Installation Instructions LAXA Surface Mounted 1 1a 4 5 2 3

Report 2 Downloads 38 Views
Installation Instructions

LAXA Surface Mounted

LA20/30/40/50/60

Mounting Distances

1

Please note mounting locations as below;

Mounting Distances

Please note mounting locations as below

120mm

200mm luminaire

Mounting Back Plate

2

Disassemble the luminaire– NB # use gloves when handling luminaire

Mounting LED Board Clip the LED board onto the back plate.

1a

Fitting

“X”

300mm

140mm

400mm

200mm

500mm

220mm

600mm

340mm

Mounting Back Plate

3

Mount the screws into locations as detailed above, slot back plate onto key holes and tighten assembly.

4

Mounting LED Board

5

Lift the LED board into position and secure in place using screw.

Wire LED board - please use document *Optelma Wiring Instructions – REV L* Ensure all terminations are complete and secure.

MD 8/16

Installation Instructions

LAXA Surface Mounted

LA20/30/40/50/60

Earth Terminal

6

Locate the earth terminal onto the earth point within the luminaire.

Reassembly Of Luminaire

7

Clip the outer profile with diffuser onto the back plate.

MD 8/16