Holiday Inn & Express King Georg

Report 20 Downloads 97 Views
"We're Your Indoor Comfort Experts" www.iceheatingandcooling.com

Project Name:

Holiday Inn & Express King George

Date:

June 28, 2016

General Contractor:

MB Contractors, Inc. 5001 W. Village Green Drive, Suite 205 Midlothian, VA 23112

Subcontractor:

I.C.E. Heating & Cooling, LLC 451 Central Road, Suite C Fredericksburg, VA 22401

Manufacturer:

Markel

Supplier:

Hoffman & Hoffman (Richmond) 2104 W. Laburnum Ave. Ste.102 Richmond, VA 23227

Specification Section:

Electric Wall Heaters

Please Note: We have reviewed the submittal; it is Complete, and in our opinion it meets the contract requirements. Review will not include correctness of details, proper configuration, utility connections, dimensions, sizes, quantities and the like. ICE Heating and Cooling Name: Patti Mohr-PMA

451-C Central Rd, Fredericksburg, VA 22401 Tele 540-654-5518 Fax 540-368-9767

Submittal

Holiday Inn King George Contents: Heaters by Markel

June 28, 2016 Contractor: I.C.E. Heating & Cooling Engineer: Consolidated Engineers

Submitted by: Hoffman & Hoffman (Richmond, VA) Salesman: Steve Seay

SUBMITTAL DATA

for

APPROVAL REQUIRED

HOFFMAN

HOFFMAN, INC.

HVAC Manufacturers Representative Website: www.hoffman-hoffman.com Asheville, NC Charlotte, NC Raleigh, NC Wilmington, NC Chattanooga, TN Knoxville, TN

Charleston, SC (843) 884-3201 (828) 296-0111 Columbia, SC (803) 765-9360 (704) 364-4700 Greenville, SC (864) 676-1888 (919) 781-8011 Chesapeake, VA (757) 548-1700 (910) 791-4775 Richmond, VA (804) 272-1500 (423) 693-2890 Roanoke, VA (540) 725-8701 (865) 540-9770 Corporate: Greensboro, NC (336) 292-8777

We have exercised care in the preparation of this submittal. We believe it satisfies our interpretation of the designer’s intent and scope. It contains the list of materials, quantities, sizes, style and the finish as we propose to furnish for this job. Please examine and check carefully that all items are exactly as required and that our interpretation of the applicable plans and/or specifications are consistent with the design. Approval by the engineer and purchaser will be required before release of this equipment for production. If any discrepancies are discovered, please notify us as soon as possible.

Tag: ECH-1, ECH-2

COMMERCIAL FAN-FORCED WALL HEATERS

FRA SERIES CONTEMPORARY DESIGN • Commercial grade steel grille designed to provide comfort through optimized airflow

UNIFORM DISTRIBUTION OF WARMTH • Built-in fan delay switch energizes fan motor only after elements are heated, which prevents discharge of unheated air • Fan only operation for summer use • Integral double pole thermostat allows for easy adjustment of room temperature to maintain desired comfort level

SAFETY STANDARDS COMPLIANT • Safety Listed by Intertek (ETL) for use in the USA and Canada complying with ANSI/UL2021 and C22.2, NO. 56 Safety Standards

APPLICATIONS: Attics Basements Entryways Large Rooms Offices

• Manual reset thermal overheat protector disconnects power in the event of overheating due to accidental blockage

DURABILITY AND EASY MAINTENANCE • All units have a permanently lubricated totally enclosed fan motor, which creates long life and low maintenance, and gently distributes warmth throughout the area • Built-in power disconnect switch for added safety during maintenance

Remodels ZBL-BFRAO

|

9-14

www.berkomep.com

PRODUCT SUBMITTAL SHEET Capacities

FRA SERIES FAN-FORCED WALL HEATERS

1500, 1800, 2000, 3000, 3600 4000 or 4800 Watts 120, 208, 240, 277, 347 or 600V 1 or 3 Phase Thermostat Range: 40° - 90° F Air Movement: 100 CFM

Holiday Inn Job Name: _________________________________________________________________ King George, VA Location: __________________________________________________________________

Submitted By:

Date:

6/28/2016

Hoffman & Hoffman

Architect:__________________________________________________________________

Consolidated Engineers Engineer: __________________________________________________________________ Approved By:

Date:

ICE Heating & Cooling Contractor: ________________________________________________________________ Hoffman & Hoffman Submitted By: ______________________________________________________________ 6/28/2016 Date: _____________________________________________________________________ Catalog Number

Item

QTY

Tag

Watts

A

9

FRA4020F

ECH-1

4000

B

2

FRA4020F

ECH-2

2000

Volts

PH

AMPS

208

1

19.2

208

1

9.6

Weight

ACCESSORIES Item

QTY

470 Beauty Spot Road East Bennettsville, South Carolina 29512 www.marleymep.com

Part Number

Tag

ZSS-BFRAO | 9-2015

Catalog Number Volts FRA1512F FRA1812F FRA4024F FRA4027F FRA3027F FRA4020F FRA40203F FRA40243F FRA4824F FRA4827F FRA4820F FRA48203F FRA48243F FRA3203F FRA3206F FRA3153F FRA3156F FRA3303F FRA3306F FRA3403F FRA3406F FRA3503F FRA3506F

Amps

Watts

12.5 1500 120 15.0 120 1800 240/208 16.7/8.3 - 14.5/7.2 4000/2000 - 3000/1500 277/240 16.7/8.3 - 14.5/7.2 4000/2000 - 3000/1500 10.8/5.4 3000/1500 277 19.2/9.6 4000/2000 208 11.1 208 4000 9.7 240 4000 20/17.3 4800/3600 240/208 20/17.3 4800/3600 277/240 23.1 208 4800 13.4 208 4800 11.6 4800 240 5.8 2000 347 600 3.3 2000 4.3 347 1500 2.5 600 1500 8.6 3000 347 5 3000 600 11.5 347 4000 6.7 4000 600 13.8 4800 347 600 8 4800

Phase

BTU/HR

1 1 1 1 1 1 3 3 1 1 1 3 3 1 1 1 1 1 1 1 1 1 1

5115 6138 13,640/6820 - 10,230/5115 13,640/6820 - 10,230/5115 10230/5115 13,640/6820 13,640 13,640 16375/12280 16375/12280 16,375 16,375 16,375 6820 6820 5115 5115 10,230 10,230 13,640 13,640 16,375 16,375

Accessories FRASM FRAS1 FRAS2 VFKSFCNW FRAFCTPF

Surface mounting frame for surface installations - Northern White 1” deep surface mounting frame for semi-recessed installation - Northern White 2” deep surface mounting frame for semi-recessed installation - Northern White 14 gauge security front cover - Northern White Tamper proof front cover - Northern White

ARCHITECT’S AND ENGINEER’S SPECIFICATIONS* The heating equipment shall include an electric automatic fan forced air heater suitable for area heating, as manufactured by Berko®, a Marley Engineered Products® Brand, Bennettsville, SC. The heater shall be designed for wall mounting, recess or surface. Heaters shall be cETLus listed. BACK BOX: The back box shall be designed as a recessed rough-in box in either masonry or frame installations and is also used when surface mounting frames are used in surface mounting installations. The back box shall be heavy gauge galvanized steel and shall contain knockouts through which power leads enter. INNER FRAME ASSEMBLY: The heater assembly, which fits into the back box, shall consist of a heavy gauge steel fan panel to which all of the operational parts of the heater are mounted. The inner frame assembly shall be completely prewired. HEATING ELEMENT: The heating element shall be of the non-glowing design consisting of an 80/20 nickel-chromium resistance wire enclosed in a steel sheath to which plate fins are copper brazed. The element shall cover the entire air discharge area to ensure uniform heating of all discharged air. It shall be warrantied for 5 years. ON/OFF SWITCH: A double-pole, single throw on/off switch shall be mounted on the back box for positive disconnect of power supply. It will be completely concealed behind the front cover.

MOTOR AND CONTROLS: The fan motor shall be totally enclosed, impedance protected, permanently lubricated and with a totally enclosed rotor. Fan control shall be of the bimetallic, snap-action type and shall activate fan after heating element reaches operating temperature, and continue to operate the fan after the thermostat is satisfied and until all heated air has been discharged. The thermostat shall be single-pole type on all models. Thermal cutout shall be bimetallic, snap-action type designed to shut off heat in the event of overheating. The fan shall be five-bladed aluminum. SURFACE MOUNTING FRAME: The surface mounting frame shall be of heavy gauge steel designed to mount around the back box for a finished surface installation. Slot knock outs shall be provided for power supply conduit. FRONT COVER: The louvered front cover shall be of heavy gauge steel with a powder paint finish. A plug button will be provided to replace the thermostat knob and render the unit tamper-resistant. FINISH: All sheet metal parts, except the galvanized steel back box, shall be phosphatized, then completely painted by a powder paint process. *In the interest of continual improvements in product and performance, Marley Engineered Products reserves the right to change specifications without notice.

ZSS-BFRAO | 9-2015

Tag: ECH-3

QFF Ceiling Mounted Fan-Forced Heaters Berko’s high-capacity, heavy-duty fan-forced ceiling heaters are designed for use in commercial, industrial or institutional applications requiring electric fan forced heaters. They perform exceptionally well in such applications as entry ways, hallways, restrooms, stores, detention environments and similar large areas. These heaters will accommodate pneumatic/electric or low voltage controls commonly used with computerized energy management systems. The 1/4 inch mesh screen deters insertion of foreign objects.

u VERY VERSATILE - INSTITUTIONAL, COMMERCIAL AND INDUSTRIAL u HEAT OUTPUT - 1500 - 4800W u  MULTIPLE MOUNTING OPTIONS - RECESSED, SURFACE, OR T-BAR u  BUILT IN THERMAL OUTLET & FAN DELAY u  IDEAL FOR HIGH HEAT-LOSS AREAS



– 14-GAUGE FRONT LOUVER GRILLE – 150 CFM – DOUBLE-POLE SINGLE THROW DISCONNECT – TEMPERATURE IS CONTROLLED BY REMOTE WALL OR BUILT-IN THERMOSTAT

www.berkomep.com

QFF SERIES

HEAVY DUTY CEILING MOUNTED HEATERS

470 Beauty Spot Road East Bennettsville, SC 29512

CAPACITIES 1500 TO 4800W 120V, 208V, 240V, 277V, & 480V See Selection Chart Note: 480volt heaters are 3 phase only.

Holiday Inn

JOB NAME: LOCATION:

King George, VA

ARCHITECT: ENGINEER:

Consolidated Engineers

CONTRACTOR:

ICE Heating & Cooling

SUBMITTED BY: Hoffman & Hoffman DATE: 6/28/2016

ITEM

QTY.

CATALOG NUMBER

TAG

C

1

QFF4804

ECH-3

WATTS

VOLTS

3600

208

PHASE AMPS

1

17.3

ACCESSORIES & CONTROLS ITEM

QTY.

C

1

ZSS-BQFFO

CATALOG NUMBER

QFFT2

TAG

DESCRIPTION

ECH-3

Double Pole Thermostat

(03-12)

www.berkomep.com

QFF SERIES - HEAVY DUTY CEILING MOUNTED HEATERS

SUBMITTAL SHEET

CATALOG NUMBER QFF1500 QFF3007 QFF4008 QFF4004

470 Beauty Spot Road East Bennettsville, SC 29512

DIMENSIONS 2-1/2”

TOP VIEW 3-3/4” 2-1/2”

FRONT VIEW RECESSED BOX

1-5/16”

14-3/8” 1-5/8”

18-3/4”

S I D E

QFF4007 QFF4804 QFF4807 QFF48483 QFF48483LV**

VOLTS 120 277 208 240 208 277 240 240/208 277/240 480 480

WATTS* 1500 3000 4000/2000 4000/2000 3000/1500 4000/2000 3000/1500 4800/3600 4800/3600 4800 4800

BTU/HR. 5120 10239 13,652/6,826 13,652/10,239 10,239/5,120 13,652/10,239 10,239/5,120 16,382/12,287 16,382/12,287 16,382 16,382

SHIP WT. AMPS PHASE (LBS.) 12.5 1 10.8 1 19.2/9.8 1 16.7/14.4 1 14.4/7.2 14.4/12.5 1 23 12.5/6.2 20.0/17.3 1 20.0/17. 73 17.3/15.0 1 5.8 3 5.8 3

* Factory wired at higher wattage. ** Includes 24V Control Relay.

V I E W

ACCESSORIES & CONTROLS 15-3/8”

1”

S I D E

FRONT COVER (Louvers Not Shown) 18-3/4”

QFF SERIES

SELECTION CHART

V I E W

CATALOG NUMBER QFFSM QFFR2 (24V) QFFR12 (120V) QFFTBF QFFT1 QFFT2 QFFTR4 QFFTR7

DESCRIPTION Surface Mounting Frame Low Voltage Time Delay Relay, 45-60 seconds to close when energized. Uses remote 24V or 120V power source. T-Bar Frame Kit. Single Pole Thermostat. (Field Installed) Installed)) Double Pole Thermostat. (Field ( 208/240V Primary Transformer 24V Relay. 277V Primary 24V Secondary. Transformer Relay.

SHIP WT. (LBS.) 2 2 1 1 3 1 1

ARCHITECT’S & ENGINEER’S SPECIFICATIONS** The heating equipment shall include a ceiling mounted QFF electric automatic fan-forced heater suitable for large area heating as manufactured by Berko, A Marley Engineered Products Brand, Bennettsville, SC. The heater shall be designed for ceiling surface, recess or T-Bar mounting. Heaters shall be UL Listed. HEATER ASSEMBLY: The heater assembly, which fits in the back box, shall consist of a fan panel upon which is mounted all of the operational parts of the heater. HEATING ELEMENT: The heating element shall be of the non-glowing design consisting of 80/20 NiCh resistance wire enclosed in a steel sheath to which plate fins are copper brazed. It shall be warranted for 5 years. FAN AND FAN MOTOR: The fan shall be five-bladed aluminum. The fan motor shall be totally enclosed. FAN DELAY SWITCH: Fan control shall be of bi-metallic, snap-action type and shall activate fan after heating element reaches operating temperature. The fan shall continue to operate after the thermostat is satisfied and until the heating element is cool. THERMAL CUTOUT: A thermal cutout shall be built into the system to shut off the heater in the event of overheating. DISCONNECT SWITCH: A double-pole single throw disconnect switch shall be mounted on the back box for positive disconnect of power supply. It will be com-

pletely concealed behind the face-plate. BACK BOX: The back box shall be designed for duty as a recessed rough-in box either masonry or frame installations, and is also used with the surface mounting frame in surface mounting installations. The back box shall be 20-gauge galvanized steel and shall contain knockouts through which power leads are brought. FACEPLATE: The louvered faceplate shall be of 14 gauge cold-rolled steel, phosphatized, then electrostatically painted Navajo White by a powder coat process. A 1/4-inch mesh screen shall be installed beneath the faceplate to deter the insertion of foreign objects. The face plate shall be secured to the heating unit with tamper-resistant screws. THREE-PIECE DESIGN: The heater shall be made up of a back box, a heater assembly and a faceplate. OPTIONS: THERMOSTAT: The optional tamperresistant thermostat shall be of the bi-metallic, snap-action type with enclosed contacts. It shall be completely concealed behind the faceplate to become tamperresistant (QFFT1 or QFFT2). LOW VOLTAGE TIME DELAY RELAYS: 24 volt and 120 volt low voltage time delay relays are available as optional equipment to control 208, 240 or 277 volt heaters (with an external supplied 24 or 120 volt control circuit) in conjunction with central

energy control systems. The built-in thermostat can then be used as one of the thermostats in an automatic night set back operation. (QFFR2 or QFFR12) LOW VOLTAGE TRANSFORMER/RELAYS: (Primary or Secondary) Transformer/Relays shall be available as optional equipment to control 208, 240 or 277 volt heaters (with single point supply connection and internal supplied 24 volt control circuit) in conjunction with central energy control systems. The built-in thermostat can then be used as one of the thermostats in an automatic night set back operation. (QFFTR4 OR QFFTR7) SURFACE MOUNTING FRAME: The surface mounting frame, designed to allow full surface mounting, shall be of 14 gauge cold-rolled steel, phosphatized, then electrostatically painted by a powder coat process.(QFFSM) T-BAR FRAME: For T-Bar mounting, a 14 gauge cold-rolled steel frame, phosphatized and electrostatically painted by a powder coat process, shall be available. Frame shall be designed to mount in a standard 2’ x 2’ ceiling grid.(QFFTBF) **Berko reserves the right to change specifications without prior notice.

Recommend Documents