SAFETY VALVE-LEAK DETECTOR INSTALLATION Model # AS-414 BEFORE YOU BEGIN YOUR INSTALLATION: Turn off water supply.
Specifications:
IMPORTANT NOTE: Over time, the auto shut off valve could REQUIRED TOOLS: get clogged by dirty water. Test periodically by touching the metal plate to water. If the safety valve does not shut off, removeSmall theStandard unit andScrewdriver clear debris.
DIRECT CONNECTION
FROM WATER SUPPLY
When connecting directly to water source, remove adaptors. Connect supply hose from water source to top of safety valve. Connect hose from faucet to side of safety valve. DO NOT OVER TIGHTEN!
• Operating voltage: 9V DC • Cable length: 60” • Inlet/Outlet direct connect: 1/2” male pipe thread • Environment temperature: 33ºF to 140ºF Channel Locks • Maximum pressure: 87psi
FILTRATION CONNECTION When connecting to a filtration system, attach adaptors. Insert supply tube from water source to top of safety valve. Once inserted, pull back on tube to ensure a secure fit. Connect tube from filtration unit to side of safety valve. Turn water back on and check for leaks.
FROM WATER SUPPLY
TO FAUCET
TO FAUCET
MULTI-STAGE FILTRATION SYSTEM
OPERATING INSTRUCTIONS The diagram on left outlines a typical water treatment system installation with a Waterstone Multi-Stage Filtration Unit and a Waterstone Filtration Faucet. Other filtration systems and filtration faucets will vary. Consult local plumbing codes and building regulations before installation. Improperly installed systems could result in water damage due to leaks or flooding. The installer is responsible for ensuring that the installation is in compliance with all applicable state and local regulations.
(A) WATER SOURCE (B) SAFETY VALVE-LEAK DETECTOR (C) MOISTURE SENSOR (D) WATERSTONE FILTRATION SYSTEM (F) WATERSTONE FILTRATION FAUCET
TO ACTIVATE: Insert 9V battery into unit and close lid. Place unit on bottom of cabinet floor where leaking water will pool. Press and hold reset button for four seconds. Safety valve will open and give a long beep sound. Unit is ready to go.
F
A D
AUTO SHUT OFF: When moisture is detected, safety valve will activate and shut off water. Unit will continually beep and blue light will blink to alert you of a leakage. After leakage problem is fixed, press and hold reset button for four seconds. Safety valve will reset and give a long beep sound. Unit is again ready to go. LOW POWER SHUT OFF: When unit’s battery runs low, the control valve will shut off water supply to filtration system. Unit will beep and blinking red light will indicate a battery replacement is needed.