Indecon Louvered 2, 3-Lamp T8, Direct/Indirect Distribution Project Information Project Name
Type
Catalog No.
Date
Construction The Indecon series is constructed of heavy 20 gauge steel with a 99/16" × 3⅛" profile. The perforations measure .095" in diameter and provide a 23% opening per square inch. Fixtures are available with two or three T8 lamps. A unique angling method on the middle lamp minimizes the length of the fixture without affecting performance or operation. The exact shape of the housing is maintained by the use of an inner structural plate at each socket location. This plate is tabbed and welded into the housing, ensuring housing tolerances are maintained. Aligner fingers are standard on the plate enabling fixtures to be attached together in straight continuous rows without any snaking or twisting.
Features • A gently pointed shape enhances this curved profile • Primarily indirect, Indecon is well-suited to office, education, and health care where uplight is desired as the primary source • T8, T5, or T5HO lamps • Heavy 20-gauge steel construction provides excellent housing rigidity • 3⅛" deep housing is gently angled for visual interest • Fixed 18" (FCM18) or optional Adjustable 48" (CM48) aircraft cable suspension mountings available • Finger tab connections for quick and easy alignment • Modular mounting points for predictable hanging locations • UL Listed 1598
Louver The straight blade louvers are constructed of 20-gauge steel, are 24" in length, and are painted white. There is one louver for a 4' unit, two for an 8', and 3 for a 12' unit. Perforations on the louver measure .095" in diameter and have an opening of 23% per square inch. The louvers are attached from above and cannot be removed without removing the reflector system. The louver provides 13% downlight when a three lamp system is used.
Shape and Dimensions 3⅛" 9⁹⁄₁₆"
Ordering Information
IDCL — Model IDCL Indecon Louvered
—
LAMP TYPE AND PROFILE 2T8 Two T8 Lamps 3T8 Three T8 Lamps
—
2 3
Labels and Electrical —UL listed 1598. cUL or CSA. Damp location listed. —Quick-connect plugs standard.
Name: Test #: Efficiency: LER:
—
MOUNTING FCM Fixed Cable Mount (Non-adjustable, Std.) CM Adjustable Aircraft Cable Mount
Housing type PERF Perforated S Solid
Adjustable Cable length 48 48" 96 96" Other lengths available on request.
Specify voltage. For additional, specify quantity before nomenclature (Example: 2EL120). Not available with all configurations; some limitations apply. Contact factory for details. One extra feed drop per EMC/NLC. For through wiring, contact factory.
1
Mounting The Indecon is designed for ceiling suspension and is provided with a aircraft cable suspension mechanism. The cable has a total vertical adjustment of 1¼". End of cable barrel screws into a standard ¼-20 bolt brought down from the ceiling. Cover plates are provided to shield the ceiling cutout. A straight or optional coil cord is provided for feed locations. A feed canopy is provided for each feed location. All fixtures are suspended at 48" increments and must be supported at each fixture housing end. Refer to the Indecon TID sheet for actual hanging points for specific rows.
IDCL-2T8-S-E-WR 12586 74.5% 84
Example: IDCL-8-2T8-S-CM48-EU-MW
—
Row length 4' Single 8' Single 12' Single Indicate row length over 12' in 4' increments Note: Rows over 12' will be configured by Alera. Example: 16' will be (2) 8'. Alternate configurations: contact factory. 4 8 12 —
Finish The housing and all painted parts are treated with a five stage phosphate bonding process before being finished. Parts are then finished with a white RAL powder coat finish for maximum consistent coverage and longevity.
— U 120 277 347
Voltage 120V-277V 120V 277V 347V
Ballast E Electronic, Instant Start, (Std. for T8) EP Electronic, Programmed Start (Optional for T8) ED Electronic, Dimming (Must specify) Unless specified, Alera will use fewest ballasts possible.
— Finish MW Matte White (Std.) ZT ZET Metallic Silver See Color Selection Guide for other colors.
DC WR HRF LR IBOB EL EMC NLC GLR GMF TBAR
Options Dust Cover White Reflector High Efficiency Reflector Left/Right Switching (2-Lamp only) Inboard/Outboard Switching (3-Lamp only) One Emergency Battery Pack1, 2 One Emergency Circuit2, 3 Night Light Circuit2, 3 Fast Blow Fuse Slow Blow Fuse T-Bar Mounting
Page 1/2 Rev. 06/26/13 © 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com
Curves / IDCL
Indecon Louvered 2, 3-Lamp T8, Direct/Indirect Distribution Cross section
3⅛"
3⅛"
3⅛"
9⁹/₁₆"
9⁹/₁₆"
9⁹/₁₆"
One Lamp
Two Lamp
Three Lamp
Photometric Data
Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet
IDCL-2T8-PERF-E-LSH Indecon Architectural Curve 9.5" × 48" 2-Lamp w/Perf Bottom, Perf Louver, and Uplight Lens B232I120RH 0.88 F32T8 2900 56 Pendant 0º = 41 90º = 44 0º = 1.76 90º = 2.09 Length: 3.33 Width: 0.49 Height: 0.00
Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) 0 30 40 45 50 55 60 65 70 75 80 85
0.0 22.5 45.0 67.5 90.0
165 229 258 261 246 219 185 156 135 102 76 0
165 244 267 271 267 230 198 187 174 153 152 76
165 259 301 308 287 265 251 234 212 204 152 151
165 289 336 336 328 299 290 281 251 229 190 151
165 305 362 364 349 322 303 281 251 229 228 227
Zonal Lumen Summary Zone
0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180
Lumens % Lamp % Fixt. 27 49 95 120 974 1803 3344 4188 4308
0.5 0.8 1.6 2.1 16.8 31.1 57.6 72.2 74.3
0.6 1.1 2.2 2.8 22.6 41.8 77.6 97.2 100.0
RCR
Luminaire
Angle
Luminaire Data Test 12419
RC RW 1 2 3 4 5 6 7 8 9 10
70 65 59 54 49 45 41 38 35 32 30
80 50 30 62 59 54 50 47 42 42 36 37 31 33 27 29 24 26 21 24 19 22 17
10 57 46 38 32 27 23 20 17 15 13
70 56 50 46 42 38 35 32 30 27 26
70 50 30 53 51 46 43 41 37 36 31 32 27 28 24 25 21 23 18 21 16 19 15
10 49 40 33 28 24 20 18 15 13 12
50 37 32 28 25 22 20 18 16 14 13
50 30 36 30 26 22 19 17 15 13 12 10
10 34 28 24 20 17 15 13 11 10 8
0 0 2 1 1 1 1 1 1 1 0 0
Indoor Candela Plot 180 165 150 135 1400 120 700 105 90
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
75 700
Energy Data Total Luminaire Efficiency Luminaire Efficacy Rating (LER) Comparative Yearly Lighting Energy Cost per 1000 Lumens
74.3% 68 $3.53 based on 3000 hrs. and $0.08 per KWH
60 1400 0
15 30 Horiz 0-180 90.0 45.0
0.0
45
Test Date 12/9/99
Photometric Data
Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet
IDCL-3T8-PERF-E-LSH Indecon Architectural Curve 9.5" × 48" 2-Lamp w/Perf Bottom, Perf Louvers, and Uplight Lens B332I120RHH 1.18 F32T8 2900 107 Pendant 0º = 41 90º = 44 0º = 0.98 90º = 0.93 Length: 3.33 Width: 0.49 Height: 0.00
Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) 0.0 22.5 45.0 67.5 90.0
0 1689 1689 1689 1689 1689 30 1234 1264 1181 1074 1066 40 1051 1051 904 870 904 45 933 933 821 858 942 50 842 811 770 893 944 55 759 702 736 817 851 60 699 633 699 752 792 65 609 593 671 718 734 70 540 540 636 656 675 75 484 484 561 586 612 80 380 456 494 532 532 85 303 303 378 378 454
Zonal Lumen Summary Zone
0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180
Lumens % Lamp % Fixt. 171 254 388 459 1228 2348 4522 5772 6231
2.0 2.9 4.5 5.3 14.1 27.0 52.0 66.3 71.6
2.8 4.1 6.2 7.4 19.7 37.7 72.6 92.6 100.0
RCR
Luminaire
Angle
Luminaire Data Test 12418
RC RW 1 2 3 4 5 6 7 8 9 10
70 63 58 53 48 44 40 37 34 32 29
80 50 30 60 58 53 49 46 42 41 36 36 31 32 27 29 24 26 21 24 19 21 17
10 55 45 38 32 27 23 20 17 15 14
70 55 50 45 41 38 35 32 30 27 26
70 50 30 52 50 46 43 40 36 36 31 32 27 28 24 25 21 23 18 21 16 19 15
10 48 40 33 28 24 20 18 15 14 12
50 37 33 29 26 23 20 18 17 15 14
50 30 36 31 26 23 20 17 15 14 12 11
10 35 29 24 21 18 15 13 12 10 9
Indoor Candela Plot 0 0 5 4 3 3 3 2 2 2 2 2
180 165 2000
150
120 1000 105 90
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
75 1000
Energy Data Total Luminaire Efficiency Luminaire Efficacy Rating (LER) Comparative Yearly Lighting Energy Cost per 1000 Lumens
135
60 71.6% 69 $3.48 based on 3000 hrs. and $0.08 per KWH
2000 0 0.0
15 30 Horiz 0-180 90.0 45.0
Page 2/2 Rev. 06/26/13 © 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com
45
Test Date 12/9/99 Curves / IDCL