HPL Rakshak MCBs Catalogue

Report 4 Downloads 124 Views
ISO 9001-2008

I

O

C 63

240/41

5V

6000 3

IS/IEC 60

CM/L-8

898-1

515376

BENEFITS Close Overload Protection Short Circuit Protection Consistent Performance Finger Touch Proof

CM/L-8515376 50 Hz

IS/IEC 60898-1

CM/L-8515376

Mfd. By HPL Electric & Power Pvt. Ltd. Jabli (H.P.) 200803

IS/IEC 60898-1

I

O

CM/L-8515376 50 Hz

Mfd. By HPL Electric & Power Pvt. Ltd. Jabli (H.P.) 200803

IS/IEC 60898-1

Breaking Capacity

Miniature Circuit Breakers IS/IEC 60898-1

Certified by BIS as per IS/IEC 60898 - 1

C 63

240/41

5V

CM/L-8515376

Rakshak Miniature Circuit Breaker is a reliable device to protect electrical circuits from over currents. Rakshak MCB's are designed to provide safe protection both to user and the electrical equipment against over loads and short circuits. The superior current limiting technology limits the flow of let through energy and helps rapid extinguish of Arc, thus saving wires, cables & equipment from damage.

IS/IEC 6089

6000 3

6KA

8-1

CM/L-8

515376

I

C 63

O

415V

6000 3

Certified to IS/IEC 60898-1 Designed for mounting in any regular Distribution Boards Easy Mounting on DIN Rail Sleek, Light, flame retardant body

Mfd. By HPL Electric & Power Pvt. Ltd. Jabli (H.P.) 200803

IS/IEC 60898-1

CM/L-8515376 50 Hz

FEATURES

1 3

IS/IEC 6089

TECHNICAL DATA

8-1

CM/L-85

15376

2 4

CHARACTERISTICS OF TIME - CURRENT CURVES

DP

Current Rating : 6, 10, 16, 20, 25, 32, 40, 50 & 63 Amps. 1P, 1P+N, 2P, 3P, 3P+N, 4P. Voltage Rating : 240/415V AC 50 Hz Low watt loss hence energy saving

IS/IEC 60898-1

O

C 63

415V

IS/IEC 6089

6000 3

8-1

50 Hz

CM/L-8515376

IS/IEC 60898-1

I

Mfd. By HPL Electric & Power Pvt. Ltd. Jabli (H.P.) 200803

BREAKING CAPACITY 6KA (6000 Amps.)

TRIPPING CHARACTERISTICS B Curve Protection against Over Currents for sensitive devices The Magnetic Trip units operate between 3-5 In Example : Computers, Electrical equipments etc.

1 3 5

CM/L-85

15376

2 4 6

TP

O

C 63

415V

6000 3

IS/IEC 60898

-1

1 3 5 7

Mfd. By HPL Electric & Power Pvt. Ltd. Jabli (H.P.) 200803

I

CM/L-8515376 50 Hz

IS/IEC 60898-1

C Curve The Magnetic Trip units operate between 5-10 In Protection against Over Currents for inductive load applications Example : Airconditioners, Motor pumpsets etc.

TEMPERATURE WORKING RANGE o

o

-5 C to + 55 C

WATTLOSS CHART Rating

Wattloss (watts)

06 < In < 10

0.80

10 < In < 16

2.05

16 < In < 25

2.70

25 < In < 32

3.60

32 < In < 40

4.20

40 < In < 63

5.80

CONNECTIONS

CM/L-8515

2 4 6 8

TP+N

3P+N

Also available in HPL Rakshak Range

Isolator upto 100 Amps. Wide range and variety of Distribution Boards (Systems).

Terminal Capacity : 1 - 25mm 2

HPTPL/RAKSHAK MCB-Cat/1111

376