Installation Instructions TV Sportslight

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of death, injury or property damage from fire, electric shock, cuts, abrasions, falling parts, and other hazards: • Service of the equipment must be performed by qualified service personnel. • Installation and maintenance must be performed by a person familiar with the construction and operation of this product and any hazards involved. All applicable codes and ordinances must be followed. • Read this document before installing, servicing, or maintaining this equipment or installing a lamp. These instructions do not cover all installation, service, and maintenance situations. If your situation is not covered, or if you do not understand these instructions or additional information is required, contact Lithonia Lighting or your local Lithonia LIghting Distributor. • Read and follow all warnings and instructions provided by the lamp manufacturer. WARNING Before installing, servicing, or maintaining this equipment, follow these general precautions. To reduce the risk of electrocution: • Make sure the equipment is properly grounded. • Always de-energize the circuit and/or equipment before connecting to, disconnecting from, or servicing the equipment. To reduce the risk of fire: • Keep material away that can burn from hot lamp. • Make sure lamps are correctly installed. • Use supply conductors with a minimum installation temperature rating as specified on equipment. To reduce the risk of personal injury from cuts, abrasions, or falling parts: • Wear gloves to prevent cuts or abrasions from sharp edges when removing from carton, handling and maintaining this equipment. • Do not use abrasive materials, glass cleaners or other solvents on reflector or lens. These substances may damage equipment and cause parts to eventually break and fall. • Do not install a damaged fixture. CAUTION: Observe lamp manufacturer’s recommendations and restrictions on lamp operation, including but not limited to ballast type, burning position, replacement and cycling. Use only lamps that comply with applicable ANSI standards. NOTICE: If lamp is marked

it contains mercury. Follow disposal laws. See www.lamprecycle.org

Lithonia Lighting, a division of Acuity Brands Lighting, Inc., assumes no responsibility for claims arising out of improper or careless installation or handling of this product.

SAVE THESE INSTRUCTIONS procedure p

Lithonia Lighting Outdoor One Lithonia Way, Conyers, GA 30012 Phone: 800-279-8041 Fax: 770-918-1209 www.lithonia.com

"COM". sure to cap off all unused PartBeNumber: RJ5210019 Rev Cfixture leads individually. Revision Date: 6/15/10his

Installation Instructions Delivery: Upon receipt of fixture and accessories (packed separately), thoroughly inspect for any freight damage. All TV Sportslight damage should be reported to the delivery carrier. Compare the catalog description listed on the packing slip with the fixture label on the inside of the housing to be sure you have received the correct merchandise. 1. Mount ballast/socket housing assembly to bracketry Aiming sight Socket (not provided). There are various pole mounting Tempered Ballast Housing Attachment Glass Lens Housing configurations. Work with your sales representative to Screws (4) ensure the proper accessories are ordered. The fixture may be crossarm mounted or tenon mounted. TVTS Gasket tenon slipfitter required for tenon mount. Installation of Grommetted the fixture and/or tenon mount in any other position than Wire Entry Hole what is indicated within the supplied instructions will void all warranties. Stainless Steel Crossarm 2. Make all necessary wiring connections, observing Latch (3) Mounting Vertical proper voltage and polarity. Ensure that wires are not Bracket Reflector Adjustment Mounting being pinched. For multi-tap ballast, see instructions Bolt (5/8 - 11 x 2 3/4) Knuckle below. Optional Heavy 3. Refer to the table on page 1 to be sure the optical Duty Shroud T-hinge assembly is the proper type for your ballast/socket housing assembly. This fixture consists of two components. Be sure you received: 4. Remove top right screw from socket housing. Keep 1. Housing assembly (includes socket) the removed hardware for reinstallation. Orient 2. Optical assembly, (reflector and glass lens) reflector so the aiming sight is pointed up and the hinge is pointed down. Push reflector against the socket BALLAST/SOCKET OPTICAL ASSEMBLY CATALOG NO. housing so the three remaining screw heads pass HOUSING NEMA TYPE through the large end of the keyhole slots. Rotate the CAT. NO. 2 3 4 5 6 reflector so the screw heads are in the narrow end of GENERAL PURPOSE the keyhole slots. Install top right screw and tighten all TV 400S N* HSG GP23A GP23A GP20A GP20A GP20B four screws. Do not over tighten. Over tightening will TV 1000S N* HSG GP23E GP23E GP23A GP23C GP23D cause stripping and void all warranties. TV 400M N* HSG GP23E GP23A GP20A GP20B GP20B 5. Install lamp as per instructions below. * The number that appears in this TV 1000M N* HSG GP23E GP23A GP20A GP20A GP20B 6. Place the lens frame hinge "T" in the hinge slot on the position in the catalog number of the TV 1500M N* HSG GP23E GP23A GP20A GP20A GP20B ballast/socket housing (see label on HEAVY DUTY housing. Close the lens assembly against the reflector, housing) identifies the fixture's NEMA TV 400S N* HSG HD23A HD23A HD20A HD20A HD20B making sure the gasket is seated properly, i.e. gasket is designation. Locate this number in the TV 1000S N* HSG HD23E HD23E HD23A HD23C HD23D flush with lens assembly. The three stainless steel above table and read down the column to TV 400M N* HSG HD23E HD23A HD20A HD20B HD20B latches should be approximately 120 degrees apart. find the corresponding optical assembly TV 1000M N* HSG HD23E HD23A HD20A HD20A HD20B Snap the latches over the lip of the reflector to secure catalog number. TV 1500M N* HSG HD23E HD23A HD20A HD20A HD20B the lens assembly. Upper Visor: Ships separately. 1. The lens assembly complete with the visor support ring (factory installed). 2. Upper visor ready to attach to visor support ring.

Screws and locknuts (5)

Both of the following are required: TVUV20 - Upper Visor for GP20 reflector TVUV20GL - GP20 Lens assembly with Support Ring for visor

Visor

TVUV23 - Upper Visor for GP23 reflector TVUV23GL - GP23 Lens assembly with Support Ring for visor Prior to attaching lens ring to the reflector, attach visor to the visor support ring on the lens ring with the (5) 8-32 x 1/2 screws and locknuts (provided) matching the holes .

Latch (3)

Hinge

Multi-tap Ballast (TB): The multi-tap ballast will be prewired for 277V at the factory. First determine the correct line voltage. Then select the corresponding fixture voltage lead, remove the crimped cap and connect to the supply voltage lead. The fixture lead marked COM should be connected to the neutral supply lead for 120 or 277. For 208 or 240, connect the other incoming hot leg to the fixture lead marked "COM". Be sure to cap off all unused fixture leads individually. Lamp Installation: Verify that the lamp source and wattage corresponds with the fixture and ballast label. HID -Screw the lamp securely into the socket, back it out one or two turns, and tighten securely again. This procedure properly seats the lamp in the socket. Close door using the standard closing screws. Troubleshooting: If this fixture fails to operate properly, check to make sure: The proper lamp is installed correctly. not faulty. • The fixture is grounded correctly. • The line voltage at the fixture is correct.

• The fixture is wired correctly.

• The lamp is

procedure p

©2001 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 06/10

Lithonia Lighting Outdoor One Lithonia Way, Conyers, GA 30012 Phone: 800-279-8041 Fax: 770-918-1209 www.lithonia.com