In Process amazonaws com

Report 5 Downloads 145 Views
DocuSign Envelope ID: BE3AF23A-4853-493F-B33B-34F4F230753C

PLEASE CHECK SIZES ON DRAWINGS CAREFULLY. ANY CHANGES ON WIDTH OR HEIGHT WILL REQUIRE REVISED DRAWINGS FOR FINAL APPROVAL.

NANAWALL PRODUCT DRAWINGS GENERAL NOTES

QUOTE NUMBER: 308028 ORDER NUMBER: 19203 PROJECT NAME: TERRELL PLACE WASHINGTON DC CUSTOMER: DORMA CAROLINA DOOR CONTROLS COLUMBIA MD

In Process

ABBREVIATIONS

SYSTEM INFORMATION A/C A.F.F. C.O.H. C L DIM. D.L.O. D.O. EL. F.S. F.F. G.C. L.P.S.S. N.B.N. N.I.C.

= = = = = = = = = = = = = =

ACCESS CONTROLLED ABOVE FINISHED FLOOR CENTER OF HORIZONTAL CENTER LINE DIMENSION DAYLIGHT OPENING DOOR OPENING ELEVATION FRAME SIZE FINISHED FLOOR GENERAL CONTRACTOR LOW PROFILE SADDLE SILL NOT BY NANA WALL NOT IN CONTRACT

N.T.S. O.D. O.F.D. R.O. S.D.L. T.B.D. T.O.F.F. T.O.H. U.W. V.I.F. W.D. W.P.

= = = = = = = = = = = =

NOT TO SCALE OPENING DIMENSION OVERALL FRAME DIMENSION ROUGH OPENING SIMULATED DIVIDED LITE TO BE DETERMINED TOP OF FINISHED FLOOR TOP OF HORIZONTAL UNIT WIDTH VERIFY IN FIELD WINDOW DIMENSION WORKING POINT

SYSTEM ON THIS DRAWING: SL45 FOLDING SYSTEMS (ALUMINUM) CONFIGURATION: INWARD CENTER PIVOT UNHINGED PAIRED PANELS 5 LEFT/RIGHT TYPE OF GLASS: 1/4" SINGLE LAMINATED HARDWARE FOLDING DOORS: TWO POINT LOCKING WITH FLAT HANDLE ON INSIDE ONLY(NOTE THAT PANELS ARE OPERABLE FROM INSIDE ONLY AND THERE IS NO LATCH.) HANDLE FINISH: STAINLESS STEEL WITH BLACK TITANIUM FINISH HINGE FINISH: POWDER COATED MATCH SILL TYPE: NON-THERMALLY BROKEN FLUSH (NO RATING AGAINST WIND DRIVEN RAIN OR SURFACE WATER)

SYMBOLS DENOTES BLOCKING OR SHIM, NOT CONTINUOUS, NOT NECESSARILY ONE PIECE

1. NANAWALL SYSTEMS IS ONLY A MATERIAL SUPPLIER OF SLIDING & FOLDING PANEL SYSTEMS. NANAWALL SYSTEMS DOES NOT PROVIDE INSTALLATION AND DOES NOT DESIGN OR ENGINEER ANY SURROUNDING CONDITIONS AROUND THE OPENINGS TO WHICH NANAWALL'S SYSTEMS ARE TO BE INSTALLED. ANY SURROUNDING CONDITIONS SHOWN, IF ANY, IN THESE DRAWINGS ARE MEANT FOR ILLUSTRATIVE PURPOSES ONLY AND WHAT IS SHOWN MAY NOT SUITABLE FOR ANY PARTICULAR PROJECT. 2. AS REGULATIONS GOVERNING THE USE OF GLAZED WINDOWS, DOORS, STOREFRONTS AND/OR PARTITIONS VARY WIDELY, IT IS THE SOLE RESPONSIBILITY OF THE ARCHITECT, BUILDING OWNER, CONTRACTOR AND/OR CONSUMER (HERINAFTER REFERRED TO AS "CUSTOMER") TO ENSURE THAT REGULATIONS, INCLUDING FEDERAL, STATE AND LOCAL ARE ADHERED TO. 3. PROPER INSTALLATION, OPERATION AND MAINTENANCE OF NANA WALL SYSTEMS PRODUCTS ARE ESSENTIAL FOR PROPER PERFORMANCE. WRITTEN INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS ARE AVAILABLE AND PROVIDED TO ALL CUSTOMERS. IT IS ESSENTIAL THAT THESE INSTRUCTIONS BE READ AND FOLLOWED. IT IS HIGHLY RECOMMENDED THAT AN EXPERIENCED INSTALLER OF NANAWALL'S PRODUCTS BE USED FOR RELEVANT ASPECTS OF INSTALLATION. INSTALLATION TO BE PROVIDED BY OTHERS, INCLUDING BUT NOT LIMITED TO METHOD OF ATTACHMENT, FASTENER SELECTION AND COMPLETION OF APPROPRIATE WATERPROOFING, FLASHING AND APPLYING SEALANT OR CAULK AROUND THE PERIMETER OF THE OPENING, IS THE SOLE RESPONSIBILITY OF THE CUSTOMER. 4. THE STRUCTURAL INTEGRITY OF HEADER AND/OR OVERHEAD SUPPORT FOR THE OPENING AND ANY STACKING AREAS, TO BE PROVIDED AND INSTALLED BY OTHERS, IT IS CRITICAL FOR PROPER PERFORMANCE AND OPERATION. AMONG OTHER FACTORS, THE DEFLECTION UNDER FULL LIVE AND DEAD LOADS SHOULD BE THE LESSER OF L/720 OF THE SPAN OR 1/4". THE HEADER, SURROUNDING WALLS AND FLOOR MUST ALSO BE ABLE TO SUPPORT ANY LATERAL LOADS. 5. WATER RESISTANCE IS RELATIVE. MANY OF NANAWALL'S SYSTEMS WITH CERTAIN CONFIGURATIONS AND SILLS HAVE BEEN TESTED WITH VARYING DEGREES OF PERFORMANCE RESULTS. CERTAIN SILLS SUCH AS THE RAISED SILL, IF AVAILABLE FOR A SYSTEM, PERFORM BETTER AND OTHER SILLS NEED TO BE SITE MODIFIED BY OTHERS WITH WEEP HOLES AND PROPER DRAINAGE FOR BETTER PERFORMANCE. NON-STANDARD UNITS SUCH AS SEGMENTED CORNERLESS, ETC. PERFORMANCE RATING WILL BE LESS THAN A STANDARD UNIT. SEE INFORMATION AVAILABLE IN NANAWALL'S LITERATURE AND WEBSITE. IT IS THE SOLE RESPONSIBILITY OF THE CUSTOMER TO DETERMINE THE LEVEL OF PERFORMANCE NEEDED FOR THEIR SPECIFIC LOCATION AND SITE CONDITIONS AND CHOOSE THE APPROPRIATE NANAWALL SYSTEM, SIZE AND SILL FOR IT. 6. ALL DRAWINGS ARE ACCURATE IN METRIC DIMENSIONS. ENGLISH DIMENSIONS SHOWN ARE ROUNDED TO THE NEAREST 1/16". PRODUCT DRAWINGS SHOULD NOT BE SCALED. SCALE NOTED ON DRAWINGS ARE BASED ON A 24"X36" PAPER FORMAT

SILL FINISH: DARK BRONZE ANODIZED

7. NANAWALL WILL ASSUME NO RESPONSIBILITY FOR ERRORS RESULTING FROM THE USE OF THESE DRAWINGS BY OTHER TRADES. ANCHOR LOCATION

8. THESE DRAWINGS HAVE BEEN PREPARED IN ACCORDANCE WITH NANAWALL'S QUOTATION OR PER AN ACCEPTED CHANGE ORDER AND OTHER APPLICABLE CONTRACT DOCUMENTS. 9. FINAL APPROVAL BY THE GENERAL CONTRACTOR CONSTITUTES ACCEPTANCE OF ALL DEVIATIONS TO THE CONTRACT DOCUMENTS MADE BY NANAWALL IN THESE DRAWINGS. 10. THESE DRAWINGS REPRESENT NANAWALL'S INTERPRETATION OF THE APPLICATION OF PRODUCTS TO THIS PROJECT IN FUNCTIONAL COMPLIANCE WITH NANAWALL'S QUOTE TO CUSTOMER. IT IS IMPORTANT THAT THIS INTERPRETATION BE REVIEWED DIMENSIONALLY AND FUNCTIONALLY WITH RESPECT TO ACTUAL ARCHITECT INTENT, INTERFACING CONDITIONS, MATERIALS AND JOB SITE CONDITIONS.

FASTENER LOCATION

DIMENSIONAL REFERENCE / ELEVATION

WORKING POINT

S

FIELD APPLIED SEALANT BY GLAZING SUB CONTRACTOR

PROFILE FINISH SCHEDULE WOOD

SD

SHOP DRILL

FD

FIELD DRILL

DESCRIPTION:

11. ALL GLASS AND FINISHED MATERIAL MUST BE PROTECTED DURING WELDING OPERATIONS, FIREPROOFING OR ANY OTHER PROCESS THAT MAY BE HARMFUL TO THE APPEARANCE OR PERFORMANCE OF THE PROJECT MATERIALS. 12. THE ROUGH OPENINGS PROVIDED MUST BE SQUARE AND WITHIN SPECIFIED BUILDING TOLERANCES.

ANODIZED ALUMINUM 1

GLAZING INDICATION NUMBER

13. PERIMETER FASTENERS AND SUBSTRATE MUST BE CAPABLE OF WITHSTANDING REACTION FORCES IMPOSED BY WIND AND/OR DEAD LOAD. NANAWALL WILL NOT BE LIABLE FOR INSUFFICIENT ANCHORING AND/OR SUBSTRATE.

DETAIL NUMBER SHEET NUMBER

POWDER COATED ALUMINUM NANAWALL STANDARD COLOR: MEDIUM BRONZE METALLIC -T

14. NANAWALL DOES NOT PROVIDE NOR TAKE RESPONSIBILITY FOR SIZES, LOCATIONS OR FREQUENCY OF PERIMETER FASTENERS. VIA OMISSION OF STRUCTURAL CALCULATIONS, NANAWALL ASSUMES NO RESPONSIBILITY FOR ENGINEERING OF DETAILED ALUMINUM, WOOD AND GLASS SYSTEMS.

ARCHITECTURAL REFERENCE: SHEET NO. ARCHITECTURAL REFERENCE: DETAIL NO.

15. USING EXPANDABLE FOAM WILL VOID NANAWALL'S WARRANTY.

SHEET INDEX ELEVATION/PLAN/SECTION TITLE

1

REVISION NO. (SMALL TRIANGLE) DOOR NUMBER

A 4.01

1

ELEVATION LOCATION-VIEW POINT

NO.

DESCRIPTION

1

COVER SHEET

2

INSTALLATION DETAIL SHEET(S)

NFRC:

3

ELEVATIONS & PLAN SECTIONS

SHGC:

4-4

DETAIL SHEET(S)

EXTRA INFORMATIONS ~UNIT WEIGHT: 800

WINDLOAD:

ELEVATION MARK/TITLE ELEVATION SHEET NUMBER

TYPICAL DETAIL CALLOUT

HEAD TRACK AND SILL COMPONENTS MAY BE SHIPPED IN SEGMENTS THAT WILL BE NEED TO FIELD JOINED

ELEVATIONS ARE VIEWED FROM THE INTERIOR, TYPICAL.

OUTSIDE UNIT DIMENSIONS ARE SHOWN ON THESE DRAWINGS. PLEASE ALLOW SHIM SPACE FOR ROUGH OPENING DIMENSIONS. INSTALLATION DEPENDS ON JOB SITE CONDITIONS. SEE OWNERS MANUAL FOR SUGGESTIONS.

PLEASE ADVISE IF THERE ARE LIMITATIONS ON MAX. LENGTHS TO BE SUPPLIED SUCH AS ELEVATOR CAPACITY, ETC

\initial_1_1\

DENOTES BACKER ROD OR CAULK ROPE

DocuSign Envelope ID: BE3AF23A-4853-493F-B33B-34F4F230753C

DETAILS ON PAGE 2 ARE NOT TO SCALE (SEE OWNER'S MANUAL FOR MORE DETAILS)

In Process

\initial_1_1\

1 FLAT HANDLE IN STAINLESS STEEL

IN CUT OUT DIMENSIONS FOR FLUSH SILL

SUGGESTED TYPICAL SG INSTALLATION FOR HEAD TRACK

DocuSign Envelope ID: BE3AF23A-4853-493F-B33B-34F4F230753C

\initial_1_1\

In Process

DocuSign Envelope ID: BE3AF23A-4853-493F-B33B-34F4F230753C

In Process EXTERIOR

INTERIOR

INTERIOR

INTERIOR

\initial_1_1\

EXTERIOR

EXTERIOR

EXTERIOR

EXTERIOR

INTERIOR INTERIOR