HALO Commercial DESCRIPTION
Type
Catalog #
Recessed 8 inch aperture open downlight for vertical 100W maximum A19, PAR20, PAR30L, PAR38 or BR40 lamp. Fixture is suitable for commercial construction. Insulation must be kept 3" from top and sides of housing. Specify housing and trim separately to complete luminaire.
Project Date
Comments Prepared by
SPECIFICATION FEATURES
MECHANICAL Frame Boat shaped galvanized steel frame with 1/2" plaster lip accommodates ceilings up to 2" thick. May be used for new construction or remodeling installations. Provided with (2) remodel clips to secure frame when installed from below the ceiling. Mounting Brackets Bar hanger receivers adjusts 2" vertically from above the ceiling or thru the aperture. Use with No Fuss™ bar hangers or with 1/2" EMT. Removable to facilitate installation from below the ceiling. No Fuss™ Bar Hangers Pre-installed and centered bar hanger locks to tee grid with a screwdriver or pliers. Centering marks on the bar hanger mechanism allows consistent positioning of fixtures.
OPTICAL Reflector Highly efficient one piece aluminum reflector provides for lamp and lamp image cutoff for a visually comfortable optic. Self flanged standard.
Lamp Socket E26 medium base porcelain socket with nickel plated brass screw shell.
Socket Cap One piece metal cap attached securely to reflector with turn and - Specular Reflectors - Polished lock mechanism. flange standard with white Insulation Detector painted flange option. Self heating insulation detector - Baffles and White Reflector - opens circuit if insulation is White painted flange improperly installed. standard. Code Compliance Trim Retention - Thermally protected and cULus Reflector is retained with two listed for damp locations. torsion springs and held tightly to - IP20 rated for open trims. the finished ceiling surface. ELECTRICAL Junction Box (6) 1/2" and (2) 3/4" trade size pry outs positioned to allow straight conduit runs. Listed for (12) #12 AWG (six in, six out) 90°C conductors and feed thru branch wiring.
PD8V120 80V Incandescent Tungsten-Halogen (IR) 100W Max A19, PAR20, PAR30L, PAR38, BR40 LEDi Integrated (Self-ballasted) 16W Max PAR38LED 11W Max PAR30LED 7W Max PAR20LED
DIMENSIONS
7W Max A19LED
9.376" [238.16mm]
8-Inch Aperture Open Downlight New Construction or Remodel
8.375" I.D. [212.73mm]
Non-IC
9.250" [234.95mm] 9.750" O.D [247.65mm]
26.400" [670.56mm]
9.472" [240.59mm]
16.181" [410.99mm]
ADV111725
December 10, 2012 10:15 AM
HALO Commercial
PD8V120 80V
ORDERING INFORMATION SAMPLE NUMBER:PD8V120 80VC O r d e r h o u s i n g , r e fl e c t o r a n d l a m p s e p a r a t e l y f o r a c o m p l e t e l u m i n a i r e .
Housing PD8V120 = 8 Inch vertical, E26, 120V PD8CPV120 = 8 Inch vertical E26, 120V CCEA listed (Chicago Plenum)
Flange Option Blank=Polished Flange (C, G, H) Blank=White flange (W, BB, WB) WF=White Flange (C, G, H)
Finish Option C=Specular Clear G=Specular Gold H=Semi Specular Clear W=White (White Flange) BB=Black Baffle (White Flange) WB=White Baffle (White Flange)
Reflector 80V = 8” vertical
Accessories HB128APK = L channel hanger bar, 26”, ‘No-Fuss’, pair (replacement) RMB22 = 22” long wood joist mounting bars H277 = 277V step down transformer, 300VA H347 = 347V step down transformer, 75VA H347200 = 347V step down transformer, 200VA
P H OTO M E T RY
PD8V120-80VC_150A21INC
Candela Distribution
Spacing Criteria = 2.00 Lumens per Watt = 14 LpW Test No. P21685_R2 Test Model: PD8V120-80VC_150A21INC Candlepower Distribution Curve 90° 80° 70° 60° 50° 40°
Candela
0*
531
5
538
45
15
628
55
10°
Distance to Illuminated Plane
Initial Nadir Footcandles
25510
5.5'
5432
7'
Avg. 0° Luminance
80° 70° 60° 50° 40° 30° 20°
24
10.1
10.1
15
12.8
12.8
8'
11
14.7
14.7
65
294
35
1228
75
132
9'
9
16.5
16.5
45
738
85
0
10'
7
18.3
18.3
55
136
12'
5
22
22
65
6
14'
4
25.6
25.6
75
2
85
0
90
0
Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. Footcandle values are initial, apply appropriate light loss factors where necessary.
Zonal Lumen Summary
Candela Distribution
90°
W
Width
925
20°
Candlepower Distribution Curve
Beam (ft.) L
Length
Zone
Spacing Criteria = 0.38 Lumens per Watt = 45 LpW Test No. P21679 Test Model: PD8V120-80VC_16PAR38LED
10°
Degree
*CBCP
PD8V120-80VC_16PAR38LED
0°
(Average Candela/M2)
25
30° 0°
Cone of Light Footcandles
Luminance
Degrees Vertical
Degrees Vertical
Candela
0*
2959
Lumens
% Lamp
% Fixture
0-30
670.43
24.10
31.60
0-40
1409.39
50.70
66.40
0-60
2108.76
75.90
99.30
0-90
2123.29
76.40
100.00
Luminance
Cone of Light Footcandles
(Average Candela/M2) Degree
Avg. 0° Luminance
Distance to Illuminated Plane
Initial Nadir Footcandles
Beam (ft.) L
W
Length
Width
5
2536
45
1694
5.5'
98
2.1
2.1
15
914
55
639
7'
60
2.6
2.6
25
231
65
0
8'
46
3
3
35
66
75
0
9'
37
3.4
3.4
45
49
85
0
10'
30
3.8
3.8
55
16
12'
21
4.5
4.5
65
0
14'
15
5.3
5.3
75
0
85
0
90
0
Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. Footcandle values are initial, apply appropriate light loss factors where necessary.
Zonal Lumen Summary
*CBCP Zone
Lumens
% Lamp
% Fixture
0-30
585.39
N.A.
85.20
0-40
629.88
N.A.
91.70
0-60
686.41
N.A.
99.90
0-90
687.01
N.A.
100.00
Note: Specifications and Dimensions subject to change without notice.
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 486.4801 www.cooperlighting.com