Indoor Air Quality Disclaimer GENERAL BACKGROUND ON INDOOR AIR QUALITY In the last several years, a growing body of scientific evidence has indicated that the air within homes and other buildings can be more seriously polluted than the outdoor air in even the largest and most industrialized cities. Other research indicates that people spend approximately 90 percent of their time indoors. Thus, for many people, the risks to health may be greater due to exposure to air pollution indoors than outdoors. In addition, people who may be exposed to indoor air pollutants for the longest periods of time are often those most susceptible to the effects of indoor air pollution. Such groups include the young, the elderly, and the chronically ill, especially those suffering from respiratory or cardiovascular disease. While pollutant levels from individual sources may not pose a significant health risk by themselves, most homes have more than one source that contributes to indoor air pollution. There can be a serious risk from the cumulative effects of these sources. Fortunately, there are steps that most people can take both to reduce the risk from existing sources and to prevent new problems from occurring. The U.S. Environmental Protection Agency (EPA) and the U.S. Consumer Product Safety Commission (CPSC) produce a popular and comprehensive publication on the subject of Indoor Air Quality entitled The Inside Story: A Guide to Indoor Air Quality. It describes sources of air pollution in the home and office, corrective strategies, and specific measures for reducing pollutant levels. This illustrated booklet covers all major sources of pollution such as biological contaminants (including bacteria, molds, mildew, viruses, animal dander and cat saliva, house dust mites, cockroaches, and pollen), radon, household chemicals, carbon monoxide, formaldehyde, pesticides, asbestos, and lead. U.S. Inspect advises homebuyers and homeowners to research Indoor Air Quality issues through resources available at the federal, state and/or local government levels. The EPA website at www.epa.gov is an informative resource for information on Indoor Air Quality. For individuals without access to the Internet, federal agencies with Indoor Air Quality information include the EPA’s Indoor Air Quality Information Clearinghouse (IAQ INFO) at P.O. Box 37133, Washington, DC, 200137133; (800) 438-4318; (703) 356-4020. Single copies of The Inside Story: A Guide to Indoor Air Quality are available from EPA's IAQ Information Clearinghouse or by visiting the EPA website at www.epa.gov/iaq/pubs/ (the website is recommended for the most up-to-date scientific and technical information). Questions or concerns about Indoor Air Quality issues can also be answered by a variety of state or local government agencies. Calling or writing the agencies responsible for health or air quality control is the best way to start getting information from a state or local government agency. To obtain state agency contacts, individuals can write, call or visit EPA’s IAQ Information Clearinghouse. NO INDOOR AIR QUALITY SERVICES PERFORMED Unless otherwise noted, no services have been performed at the above-referenced Property to determine Indoor Air Quality levels or to assess potential health effects from the possible presence of indoor air pollutants. Where certain Indoor Air Quality services have been performed at the Property (for example, radon testing), such services are exclusively limited to the indoor air pollutant identified and tested. Otherwise, Indoor Air Quality issues have not been addressed in a comprehensive manner, and where they have been addressed, it has been done for general informational purposes only. Homeowners and homebuyers are advised that services customarily rendered in connection with real estate transactions (for example, General Home Inspection and/or Property Condition Assessment services; Appraisals; Broker Value Opinions or Market Analyses; Mortgage Lending and Title Services; Corporate Relocation facilitation services; REALTOR® services; etc.) do not encompass comprehensive testing, analysis or evaluation of Indoor Air Quality, or specific recommendations related to Indoor Air Quality. Homeowners or homebuyers that desire comprehensive Indoor Air Quality testing or investigative services are advised to consult with contractors or professionals of their choice to ascertain the condition of the property and/or to remediate Indoor Air Quality concerns. The EPA advises the general public to check the references of outside contractors or professionals and to make certain they follow recommendations published by the EPA, the guidelines of the American Conference of Government Industrial Hygienists (ACGIH), and/or guidelines from other professional organizations. U.S. Inspect can coordinate the performance of comprehensive Indoor Air Quality testing or investigative services for additional fee(s). Services are performed by members of the U.S. Inspect Network of professional service providers.

OVERALL SUMMARY PAGE U.S. Inspect 3650 Concorde Parkway, #100 Chantilly, VA 20151-1129

CLIENT FILE# APL-441 U.S. INSPECT JOB#

3/4/2010

IM22236

CLIENT NAME

NAME OF PROPERTY OWNER/SELLER/PURCHASER

Plus Relocation Services

William Warne

CLIENT ADDRESS

ADDRESS OF PROPERTY

600 Highway 169 S, Suite 500 Minneapolis, MN 55426 CLIENT CONTACT

PRINTED DATE

3876 22nd St San Francisco, CA 94114-3204 TELEPHONE NUMBER

FAX NUMBER

HOME TELEPHONE

OFFICE TELEPHONE

Suzanne Vanacora (952) 512-5577 SCOPE OF THIS SUMMARY: ORIGINAL ASSESSMENT This summary only pertains to the first assessment that was performed on the above property. All other re-assessments will be summarized on a different summary sheet. SUMMARY ITEMS TERMITE ***ACTION REQUIRED*** Section One, Section Two items present. SEE BODY OF REPORT

Page 1 of 1 (Printed on 3/4/2010 1:41 PM)

Copyright(C) 1992-99, U.S. Inspect OSUM-1(05/23/2002)

WOOD DESTROYING PESTS AND ORGANISMS INSPECTION REPORT Building No.

Street

City

Zip

3876

22ND STREET

SAN FRANCISCO

94114

Date of Inspection

Registration # : PR4414

3469 TENNESSEE STREET #103 VALLEJO CA 94591

Escrow # :

Tel 707-674-4701 Fax 707-674-4702 Alt 707-674-4700 [email protected] Ordered by:

Property Owner and/or Party of Interest:

WILLIAM WARNE 3876 22ND STREET SAN FRANCISCO CA 94114

COMPLETE REPORT GENERAL DESCRIPTION:

X

LIMITED REPORT

SUPPLEMENTAL REPORT

3 STORY CONDOMINIUM, STUCCO/WOOD, FURNISHED & OCCUPIED

7

Report # : 14353

ESCALADE TERMITE AND REPAIR, INC

PAIGE MOREY U.S. INSPECT 3650 CONCORDE PARKWAY #100 CHANTILLY VA 20151

Number of Pages

3/3/2010

CORRECTED REPORT

Report sent to:

REINSPECTION REPORT Inspection Tag Posted:

PANTRY

667-G3

Other Tags Posted:

NONE NOTED An inspection has been made of the structure(s) shown on the diagram in accordance with the Structural Pest Control Act. Detached porches, detached steps, detached decks and any other structures not on the diagram were not inspected.

Subterranean Termites

Drywood Termites

Fungus / Dryrot

X

Other Findings

X

Further Inspection

If any of the above boxes are checked, it indicates that there were visible problems in accessible areas. Read the report for details on checked items.

Diagram Not To Scale

Front

ROBERT W. LOGAN Signature: State License No. OPR10793 Inspected By: You are entitled to obtain copies of all reports and completion notices on this property reported to the Structural Pest Control Board during the preceding two years. To obtain copies contact: Structural Pest Control Board, 2005 Evergreen Street, Suite 1500, Sacramento, California, 95815-3831. NOTE: Questions or problems concerning the above report should be directed to the manager of the company. Unresolved questions or problems with services performed may be directed to the Structural Pest Control Board at (916) 561-8708, (800) 737-8188 or www.pestboard.ca.gov. 43M-41 (Rev. 10/01)

PDF created with pdfFactory trial version www.pdffactory.com

ESCALADE TERMITE AND REPAIR, INC Page 2 of inspection report

3876

22ND STREET

SAN FRANCISCO

Address of Property Inspected

City

3/3/2010 Stamp No.

Date of Inspection

CA State

94114 Zip

14353 Co. Report No.

Escrow No.

WHAT IS A WOOD DESTROYING PEST & ORGANISM INSPECTION REPORT? READ THIS DOCUMENT. IT EXPLAINS THE SCOPE AND LIMITATIONS OF A STRUCTURAL PEST CONTROL INSPECTION AND A WOOD DESTROYING PEST & ORGANISM INSPECTION REPORT. A Wood Destroying Pest & Organism Inspection Report contains findings as to the presence or absence of evidence of wood destroying pests and organisms in visible and accessible areas and contains recommendations for correcting any infestations or infections found. The contents of Wood Destroying Pest & Organism Inspection Reports are governed by the Structural Pest Control Act and regulations. Some structures do not comply with building code requirements or may have structural, plumbing, electrical, mechanical, heating, air conditioning or other defects that do not pertain to wood destroying organisms. A Wood Destroying Pest & Organism Inspection Report does not contain information on such defects, if any, as they are not within the scope of the licenses of either this company, or it's employees. The Structural Pest Control Act requires inspection of only those areas which are visible and accessible at the time of inspection. Some areas of the structure are not accessible to inspection, such as the interior of hollow walls, spaces between floors, areas concealed by carpeting, appliances, furniture or cabinets. Infestations or infections may be active in these areas without visible and accessible evidence. If you desire information about areas that were not inspected, a further inspection may be performed at an additional cost. Carpets, furniture or appliances are not moved and windows are not opened during a routine inspection. The exterior Surface of the roof was not inspected. If you want the water tightness of the roof determined, you should contact a roofing contractor who is licensed by the Contractor's State License Board. This company does not certify or guarantee against any leakage, such as (but not limited to) plumbing, appliances, walls, doors, windows, any type of seepage, roof or deck coverings. This company renders no guarantee, whatsoever, against any infection, infestation or any other adverse condition which may exist in such areas or may become visibly evident in such area after this date. Upon request, further inspection of these areas would be performed at an additional charge. In the event damage or infestation described herein is later found to extend further than anticipated, our bid will not include such repairs. OWNER SHOULD BE AWARE OF THIS CLOSED BID WHEN CONTRACTING WITH OTHERS OR UNDERTAKING THE WORK HIMSELF/HERSELF. If requested by the person ordering this report, a re-inspection of the structure will be performed. Such requests must be within four (4) months of the date of this inspection. Every re-inspection fee amount shall not exceed the original inspection fee. Wall paper, stain, or interior painting are excluded from our contract. New wood exposed to the weather will be prime painted, only upon request at an additional expense. All pesticides and fungicides must be applied by a state certified applicator (sec. 8555 Business and Professions Code Division 3) and in accordance with the manufacturer's label requirements. This company will reinspect repairs done by others within four months of the original inspection. A charge, if any, can be no greater than the original inspection fee for each reinspection. The reinspection must be done within ten (10) working days of request. The reinspection is a visual inspection and if inspection of concealed areas is desired, inspection of work in progress will be necessary. Any guarantees must be received from parties performing repairs. “NOTICE: Reports on this structure prepared by various registered companies should list the same findings (i.e. termite infestations, termite damage, fungus damage, etc.). However, recommendations to correct these findings may vary from company to company. You have a right to seek a second opinion from another company.” This Wood Destroying Pest & Organisms Report DOES NOT INCLUDE MOLD or any mold like conditions. No reference will be made to mold or mold-like conditions. Mold is not a Wood Destroying Organism and is outside the scope of this report as defined by the Structural Pest Control Act. If you wish your property to be inspected for mold or mold like conditions, please contact the appropriate mold professional.

PDF created with pdfFactory trial version www.pdffactory.com

ESCALADE TERMITE AND REPAIR, INC Page 4 of 7 of Standard Inspection Report

3876

22ND STREET

SAN FRANCISCO

CA

City

State

Address of Property Inspected

3/3/2010 Stamp No.

94114 Zip

14353

Date of Inspection

Co. Report No.

Escrow No.

NOTE: This is a upper level unit. We are not responsible for any hidden damage. NOTES: ESCALADE TERMITE HAS A FULL SERVICE REPAIR DEPARTMENT AND TERMITE TREATMENT CREW. IN ADDITION, ESCALADE ROOFING IS AVAILABLE TO SOLVE ALL YOU'RE ROOFING NEEDS. HONESTY, RELIABILTY AND QUALITY SERVICE GUARANTEED. WE'RE NOT HAPPY UNLESS YOU ARE. ESCALADE TERMITE AND REPAIR, INC AGREEMENT PAGE IS CONFIDENTIAL AND IS NOT ALLOWED TO BE GIVEN TO OTHER PARTIES WITHOUT THE EXPRESS PERMISSION OF ESCALADE TERMITE AND REPAIR, INC. ESTIMATE GIVEN IS FOR COMPLETION OF ALL ITEMS AND IS GIVEN AT A DISCOUNT RATE. IF SINGLE ITEMS ARE TO BE COMPLETED, A NEW ESTIMATE FOR SUCH ITEM (S) WILL BE GIVEN. SECTION I ITEMS AND FURTHER INSPECTIONS MUST BE COMPLETED BEFORE WE CAN ISSUE A CLEARANCE. IF PRACTICABLE, ESCALADE WILL PERFORM REPAIRS FROM THE SUBAREA. IF IT IS NOT PRACTICABLE, AND WE NEED TO BREAK OUT STUCCO TO REMOVE AND REPLACE THE DAMAGED WOOD MEMBERS, WE WILL RE-STUCCO THE AREA. HOWEVER, WE DO NO PAINTING OR TEXTURING. DURING COURSE OF OUR REPAIRS, IF FURTHER DAMAGE IS FOUND, WE WILL ISSUE A SUPPLEMENTAL REPORT WITH FINDINGS, RECOMMENDATIONS AND ADDITIONAL COSTS. IF REPAIRS ARE PERFORMED BY OTHERS, YOU SHOULD BE AWARE IT IS ILLEGAL FOR UNLICENSED PEOPLE (WITH THE EXCEPTION OF HOMEOWNERS) TO DO WORK, EXCEEDING $500.00 ON PROPERTY BEING SOLD. PEOPLE DOING SUCH WORK SHOULD BE PREPARED TO PROVIDE COPIES OF BUILDING PERMIT(S) IF NEEDED, LICENSE NUMBERS, INSURANCE COVERAGE AND GUARANTEES TO OTHER PARTIES IN INTEREST, TO THE PROPERTY. BUYERS OF THE PROPERTY ARE ENTILED TO KNOW WHO IS DOING THE WORK, THAT THEY ARE QUALIFIED (IE. LICENSED, BONDED, INSURED, ETC) AND THEY (THE BUYERS) WILL HAVE RECOURSE IF THERE ARE PROBLEMS WITH THE WORK AFTER IT IS COMPLETED. IN ADDITION, YOU MUST CONTACT OUR OFFICE TO DETERMINE IF ANY INTERIM INSPECTIONS ARE REQUIRED BEFORE A FINAL INSPECTION CAN BE MADE. OUR RE-INSPECTIONS ARE FOR CERTIFICATION PURPOSES ONLY AND WE DO NOT ASSUME RESPONSIBILITY FOR WORK OR WORKMANSHIP OF REPAIR BEING DONE BY OTHERS. Escalade Termite and Repair cannot re-inspect and will NOT certify chemical applications performed by others. GUARANTEES:REPAIRS PERFORMED BY ESCALADE TERMITE AND REPAIR ARE GUARANTEED FOR A PERIOD OF ONE YEAR, WITH THE EXCEPTION OF RE-SEATING TOILETS, CAULKING/GROUTING, SEALING OF TUB/SHOWER ENCLOSURES AND PLUMBING ARE GUARANTEED FOR 30 DAYS ONLY. UNDER NO CIRCUMSTANCES DO WE GUARANTEE WORK COMPLETED BY OTHERS. REINSPECTION: THIS COMPANY WILL REINSPECT REPAIRS DONE BY OTHERS WITHIN FOUR MONTHS OF THE ORIGINAL INSPECTION. A CHARGE, IF ANY, CAN BE NO GREATER THAN THE ORIGINAL INSPECTION FEE FOR EACH REINSPECTION. THE REINSPECTION MUST BE DONE WIHTIN TEN (10) WORKING DAYS OF REQUEST. THE REINSPECTION IS A VISUAL INSPECTION AND IF INSPECTION OF CONCEALED AREAS IS DESIRED, INSPECTION OF WORK IN PROGRESS WILL BE NECCESSARY. ANY GUARANTEES MUST BE RECEIVED FROM PARTIES PERFORMING REPAIRS. ESCALDE TERMITE AND REPAIR CANNOT RE-INSPECT

PDF created with pdfFactory trial version www.pdffactory.com

ESCALADE TERMITE AND REPAIR, INC Page 5 of 7 of Standard Inspection Report

3876

22ND STREET

SAN FRANCISCO

CA

City

State

Address of Property Inspected

3/3/2010 Stamp No.

94114 Zip

14353

Date of Inspection

Co. Report No.

Escrow No.

AND WILL NOT CERTIFY CHEMICAL APPLICATIONS PERFORMED BY OTHERS. (REINSPECTION FEES ARE $125 PER TRIP.) THANK YOU!!!!!! "Thank you for selecting our company to perform a structural pest control inspection on your property. In accordance with the laws and regulations of the State of California, we are required to provide you and your occupants with the following information. Please take a few moments to read and become familiar with the contents below. CAUTIONS AND DISCLAIMERS: The Pest Control Industry recognizes a structure to have certain areas that are inaccessible and not inspected. These areas were not inspected by this firm. These are included but are not limited to: The water testing of second floor showers due to the covered shower pan; the water testing of bath tubs, or any plumbing; inaccessible and/or insulated attics or portions thereof due to the covering ceiling joists; attics with less than 18' clear crawl space; the interior of hollow walls or any other wooden member covered by insulation, plaster, stucco, paint, tile, sheetrock or any other material; the crawl space underneath the deck less than 12' due to limited access, covered ceiling; spaces between a floor or porch deck and the ceiling below; areas where there is no access without defacing or tearing out lumber, masonry, foliage or any other finished work; areas underneath, behind or below appliances (because we do not move appliances due to the risk of floor or finished work damage), or beneath floor coverings or furnishing (because we do not remove these items for inspection) or storage (because our inspector does not move stored items due to the risk of breakage or damage); locked areas and areas requiring an extension ladder (because our inspector does not carry an extension ladder), areas where encumbrances, storage, conditions or locks made inspection impractical; and wooden members of the subarea crawl space covered with insulation. ATTIC: A physical inspection of the attic was not performed due to possible ceiling damage. A visual inspection from the access did not reveal any infestation or infection. If the owner or interested party wishes further representation in this area, a written damage waiver will have to be received. This would be done upon request and at an additional charge. SLAB FLOOR CONSTRUCTION: Floor covering may conceal cracks in the slab that will allow infestations to enter. Infestations may be concealed by plaster, sheetrock or other wall coverings so that a diligent inspection may not uncover the true condition. In the performance of corrective measures, it may be necessary to drill into concealed areas and/or to cut or remove plants. The termite exterminator will not be liable for plumbing, heating, electrical, gas lines and equipment in or under a slab nor to plants which may be damaged during the treatments and/or repairs. GUARANTEE POLICY: This guarantee excludes structures with sub slab heating/air conditioning systems, plenum construction with air conditioning and heating duct in use, a well or cistern within fifty feet and areas that are inaccessible for treatment. Additional exclusions include structures with damage to or from excessive moisture, inadequate construction, areas of

PDF created with pdfFactory trial version www.pdffactory.com

ESCALADE TERMITE AND REPAIR, INC Page 6 of 7 of Standard Inspection Report

3876

22ND STREET

SAN FRANCISCO

CA

City

State

Address of Property Inspected

3/3/2010 Stamp No.

Date of Inspection

94114 Zip

14353 Co. Report No.

Escrow No.

inaccessibility, deteriorating materials, masonry failure, grade alteration, pipes and conduits beneath concrete slab, furnishings or contents, etc. No guarantee will be issued for any work that is a secondary recommendation or work completed by others. Guaranteed for thirty days (30 days) are any plumbing, grouting, caulking and resetting of commodes, sinks or enclosures, or any other structural repair for defects in materials or workmanship. All other work performed by this company shall be guaranteed for one year (1 year). This retreatment guarantee is limited to the reinfestations originating from the treated soil only and does not provide protection against damage to the structure or its contents by a reinfestation. Formosan termites are specifically excluded from any guarantee expressed or implied. PERMITS: We believe the work we have recommended in our inspection does not require a building permit. Our bid does not include any such cost. We will however secure all permit fees at an additional cost + the cost of permit. ROOF REPAIRS: OUR ESTIMATE DOES NOT INCLUDE ANY REPAIRS TO ROOF COVERING. DURING REPAIRS, IF WE DISTURB THE ROOF, WE WILL REPAPER ONLY. WE RECOMMEND OWNER TO HIRE ROOFER FOR ANY ROOF REPAIRS. IN THE EVENT ANY TILE IS BROKEN, IT WILL BE THE OWNER'S RESPONSIBILITY TO HIRE ROOFER TO INSTALL NEW TILE AT OWNER'S EXPENSE. RECENTLY PAINTED STRUCTURE: PORTIONS OF THE BUILDING APPEAR TO HAVE BEEN RECENTLY PAINTED. OUR FIRM DOES NOT PROBE FINISHED AREAS AND IS NOT RESPONSIBLE FOR ANY ADVERSE CONDITIONS CONCEALED BY PAINT. STATE LAW REQUIRES THAT YOU BE GIVEN THE FOLLOWING INFORMATION: ""CAUTION - PESTICIDES ARE TOXIC CHEMICALS. Structural Pest Control Operators are licensed and regulated by the Structural Pest control Board, and apply pesticides which are registered and approved for use by the California Department of Food and Agriculture and the United States Environmental Protection Agency. Registration is granted when the state finds that based on scientific evidence, there are no appreciable risks weighted by the benefits. The degree of risk depends on the degree of exposure, so exposure should be minimized."" ""If within 24 hours following application, you experience symptoms similar to common seasonal illness comparable to the flu, contact your physician or poison control center and your pest control operator immediately."" For further information contact any of the following: County Health Department- Alameda 510-567-6700 Marin 415-499-3696 Placer 530-889-4000 San Francisco 415-554-2770 Santa Clara 408-918-3400 Sonoma 707-565-4700

Contra Costa 925-646-5225 Napa 707-253-4471 Sacramento 916-875-8440 San Mateo - 650-363-4305 Solano 707-421-6765 Yolo 530-666-8646

County Poison Control Center - 800-764-7661 OR 800-342-9293

PDF created with pdfFactory trial version www.pdffactory.com

ESCALADE TERMITE AND REPAIR, INC Page 7 of 7 of Standard Inspection Report

3876

22ND STREET

SAN FRANCISCO

CA

City

State

Address of Property Inspected

3/3/2010 Stamp No.

94114 Zip

14353

Date of Inspection

Co. Report No.

County Agricultural Commissioner - Alameda 510-670-5232 Marin 415-499-6700 Placer 530-889-7372 San Francisco 415-285-5010 Santa Clara 408-918-4600 Sonoma 707-565-2371

Escrow No.

Contra Costa 925-646-5250 Napa 707-253-4357 Sacramento 916-654-0466 San Mateo 650-363-4700 Solano 707-421-7465 Yolo 530-666-8140

Structural Pest Control Board - 916-263-2540 IF WE HAVE RECOMMENDED THE USE OF A FUNGICIDE WE WILL USE: * TIMBOR (DISODIUM OCTABORATE TETRAHYDRATE) IF WE HAVE RECOMMENDED THE TREATMENT OF SUBTERRANEAN TERMITES WE WILL USE: * DRAGNET SFR (PERMETHRIN) OR * PREMISE 75 (IMIDACLOPRID) OR * TERMIDOR SC (FIPRONIL) CONSUMER NOTICE: There may be health related implications associated with the findings reflected on this report. We are not qualified to render any opinion concerning any such health implications, and no such opinion is expressed. The inspection reflected by this report was limited to visible and accessible surfaces only; we are not qualified to render any opinion as to indoor air quality, and no such opinion is expressed. Any questions concerning any health related implications which may be associated with the findings or recommendations (including recommendations for structural repairs) that are reflected in this report, or concerning indoor air quality, should be directed to a qualified professional. MOLD DISCLAIMER: There may be health implications associated with the structural repairs reflected in the attached Work Authorization Contract. These health implications include, but are not necessarily limited to, the possible release of mold spores during the course of structural repairs which under certain circumstances may require that the repair work be performed with precautions such as containment barriers and negative air pressure which this company is not qualified to perform and does not perform. We are not qualified to render any opinion concerning any such health implications or concerning the necessity of any such precautions, and no such opinion is expressed. Any questions concerning any health related implications which may be associated with the structural repairs reflected in the attached Work Authorization Contract or concerning any necessary precautions to be taken prior to or during repairs should be directed to a qualified professional before any repairs are undertaken.

PDF created with pdfFactory trial version www.pdffactory.com

ESCALADE TERMITE AND REPAIR, INC 3469 TENNESSEE STREET #103 VALLEJO CA 94591 Tel 707-674-4701 Fax 707-674-4702 Alt 707-674-4700 [email protected]

AGREEMENT Report #: 14353

No work will be performed until a signed copy of this agreement has been received. Address of Property: City: State/Zip:

3876 22ND STREET SAN FRANCISCO 94114 CA

The inspection report of the company dated,

3/3/2010

is incorporated herein by reference as though fully set forth.

The company is authorized to proceed with the work outlined in the items circled below from the Termite Inspection Report for the property inspected, for a total sum of $ ________________________ . Work will be scheduled upon receipt of 50% downpayment. The remaining balance to be paid upon completion of repair work and/or chemical application.

THE COM PANY AGREES To guarantee all repai r c om pleted by this com pany for one year from date of com pletion except for caul king, grouting or plumbing, whic h is guaranteed for a period of Thi rty (30) days. W e assume no responsibility for work perform ed by others, to be bound to perform this w ork for the price quoted in our cost breakdow n for a period not to ex ceed 30 days, to use reas on able c are in t he perform anc e of our work but to assum e no responsibility for dam age to any hi dden pipes, w iring, or other facilities or to any shrubs , pl ants or roof. THE OW NER OR OWN ER'S AGENT AGREES To pay for services rendered in an y additional services r equested upon c ompl etion of w ork to pay a s ervice charg e of on e and one-hal f perc ent (1 1/2%) interest per m onth, or porti on of any m onth, an nu al interest rate of eighteen percent (18%) on acc ounts exceedi ng the ten (10) day full paym ent schedule. Th e Ow ner grants to The Company a s ec urity interest in the pr operty to sec ure payment sum for w or k and ins pection fee completed. In case of n on-paym ent by Th e Own er, reasonable attorney fees and costs of collec tion s hall be paid by owner, w hether suit b e fil ed or not. ALL PARTIES AGREE If any additional work is deem ed nec essary by the loc al buildin g ins pector, said w ork w ill not be perform ed without additi on al authorization fr om owner or ow ner's agent. This c ontract price does not include the charge of an y Insp ec ti on Report fees. Circl e the item s you wish perform ed by The Company, bel ow and enter total am ount above: NOTICE TO OWNER Under the C alifornia Mec hanic s Lien Law any structural pest control company w hich contracts to d o w ork for you, any contractor, subcontr actor, l abor er, supplier or other pers on who helps to improv e y our property, but is not p aid for his or her work or supplies, has a ri ght to enforce a claim against your property. This m eans that after a c ou rt hearing, your property c ould be sold by a court officer and the p roc eeds of the sale used to s atisfy th e indebtednes s. This c an happen even if you have pai d your structur al pest c ontrol company in full if the subc ontractor, labor er s or suppliers rem ain u np aid. To preserve th eir right to fil e a claim or li en against y our property, c ertain claim ants such as subcontractors or m aterial suppliers are r equired to provide you w ith a docum ent entitl ed "Preliminary N otice.” Prim e contractors and laborers for w ages do n ot have to prov ide this notic e. A Prelim inary Notice is not a lien ag ainst your property. Its purpose is to notify you of pers ons w ho m ay have a right to file a li en against you r property if th ey are not p aid.

ITEMS

Further Prefix Section 1 Section 2 Inspection Others -----------------------------------------------------3A 1,275.00 3B Others 3C Others 3D Others 4B Plumber

-----------------------------------------------------Total: 1,275.00

Property Owner:

Date:

Owner's Agent:

Date:

Inspected By:

PDF created with pdfFactory trial version www.pdffactory.com

Grand:

1,275.00

Date:

Indoor Air Quality Disclaimer GENERAL BACKGROUND ON INDOOR AIR QUALITY In the last several years, a growing body of scientific evidence has indicated that the air within homes and other buildings can be more seriously polluted than the outdoor air in even the largest and most industrialized cities. Other research indicates that people spend approximately 90 percent of their time indoors. Thus, for many people, the risks to health may be greater due to exposure to air pollution indoors than outdoors. In addition, people who may be exposed to indoor air pollutants for the longest periods of time are often those most susceptible to the effects of indoor air pollution. Such groups include the young, the elderly, and the chronically ill, especially those suffering from respiratory or cardiovascular disease. While pollutant levels from individual sources may not pose a significant health risk by themselves, most homes have more than one source that contributes to indoor air pollution. There can be a serious risk from the cumulative effects of these sources. Fortunately, there are steps that most people can take both to reduce the risk from existing sources and to prevent new problems from occurring. The U.S. Environmental Protection Agency (EPA) and the U.S. Consumer Product Safety Commission (CPSC) produce a popular and comprehensive publication on the subject of Indoor Air Quality entitled The Inside Story: A Guide to Indoor Air Quality. It describes sources of air pollution in the home and office, corrective strategies, and specific measures for reducing pollutant levels. This illustrated booklet covers all major sources of pollution such as biological contaminants (including bacteria, molds, mildew, viruses, animal dander and cat saliva, house dust mites, cockroaches, and pollen), radon, household chemicals, carbon monoxide, formaldehyde, pesticides, asbestos, and lead. U.S. Inspect advises homebuyers and homeowners to research Indoor Air Quality issues through resources available at the federal, state and/or local government levels. The EPA website at www.epa.gov is an informative resource for information on Indoor Air Quality. For individuals without access to the Internet, federal agencies with Indoor Air Quality information include the EPA's Indoor Air Quality Information Clearinghouse (IAQ INFO) at P.O. Box 37133, Washington, DC, 20013-7133; (800) 438-4318; (703) 356-4020. Single copies of The Inside Story: A Guide to Indoor Air Quality are available from EPA's IAQ Information Clearinghouse or by visiting the EPA website at www.epa.gov/iaq/pubs/ (the website is recommended for the most up-to-date scientific and technical information). Questions or concerns about Indoor Air Quality issues can also be answered by a variety of state or local government agencies. Calling or writing the agencies responsible for health or air quality control is the best way to start getting information from a state or local government agency. To obtain state agency contacts, individuals can write, call or visit EPA's IAQ Information Clearinghouse. Unless otherwise noted, no services have been performed at the above-referenced Property to determine Indoor Air Quality levels or to assess potential health effects from the possible presence of indoor air pollutants. Where certain Indoor Air Quality services have been performed at the Property (for example, radon testing), such services are exclusively limited to the indoor air pollutant identified and tested. Otherwise, Indoor Air Quality issues have not been addressed in a comprehensive manner, and where they have been addressed, it has been done for general informational purposes only. Homeowners and homebuyers are advised that services customarily rendered in connection with real estate transactions (for example, General Home Inspection and/or Property Condition Assessment services; Appraisals; Broker Value Opinions or Market Analyses; Mortgage Lending and Title Services; Corporate Relocation facilitation services; REALTOR(r) services; etc.) do not encompass comprehensive testing, analysis or evaluation of Indoor Air Quality, or specific recommendations related to Indoor Air Quality. Homeowners or homebuyers that desire comprehensive Indoor Air Quality testing or investigative services are advised to consult with contractors or professionals of their choice to ascertain the condition of the property and/or to remediate Indoor Air Quality concerns. The EPA advises the general public to check the references of outside contractors or professionals and to make certain they follow recommendations published by the EPA, the guidelines of the American Conference of Government Industrial Hygienists (ACGIH), and/or guidelines from other professional organizations. U.S. Inspect can coordinate the performance of comprehensive Indoor Air Quality testing or investigative services for additional fee(s). Services are performed by members of the U.S. Inspect Network of professional service providers.

RELOCATION PROPERTY ASSESSMENT Client: PLUS RELOCATION SERVICES Client File #: APL-441 Contact: SUZANNE VANACORA 3876 22ND ST Homeowner: WILLIAM WARNE SAN FRANCISCO, CA 94114-3204 U.S. Inspect Job #: IM32407 Page 1 of 10 RPA Photograph Pages / PAP and Client Disclaimers - © 2008, U.S. Inspect, LLC. All Rights Reserved. Rev. 2/19/2010 THIS DOCUMENT IS NOT INTENDED FOR USE NOR IS IT TO BE RELIED UPON BY ANY PARTY OTHER THAN THE CLIENT

Worldwide ERC® Relocation Property Assessment IMPORTANT INFORMATION: Please Read Carefully This document is a Property Assessment. It is not a buyer’s home inspection. This document should not be used in place of nor be mistaken for a general home inspection or specialty type inspection performed by a licensed or trades professional (e.g., professional home inspector, engineer, pest control operator, electrician, plumber, roofer or HVAC specialist, pool/spa specialist, etc.). This Property Assessment was prepared exclusively and for the sole use of the Client identified below (the "Client") under an established business-to-business relationship for the specific purposes of assisting with the relocation of an employee. It is not intended for use, nor is it to be relied upon, by any party other than the Client, including, but not limited to, buyers, sellers, lenders, real estate brokers/agents, and/or appraisers. The Client may be required to provide this Property Assessment to other parties in order to comply with disclosure obligations under applicable federal, state and/or local law(s); however, no disclosure of this Property Assessment to other parties, including prospective buyers, shall be deemed to create or give rise to a duty of care or performance on the part of the Property Assessment Provider identified below or the Client toward such other parties. Accordingly, no party other than the Client may rely upon or be influenced by this Property Assessment when considering the property. The Property Assessment Provider prepared this Property Assessment in accordance with Client directives and based it on findings gathered at the property address identified below and other property information sources.

1. GENERAL INFORMATION File #: APL-441

Client: PLUS RELOCATION SERVICES Phone: (952) 512-5577

Contact: SUZANNE VANACORA

Fax:

Email Address: Client Address: 600 HIGHWAY 169 S, SUITE 500 City/State/Postal Code: MINNEAPOLIS, MN 55426 Transferee(s): WILLIAM WARNE Transferee Property Address: 3876 22ND ST City/State/Postal Code: SAN FRANCISCO, CA 94114-3204 Job/File #: IM32407

Property Assessment Provider: U.S. INSPECT Provider Address: 3650 CONCORDE PARKWAY SUITE 100 City/State/Postal Code: CHANTILLY, VA 20151-1129 Contact: U.S. INSPECT

Phone: (703) 293-1400 Fax:

Email Address: Date: 3/2/2010

Time: 10:45

Weather: RAIN.

Parties Present At Time of Assessment: AGENT.

Temp: 55

Estimated Age of Main Dwelling (yrs): 110

Occupied:

Yes

No

Scope of Assessment: RELOCATION PROPERTY ASSESSMENT.

RELOCATION PROPERTY ASSESSMENT Client:

Page 2 of 10

PLUS RELOCATION SERVICES

Client File #: APL-441

© 2008, Worldwide ERC® Rev. 2/19/2010 THIS DOCUMENT IS NOT INTENDED FOR USE NOR IS IT TO BE RELIED UPON BY ANY PARTY OTHER THAN THE CLIENT

2. PURPOSE AND SCOPE OF THE RELOCATION PROPERTY ASSESSMENT To provide a professional opinion of a relocating employee’s main dwelling and its immediate surrounding area in its "as is" condition, as of the date of assessment, limited to the definitions and guidelines as established by the Client and within this Property Assessment document.

3. OBJECTIVE OF THE RELOCATION PROPERTY ASSESSMENT To provide the Client with data about a relocating employee’s main dwelling and its immediate surrounding area, based on a visual assessment of items identified by category in this Property Assessment document.

4. DEFINITION OF THE RELOCATION PROPERTY ASSESSMENT A visual, non-invasive evaluation and status of the items identified by category on the ensuing pages. The reporting of apparent defects (not cosmetic deficiencies) that call for corrective action is limited to three categories: 1) structure; 2) unsafe or hazardous conditions; and 3) inoperative systems or appliances. 1. Structure: A load-bearing member of a building (including, but not limited to, footings, foundation walls, posts, beams, floor joists, bearing walls, or roof framings) is to be reported as defective if it has one or more of these characteristics: Abnormal cracking or splitting; Unusual settlement; Deterioration such as rot or pest infestation damage; Improper alignment or structural integrity compromised by modification or abuse; or Other characteristics that affect the building’s structural integrity. 2. Unsafe or Hazardous Conditions: Any item that is identified as a safety defect or a hazard, the presence or absence of which would be dangerous. Unless directed by the Client, the reporting of the possible presence of lead based paint, asbestos, ureaformaldehyde foam insulation, radon, electromagnetic radiation, toxic wastes, molds or fungus, and other environmental or indoor air pollutants are outside the scope of this Property Assessment. 3. Inoperative Systems and Appliances: Any installed systems or built-in appliances that do not operate properly or perform their intended function in response to normal use. Unless directed by the Client, the following areas are outside the scope of this assessment: (i) cosmetic deficiencies; (ii) deferred maintenance items; (iii) the condition of on-site waste and water systems; (iv) the condition of underground fuel storage tanks; (v) the quality of the water supply; (vi) geological hazards such as floods, erosion, earthquakes, landslides, mudslides and volcanoes; and (vii) governmental or lender requirements. Furthermore, this Property Assessment is not a representation of compliance or noncompliance with federal, state, or local government regulations and codes (e.g., building codes, zoning ordinances, energy efficiency ratings, addition or remodeling permits, etc.). Estimated costs to correct items identified in this Property Assessment as defective and/or items that may require attention are not bids and do not give rise to performance obligations on the part of the Property Assessment Provider. The Property Assessment Provider is not engaged in the business of providing repair; renovation or improvement services; as such, the Property Assessment Provider has not and cannot determine the actual cost of any repairs, renovations or improvements that may be advised or desired. The cost estimates reflect national, state and/or local cost averages as derived from the review of cost estimator manuals and other information sources by the Property Assessment Provider; all cost estimates should be followed by firm quotes or bids from qualified, reputable contractors.

RELOCATION PROPERTY ASSESSMENT Client:

Page 3 of 10

PLUS RELOCATION SERVICES

Client File #: APL-441

© 2008, Worldwide ERC® Rev. 2/19/2010 THIS DOCUMENT IS NOT INTENDED FOR USE NOR IS IT TO BE RELIED UPON BY ANY PARTY OTHER THAN THE CLIENT

5. STATUS DEFINITIONS For each category, when applicable, rate the status of each item by checking the box as follows: = Acceptable: The item is performing its intended function as of the date of the assessment. = Not Present: The item does not exist in the structure being assessed. = Not Assessed: The item was not assessed because of inaccessibility or seasonal impediments. = Defective: The item is either: structurally unsound; unsafe or hazardous; or inoperative, as defi ned in Section 4 above.

A NP NA D

Item

Remarks

LOTS & GROUNDS (LG) 1 2 3 4

5 6 7 8 9 10 11 12

Walks Stoops Steps Patio Deck Balcony 1. DETERIORATED DECKING BOARDS OBSERVED AT THE LOWER REAR DECK. 2. DETERIORATED FRAMING MEMBERS OBSERVED AT THE REAR BALCONY. Porch Retaining Walls SURFACE WATER CONTROL Grading Swales Bsmt Stairwell Drain Window Wells Exterior Surface Drain

ROOF (R) 1 2 3 4 5 6 7

8 9 10 11 12

Method of Assessment LADDER AGAINST EAVES. #1 MAIN ROOF. Approx. Age: UNKNOWN. Design Life: THE ASSESSOR WAS UNABLE TO ACCESS THE MAIN ROOF DUE TO HEIGHT/DESIGN. #2 SUN ROOM ROOF. FLAT ROOF. Approx. Age: 5 YRS. Design Life: 10-15 YRS. #3 Approx. Age: Design Life: #4 Approx. Age: Design Life: #5 Approx. Age: Design Life: Flashing THE ASSESSOR WAS UNABLE TO EVALUATE THE FLASHINGS WITHIN THE MAIN ROOFING SYSTEM DUE TO HEIGHT/DESIGN. Skylights Chimney THE ASSESSOR WAS UNABLE TO FULLY EVALUATE THE CHIMNEY SYSTEM DUE TO HEIGHT/DESIGN. ROOF WATER CONTROL Gutters Downspouts And Extens

RELOCATION PROPERTY ASSESSMENT Client:

Page 4 of 10

PLUS RELOCATION SERVICES

Client File #: APL-441

© 2008, Worldwide ERC® Rev. 2/19/2010 THIS DOCUMENT IS NOT INTENDED FOR USE NOR IS IT TO BE RELIED UPON BY ANY PARTY OTHER THAN THE CLIENT

A NP NA D

Item

Remarks

EXTERIOR SURFACE (ES) 1

2 3 4 5 6 7

#1 THE ASSESSOR WAS UNABLE TO DETERMINE THE TYPE OF CLADDING PRESENT WITHOUT THE USE OF INVASIVE MEANS. WE SUGGEST TWO OPTIONS; CONTACT THE BUILDER FOR DOCUMENTATION REGARDING THE STUCCO APPLICATION OR; HAVE THE STUCCO CLADDING EVALUATED BY INVASIVE MEANS BY A QUALIFIED STUCCO CONTRACTOR TO MAKE AN ACCURATE DETERMINATION OF THE TYPE OF CLADDING THAT IS PRESENT. IF THE STUCCO SYSTEM IS DETERMINED TO BE EIFS IT SHOULD BE EVALUATED, INCLUDING MOISTURE TESTING, BY A STUCCO CONTRACTOR. #2 REAL WOOD. #3 Trim Fascia Soffits Windows 1. DETERIORATION OBSERVED AT THE WINDOWS LOCATED IN THE DINING ROOM, AT THE TWIN BEDROOM AND AT THE REGULAR BEDROOM. 2. MISSING AND DAMAGED HARDWARE OBSERVED AT THE LIVING ROOM (FIVE UNITS), AT THE SECOND BEDROOM (ONE UNIT) AND ONE UNIT AT THE KITCHEN. THE WINDOWS HAVE EITHER NO SEAT/LOCK OR HAVE DAMAGED COUNTER BALANCE DEVICES.

GARAGE/CARPORTS (G/C) 1 2

3

Garage Carport Attached Detached Door Operation Auto Door Opener IMPROPERLY OPERATING AUTO DOOR OPENER SYSTEM. THE OPENER DOOR BRACKET POPED OFF THE TRACK PULLEY BLOCK WHEN THE PRESSURE TEST FOR THE REVERSING MECHANISM WAS PERFORMED. Condition 1. A BREACH IS PRESENT IN THE FIRE-RATED CEILING INSIDE THE GARAGE (AT THE AREA OF PREVIOUS REPAIRS/PATCH-WORK). 2. SETTLEMENT OBSERVED IN THE SLAB ALONG THE RIGHT SIDE OF THE GARAGE. 3. STANDING WATER OBSERVED ALONG THE LEFT SIDE WALL IN THE GARAGE LOCATED ON THE BASEMENT LEVEL (AT/UNDER AND AROUND THE AREA OF THE WATER HEATERS). 4. MISSING FIRE-RATED CHASE FOR THE HVAC FLEX DUCTS THAT RUN THROUGHOUT THE GARAGE. THE FLEX DUCT CASING CAN NOT MAINTAIN THE REQUIRED ONE HOUR FIRE-RATING. IF THE DUCT WERE TO BECOME COMPROMISED BY FIRE, IT COULD SPREAD THROUGH THE DUCT SYSTEM TO OTHER LOCATIONS IN THE DWELLING.

STRUCTURE (S) 1

2 3 4 5 6 7

Foundation DETERIORATED (MISSING SECTIONS OF MORTAR) SECTIONS OF MORTAR OBSERVED BETWEEN THE BRICK SILL AT THE RIGHT SIDE OF THE DWELLING. Beams FINISHED AREA LIMITED VISIBILITY - NO APPARENT PROBLEMS. Bearing Walls FINISHED AREA LIMITED VISIBILITY - NO APPARENT PROBLEMS. Joists Trusses FINISHED AREA LIMITED VISIBILITY - NO APPARENT PROBLEMS. Piers Posts FINISHED AREA LIMITED VISIBILITY - NO APPARENT PROBLEMS. Floor Slab FINISHED AREA LIMITED VISIBILITY - NO APPARENT PROBLEMS. Hand Rails LATTICE IS BEING USED IN PLACE OF BALUSTERS IN THE GUARDRAILS AT THE BALCONY.

ATTIC (A) 1 2 3 4 5 6 7

Method of Assessment VIEWED FROM FINISHED AREA DUE TO DESIGN. Roof Framing FINISHED AREA LIMITED VISIBILITY - NO APPARENT PROBLEMS. Sheathing FINISHED AREA LIMITED VISIBILITY - NO APPARENT PROBLEMS. Ventilation Attic Fan Whole House Fan Evidence of ongoing water penetration? Yes No If Yes, describe:

RELOCATION PROPERTY ASSESSMENT Client:

Page 5 of 10

PLUS RELOCATION SERVICES

Client File #: APL-441

© 2008, Worldwide ERC® Rev. 2/19/2010 THIS DOCUMENT IS NOT INTENDED FOR USE NOR IS IT TO BE RELIED UPON BY ANY PARTY OTHER THAN THE CLIENT

A NP NA D

Item

Remarks

BASEMENT (B) 1 2 3 4

Sump Pump Floor Heat Evidence of ongoing water penetration? Yes No If Yes, describe: STANDING WATER OBSERVED ALONG THE LEFT SIDE WALL IN THE GARAGE LOCATED ON THE BASEMENT LEVEL (AT/UNDER AND AROUND THE AREA OF THE WATER HEATERS).

CRAWL SPACE (CS) NOT APPLICABLE

ELECTRICAL (E) 1 2 3 4 5 6 7 8 9

Amps: 75. Volts: 120/240. Service Cable Panel RUST OBSERVED INSIDE THE SERVICE PANEL BOX AT THE EXTERIOR OF THE DWELLING. Branch Circuits Ground UNABLE TO TRACE. Wire Conductor GFI Smoke Detector Is the size of the incoming electrical service adequate to meet the needs of the dwelling? Yes No THE ASSESSOR WAS UNABLE TO DETERMINE THE ADEQUACY OF THE 75 AMP ELECTRICAL SERVICE.

HEATING SYSTEM (HS) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

Primary: WARM AIR FURNACE. Additional: Fuel(s): Primary Operation Additional Operation Draft Control Exhaust System Distribution Fuel Tanks/Lines Thermostat Blower Humidifier Heat Exchanger Pressure Rel Valve Circulator Pump

Approx. Age: 10 YRS. Approx. Age:

Design Life: 15-35 YRS. Design Life:

GAS.

GAS LINES.

ORANGE FLAME IS PRESENT WITHIN THE BLUE FLAMES AT THE BURNERS.

AIR CONDITIONING SYSTEM (AC) NOT APPLICABLE

RELOCATION PROPERTY ASSESSMENT Client:

Page 6 of 10

PLUS RELOCATION SERVICES

Client File #: APL-441

© 2008, Worldwide ERC® Rev. 2/19/2010 THIS DOCUMENT IS NOT INTENDED FOR USE NOR IS IT TO BE RELIED UPON BY ANY PARTY OTHER THAN THE CLIENT

A NP NA D

Item

Remarks

PLUMBING (P) 1 2 3 4 5 6 7 8 9 10 11 12 13 14

15 16

Water Source: Public Private How Verified? VISUAL. Sewage Service: Public Private How Verified? VISUAL. Water Service On? Yes No Water Pipes Drain Pipes IMPROPERLY OPERATING DRAIN LINES FOR THE SINKS IN BOTH HALL BATHROOMS. Vent Pipes Laundry Tub Water Pressure Toilet Tub Shower CRACKED/FAILED GROUT OBSERVED AT THE TUB APRON IN THE FIRST BATHROOM. Exhaust Fan Sink WATER HEATER: Approx. Age: 12 YRS. Design Life: 10-15 YRS. Water Heater Unit 1. RUST OBSERVED ON THE WATER HEATER. ADDITIONALLY, THE WATER HEATER IS RESTING IN STANDING WATER. 2. INADEQUATE SEISMIC BRACING OBSERVED AT THE WATER HEATER. SEISMIC BRACING IS NECESSARY TO STABILIZE THE WATER HEATER IN THE EVENT OF AN EARTHQUAKE. Exhaust System Temp Press Relief Valve

ON-SITE SEWAGE DISPOSAL (SD) NOT APPLICABLE

WELL (W) NOT APPLICABLE

POOL AND HOT TUB (P/T) NOT APPLICABLE

FIREPLACE/WOODBURNING DEVICES (FP) 1 2 3 4

Fireplace Free Standing Stove Fireplace Insert Flue THE ASSESSOR WAS UNABLE TO FULLY EVALUATE THE FLUE PASSAGE WITHIN THE CHIMNEY DUE TO HEIGHT/DESIGN.

KITCHEN (K) 1 2 3 4 5

Cooking Appliances Disposal Dishwasher Ventilator Other Built Ins

FINAL COMMENTS During this property assessment, have you observed other unsafe or hazardous conditions as defined on page 1 of this report? If yes, explain:

The Property Assessment Provider identified below hereby certifies adherence to the terms of the assignment as set forth in the Definitions.

Property Assessment Provider Name(Please print or type): RELOCATION PROPERTY ASSESSMENT Client: PLUS RELOCATION SERVICES

Page 7 of 10

Date: Client File #: APL-441

© 2008, Worldwide ERC® Rev. 2/19/2010 THIS DOCUMENT IS NOT INTENDED FOR USE NOR IS IT TO BE RELIED UPON BY ANY PARTY OTHER THAN THE CLIENT

Relocation Property Assessment Picture Page

1. FRONT VIEW (G)

2. REAR VIEW (G)

3. DETERIORATED JOISTS UNDER THE BALCONY (LG)

4. BALCONY (LG)

5. FLAT ROOF VIEW (R)

6. CHIMNEY VIEW (R)

RELOCATION PROPERTY ASSESSMENT Client: PLUS RELOCATION SERVICES Client File #: APL-441 Contact: SUZANNE VANACORA 3876 22ND ST Homeowner: WILLIAM WARNE SAN FRANCISCO, CA 94114-3204 U.S. Inspect Job #: IM32407 Page 8 of 10 RPA Photograph Pages / PAP and Client Disclaimers - © 2008, U.S. Inspect, LLC. All Rights Reserved. Rev. 2/19/2010 THIS DOCUMENT IS NOT INTENDED FOR USE NOR IS IT TO BE RELIED UPON BY ANY PARTY OTHER THAN THE CLIENT

Relocation Property Assessment Picture Page

7. SETTLED GARAGE FLOOR/SLAB (G/C)

8. BREACH IN THE FIRE-RATED CEILING (G/C)

9. LATTICE USED AS A GUARDRAILS SYSTEM (S)

10. DETERIORATED MORTAR IN THE BRICK SILL (S)

11. STANDING WATER AT THE BASE OF THE WATER HEATER (B)

12. WATER ON THE BASEMENT FLOOR (B)

RELOCATION PROPERTY ASSESSMENT Client: PLUS RELOCATION SERVICES Client File #: APL-441 Contact: SUZANNE VANACORA 3876 22ND ST Homeowner: WILLIAM WARNE SAN FRANCISCO, CA 94114-3204 U.S. Inspect Job #: IM32407 Page 9 of 10 RPA Photograph Pages / PAP and Client Disclaimers - © 2008, U.S. Inspect, LLC. All Rights Reserved. Rev. 2/19/2010 THIS DOCUMENT IS NOT INTENDED FOR USE NOR IS IT TO BE RELIED UPON BY ANY PARTY OTHER THAN THE CLIENT

Relocation Property Assessment Picture Page

13. BASEMENT LEVEL (B)

14. RUST INSIDE THE PANEL BOX (E)

15. FURNACE (HS)

16. WATER HEATER - INADEQUATE SEISMIC BRACING (P)

17. FIREPLACE (FP)

RELOCATION PROPERTY ASSESSMENT Client: PLUS RELOCATION SERVICES Client File #: APL-441 Contact: SUZANNE VANACORA 3876 22ND ST Homeowner: WILLIAM WARNE SAN FRANCISCO, CA 94114-3204 U.S. Inspect Job #: IM32407 Page 10 of 10 RPA Photograph Pages / PAP and Client Disclaimers - © 2008, U.S. Inspect, LLC. All Rights Reserved. Rev. 2/19/2010 THIS DOCUMENT IS NOT INTENDED FOR USE NOR IS IT TO BE RELIED UPON BY ANY PARTY OTHER THAN THE CLIENT

RELOCATION PROPERTY ASSESSMENT SUMMARY/COST ESTIMATE Record on this summary page the corrective action(s) required for all items determined to be defective, including the estimated cost of repairs, and explain any items reported as "Not Assessed." As noted in Section 4 above, these estimates are not bids, nor intended to be used as such.

SECTION

REMARKS

ESTIMATED COSTS*

NOT ASSESSED ITEMS: ROOF: CHIMNEY PROB: THE ASSESSOR WAS UNABLE TO FULLY EVALUATE THE CHIMNEY SYSTEM DUE TO HEIGHT/DESIGN. SOLU: FURTHER EVALUATION NEEDED BY A CHIMNEY SPECIALIST. EXTERIOR SURFACE: SURFACE 1 PROB: THE ASSESSOR WAS UNABLE TO DETERMINE THE TYPE OF CLADDING PRESENT WITHOUT THE USE OF INVASIVE MEANS. WE SUGGEST TWO OPTIONS; CONTACT THE BUILDER FOR DOCUMENTATION REGARDING THE STUCCO APPLICATION OR; HAVE THE STUCCO CLADDING EVALUATED BY INVASIVE MEANS BY A QUALIFIED STUCCO CONTRACTOR TO MAKE AN ACCURATE DETERMINATION OF THE TYPE OF CLADDING THAT IS PRESENT. IF THE STUCCO SYSTEM IS DETERMINED TO BE EIFS IT SHOULD BE EVALUATED, INCLUDING MOISTURE TESTING, BY A STUCCO CONTRACTOR. ELECTRICAL: GROUND PROB: UNABLE TO TRACE. FIREPLACE/ WOODBURNING DEVICES: FLUE PROB: THE ASSESSOR WAS UNABLE TO FULLY EVALUATE THE FLUE PASSAGE WITHIN THE CHIMNEY DUE TO HEIGHT/DESIGN. SOLU: FURTHER EVALUATION NEEDED BY A CHIMNEY SPECIALIST.

Total Estimated Cost * Estimated costs to correct items identified in this Property Assessment as defective and/or items that may require attention are not bids and do not give rise to performance obligations on the part of the Property Assessment Provider. Not provided in localities where prohibited. RELOCATION PROPERTY ASSESSMENT Client:

PLUS RELOCATION SERVICES

Client File #: APL-441

Homeowner: WILLIAM WARNE Summary Page 4 of 6 © 2008, Worldwide ERC® Rev. 2/19/2010 THIS DOCUMENT IS NOT INTENDED FOR USE NOR IS IT TO BE RELIED UPON BY ANY PARTY OTHER THAN THE CLIENT

RELOCATION PROPERTY ASSESSMENT SUMMARY/COST ESTIMATE Record on this summary page the corrective action(s) required for all items determined to be defective, including the estimated cost of repairs, and explain any items reported as "Not Assessed." As noted in Section 4 above, these estimates are not bids, nor intended to be used as such.

SECTION

REMARKS

ESTIMATED COSTS*

U.S. Inspect, LLC recommends that all repairs be performed by a qualified contractor.

Total Estimated Cost * Estimated costs to correct items identified in this Property Assessment as defective and/or items that may require attention are not bids and do not give rise to performance obligations on the part of the Property Assessment Provider. Not provided in localities where prohibited. RELOCATION PROPERTY ASSESSMENT Client:

PLUS RELOCATION SERVICES

Client File #: APL-441

Homeowner: WILLIAM WARNE Summary Page 6 of 6 © 2008, Worldwide ERC® Rev. 2/19/2010 THIS DOCUMENT IS NOT INTENDED FOR USE NOR IS IT TO BE RELIED UPON BY ANY PARTY OTHER THAN THE CLIENT

Page 1 of 15



U.S. Inspect Structural Evaluation Date: April 12, 2010 U.S. Inspect™ 3650 Concorde Parkway, Suite 100 Chantilly, VA 20151-1129 Re: Homeowner: Client:

U.S. Inspect™ Job #: IM40533 U.S. Inspect™ File #: APL-441 Property Address: 3876 22nd Street San Francisco, CA 94114

Structural Evaluation Mr. William Warne Plus Relocation

Engineer’s Name: Willard Decker, P.E. Phone Number: (408) 885-1599 Engineering Company: Criterium-Decker Engineers Company File Number: S10-963 Date of Evaluation:

April 8, 2010

Time:

9:00 am

Weather Conditions:

Clear & sunny

Age of Home:

120

Have there been additions/modifications:

Temperature: 65 deg. F Yes-Back Deck

Have permits been secured for additions/modifications: How was this information verified: Was property occupied:

Unknown

N/A

Yes

People Present: William Warne At your request, an “as is” Structural Evaluation of the above property was performed. The evaluation was performed and report prepared in accordance with USInspect’s instructions. The report is in the format you have requested. PURPOSE OF THIS STRUCTURAL EVALUATION To assist our Client in arriving at a fair determination of value by providing an opinion as to the current structural condition and identifying observable structural defects.

2 SCOPE OF THE EVALUATION Structural Engineers shall: • • • • • •

Provide a structural description of the property, i.e. type of foundation, wall, floor, ceiling, and roof construction. Observe and render an opinion of the readily accessible structural systems and components of the property. Use this directed evaluation report form to address the structural systems and components. Explain why a structural system or component cannot be observed when the following conditions are present, i.e. no access or excessive storage, etc. Describe the defects and their cause(s). If cause is unknown, outline the next action necessary to determine the cause(s). Provide an outline of possible solutions and costs to correct. The outline shall not be considered a design solution. Note: Solutions and costs are necessary to help our client understand the extent of defects and their solutions. Costs are not considered firm, rather an indication of the level of concern.

LIMITING PARAMETERS Structural Evaluations for Clients: • • • • • • • • • • • • • • • • •

Do not include conditions which may become, or cause, structural deficiencies or defects if not addressed. Are limited to the condition of the structure at the time of the evaluation. Are opinions based on visual evidences of readily accessible areas. Do not include destructive or invasive testing. Are not technically exhaustive and do not include comprehensive engineering evaluations. Are not a fulfillment of any state or local disclosure requirements. Do not include systems or components that are not related to the structure, such as Heating, AC, Electrical, Plumbing, Roofing, etc. Do not include recommendations for improvements or upgrades. Do not include maintenance and/or cosmetic suggestions or recommendations. Do not include warranties or guarantees. Αre not a replacement for a buyer’s pre-purchase Home Inspection. Do not determine the presence or absence of any suspected hazardous substances including but not limited to toxins, carcinogens, noise, and or contaminants in soil, water, and air. Are not for compliance or non-compliance of governing building codes. Do not report on the presence or absence of pests such as wood destroying organisms, rodents, or insects. Do not require the engineer to enter any area or perform any procedure that may damage the property or present a danger to the engineer or others. Do not require the engineer to move personal items, furniture, equipment, plant life, soil, snow, ice, or debris that obstructs access or visibility. Are intended for the sole use of U.S. Inspect’s client. Any other use of this report is strictly prohibited.

GENERAL DESCRIPTION Type: [] Ranch/Bungalow [] Cape Cod [] Split level [] Other:__________________________ Roof design: [] Gable additional:

[] Hip

[X] Flat

[X] Two story

[] Shed/Lean to

[] Three story

[]Mansard [] Other or

Foundation construction type: [] Slab on grade [] Crawl space [X] Basement [] Other or combo:_______________________

3 STRUCTURAL DESCRIPTION OF THE PROPERTY Main structure types: [] Masonry [X] Frame [] Other or combo: Foundation walls:

[] Poured concrete [] Other or combo:

[] 8” Block

[] 12” Block

[] Stone [X] Brick

Exterior wall surfaces: [X] Wood siding [] Wood shingles []Aluminum siding [] Vinyl siding [] Stone [] Stone veneer [] Brick [] Brick veneer [] Stucco veneer [] Asphalt shingles/siding [] Plywood [] Cement-Asbestos siding [] Composition siding [] Other: Floor systems: [X] Wood floor joists on wood sill plates [] Wood trusses [] Steel trusses [] Wood floor joists into masonry wall pockets []Poured concrete (living area) [] Reinforced concrete [] Other or combo: Roof systems: [X] Wood rafters and ceiling joists (stick built) [] Wood trusses [] Other: Garage types: [X] Attached [] Detached [] Other: Exterior walls: [X] Frame [] Masonry [] Other: Floor: [X] Poured concrete [] Dirt [] Other: Roof: [] Wood rafters and ceiling joists [] Wood trusses [X] Other: Located under living area OTHER STUCTURE TYPES: [] 2nd Garage [] Barn [] Shed [] Other: Exterior walls: [] Frame [] Masonry [] Other: Floor: [] Wood frame [] Poured concrete [] Dirt [] Other: Roof: [] Wood rafters and ceiling joists [] Wood trusses [] Other: STATUS DEFINITIONS AC = Acceptable: Performing its intended function as of the date of the evaluation. NP = Not present: Does not exist in the structure being inspected. NI = Not inspected: When an item is not evaluated, the reason or explanation is to be included. D = Defective: A structural system or component with one or more of the following evidences: • • • • •

Not performing its designed function. Structurally unsound. Compromised or misused. Not installed or built according to accepted practices or specifications. Adversely effecting the structural integrity.

4 CONDITION OF STRUCTURAL COMPONENT Answer the following questions: • • •

WHAT is the defect? WHY is it a defect or what problem is it causing? WHERE is the defect located? Please be specific.

**IMPORTANT: The explanation of defect for any item(s) marked “D” as well as reasons why, for any item(s) marked “NI” needs to be explained next to its respective line item below. Please mark an item “D” only if it has a structural defect.

AC NI NP D 1 X _ _ _ FOOTINGS: See No. 2, Foundation Walls below. 2 X _ _ _ FOUNDATION WALLS: Interior floors are out-of-level throughout the home. Uneveness is most noticible in the living room which is located over the front of the garage. Some of the sloping floors may be due to long-term deflection of floor joists while the predominate slope to the right in the living room and bedroom behind is due to settlement at the right side of the garage. Significantly out-of-square windows and door at the right side light-well are further evidence of settlement. Along the right side of the garage near the front door the settlement is visible in the top of the foundation wall. Interior wall and ceiling finishes are in very good condition indicating that there has been little-to-no settlment since the interior was last refurbished. Tile at bathroom floors and tub surrounds is likewise in good condition with no visible cracks or grout spalling. It appears that most, if not all, settlement has already occurred. At this point there is little to gain by installation of new piers or piles to support the foundation. Mortar is soft at the brick foundation along the right side of the garage near the front. This appears to be due to long-term contact with moisture seeping through from the exterior soil. Eventually the mortar will deteriorate to the point where it no longer supports the exterior wall load and the foundation will need to be replaced. In it’s current condition the ability of the brick foundation wall to resist lateral loads can not be determined without benefit of a mortar bed test and structural analysis. The foundation does appear to be supporting gravity loads so far. Limited repair to the upper 12” of the brick foundation has been done since 1997 along the back of the garage partition wall between garage units and along the back. 3

X _

_

_ SILL PLATES:

6

GARAGE/CARPORT:_X_ Garage ___ Carport A NI NP D X _ _ _ STRUCTURAL CONDITION:

_X_ Attached

___ Detached

OTHER NON-HABITABLE BUILDINGS: Types: A NI NP D _ _ X _ STRUCTURAL CONDITION: Additional Comments or Notes: I certify that I have adhered to the terms of this assignment according to the guidelines outlined in the report. ______________________ __________________

Engineer’s Name: PE License # : 45625

Willard Decker, P.E. Tax ID #: 77-0470721

Date: April 12, 2010 Signature:

8 PHOTOGRAPHS

Photo No. 1.

Front of 4-unit, 2-story building over a full basement.

Photo No. 2.

Back of right half of building with wood deck at the right side behind greenry.

9

Photo No. 3. Right side of the building viewed from the right, front corner showing past work on window and door to accommodate settlement along the right side.

Photo No. 4.

Past foundation repair work at the center partition foundation wall between garages.

10

Photo No. 5.

Soft foundation brick mortar along the right side.

Photo No. 6. Gap between the to of the brick foundation wall and sill plate caused by settlement of the right side foundation wall.

11

Photo No. 7.

Visible sag in the right side foundation wall under the right side of the living room.

Photo No. 8. Garage slab concrete slab cracked and depressed where foundation settlement drug the edge of the slab down with it.

12

Photo No. 9. Extensive slab break-up and “rutting” along the right side which is an indication of soft soil conditions and thin concrete slab.

Photo No. 10.

Concrete slab near the garage door was cracked by foundation settlement and vehicle tire loads.

13

Photo No. 11. Fungus growth at the underside of the back deck. Deck is secured to the home in the left-right direction by short board ledgers nailed to the exterior siding.

Photo No. 12.

Deck posts at the back end do not have a means of lateral resistance.

14

Photo No. 13.

Spliced deck support posts.

Photo No. 14.

Deck railing posts nailed to the deck surface.

15

Photo No. 15.

Deck baluster constructed using ¼” x 1 ½” wood lattice strips.

Photo No. 16.

Deck support posts have no resistance to uplift.