Hyundai Solar Module

Report 4 Downloads 290 Views
Hyundai Solar Module

www.hhi-green.com/solar/en

Hyundai Heavy Industries was founded in 1972 and is a Fortune 500 company. The company employs more than 48,000 people, and has a global leading 7 business divisions with sales of 40.9 Billion USD in 2015. As one of our core businesses of the company, Hyundai Heavy Industries is committed to develop and invest heavily in the field of renewable energy. Hyundai Solar is the largest and the longest standing PV cell and module manufacturer in South Korea. We have 800 MW of module production capacity and provide high-quality solar PV products to more than 3,000 customers worldwide. We strive to achieve one of the most efficient PV modules by establishing an R&D laboratory and investing more than 20 Million USD on innovative technologies.

Poly-crystalline Type HiS-M310RI | HiS-M315RI | HiS-M320RI | HiS-M325RI

RI-Series

Mono-crystalline Type HiS-S330RI | HiS-S335RI | HiS-S340RI | HiS-S345RI | HiS-S350RI | HiS-S355RI

Mechanical Characteristics Dimensions

998 mm (39.29”)(W) × 1,960 mm (77.17”)(L) × 40 mm (1.57”)(H)

Weight

Approx. 22.9 kg (50.5 lbs)

Solar cells

72 cells in series (6 × 12 matrix) (Hyundai cell, Made in Korea)

Output cables

4 mm2 (12AWG) cables with polarized weatherproof connectors, IEC certified (UL listed and UL 4703 certified), Length 1.2 m (47.2”)

Junction box

IP67, weatherproof, IEC certified (UL listed)

Bypass diodes

3 bypass diodes to prevent power decrease by partial shade

Construction

Front : Anti-reflection coated glass (Anti reflection coated), 3.2 mm (0.126”) Encapsulant : EVA Back Sheet : Weatherproof film

Frame

Clear anodized aluminum alloy type 6063

High Quality • IEC 61215 (Ed.2) and IEC 61730 by VDE • UL listed (UL 1703), Type 1 for Class A Fire Rating • Output power tolerance +3/-0 % • ISO 9001:2000 and ISO 14001:2004 Certified • OHSAS 18001:2007 Certified • Advanced Mechanical Test (5,400 Pa) Passed (IEC) / Mechanical Load Test (40 lbs/ft2) Passed (UL) • IEC 62716 (Ammonia Corrosion Resistance Test) Passed • IEC 61701 (Salt Mist Corrosion Test) Passed • Potential-Induced Degradation (PID) Test Passed (85˚C / 85 % / 600 hr-PVEL)

Accredited Test Lab • VDE (Test Data Acceptance Program) • UL (Witness Test Data Program)

Limited Warranty • 10 years for product defect • 10 years for 90 % of warranted min. power • 25 years for 80 % of warranted min. power ※ Important Notice on Warranty The warranties apply only to the PV modules with Hyundai Heavy Industries Co., Ltd.'s logo (shown below) and product serial number on it.

※ Several models are under certification process.

Electrical Characteristics | Poly-crystalline Type | HiS-M Nominal output (Pmpp)

RI

W

310 310

315 315

320 320

325 325 36.6

Voltage at Pmax (Vmpp)

V

36.0

36.2

36.4

Current at Pmax (Impp)

A

8.6

8.7

8.8

8.8

Open circuit voltage (Voc)

V

45.3

45.5

45.7

45.9

Short circuit current (Isc)

A

8.9

9.0

9.0

9.1

Output tolerance

%

No. of cells & connections Cell type Module efficiency

+3/-0

pcs

72 in series

-

6” Poly-crystalline silicon (Hyundai cell, Made in Korea)

%

15.8

16.1

16.4

Temperature coefficient of Pmpp

%/K

Temperature coefficient of Voc

%/K

-0.32

Temperature coefficient of Isc

%/K

0.039

16.6

-0.41

※All data at STC (Standard Test Conditions). Above data may be changed without prior notice.

| Mono-crystalline Type | HiS-S

RI

W

330 330

335 335

340 340

345 345

350 350

355 355

Voltage at Pmax (Vmpp)

V

38.0

38.2

38.4

38.6

38.7

38.9

Current at Pmax (Impp)

A

8.7

8.8

8.9

9.0

9.0

9.1

Open circuit voltage (Voc)

V

46.3

46.5

46.7

46.9

47.1

47.3

Short circuit current (Isc)

A

9.3

9.4

9.5

9.6

9.6

9.6

Output tolerance

%

Nominal output (Pmpp)

No. of cells & connections Cell type Module efficiency

+3/-0

pcs

72 in series

-

6” Mono-crystalline silicon (Hyundai cell, Made in Korea)

%

16.9

17.1

17.4

17.6

Temperature coefficient of Pmpp

%/K

Temperature coefficient of Voc

%/K

-0.30

Temperature coefficient of Isc

%/K

0.047

17.9

18.1

-0.42

※All data at STC (Standard Test Conditions). Above data may be changed without prior notice.

| Module Diagram |

(unit : mm, inch)

| I-V Curves | Current [A]

10 (0.39”)

10

C

4 (0.16”)

3 2 1 0

1.6 (0.06”)

67.2 (2.65”)

DETAIL B 11 (0.43”)

0

| Installation Safety Guide | • Only qualified personnel should install or perform maintenance. • Be aware of dangerous high DC voltage. • Do not damage or scratch the rear surface of the module. • Do not handle or install modules when they are wet.

20

30

Incid. Irrad = 1,000 W/m2

7

Irrad 800 W/m2 76Incid. (2.99”) 80=(3.14”)

3

Incid. Irrad = 200 W/m2

1 0

Cell temp. = 25˚C 5.7 (0.22”)

Incid. Irrad = 400 W/m2

2

35 (1.38”)

50

Voltage [V]

2 Incid.DETAIL Irrad = 600 C W/m

4

DETAIL C

40

8 (0.32”)

9

8 (0.32”) 8

5

40 (1.57”) 1.8 (0.07”)

430 (16.93”) 252 (9.92”)

10

Current [A]

6 15 (0.59”)

948 (37.32”)

A

Incid. Irrad = 1,000 W/m2 Operating Cell Temp = 5˚C Operating Cell Temp = 25˚C Operating Cell Temp = 45˚C Operating Cell Temp = 65˚C

4

8-Ø7 SLOT THRU 8 (0.32”)

4 X Ø4.2 GROUND HOLE

652 (25.67”) 998 (39.29”)

5

DETAIL A

878 (34.57”)

GROUND MARK

7 6

(+) 1,200 mm (47.24”) 4 mm2 CABLE & CONNECTOR

1,960 (77.17”)

(-) 1,200 mm (47.24”) 4 mm2 CABLE & CONNECTOR

8

6.5 (0.26”)

4 X Ø7-L11 HOLES B

9

0

5

10

15

20

25

30

35

40

45

50

Voltage [V]

Nominal Operating Cell Temperature

46˚C ± 2

Operating Temperature

-40 - 85˚C DC 1,000 V (IEC) DC 1,000 V (UL) 15 A

Maximum System Voltage Maximum Reverse Current

[ Printed Date : December 2016 ]

Sales & Marketing Hyundai Bldg., 75, Yulgok-ro, Jongno-gu, Seoul 03058, Korea Tel : +82-2-746-7563, 7635, 8406 Fax : +82-2-746-7675