .63 .56 .63 .63

.19 .25 .19 .31 .31 .31 .44 .44 .50 .56

.62 .88 1.79 1.12 1.19 1.38 1.56 1.69 1.94 1.88

1.59 1.94 1.95 2.81 2.81 3.00 3.63 4.22 4.81 4.75

.88 1.00

1.75

RECOMMENDED TIGHTENING ▲ TORQUE in-lb 50

275

375

BURNDY®

Products

Mechanical TYPE BGBL LAY-IN QIKLUG™ A-15

*UL LISTED 90° C, 600 V The Lay-In QIKLUG™, Type BGBL is manufactured from high strength 6061-T6 aluminum, and is ideally suited for grounding and bonding applications accommodating both copper and aluminum conductor sizes #14 AWG to 250 kcmil.

Fig. 1

Features and Benefits • * UL 486B listed, AL9CU rated. 9 For copper and aluminum conductor combinations up to 90° C, 600 Volt applications. • UL Recognized for grounding and bonding. 9 Ensures reliability. • Electro-tin plated. 9 Provides low contact resistance. • Lay-in feature. 9 Eases installation.

Fig. 2

DIMENSIONS CATALOG NUMBER

FIG NO.

CONDUCTOR RANGE

1

4 - 14 AWG

BGBL-1/0

1

1/0 - 14 AWG

BGBL-250

2

250 kcmil - 6

*BGBL-4

C

D

E

H REF

.39 [10] .63 [16] .88 [22]

.62 [16] .80 [20] 1.18 [30]

.48 [12] .83 [21] 1.00 [30]

.79 [20] 1.16 [29] 1.72 [44]

J 1/4 - 28 3/8 - 24 7/16 - 18

NOTE: PEN-A PENETROX® inhibitor is recommended for all aluminum terminations.

TYPE CL50-1 COPPER LAY-IN QIKLUG™ FOR COPPER The Lay-In QIKLUG™ is manufactured from high strength pure electrolytic copper to ensure maximum strength and conductivity. UL467 Listed for direct burial in earth or concrete. The open-faced design allows for fast lay-in of the conductor without the need for cutting or breaking.

CATALOG NUMBER CL50-1

WIRE RANGE COPPER

STUD HOLE

#14 - #4 CU

#10

K DIA.

L

N

T

.22 [6] .28 [7] .28 [7]

1.10 [28] 1.63 [41] 2.18 [55]

.20 [5] .44 [11] .45 [11]

.13 [3] .19 [5] .25 [6]

HEX SIZE SLOT SLOT 7/32

BURNDY® Products

Grounding Mechanical

TYPE GC-A DUAL RATED GROUND CLAMP For Copper and Aluminum Cable E-40

GC-A ground clamps are UL Listed for use with either copper or aluminum conductors to copper water pipe, galvanized pipe or steel conduit. All clamps are constructed from tin plated high-strength extruded aluminum alloy. PENETROX™ oxide inhibiting joint compounds are recommended for all aluminum applications.

Features and Benefits • Clamps are dual rated for both copper and aluminum conductors. 〫 Maximum flexibility of application. • All connectors are tin plated. 〫 Provide low contact resistance and prevents galvanic corrosion. • All clamps are range taking. 〫 Only 3 catalog numbers covers complete range of applications from 1/2 - 4 inches.

Catalog Number

Conduit, Pipe, or Water Tube Size

Wire Range

Screw Type

W

L

Hex Size

GC15A GC18A GC22A

1/2 - 3/4 - 1 1-1/4 - 1-1/2 - 2 2-1/2 - 3 - 3-1/2 - 4

1/0 - 14 250 kcmil - 6 250 kcmil - 6

Slotted Hex Socket Hex Socket

11/16 13/16 1

2-1/4 3-3/4 6-5/16

S 5/16 5/16

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products. Canada: 1-800-387-6487

www.burndy.com

US: 1-800-346-4175

BURNDY®

Products

Mechanical TYPES KS & KS-3 SERVIT® A-4

For Copper, Copperweld Compact, high strength, high copper alloy SERVIT® split-bolt has free-running threads and easy to grip wrench flats. Highly resistant to season cracking and corrosion, the SERVIT® provides maximum pressure and assures a secure connection on all combinations of run and tap conductors. Type KS-3 accommodates 3 maximum size conductors.

CONDUCTOR COPPER CATALOG NUMBER KS90 **KS15 **KS17 * KS17-3 **KS20 * KS20-3 **KS22 * KS22-3 **KS23 **KS25 **KS26 **KS27 **KS29 **KS31 **KS34 KS39 KS44

CROSS FLATS

L

W

.50 .50 .63

.85 .85 1.14

.38 .38 .45

.69

1.20

.51

.75

1.50

.60

.82 .94 1.05 1.36 1.36 1.70 1.82 2.31 2.56

1.54 1.77 1.94 1.86 2.07 2.51 2.79 3.29 3.73

.62 .73 .82 1.17 1.17 1.41 1.48 1.94 2.19

RANGE FOR EQUAL RUN AND TAP

SOL.

12 STR. - 10 STR. 10 STR. - 8 STR. 8 STR. - 6 SOL. 8 STR. - 6 SOL. 8 STR. - 4 SOL. 8 STR. - 4 SOL. 6 STR. - 2 SOL. 6 STR. - 2 SOL. 6 STR. - 2 STR. 4 STR. - 1/0 STR. 2 STR. - 2/0 STR. 1 STR. - 3/0 STR. 1 STR. - 250 1/0 STR. - 350 2/0 STR. - 500 4/0 STR. - 750 300 - 1000

16 STR. 14 STR. 14 STR. 16 STR. 14 STR. 14 STR. 14 STR. 14 STR. 14 STR. 14 STR. 14 STR. 8 SOL. 8 STR. 1/0 STR. 2/0 STR. 4/0 STR. 4/0 STR.

#10 #8 #6 #6 #4 #4 #2 #2 #1 2/0 3/0 — 4/0 — — — —

▲ Listed torque values are for maximum conductor combinations accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor combinations.



COPPERWELD MIN. TAP WITH MAX. RUN

MAXIMUM RUN AND TAP STR. TYPE A TYPE D — — 3 #12 3 #12 3 #10 3 #10 3 #8 3 #8 3 #7 3 #5 7 #7 — 7 #5 19 #8 19 #6 19 #5 —

— — 8A 8A 6A 6A 4A 4A 3A 2A — — — — — — —

— — 9-1/2D 9-1/2D 8D 8D 6D 6D 5D 4D — — — — — — —

RECOMMENDED TIGHTENING TORQUE in-lb 80

165

275 385 500 650 825 1000 1100

See note page A-2 * Not UL or CSA Listed ** UL Rated for direct burial.

TYPE SC SERVIT® COVER HUG-A-BUG Used indoors or outdoors, this compact, onepiece plastic SERVIT® cover saves time and material, eliminates costly taping of splitbolts. Positive latch snaps easily and quickly over connector, ideal for tight quarters. Selfpositioning plastic fingers wrap around wires fully insulating joint. UL Listed for 600 volt indoor application with type KS. Three Covers accommodate a range of 6 SERVIT® sizes through 2/0 Str.

CATALOG NUMBER SC4 SC2 SERVIT® and cover combination can be ordered as follows: CKS4 KS20 with cover CKS2/0 KS26 with cover For other combinations, please contact factory.

SC2/0

FOR USE WITH KS17, KS17-3, KS20 KSU17, KSU20 KS22, KS20-3, KS23, KS22-3, KSA6, KSA4, KSU22, KSU23 KS25, KS26, KSA2, KSA 1/0 KSU25, KSU26