HALO Commercial DESCRIPTION
Type
Catalog #
Recessed 6-inch LED shallow lens downlight retrofit is available in various distributions, lumen and CRI/CCT options. Installs from below the ceiling into existing open frame recessed housings. Insulation must be kept 3” from top and sides of housing. Use for general area lighting where high efficiency and visual comfort are required.
Project Date
Comments Prepared by
SPECIFICATION FEATURES
MECHANICAL Frame Use to retrofit existing Halo Commercial PD6 series incandescent, compact fluorescent or metal halide recessed housings to LED. Cooper Lighting Halo Commercial • PD6H Series • PD6V Series • PD6P Series OPTICAL LED Module Proximity phosphors over chip on board LEDs provide a uniform source with high efficiency and no pixilation. Available in 80 or 90 CRI minimum, accuracy within 3 SDCM provides color uniformity. See ordering information for available CRI / CCT options. Passive thermal management achieves L70 at 50,000 hours in non IC applications. Integral diffuse lens provides visual shielding. Integral connector allows quick connection to housing flex. B e a m F o rm i n g O p t i c s Optional beam forming optics replace diffuse lens and provide narrow flood or flood distribution for long throws of light.
Reflector One piece parabolic aluminum reflector combines high optical efficiency with visual comfort. Attaches to LED module with (3) speed clamps minimizing light leaks to lens. Self-flanged standard with an optional white painted flange.
Compliance - cULus classified for wet location - cCSAus classified for wet location
Trim Retention Reflectors are retained with two torsion springs holding the flange tightly to the finished ceiling surface.
- Airtight per ASTM-E283.
ELECTRICAL Module Flex Armored cable assembly attaches to junction box and provides tool-less connection to the LED module. D ri v e r Integral UNV 120 - 277V 50/60 Hz constant current driver provides noise free operation. For 347V input use Halo transformer H347 or H347200. Continuous, flicker-free dimming from 100% to 10% with leading or trailing edge phase cut at 120V or 0 -10V analog control. Mounted to a junction box cover to replace existing. Emergency Option Provides 90 minutes of standby lighting meeting most life safety codes for egress lighting. Available with remote charge indicator and test switch.
- IP66 Ingress Protection Rated - Insulation must be kept 3” from top and sides.
PD6RX12 PD6RX18
- Optional City of Chicago environmental air (CCEA) marking for plenum applications.
PDM6
- EMI/RFI emissions per FCC 47CFR Part 18 non-consumer limits.
64V
- Contains no mercury or lead and RoHS compliant.
1,200 & 1,800
- Photometric testing in accordance with IES LM-79-08.
Lumen Series
- Lumen maintenance projections in accordance with IES LM-80-08 and TM-21-11.
LED RETROFIT
- Can be used to comply with California Title 24 NonResidential Lighting Controls requirements as a LED Luminaire. - ENERGY STAR® listed for commercial applications, reference database for current listings.
6-Inch Aperture Lens Downlight
Lumens
1200 Series
Input Voltage
120V
277V
Input Current
0.19A
0.1A
Input Power Efficiency Inrush Current Lumens
23 W
23.2 W
79 LpW
79 LpW
2.14A
4.1A
1800 Series
Input Voltage
120V
277V
Input Current
0.24A
0.12A
Input Power
29.5 W
29.4 W
Efficiency
75 LpW
75 LpW
2.88A
6.94A
Inrush Current THD: ≤ 20% PF: ≥ 0.90
T Ambient -30 - +40°C Sound Rating ≤ 22dba
AHC131428 9/18/2014
HALO Commercial
PD6RX12/PD6RX18 PDM6 64V
OR DERING INFORMATI O N SAMPLE NUMBER: PD6RX12ED010REM-PDM6827-64VC A complete luminaire consists of a housing, LED module and reflector, order separately.
Housing
Lumens
Driver
Options
PD6RX = 6” aperture LED downlight retrofit, less mounting frame PD6RXCP = 6” aperture LED downlight retrofit, less mounting frame, CCEA listed for City of Chicago plenum requirements
12 = 1,200 lumens (nominal) 18 = 1,800 lumens (nominal)
ED010 = 120-277V 50/60Hz, 0-10V and LE/TE phase cut dimming
REM = Emergency operation with remote indicator and test switch (not available with PD6RXCP housing), 60 Hz
LED Module
CRI/CCT
PDM6 = Downlight LED module for PD6 housing, provides 1,200 or 1,800 lumens (nominal) depending on connected housing type
827 = 80 CRI, 2700K CCT 927 = 90 CRI, 2700K CCT 830 = 80 CRI, 3000K CCT 930 = 90 CRI, 3000K CCT 835 = 80 CRI, 3500K CCT 935 = 90 CRI, 3500K CCT 840 = 80 CRI, 4000K CCT 940 = 90 CRI, 4000K CCT
Reflector
Finish Option
Flange Option
Accessories
64V = 6" shallow parabolic reflector
C = Specular clear G = Specular gold H = Semi-specular clear W = White (white flange)
Blank = Polished flange standard with C, G, & H reflector finishes Blank = White flange standard with W WF = White flange option available with C, G, & H reflector finishes
BFR56NFL = Beam forming reflector kit, narrow flood distribution BFR56FL = Beam forming reflector kit, flood distribution BFR56MH = Media holder, accepts one 3.45” lens L345SF = 3.45” diameter soft focus lens H347 = Step down transformer for 347V input, 75VA max H347200 = Step down transformer for 347V input, 200VA max
D I ME NSIONS
5" [ 127 mm]
6" [ 155 mm] ID 7.25" [ 184 mm] 7.75" [ 197 mm] OD
HALO Commercial
PD6RX12/PD6RX18 PDM6 64V
C O MP L IANCE TABLE 1200 LUMEN 80 CRI Catalog #
PD6RX12ED010 - PDM6827 PD6RX12ED010 - PDM6830 PD6RX12ED010 - PDM6835 PD6RX12ED010 - PDM6840 Lumens
LPW
Lumens
LPW
Lumens
LPW
Lumens
LPW
64VC
1654
72
1720
75
1780
77
1811
79
64VCWF
1649
72
1715
75
1775
77
1805
78
64VG
1628
71
1693
74
1752
76
1782
77
64VGWF
1612
70
1676
73
1734
75
1765
77
64VH
1606
70
1670
73
1728
75
1758
76
64VHWF
1596
69
1660
72
1717
75
1747
76
64VW
1648
72
1714
75
1774
77
1804
78
90 CRI Catalog #
PD6RX12ED010 - PDM6927 PD6RX12ED010 - PDM6930 PD6RX12ED010 - PDM6935 PD6RX12ED010 - PDM6940 Lumens
LPW
Lumens
LPW
Lumens
LPW
Lumens
LPW
64VC
1283
56
1379
60
1493
65
1492
65
64VCWF
1279
56
1375
60
1488
65
1488
65
64VG
1263
55
1357
59
1469
64
1469
64
64VGWF
1251
54
1344
58
1455
63
1454
63
64VH
1246
54
1339
58
1449
63
1449
63
64VHWF
1238
54
1331
58
1440
63
1439
63
64VW
1279
56
1374
60
1488
65
1487
65
1800 LUMEN 80 CRI Catalog #
PD618ED010 - PDM6827
PD618ED010 - PDM6830
PD618ED010 - PDM6835
PD618ED010 - PDM6840
Lumens
LPW
Lumens
LPW
Lumens
LPW
Lumens
LPW
64VC
2009
68
2096
71
2174
74
2213
75
64VCWF
2003
68
2089
71
2168
73
2206
75
64VG
1977
67
2062
70
2140
73
2178
74
64VGWF
1958
66
2042
69
2119
72
2156
73
64VH
1950
66
2034
69
2111
72
2148
73
64VHWF
1938
66
2022
69
2097
71
2135
72
64VW
2002
68
2088
71
2166
73
2205
75
90 CRI Catalog #
PD618ED010 - PDM6927
PD618ED010 - PDM6930
PD618ED010 - PDM6935
PD618ED010 - PDM6940
Lumens
LPW
Lumens
LPW
Lumens
LPW
Lumens
LPW
64VC
1567
53
1684
57
1817
62
1841
62
64VCWF
1562
53
1678
57
1812
61
1835
62
64VG
1542
52
1657
56
1789
61
1812
61
64VGWF
1527
52
1641
56
1771
60
1794
61
64VH
1521
52
1634
55
1764
60
1787
61
64VHWF
1512
51
1624
55
1753
59
1776
60
64VW
1561
53
1677
57
1811
61
1834
62
ES, T24
ES = ENERGY STAR® Qualified T24 = Can be used to comply with California Title 24 Non-Residential
HALO Commercial
PD6RX12/PD6RX18 PDM6 64V
P H O T OMETRY PD6RX12ED010- PDM6835-64VC
Candela Distribution
Spacing Criteria = 0.93 Lumens per Watt = 77.4 LpW Test No. P114170 Test Model: PD6RX12ED010- PDM6835-64VC Candlepower Distribution
Eyeball at 0-degrees 90º
75º
450 60º
900
Degrees Vertical
Candela
0*
1289
Luminance
Cone of Light Footcandles
(Average Candela/M2) Degree
Avg. 0° Luminance
Distance to Illuminated Plane
Initial Nadir Footcandles
W
Width
5
1277
45
32383
5.5'
42.6
5
5
1122
55
19966
7'
26.3
6.4
6.4
25
864
65
6603
8'
20.1
7.4
7.4
35
608
75
0
9'
15.9
8.2
8.2
45
418
85
0
10'
12.9
9.2
9.2
55
209
12'
9
11
11
65
51
75
0
85
0
90
0
Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. Footcandle values are initial, apply appropriate light loss factors where necessary.
Zonal Lumen Summary
*CBCP
1350 15º
Length
15
45º
0º
Beam (ft.) L
30º
Scaling factor for the Battery back up:
Zone
Lumens
% Fixture
0-30
829
46.6
0-40
1213
68.1
0-60
1721
96.7
0-90
1780
100
- 1800 Lumen = 0.33 - 1200 Lumen = 0.27
PD6RX12ED010- PDM6930-64VC
Candela Distribution
Spacing Criteria = 0.93 Lumens per Watt = 60 LpW Test No. P114173 Test Model: PD6RX12ED010- PDM6930-64VC Candlepower Distribution
Eyeball at 0-degrees 90º
75º
350 60º
700 45º
1050 0º
15º
30º
Scaling factor for the Battery back up: - 1800 Lumen = 0.33 - 1200 Lumen = 0.27
Degrees Vertical
Candela
0*
999
Luminance
Cone of Light Footcandles
(Average Candela/M2) Degree
Avg. 0° Luminance
Distance to Illuminated Plane
Beam (ft.)
Initial Nadir Footcandles
L
Length
W
Width
5
990
45
25096
5.5'
33
5
5
15
870
55
15464
7'
20.4
6.4
6.4
25
669
65
5111
8'
15.6
7.4
7.4
35
471
75
0
9'
12.3
8.2
8.2
45
324
85
0
10'
10
9.2
9.2
55
162
12'
6.9
11
11
65
39
75
0
85
0
90
0 *CBCP
Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. Footcandle values are initial, apply appropriate light loss factors where necessary.
Zonal Lumen Summary Zone
Lumens
% Fixture
0-30
643
46.6
0-40
940
68.1
0-60
1333
96.7
0-90
1379
100
HALO Commercial
PD6RX12/PD6RX18 PDM6 64V
P H O T OMETRY PD6RX18ED010- PDM6835-64VC
Candela Distribution
Spacing Criteria = 0.93 Lumens per Watt = 73.7 LpW Test No. P114154 Test Model: PD6RX18ED010- PDM6835-64VC Candlepower Distribution
Eyeball at 0-degrees 90º
75º
550 60º
1100
Degrees Vertical
Candela
0*
1574
Luminance
Cone of Light Footcandles
(Average Candela/M2) Degree
Avg. 0° Luminance
Distance to Illuminated Plane
Length
W
Width
5
1560
45
39554
5.5'
52
5
5
1488
55
24381
7'
32.1
6.4
6.4
25
1371
65
8055
8'
24.6
7.4
7.4
35
743
75
0
9'
19.4
8.2
8.2
45
510
85
0
10'
15.7
9.2
9.2
55
255
12'
10.9
11
11
65
62
75
0
85
0
90
0
Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. Footcandle values are initial, apply appropriate light loss factors where necessary.
Zonal Lumen Summary
*CBCP
1650 15º
L
15
45º
0º
Beam (ft.)
Initial Nadir Footcandles
30º
Scaling factor for the Battery back up:
Zone
Lumens
% Fixture
0-30
1013
46.6
0-40
1482
68.1
0-60
2102
96.7
0-90
2174
100
- 1800 Lumen = 0.33 - 1200 Lumen = 0.27
PD6RX18ED010- PDM6930-64VC
Candela Distribution
Spacing Criteria = 0.93 Lumens per Watt = 57.1 LpW Test No. P114157 Test Model: PD6RX18ED010- PDM6930-64VC Candlepower Distribution
Eyeball at 0-degrees 90º
75º
450 60º
900
Degrees Vertical
Candela
0*
1219
Luminance
Cone of Light Footcandles
(Average Candela/M2) Degree
Avg. 0° Luminance
Distance to Illuminated Plane
Initial Nadir Footcandles
W
Width
5
1208
45
30631
5.5'
40.3
5
5
1061
55
18876
7'
24.9
6.4
6.4
25
817
65
6239
8'
19
7.4
7.4
35
575
75
0
9'
15.1
8.2
8.2
45
395
85
0
10'
12.2
9.2
9.2
55
198
12'
8.5
11
11
65
48
75
0
85
0
90
0
Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. Footcandle values are initial, apply appropriate light loss factors where necessary.
Zonal Lumen Summary Zone
*CBCP
1350 15º
L
Length
15
45º
0º
Beam (ft.)
30º
Scaling factor for the Battery back up:
Lumens
% Fixture
0-30
785
46.6
0-40
1147
68.1
0-60
1628
96.7
0-90
1684
100
- 1800 Lumen = 0.33 - 1200 Lumen = 0.27
Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com
Eaton’s Cooper Lighting Business 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.cooperlighting.com
© 2014 Eaton All Rights Reserved Printed in USA Publication No. AHC131428 September 2014