HALO Commercial - Cooper Industries

Report 9 Downloads 160 Views
HALO Commercial DESCRIPTION

Type

Catalog #

Recessed 8 inch aperture open downlight for vertical 100W maximum A19, PAR20, PAR30L, PAR38 or BR40 lamp. Fixture is suitable for commercial construction. Insulation must be kept 3" from top and sides of housing. Specify housing and trim separately to complete luminaire.

Project Date

Comments Prepared by

SPECIFICATION FEATURES

MECHANICAL Frame Boat shaped galvanized steel frame with 1/2" plaster lip accommodates ceilings up to 2" thick. May be used for new construction or remodeling installations. Provided with (2) remodel clips to secure frame when installed from below the ceiling. Mounting Brackets Bar hanger receivers adjusts 2" vertically from above the ceiling or thru the aperture. Use with No Fuss™ bar hangers or with 1/2" EMT. Removable to facilitate installation from below the ceiling. No Fuss™ Bar Hangers Pre-installed and centered bar hanger locks to tee grid with a screwdriver or pliers. Centering marks on the bar hanger mechanism allows consistent positioning of fixtures.

OPTICAL Reflector Highly efficient one piece aluminum reflector provides for lamp and lamp image cutoff for a visually comfortable optic. Self flanged standard.

Lamp Socket E26 medium base porcelain socket with nickel plated brass screw shell.

Socket Cap One piece metal cap attached securely to reflector with turn and - Specular Reflectors - Polished lock mechanism. flange standard with white Insulation Detector painted flange option. Self heating insulation detector - Baffles and White Reflector - opens circuit if insulation is White painted flange improperly installed. standard. Code Compliance Trim Retention - Thermally protected and cULus Reflector is retained with two listed for damp locations. torsion springs and held tightly to - IP20 rated for open trims. the finished ceiling surface. ELECTRICAL Junction Box (6) 1/2" and (2) 3/4" trade size pry outs positioned to allow straight conduit runs. Listed for (12) #12 AWG (six in, six out) 90°C conductors and feed thru branch wiring.

PD8V120 80V Incandescent Tungsten-Halogen (IR) 100W Max A19, PAR20, PAR30L, PAR38, BR40 LEDi Integrated (Self-ballasted) 16W Max PAR38LED 11W Max PAR30LED 7W Max PAR20LED

DIMENSIONS

7W Max A19LED

9.376" [238.16mm]

8-Inch Aperture Open Downlight New Construction or Remodel

8.375" I.D. [212.73mm]

Non-IC

9.250" [234.95mm] 9.750" O.D [247.65mm]

26.400" [670.56mm]

9.472" [240.59mm]

16.181" [410.99mm]

ADV111725

December 10, 2012 10:15 AM

HALO Commercial

PD8V120 80V

ORDERING INFORMATION SAMPLE NUMBER:PD8V120 80VC O r d e r h o u s i n g , r e fl e c t o r a n d l a m p s e p a r a t e l y f o r a c o m p l e t e l u m i n a i r e .

Housing PD8V120 = 8 Inch vertical, E26, 120V PD8CPV120 = 8 Inch vertical E26, 120V CCEA listed (Chicago Plenum)

Flange Option Blank=Polished Flange (C, G, H) Blank=White flange (W, BB, WB) WF=White Flange (C, G, H)

Finish Option C=Specular Clear G=Specular Gold H=Semi Specular Clear W=White (White Flange) BB=Black Baffle (White Flange) WB=White Baffle (White Flange)

Reflector 80V = 8” vertical

Accessories HB128APK = L channel hanger bar, 26”, ‘No-Fuss’, pair (replacement) RMB22 = 22” long wood joist mounting bars H277 = 277V step down transformer, 300VA H347 = 347V step down transformer, 75VA H347200 = 347V step down transformer, 200VA

P H OTO M E T RY

PD8V120-80VC_150A21INC

Candela Distribution

Spacing Criteria = 2.00 Lumens per Watt = 14 LpW Test No. P21685_R2 Test Model: PD8V120-80VC_150A21INC Candlepower Distribution Curve 90° 80° 70° 60° 50° 40°

Candela

0*

531

5

538

45

15

628

55

10°

Distance to Illuminated Plane

Initial Nadir Footcandles

25510

5.5'

5432

7'

Avg. 0° Luminance

80° 70° 60° 50° 40° 30° 20°

24

10.1

10.1

15

12.8

12.8

8'

11

14.7

14.7

65

294

35

1228

75

132

9'

9

16.5

16.5

45

738

85

0

10'

7

18.3

18.3

55

136

12'

5

22

22

65

6

14'

4

25.6

25.6

75

2

85

0

90

0

Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. Footcandle values are initial, apply appropriate light loss factors where necessary.

Zonal Lumen Summary

Candela Distribution

90°

W

Width

925

20°

Candlepower Distribution Curve

Beam (ft.) L

Length

Zone

Spacing Criteria = 0.38 Lumens per Watt = 45 LpW Test No. P21679 Test Model: PD8V120-80VC_16PAR38LED

10°

Degree

*CBCP

PD8V120-80VC_16PAR38LED



(Average Candela/M2)

25

30° 0°

Cone of Light Footcandles

Luminance

Degrees Vertical

Degrees Vertical

Candela

0*

2959

Lumens

% Lamp

% Fixture

0-30

670.43

24.10

31.60

0-40

1409.39

50.70

66.40

0-60

2108.76

75.90

99.30

0-90

2123.29

76.40

100.00

Luminance

Cone of Light Footcandles

(Average Candela/M2) Degree

Avg. 0° Luminance

Distance to Illuminated Plane

Initial Nadir Footcandles

Beam (ft.) L

W

Length

Width

5

2536

45

1694

5.5'

98

2.1

2.1

15

914

55

639

7'

60

2.6

2.6

25

231

65

0

8'

46

3

3

35

66

75

0

9'

37

3.4

3.4

45

49

85

0

10'

30

3.8

3.8

55

16

12'

21

4.5

4.5

65

0

14'

15

5.3

5.3

75

0

85

0

90

0

Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. Footcandle values are initial, apply appropriate light loss factors where necessary.

Zonal Lumen Summary

*CBCP Zone

Lumens

% Lamp

% Fixture

0-30

585.39

N.A.

85.20

0-40

629.88

N.A.

91.70

0-60

686.41

N.A.

99.90

0-90

687.01

N.A.

100.00

Note: Specifications and Dimensions subject to change without notice.

Visit our web site at www.cooperlighting.com

Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 486.4801 www.cooperlighting.com

Cooper Lighting 5925 McLaughlin Rd. Mississauga, Ontario, Canada L5R 1B8 905.507.4000 FAX 905.568.7049