Home Comfort FRA106HT2

Through-The-Wall Air Conditioner  Product Dimensions Height 14-1/2" Width 24" Depth 20-1/2"

More Easy-To-Use Features Energy and Cost Savings

The unit operates at a low voltage – conserving energy and saving you money.

Multi-Speed Fan

Features three different fan speeds, for more cooling flexibility.

Sleep Mode

Quiet operation keeps you cool without keeping you awake. Plus, Sleep Mode gradually increases room temperature after being activated.

Quickly Cools

Quickly cool a room on hot days.

Comfort Control Design

Easily control the direction of your cool air, wherever your unit is.

Effortless™ Restart

Automatically resumes operating at its previous settings when power is restored to your unit.

Clean Filter Alert

Notifies you when your filter needs to be cleaned.

Power Cord

Comes with an extra long three-prong cord that makes extension cords unnecessary.

Signature Features Effortless™ Remote Temperature Control A thermostat located on your air conditioner’s remote control precisely maintains preset room temperature, so you will remain comfortable at all times.

Ready-Select® Controls

24-Hour On/Off Timer

Keep things cool on your schedule.

Easily select options with the touch of a button. ENERGY STAR®

Remote Control

Effortless™ Clean Filter

Allows you to precisely control the temperature and fan speed from across the room.

Our antibacterial filter reduces bacteria, room odors and other airborne particles for a cool, comfortable environment.

Performance

BTUs

Cool

10,000 / 9,800

frigidaire.com

Home Comfort FRA106HT2

Through-The-Wall Air Conditioner

Performance BTU (Cool)

10,000 / 9,800

Dehumidification (Pints / Hour)

2.8

Cool Area (Sq. Ft.)

500

Energy Efficiency Ratio

9.4

Electrical Volts

230 / 208

Amps (Cool)

5.1 / 5.3

Watts (Cool)

1,060 / 1,045

Length of Power Cord

6'

Plug Type (NEMA)

LCDI (6-15P)

Features

RAC Through-The-Wall Models (18" Sleeve Kit EA Frigidaire Baseline

Electronic Controls

Ready-Select® Controls

Fan Speeds (Cool / Fan)

3 / 3

Low Voltage Start-Up

Yes

Auto Cool Function

Yes

Energy Save

Yes

Sleep Mode

Yes

Filter Check

Yes

24-Hour On / Off Timer

Yes

A

B

C D

Clean Air Ionizer Remote Control

Full-Function Remote T’Stat

Air CFM (High / Med / Low)

292 / 267 / 243

Air Direction Control

4-Way

Fresh Air / Exhaust Vent / Closed

No / No / Yes

Filter Type

Antibacterial Mesh

Filter Access

Slide-Out

Slide-Out Chassis Warranty1

Yes

Optional Accessories Through-The-Wall 18" Sleeve Kit

PN # EA108T

Trim Kit (for larger existing sleeve)

PN # EA120T

Architectural-Style Exterior Louvered Grille

PN # EA109T

Certifications ENERGY STAR®

Yes

Performance

AHAM

Specifications Refrigerant

R410a

Shipping Weight (Approx.)

77 Lbs.

Warranty 5 year sealed system / 1 year full parts and labor.

1

Plug Type (NEMA) 6-15P

NOTE: For planning purposes only. Always consult local and national electric codes. Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com.

Product Dimensions

Sleeve Cutout Dimensions

A - Height

14-1/2"

Height

15-5/8"

B - Width

24"

Width

25-15/16"

C - Depth

20-1/2"

D - Max. Wall Thickness

18"

Accessories information available on the web at frigidaire.com

USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-800-FRIGIDAIRE • frigidaire.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca FRA106HT2 01/13

© 2013 Electrolux Home Products, Inc.

Specifications subject to change.

Frigidaire Baseline

Home Comfort FRA106HT2

Through-The-Wall Air Conditioner

Plug Type (NEMA) 6-15P

Home Comfort Specifications

Replacement Installation

• Product Shipping Weight (approx.) – 77 Lbs. • Single phase 3-wire cable, 230 / 208 Volt, 60 Hertz AC only electrical

• When replacing existing air conditioner with new unit, refer to

supply with ground required on separate circuit fused on both sides of line. • Amps @ 230 / 208 Volts = 5.1 / 5.3 Amps • Recommended Circuit Breaker – 15 Amps • Unit equipped with 230 / 208V 3-wire power supply cord, NEMA plug type 6-15P, approximately 72" long. • Unit’s increased performance characteristics result from two rear intakes. For unit to operate at maximum efficiency, carefully follow complete, detailed new or replacement installation instructions provided in Product Installation Guide on web. • Unit requires rearward slope when installation is complete, to allow condensate to drain from rear of sleeve.

New Installation • For new installation, Frigidaire® Through-The-Wall 18" Sleeve Kit

PN # EA108T available. Recommended for proper installation.

• Through-the-wall installation requires 18" maximum wall thickness. • For energy-saving purposes, install unit in shady location, preferably

a northern exposure; and do not block airflow inside with blinds, curtains or furniture; or outside with shrubs, enclosures or other buildings.

Product Installation Guide on web to identify existing wall-sleeve manufacturer and size compatibility. If proper installation and slope are suspect, then correct installation of Frigidaire® Through-The-Wall 18" Sleeve Kit PN # EA108T recommended. • Use of existing wall sleeve to mount new unit requires original sleeve be in sound structural condition with rear grille that attaches securely, or rear flange that serves as stop for unit. • Preferable installation option, for increased efficiency and possibility of drafts reduced, requires existing rear grille (mounted to sleeve) be replaced with new unit’s rear air-directional louvered grille (provided in accessory kit, shipped with unit). Non-preferable installation option of directly mounting rear louvered grille to unit can be considered, requiring grille be mounted to unit prior to sleeve installation. • Existing decorative exterior grille may be left in place, provided that proper air-directional rear louvered grille is installed. • For installation into larger existing sleeve, optional Trim Kit PN # EA120T available. Note: For planning purposes only. Refer to Product Installation Guide on the web at frigidaire.com for detailed instructions.

Optional Accessories • Through-The-Wall 18" Sleeve Kit – (PN # EA108T). • Trim Kit (for larger existing sleeve) – (PN # EA120T). • Architectural-Style Exterior Louvered Grille – (PN # EA109T).

USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-800-FRIGIDAIRE • frigidaire.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca FRA106HT2 01/13

© 2013 Electrolux Home Products, Inc.

Specifications subject to change.