Heat Pump Decorative Inverter Split Unit SDMA-HIGxxxT01 Series
I NTE G RA PRODUCT LEAFLET
nverter
Air
r
n
ner
INTE G RATE D HO ME COM FORT
D HO ME CO M FO RT
Air
r
n
ner
INTE G RATE D HO ME COM FORT
TABLE OF CONTENTS Topic
Page
1. Rheem Introduction
4-5
2. Core Technology
6
3. Nomenclature
7
4. Model Numbers
7
5. Technical Specifications
8
INT E G RAT E D
Air
r
n
ner
INTE G RATE D HO ME COM FORT
3
Founded in the USA as a steel drum manufacturer by the Rheem brothers Rheem expanded internationally to Australia, Brazil, Canada and Singapore
02
4
Air
r
n
ner Air
INTE G RATE D HO ME COM FORT
r
n
ner
INTE G RATE D HO ME CO M FO RT
complete air
25 03
Air
r
n
ner
INTE G RATE D HO ME COM FORT
5
CORE TECHNOLOGY Standard Features
Self-diagnosis Once abnormal operation or part failure occurs, the unit will automatically shutoff to protect the system. Meanwhile, it will indicate protection or error code for diagnosis.
Dehumidifying Dehumidifies the room efficiently.
Vertical Auto Swing For a more efficient air and temperaS ture distribution throughout the room, air discharge flaps can automatically Intelligent Defrost move vertically Usually, traditional defrosting works by setting a time interval. For instance, a 10 minute defrosting process is initiated Turbo after every 50 minute interval. Press the "Turbo" button on the Turbo remote controller to enjoy better air Intelligent Defrosting is only performed flow. This enables the indoor temperawhen required, which reduces the ture to reach the set temp in a shorter energy wastage. period of time. Defrosting
Defrosting
Defrosting
Defrosting
LED Display Beautiful LED display for an attractive look.
Heating
(60mins)
Heating
(8mins)
(70mins)
Heating
(5mins)
Intelligent Defrost
(70mins)
Heating
(50mins)
Heating
(10mins)
(50mins)
Heating
(10mins)
(50mins)
Traditional Defrosting
Low Voltage Startup Cold Plasma Unit is safely able to start start even when the voltage is below standard. Odor removal kills 90% of bacteria. Furthermore, air nutrition is improved Sleep Mode with more negative oxygen ions. While the unit is in cooling, energysaving or dry mode, the sleep mode activates: a. After an hour, the set Timer Automatically turns the air conditemperature increases by 1°C (2°F). tioner ON or OFF automatically b. After 2 hours, the set temperature within a 24-hour period. increases by another 1°C (2°F). Hence, the set temperature will totally increase by 2°C (4°F) in 2 hours and Auto Restart then the unit will continue to operate at In case of power shutdown, this this temperature. feature allows for automatic restart V
Low
with the previous settings when Cold Air Draft Prevention power resumes. The heat exchanger is heated in advance to avoid a cold air draft.
6
Air
r
n
ner
INTE G RATE D HO ME COM FORT
SDMA-HIG Series
NOMENCLATURE System: S
D
M
A
H
I
G
009
T
01
INTERNAL REVISION CODE
220-240V / 50HZ / 1PH
CAPACITY
SOURCE CODE
INVERTER
HEATPUMP
R410A WALL MOUNT
DUCT FREE
RHEEM
MODEL NUMBERS Model 9000 12000 18000 24000
System Model Nos. SDMA-HIG009T01 SDMA-HIG012T01 SDMA-HIG018T01 SDMA-HIG024T01
Air
r
n
ner
INTE G RATE D HO ME COM FORT
SDMA-HIG Series
7
TECHNICAL SPECIFICATIONS Parameter Power Supply
Unit
SDMA-HIG009T01
SDMA-HIG012T01
SDMA-HIG018T01 SDMA-HIG024T01
Rated Voltage
V
Rated Frequency
Hz
50
Phases
--
Single
Power Supply Mode
220-240
--
Outdoor
Rated Cooling Capacity**
Btu/h
8530
10920
15700
20820
Rated Heating Capacity***
Btu/h
9550
12180
17850
21160
Rated Cooling Power Input**
W
780
997
1430
2000
Rated Heating Power Input***
W
775
942
1380
1900
Cooling Current
A
3.60
4.50
6.34
9.35
Heating Current
A
3.50
4.40
6.12
10.00
EER
(Btu/h)/w
10.94
10.95
10.98
10.41
COP
(Btu/h)/w
12.32
12.31
12.32
11.13
SEER
--
6.10
6.10
6.10
6.50
SCOP(Average)
--
4.00
4.00
4.00
4.00
SCOP(Warmer)
--
5.10
5.10
5.10
4.60
SCOP(Colder)
--
Energy Class
--
3.30 A++ Cooling / A+ Average /
3.30 A++ Cooling / A+ Average /
3.30 A++ Cooling / A+ Average /
3.20 A++ Cooling / A+ Average /
A+++ Warmer /
A+++ Warmer /
A+++ Warmer /
A+++ Warmer /
B(Colder) 790×275×200
B(Colder) 790×275×200
B(Colder) 970×300×224
B(Colder) 970×300×224
9.0
9.0
13.5
13.5
Indoor Unit Outdoor Unit
Dimension (W×H×D) Net Weight Compressor Type
mm --
Rotary
Dimension (W×H×D)
mm
776×540×320
842×596×320
842×596×320
955×700×396
Net Weight
kg
25.5
29.0
31.5
46.0
Refrigerant
--
R410A
** (I) Entering Air D.B.T / Air W.B.T: 27 °C / 19 °C, (O) Entering Air D.B.T: 35 °C *** (I) Entering Air D.B.T: 20 °C, (O) Entering Air D.B.T / W.B.T: 7 °C / 6 °C
INTEG 8
Air
r
n
ner
INTE G RATE D HO ME COM FORT
SDMA-HIG Series
Notes
RAT E D HO M
Notes
E CO M FOR
Notes
Why Rheem?
For continuous product improvement, Rheem reserves the right to make changes to the product specifications without notice.
SDMA-HIG - 2016-08
American Brand with Global Reach, Dedicated to Quality & Innovation