Home Comfort FRA106HT2
Through-The-Wall Air Conditioner Product Dimensions Height 14-1/2" Width 24" Depth 20-1/2"
More Easy-To-Use Features Energy and Cost Savings
The unit operates at a low voltage – conserving energy and saving you money.
Multi-Speed Fan
Features three different fan speeds, for more cooling flexibility.
Sleep Mode
Quiet operation keeps you cool without keeping you awake. Plus, Sleep Mode gradually increases room temperature after being activated.
Quickly Cools
Quickly cool a room on hot days.
Comfort Control Design
Easily control the direction of your cool air, wherever your unit is.
Effortless™ Restart
Automatically resumes operating at its previous settings when power is restored to your unit.
Clean Filter Alert
Notifies you when your filter needs to be cleaned.
Power Cord
Comes with an extra long three-prong cord that makes extension cords unnecessary.
Signature Features Effortless™ Remote Temperature Control A thermostat located on your air conditioner’s remote control precisely maintains preset room temperature, so you will remain comfortable at all times.
Ready-Select® Controls
24-Hour On/Off Timer
Keep things cool on your schedule.
Easily select options with the touch of a button. ENERGY STAR®
Remote Control
Effortless™ Clean Filter
Allows you to precisely control the temperature and fan speed from across the room.
Our antibacterial filter reduces bacteria, room odors and other airborne particles for a cool, comfortable environment.
Performance
BTUs
Cool
10,000 / 9,800
frigidaire.com
Home Comfort FRA106HT2
Through-The-Wall Air Conditioner
Performance BTU (Cool)
10,000 / 9,800
Dehumidification (Pints / Hour)
2.8
Cool Area (Sq. Ft.)
500
Energy Efficiency Ratio
9.4
Electrical Volts
230 / 208
Amps (Cool)
5.1 / 5.3
Watts (Cool)
1,060 / 1,045
Length of Power Cord
6'
Plug Type (NEMA)
LCDI (6-15P)
Features
RAC Through-The-Wall Models (18" Sleeve Kit EA Frigidaire Baseline
Electronic Controls
Ready-Select® Controls
Fan Speeds (Cool / Fan)
3 / 3
Low Voltage Start-Up
Yes
Auto Cool Function
Yes
Energy Save
Yes
Sleep Mode
Yes
Filter Check
Yes
24-Hour On / Off Timer
Yes
A
B
C D
Clean Air Ionizer Remote Control
Full-Function Remote T’Stat
Air CFM (High / Med / Low)
292 / 267 / 243
Air Direction Control
4-Way
Fresh Air / Exhaust Vent / Closed
No / No / Yes
Filter Type
Antibacterial Mesh
Filter Access
Slide-Out
Slide-Out Chassis Warranty1
Yes
Optional Accessories Through-The-Wall 18" Sleeve Kit
PN # EA108T
Trim Kit (for larger existing sleeve)
PN # EA120T
Architectural-Style Exterior Louvered Grille
PN # EA109T
Certifications ENERGY STAR®
Yes
Performance
AHAM
Specifications Refrigerant
R410a
Shipping Weight (Approx.)
77 Lbs.
Warranty 5 year sealed system / 1 year full parts and labor.
1
Plug Type (NEMA) 6-15P
NOTE: For planning purposes only. Always consult local and national electric codes. Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com.
Product Dimensions
Sleeve Cutout Dimensions
A - Height
14-1/2"
Height
15-5/8"
B - Width
24"
Width
25-15/16"
C - Depth
20-1/2"
D - Max. Wall Thickness
18"
Accessories information available on the web at frigidaire.com
USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-800-FRIGIDAIRE • frigidaire.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca FRA106HT2 01/13
© 2013 Electrolux Home Products, Inc.
Specifications subject to change.
Frigidaire Baseline
Home Comfort FRA106HT2
Through-The-Wall Air Conditioner
Plug Type (NEMA) 6-15P
Home Comfort Specifications
Replacement Installation
• Product Shipping Weight (approx.) – 77 Lbs. • Single phase 3-wire cable, 230 / 208 Volt, 60 Hertz AC only electrical
• When replacing existing air conditioner with new unit, refer to
supply with ground required on separate circuit fused on both sides of line. • Amps @ 230 / 208 Volts = 5.1 / 5.3 Amps • Recommended Circuit Breaker – 15 Amps • Unit equipped with 230 / 208V 3-wire power supply cord, NEMA plug type 6-15P, approximately 72" long. • Unit’s increased performance characteristics result from two rear intakes. For unit to operate at maximum efficiency, carefully follow complete, detailed new or replacement installation instructions provided in Product Installation Guide on web. • Unit requires rearward slope when installation is complete, to allow condensate to drain from rear of sleeve.
New Installation • For new installation, Frigidaire® Through-The-Wall 18" Sleeve Kit
PN # EA108T available. Recommended for proper installation.
• Through-the-wall installation requires 18" maximum wall thickness. • For energy-saving purposes, install unit in shady location, preferably
a northern exposure; and do not block airflow inside with blinds, curtains or furniture; or outside with shrubs, enclosures or other buildings.
Product Installation Guide on web to identify existing wall-sleeve manufacturer and size compatibility. If proper installation and slope are suspect, then correct installation of Frigidaire® Through-The-Wall 18" Sleeve Kit PN # EA108T recommended. • Use of existing wall sleeve to mount new unit requires original sleeve be in sound structural condition with rear grille that attaches securely, or rear flange that serves as stop for unit. • Preferable installation option, for increased efficiency and possibility of drafts reduced, requires existing rear grille (mounted to sleeve) be replaced with new unit’s rear air-directional louvered grille (provided in accessory kit, shipped with unit). Non-preferable installation option of directly mounting rear louvered grille to unit can be considered, requiring grille be mounted to unit prior to sleeve installation. • Existing decorative exterior grille may be left in place, provided that proper air-directional rear louvered grille is installed. • For installation into larger existing sleeve, optional Trim Kit PN # EA120T available. Note: For planning purposes only. Refer to Product Installation Guide on the web at frigidaire.com for detailed instructions.
Optional Accessories • Through-The-Wall 18" Sleeve Kit – (PN # EA108T). • Trim Kit (for larger existing sleeve) – (PN # EA120T). • Architectural-Style Exterior Louvered Grille – (PN # EA109T).
USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-800-FRIGIDAIRE • frigidaire.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca FRA106HT2 01/13
© 2013 Electrolux Home Products, Inc.
Specifications subject to change.