Icecore® Remote Refrigeration Units Icecore® Remote Refrigeration ...

Report 3 Downloads 75 Views
Icecore® Remote Refrigeration Units Icecore® Remote Refrigeration Units

44G • 50G • 44HC

44G • 50G • 44HC

NEW, VING G R ENE Y-SA FEATURES!

The Icecore® provides the most consistent, high-quality beverages in the industry.

Standard Features • Uses up to 30% less energy than previous models. • New, magnetic-drive circulation pump improves reliability by eliminating pump seal. • Patent-pending control software monitors demand and reduces low-demand energy consumption • All water used for cooling drinks is recycled with virtually no waste water; reduces water and sewage expenses. • Durable, easy-to-clean stainless steel cabinet.

ISO 9001:2000 Quality System Certified

2100 Future Drive

Tel: 812.246.7000

Sellersburg, IN 47172 USA

Fax: 812.246.7024

www.manitowocbeverage.com/us

Specifications Standard Features

Electrical

Icecore 50G

Icecore 44 HC

Internal cold carbonation, magnetic-drive circulation pump, stainless steel cabinet

Volts

208-230

208-230

208-230

340-440

220

Hz

60

50

60

50

50

Phase

1

1

3

3

1

Minimum Circuit Amps

21

20

26

15

NA*

Maximum Breaker Size

30

30

30

20

NA*

Compressor

1.0 hp / 1.6 kW

2.2 hp / 2.2 kW

2/3 hp / 1.242 kW

140 lbs / 63.3 kgs

200 lbs / 90.5 kgs

140 lbs / 63.3 kgs

Evaporator Rating (20°F / -6.5°C)

9,700 BTUH / 2,444 kcal/hr

14,900 BTUH / 5,143 kcal/hr

16,400 BTUH / 4,132 kcal/hr

Heat Rejection (Maximum)

13,576 BTUH / 3,421 kcal/hr

20,408 BTUH / 5,143 kcal/hr

16,378 BTUH / 4,270 kcal/hr

Ice Bank Size (Nominal)

Coolant Condenser Types Drink Capacity per hour @ 75°F (24°C) Peak (max for 2 hr period) / Sustained Maximum Conduit Length

R-404A

R-290**

Air-cooled, water-cooled or remote

Air-cooled

500 / 288

600 / 420

500/288

250 ft / 76 m

350 ft / 107 m

250 ft / 76 m

Syrup Coils (Standard/Maximum)

8 / 12

8 / 14

8 / 12

Shipping Weight (Approximate)

340 lbs / 154 kgs

395 lbs / 179 kgs

340 lbs / 154 kgs

Options

Legs, stand, additional syrup coils, casters * This model is not hard wired

Incoming Syrup Supply Lines

A

CO2 Regulator Panel (Optional)

B

Drain Connection

Side View

Dimensions Depth

Height

Leg Height

Drain Connection A

Drain Connection B

Model 44G

39.75"

24.75"

30.25"

6"

12"

6"

101 cm

62.9 cm

76.83 cm

15.2 cm

30.5 cm

15.2 cm

42.25"

28.25"

32.00"

6"

14"

8.5"

107.3 cm

71.8 cm

81.3 cm

15.2 cm

35.6 cm

21.6 cm

39.75"

24.75"

30.25"

6"

12"

6"

101 cm

62.9 cm

76.83 cm

15.2 cm

30.5 cm

15.2 cm

2100 Future Drive

Tel: 812.246.7000

Sellersburg, IN 47172 USA

Fax: 812.246.7024 www.manitowocbeverage.com/us

Control Switches Air Flow

Depth

Height

Leg Height

Width

Wall

18" (45.7 cm) minimum

Top View

Width

Model 44HC

11" (28 cm)

6" (15.2 cm) Diameter Chase minimum

Unit

Model 50G

Electrical Junction Box

3.875" (9.8 cm) Diameter

Drain Connection Floor drain should be located within 6 ft. (183 cm) of unit

Front View

6" (15.2 cm) minimum

Wall

Incoming CO2 Supply Line

12" (30.5 cm) minimum Wall

Incoming Water Line

Wall

18" (45.7 cm) minimum

Wall

Junction Box

4859C ©2015 Multiplex 11/15 Continuing product improvement may necessitate change

Ceiling Conduit to Dispensing Towers

of specifications without notice.

** Check your local agencies for R290 Hydro-Carbon refrigerant acceptance

Wall

Icecore® Remote Refrigeration Units

44G • 50G • 44HC

Icecore 44G