IC HIGH OUTPUT

Report 8 Downloads 94 Views
IC HIGH OUTPUT

Premium Turret Industrial / 2, 3, or 4-Lamp T8 or T12 PROJECT INFORMATION Project Name

Type

Catalog No.

Date

CONSTRUCTION

Heavy steel housing with longitudinal reinforcing ribs for extra strength. Spring-loaded turret socket assemblies provide added security for vibration prone environments. Optional full depth endplates meet bottom of reflector, recommended for use with wireguard or baffle accessories. FINISH

FEATURES • Specification grade, heavy duty, one-piece steel housing • Fully assembled, shipped in one carton • Optional deep “V” reflector provides 35° crosswise shielding with T8 lamps and 39° shielding with T12 lamps (formerly known as “IM” Imperial) • Available with 10% uplight or solid top for 100% downlight • Optional full end plates • Textile mill option eliminates upturned edges on the reflector to inhibit the accumulation of lint and dust • White powder coat finish painted after fabrication • Embossed ribs and aperture edges provide superior rigidity • Spring loaded turret style sockets provide excellent lamp retention

White painted parts are treated with a five stage phosphate bonding process and finished after fabrication with a minimum 90% reflective gloss baked enamel. ELECTRICAL

MODEL

SIZE 4 4' 8 8'

– NO. OF LAMPS IN CROSS SECTION 2 Two 3 Three

ACCESSORIES (ORDER SEPARATELY) ICWG4 ICFSA12 ICWCB ICVWCB ICRC ICBC ICCN ICHC ICAC OS1360K

1 2

EXAMPLE IC8-296HO-VR-EPU-ICFC-ICCN



IC Premium Turret Industrial

4' Wire Guard1 Steel Door with A12 Lens White Cross Baffle for Std. Reflector White Cross Baffle for “V” Reflector Rod Clamp Hanger Box/Conduit Clamp Hanger Channel Connector Chain Hanger Assembly Reflector Aligner Occupancy/Daylight sensor kit, 120/277/347V, one relay, 360 Lens, snap on drop down adaptor, quick connect wiring2

CERTIFICATION

All luminaires are built to UL 1598 standards and bear appropriate UL and cUL or CSA labels. Damp location labeling is standard. Emergency-equipped fixtures labeled UL 924.

Standard class “P,” thermally protected, autoresetting HPF ballast, sound rated A. All ballast leads extend a minimum of 6" through access location. NEC/CEC-compliant ballast disconnect is standard.

ORDERING INFORMATION IC

INSTALLATION

For surface or suspended installation. Mounting accessories may be ordered separately.



EP

LAMP TYPE

REFLECTOR TYPE

BALLAST

48HO 4', T12: 60 Watt (Specify voltage) 96HO 8', T12: 110 or 95 Watt 96T8HO 8', T8: 86 Watt

U Apertured 10% Uplight Reflector ST Solid Top 0% Uplight Reflector* VR Deep V 25% Uplight Reflector (2 lamps only) TU 10% Uplight Textile Reflector TST Solid Top Textile Reflector* *Not recommended for HO units.

EP Electronic Rapid Start

– VOLTAGE U 120 277 347

OPTIONS

120V-277V 120V 277V 347V

ICFC Full End Caps ICNC No End Caps (Row mounting) BC1 Branch Circuit Wiring Single Circuit (For more branch circuit wiring options see page xxx) GLR Fast Blow Fuse GMF Slow Blow Fuse EL Emergency Battery Pack RIF Radio Interference Filter NYC NYC Compliant NYCU NYC Compliant, Union Label

Not recommended for TU or TST reflectors. Use programmed start ballast. Not recommended for use with instant start. For more occupancy/daylight harvesting sensor accessories see Technical section.

Page 1/2 Rev. 06/10/16 © 2016 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com

INDUSTRIALS / IC HIGH OUTPUT

IC HIGH OUTPUT

Premium Turret Industrial / 2, 3, or 4-Lamp T8 or T12

PHOTOMETRIC DATA

Test HP05432 Test Date 2/18/09

LUMINAIRE DATA

Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet

ZONAL LUMEN SUMMARY Zone

IC4-248HO IC Industrial 13.5" × 48" 2-Lamp with Polyester Painted Apertured Steel Reflector – 0.95 – 4050 151 Surface 0º = 0  90º = 0 0º = 1.27  90º = 1.24 Length: 4.06 Width: 1.10 Height: 0.00

Lumens %Lamp

0-30 0-40 0-60 0-90 0-180

1718 2809 4984 6424 7366

ENERGY DATA

%Fixt.

21.2 34.7 61.5 79.3 90.9

23.3 38.1 67.7 87.2 100.0

INDOOR CANDELA PLOT

RCR

70 96 87 79 73 67 61 57 53 49 46

80 50 30 92 88 80 74 70 63 62 54 55 47 49 41 45 37 41 33 37 30 34 27

10 84 68 57 48 41 36 31 28 25 23

70 92 84 76 70 64 59 55 51 48 45

70 50 30 89 85 77 71 68 61 60 52 53 46 48 40 43 36 40 32 36 29 34 27

10 82 67 55 47 40 35 31 27 25 22

50 83 72 63 56 50 45 41 38 34 32

50 30 80 67 58 50 44 39 35 31 28 26

10 77 63 53 45 39 34 30 27 24 22

90.9%

Luminaire Efficacy Rating (LER) IESNA RP-1-1993 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

47 Noncompliant $5.11 based on 3000 hrs. and $0.08 per KWH

AVG. LUMINANCE (Candela/Sq. M.)

120

COEFFICIENTS OF UTILIZATION (%) RC RW 1 2 3 4 5 6 7 8 9 10

Total Luminaire Efficiency

Average Luminance Angle

Luminaire

0 0 66 55 46 39 34 29 26 23 21 19

0 30 40 45 50 55 60 65 70 75 80 85

0.0

22.5

45.0

67.5

90.0

5295 5227 5169 5140 5069 4979 4878 4705 4461 4107 3539 2572

5295 5260 5163 5099 5006 4862 4666 4637 4397 4032 4331 3512

5295 5165 4996 4936 5036 4895 4594 4431 4714 5187 3456 2738

5295 5112 5069 5171 4916 4685 4575 4893 5461 4302 2415 2295

5295 5085 5147 5075 4811 4614 4599 5076 5468 3706 2318 2157

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

DIMENSIONAL DATA

63/4" 69/16"

63/4"

139/16" 2-Lamp Standard Reflector

61/2" 139/16"

ICWCB

139/16" 2-Lamp Deep-V Reflector

ICVWCB

69/16" ICBC ICRC 61/2" 139/16" 395/8" 36"

18"

117/16"

1/2" Dia. K.O.

7/8" Dia. K.O. 11/32" Dia. K.O.

7/8" Dia. K.O.

7/8" Dia. K.O. 7/8" Dia. K.O. 11/32" Dia. K.O.

Page 2/2 Rev. 06/10/16 © 2016 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com

INDUSTRIALS / IC HIGH OUTPUT