Effective Date: AprilJuly 1, 2011 Effective Date: 1, 2014 Revised Date: June 1, 20, 20112015 Revised Date: March
Humidifiers Dealer Parts List Model Humidifiers Model400/400M 400/400M Humidifiers
16A 16B
MODEL 400
NO. BLUE/GRAY UNITS - PART NAME 4B Base (blue/gray)
5B Cover (blue/gray) 13B Automatic Digital Humidifier Control 16B Name Plate (blue/gray) 17B Hole Plug (blue/gray)
18B Resistor Case & Manual Mode Label
NO. ALMOND UNITS - PART NAME 4A Base (almond)
5A Cover (almond) 13A Automatic Humidifier Control 16A Name Plate (almond) 17A Hole Plug (almond)
18A Resistor Case & Manual Mode Label NO. COMMON PARTS 1 Water Panel Evaporator 2 Scale Control Insert w/Float Chamber 3 Water Distribution Tray
6 Water Level Sensor Assembly 7 Water Solenoid Valve (24 Volt) 8 In-line Strainer 9 Saddle Valve 10 Orifice (Yellow) 11 Feed Tube with Strainer, Orifice, Compression Sleeve and Nut 12 Transformer 15 Damper Assembly 19 Float Assembly 20 Float Cover 24 Automatic Humidifier Control Gasket OTHER 13C Manual Humidifier Control
Outdoor Temperature Sensor Current Sensing Relay Saddle Valve Adapter Shock Arrestor Maintenance Kits (includes parts 45 (2),4004, 4403, 4406, 4407, 4335 and 4231)
Blower Activation Relay
QTY/CTN
1 1 1 1 1 1
MODEL 400M
PART NO. 4734 4728 60 4880 4741 4737
PART NO.
4734 4728 N/A 4880 4741 N/A
QTY/CTN PART NO. 1 4404 1 4329 1 56 1 4409 4408 1 1 4336
QTY/CTN PART NO. 10 (5-2 pks.) 45 4403 6 4407 1 4410 1 1 4040 12 4004 1 4001 4231 144 (12-12 pks.) 1 4335 1 4010 1 4332 1 4406 1 4405
4305 1 QTY/CTN PART NO. 1 N/A 8052 1 1 50 4229 6 4280 1
PART NO. N/A N/A N/A N/A N/A N/A
PART NO. 45 4403 4407 4410 4040 4004 4001 4231 4335 4010 4332 4406 4405
N/A PART NO. 4655 N/A 50 4229 4280
MODEL 400
1 10
4788 4851
MODEL 400M
4788 4851
Model 500/500M & 600/600M Humidifiers
16A 16B
NO. 4B 5B 13B 16B 17B 18B NO. 4A 5A 13A 16A 17A 18A
BLUE/GRAY UNITS - PART NAME Base (Blue/Gray) Cover (Blue/Gray) Automatic Digital Humidity Control Name Plate (Blue/Gray) Hole Plug (Blue/Gray) Resistor Case & Manual Mode Label
ALMOND UNITS - PART NAME Base (Almond) Cover (Almond) Automatic Humidifier Control Name Plate (Almond) Hole Plug (Almond) Resistor Case & Manual Label COMMON PARTS Water Panel® Evaporator 1 2 Scale Control Insert 3 Water Distribution Tray 6 Drain Spud 7 Water Solenoid Valve (24 Volt) 8 In-Line Strainer 9 Saddle Valve 10 Orifice (Yellow) 11 Feed Tube with Strainer, Orifice, Compression Sleeve and Nut 12 Transformer 14 Automatic Humidifier Control Gasket 15 Damper Assembly 16 Name Plate OTHER PARTS 13C Manual Humidifier Control Outdoor Temperature Sensor (only available for automatic units) Current Sensing Relay Saddle Valve Adapter Shock Arrestor Maintenance Kits (includes parts 10, 4335, 4231, 4004, 4640, 4331 and 4223) Maintenance Kits (includes parts 35, 4335, 4231, 4004, 4330, 4331 and 4223) Blower Activation Relay *Obsolete replaced by 4730
QTY/CTN 1 1 1 1 1 1 QTY/CTN 1 1 1 1 1 QTY/CTN 10 (4640-10) (4330-8) 1 6 1 12 1 144 (12-12 pks.) 1 1 1 1 1 QTY/CTN 1 1 1 6 1 1 1 10
MODEL 500, 500A & 500M
MODEL 600, 600A & 600M
PART NO. 4730 4727 60 4881 4733 N/A
PART NO. 4731 4728 60 4882 4733 4737
MODEL 500, 500A & 500M
MODEL 600, 600A & 600M
PART NO. 4641* 4642 56 4643 Obsolete 4336 PART NO. 10 4640 4331 4223 4040 4004 4001 4231 4335 4010 N/A 4332 4643 PART NO. 4655 8052 50 4229 4280 4792 N/A 4851
PART NO. 4328 4329 56 4333 4336 PART NO. 35 4330 4331 4223 4040 4004 4001 4231 4335 4010 4305 4332 4333 PART NO. 4655 8052 50 4229 4280 N/A 4839 4851
Model 700/700M, 768, 760A & 760 Humidifiers
BLUE/GRAY UNITS PART NAME Automatic Digital Humidifier Control Transformer Motor (Blue/Gray) Cover (Blue/Gray) Base (Blue/Gray) Orifice Plate (Blue/Gray) Bridge Resistor Case & Manual Mode Label Female Disconnect Assembly Relay ALMOND UNITS NO. PART NAME 2A Automatic Humidifier Control 16A Motor (Almond) 17A Cover (Almond) 18A Base (Almond) 19A Orifice Plate (Almond) 20A Bridge 21A Resistor Case & Manual Mode Label 22A Female Disconnect Assembly 23A Circuit Board 24 Automatic Humidifier Control Gasket NO. COMMON PARTS Water Panel® Evaporator 1 3 Saddle Valve 4 In-line Strainer 6 Cork Isolator 7 Water Solenoid Valve (24 Volts) 8 Orifice (Blue) 9 Feed Tube with Strainer, Orifice, Compression Sleeve and Nut 10 Scale Control Insert 11 Male Disconnect Assembly 12 Water Distribution Tray 13 Fan Blade 14 Electrical Grommet 15 Power Cord (Blue/Gray) 25 Name Plate Assembly OTHER PARTS 2C Manual Humidifier Control Outdoor Temperature Sensor (only available for automatic units) Current Sensing Relay Saddle Valve Adapter Shock Arrestor Maintenance Kits (includes parts 35 (2), 4236, 4235, 4246, 4232 and 4004) Blower Activation Relay *Obsolete replaced with 4732 **Obsolete replaced with 4735 ***Obsolete replaced with 4736 NO. 2B 5 16B 17B 18B 19B 20B 21B 22B 23B
QTY/CTN 1 1 1 1 1 1 1 1 1 1 QTY/CTN 1 1 1 1 1 1 1 1 1 1 QTY/CTN 10 1 12 6 1 144 (12-12 pks.) 1 12 1 1 1 1 1 1 QTY/CTN 1 1 1 6 1 1 10
MODEL 700
MODEL 700M
PART NO. 60 4010 4670 4729 4732 4735 4736 4737 4739 4740
PART NO. N/A 4010 4670 4729 4732 4735 4736 N/A 4739 4740
MODEL 700
MODEL 700, 768, 760A, 760
PART NO. N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A PART NO. 35 4001 4004 4031 4040 4232 4235 4236 4240 4246 4247 4249 4664 4968 PART NO. N/A 8052 50 4229 4280 4750 4851
PART NO. 56 4237 4242 4245* 4244** 4243*** 4336 4239 4238 4305 PART NO. 35 4001 4004 4031 4040 4232 4235 4236 4240 4246 4247 4249 4664 4968 PART NO. 4655 8052 50 4229 4280 4750 4851
Model 800/865 Residential Steam Humidifiers (Release Date Before November 2014) 9 6
7A
11A
4
7B
11B
21
7C
8
5
1 2 15
3A 3B
17
3C
16 20 22
10 13 12 19A 19B 14 18
24
23
25
90-1698
Model 800/865 Residential Steam Humidifiers (Release Date Before November 2014) NO.
PART NAME
QTY/CTN PART NO.
1
Fill Valve In-line Strainer
12
4004
2
Membrane Switch
1
4975
3A
Transformer, 120/24 VAC for 11.5 amp unit* & fill valve contained within housing
1
4976
3B
Transformer, Universal for Model 865 with fill valve inlet extending from bottom of housing (75 VA)
1
5306
New!
3C
Transformer, Universal for Model 800 with fill valve inlet extending from bottom of housing (40 VA)
1
5529
New!
4
Power Relay
1
4977
5
Electrode Wire
1
4978
6
Ground Lug
1
4979
7A
Input Power Terminal Block 3-post for 11.5 amp unit* and fill valve contained within housing
1
4980
7B
Input Power Terminal Block 2-post for 11.5 amp unit* and fill valve inlet extending from bottom of housing
1
5307
7C
Input Power Terminal Block 2-post for 11.5/16.0 amp unit*
1
5354
8
Internal Control Circuit Board
1
4981
9
Current Sensing Circuit Board
1
4982
10
Drain Valve
1
4983
11A
Inlet Fill Valve and Water Feed System for unit with fill valve contained within housing
1
4984
11B
Inlet Fill Valve and Water Feed System for unit with fill valve inlet extending from bottom of housing
1
5309
12
Drain Cup Assembly
1
4985
13
Front Panel and Screw
1
4986
14
Electrical Access Panel and Screw
1
4987
15
Safety Interlock Switch
1
4988
16
Fill Cup and Hoses
1
4989
17
Fill Cup Cap
1
4990
18
Steam Dispersion Tube and Screws
1
4991
19A
Automatic Digital Control
1
62
19B
Digital Manual Control (Wall Mounted)
1
65
20
Steam Canister and O-Ring
6
80
21
Transformer terminal block for unit with fill valve inlet extending from bottom of housing.
1
5308
22
O-Ring for Steam Canister
6
5258
23
Condensate Tubing with Wire Ties
1
4997
24
Grille
1
4998
25
Fan
1
4999
Saddle Valve
1
4001
Drain Trap Assembly
1
4028
Manual Humidistat and Blower Activation Relay
1
4993
Airflow Proving Switch
1
4592
1
4594
Condensate Pump (Rated for 160 F)
1
4856
Steam Hose (6ft) and Clamps
1
4973
Drain Hose (10 ft.) and Clamps
1
4974
1
5405
OTHER PARTS
High Humidity Limit Switch 0
Dispersion Tube Mounting Bracket for 8" Round Hi-Velocity Duct * See data label on side of humidifier to determine if unit draws 11.5 amps or 11.5/16.0 amps.
New!
Model 800/801/865/866 Residential Steam Humidifiers (Release Date of Model 800/865 after November 2014) 6 17 22
4 1 2
18
10
3 12
11 14
5 8 7 15 16 9
23A 23B
13
20
19
21
90-1961
Model 800/801/865/866 Residential Steam Humidifiers (Release Date of Model 800/865 after November 2014) NO.
PART NAME
QTY/CTN
PART NO.
1
Fill Valve In-line Strainer
12
4004
2
Membrane Switch
1
5532
New!
3
Transformer, Universal for Model 865, 866 (75 VA)
1
5306
New!
4
Electrode Wire
1
4978
5
Drain Valve
1
4983
6
Inlet Fill Valve, Water Feed Tube and Clamps
1
5531
7
Drain Cup Assembly
1
4985
8
Front Panel and Screw
1
4986
9
Electrical Access Panel and Screw
1
4987
10
Safety Interlock Switch
1
4988
11
Fill Cup and Hoses
1
5590
12
Fill Cup Cap
1
4990
13
Steam Dispersion Tube and Screws
1
4991
14
Steam Canister and O-Ring
6
80
15
Automatic digital Control for Model 800
1
62
16
Digital Manual Humidistat (Wall Mounted)
1
65
17
Control Board, Model 800, 865
1
5530
18
Universal Transformer, Model 800, 801 (40 VA)
1
5529
19
Condensate Tubing with Wire Ties
1
4997
20
Grille
1
4998
21
Fan
1
4999
22
Modulating Control board, Model 801, 866
1
5554
23A
Automatic Digital Modulating control (ADMC) for Model 801
1
63
23B
Automatic Digital Modulating control (ADMC) for Model 866
1
5558
OTHER PARTS Saddle Valve
1
4001
Drain Trap Assembly
1
4028
Airflow Proving Switch
1
4592
High Humidity Limit Switch
1
4594
1
4851
Condensate Pump (Rated for 160 F)
1
4856
Steam Hose (6ft) and Clamps
1
4973
Drain Hose (10 ft.) and Clamps
1
4974
Duct Sensor, Used with Model 63 Only
1
5559
New!
Dispersion Tube Mounting Bracket for 8" Round Hi-Velocity Duct
1
5405
New!
Relay, ADHC 0
New!
New!
Model 350 Humidifiers NO. PART NAME
QTY/CTN
PART NO.
Inlet Frame Almond
1
4206
Inlet Frame Gray
1
4852
2
Scale Control Insert
12
4181
3
Water Panel® Evaporator
10
35
4
Distribution Tray
1
4182
5
Distribution Tray Cover
1
4183
6
Nozzle
1
4184
7
Baffle
1
4185
Housing Almond
1
4186
Housing Gray
1
4858
Drain Spud
1
4187
10 Fan Blade
1
4188
11
1
4189
1 Set
4190
1
4191
1
8 9
Motor
12 Motor Brackets 13 Solenoid Valve (Plastic Junction Box) 14 Orifice (Blue)
144 (12-12 pks.)
4232
15 120 Volt Humidifier Control - Replaces 4013
1
4258
16 Feed Tube with Strainer, Orifice, Compression Sleeve and Nut
1
4079
17 Junction Box Cover
1
4193
18 Junction Box
1
4194
19 Humidistat
1
4655
20 In-Line Strainer
12
4004
21 Power Cord
1
4286
22 Saddle Valve
1
4001
Angle Support Almond
2
4813
Angle Support Gray
2
4875
Outlet Transition Almond
1
4201
Outlet Transition Gray
1
4854
Joist Bracket Almond
2
4202
Joist Bracket Gray
2
4874
Screws and Clips Almond
1
4203
Screws and Clips Gray
1
4850
Saddle Valve Adapter
6
4229
Shock Arrestor
1
4280
23 24 25
OTHER PARTS
Form No. 176A Models 350 Page 5
NO.
Model 360 Humidifiers QTY/CTN
PART NO.
Inlet Frame Almond
1
4206
Inlet Frame Gray
1
2
Scale Control Insert
12
3
Water Panel® Evaporator
10
35
4
Distribution Tray
1
4182
5
Distribution Tray Cover
1
4183
6
Nozzle
1
4184
7
Baffle
1
4185
Housing Almond
1
4198
Housing Gray
1
4858
9
Drain Spud
1
4187
10
Fan Blade
1
4215
11
Motor
1
4199
12
Motor Brackets
1 Set
4190
13
Solenoid Valve (Plastic Junction Box)
1
4191
14
Orifice (Blue)
144 (12-12 pks.)
4232
15
1
4258
16
120 Volt Humidifier Control - Replaces 4013 Feed Tube with Strainer, Orifice, Compression Sleeve and Nut
1
4079
17
Junction Box Cover
1
4193
18
Junction Box
1
4194
19
Humidistat
1
4655
20
In-Line Strainer
12
4004
21
Power Cord
1
4286
22
Saddle Valve
1
4001
Outlet Grille Almond
1
4204
Outlet Grille Gray
1
4859
Inlet Wall Frame Almond
1
4205
Inlet Wall Frame Gray
1
4860
Screws and Clips Almond
1
4203
Screws and Clips Gray
1
4850
Saddle Valve Adapter
6
4229
Shock Arrestor
1
4280
1
8
23 24
PART NAME
Model4852350 Humidifiers 4181
OTHER PARTS
6
Model 558, 550A, 550, 568, 560A, 560 Humidifiers (Almond Units)
18
15A or 15B
MODEL 558/550A/550 MODEL 568/560A/560 NO.
PART NAME
1
Water Panel® Evaporator
2
Scale Control Insert
QTY/CTN
PART NO.
10
10
PART NO. 35
(4217-10) (4236-12)
4217
4236
3
Water Distribution Tray
1
4218
4277
4
Base
1
4219
4262*
5
End Panel
1
4220
4263*
6
Duct Panel
1
4221
4264*
6
Duct Panel for Integral Damper
1
4526
N/A
7
Cover With Latch And Label
1
4222
4265*
8
Drain Spud
6
4223
4223
9
Water Solenoid Valve (24 Volt)
1
4040
4040
10
In-Line Strainer
12
4004
4004
11
Saddle Valve
1
4001
4001
12
Orifice (Yellow)
144 (12-12 pks.)
4231
4231
13
Feed Tube with Strainer, Orifice, Compression Sleeve and Nut
1
4226
4266
14
Transformer
1
4010
4010
15A
Automatic Humidifier Control
1
56
56
15B
Manual FormHumidistat No. 176A
1
4655
4655
16
Models 558 - 560, Page 3 Nozzle
1
4184
4184
17
Cover Latch Spring
1
4225
4225
18
Automatic Humidifier Control Gasket
1
4305
4305
QTY/CTN 1
PART NO. 8052
PART NO. 8052
OTHER PARTS Outdoor Temperature Sensor Current Sensing Relay
1
50
50
Saddle Valve Adapter
6
4229
4229
Shock Arrestor
1
4280
4280 N/A
Damper Assembly
1
4332
Maintenance Kits (includes parts 10, 4226, 4231, 4004, 4217, 4218 and 4223)
1
4793
N/A
Maintenance Kits (includes parts 35, 4266, 4231, 4004, 4236, 4277 and 4223) Blower Activation Relay *Part Nos. 4262, 4263, 4264, and 4265 are obsolete
1
N/A
4837
10
4851
4851
O.
0 1 2 3 4
5
6 7
Model 1150, 1160 & 1180 Steam Humidifiers
Model 1150, 1160 & 1180 Steam Humidifiers
PART NAME Steam Chamber, 1150 Steam Chamber, 1160 Steam Chamber, 1180 Quick Release Handle, 1150 Quick Release Handle, 1160 Quick Release Handle, 1180 Cover 1150 & 1160 Cover 1180 Terminal Block Relay, AC Safety (1150) Relay, DC Control (1150) Fuse Holder (1150) Fuse, 25 Amp (1150) Contactor (1160 & 1180) Terminal Transformer Overlay & Switch Internal Control Board Standoff Heater (1150 & 1160) Heater (1180) NO. PART NAME Steam Chamber, 1150 Over-Temperature Thermostat Steam Chamber, 1160 1 Probe Housing Steam Chamber, 1180 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Quick Release Handle, 1150 Quick Release Handle, 1160 Quick Release Handle, 1180 Cover 1150 & 1160 Cover 1180 Terminal Block Relay, AC Safety (1150) Relay, DC Control (1150) Fuse Holder (1150) Fuse, 25 Amp (1150) Contactor (1160 & 1180) Terminal Transformer Overlay & Switch Internal Control Board Standoff Heater (1150 & 1160) Heater (1180) Over-Temperature Thermostat Probe Housing
QTY/CTN PART NO. 1 4560 1 4561 1 4627 1 4562 1 4563 1 4628 1 4564 1 4629 1 4565 1 4566 1 4567 1 4568 1 4569 1 4570 1 4571 1 4572 1 4573 1 4574 1 4575 1 4576 1QTY/CTN PART 4630NO. 4560 1 1 4577 1 4561 1 1 4578 4627 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
4562 4563 4628 4564 4629 4565 4566 4567 4568 4569 4570 4571 4572 4573 4574 4575 4576 4630 4577 4578
NO. 18 19 20 21 22 23 24 25
NO. 18 19 20 21 22 23 24 25
PART NAME Water Level Probe Gasket Water Level Probe Assy Plug Gasket, 1150 Steam Chamber Gasket, 1160 Steam Chamber Gasket, 1180 Steam Chamber Fill Valve Drain Valve Drain Assy Thermal Cutout OTHER PARTS Wiring Harness Hose, 1-1/2" Dia. (1150 & 1160) Hose, 2" Dia. (1180) Distribution Tube, 1-1/2" Dia x 10" (1150) Distribution Tube, 1-1/2" Dia x 16" (1160) Distribution Tube, 2" Dia x 28" (1180) Duct Plate (1150 & 1160) Duct Plate (1180) Airflow Switch PART NAME PART NO. Automatic Steam Humidifier Control Water Level Probe Gasket 4579 Hanging Bracket Water Level Probe Assy 4580 High Humidity Limit Switch Plug 4581 Gasket, 1150 Steam Chamber Gasket, 1160 Steam Chamber Gasket, 1180 Steam Chamber Fill Valve Drain Valve Drain Assy Thermal Cutout OTHER PARTS Wiring Harness Hose, 1-1/2" Dia. (1150 & 1160) Hose, 2" Dia. (1180) Distribution Tube, 1-1/2" Dia x 10" (1150) Distribution Tube, 1-1/2" Dia x 16" (1160) Distribution Tube, 2" Dia x 28" (1180) Duct Plate (1150 & 1160) Duct Plate (1180) Airflow Switch Automatic Steam Humidifier Control Hanging Bracket High Humidity Limit Switch
4582 4583 4631 4584 4585 4587 4595 4637 4588 4632 4589 4590 4633 4591 4636 4592 57 4593 4594
We reserved the right to make modifications as deemed necessary in line with our policy to continue supplying the finest equipment available. All prices are F.O.B. Poynette, WI, and subject to change without notice. Orders may be sent via EDI, Fax, email (
[email protected]), Mail or Phone. If EDI, call us for initial Setup. 7
P.O. Box 1467 • Madison, WI 53701-1467 • Phone: 800/334-6011 • Fax: 608/257-4357 • www.aprilairepartners.com Form No. 176B 03.15
orm No. 176A
Printed in U.S.A. © 2015 Aprilaire – A division of Research Products Corporation