INSTALLATION INSTRUCTIONS Recessed Luminaire Safety Information: • Installation should only be conducted by a qualified electrician in accordance with NEC and any relevant codes • Disconnect the power at the breaker panel before opening fluorescent fixtures • WARNING- Risk of fire or electric shock. Luminaire wiring and electrical parts may be damaged when drilling for installation of LED retrofit kit. Check for enclosed wiring and components. • WARNING-Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician • WARNING – Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings. • WARNING – To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. • WARNING-Risk of fire or electric shock. Not for direct replacement of fluorescent lamps. Use only with corresponding LED drivers per Table 1 below. • Not for use with Dimmers • Suitable for Damp Locations • Only those open holes indicated in the photographs and/or drawings may be made or altered as a result of kit installation. Do not leave any other open holes in an enclosure of wiring or electrical components. • This retrofit kit is accepted as a component of a luminaire where the suitability of the combination shall be determined by CSA or authorities having jurisdiction. • “This luminaire has been modified and can no longer operate the originally intended lamp” shall be marked on the retrofit luminaire where readily visible by the user during normal maintenance including relamping. • SUITABLE FOR USE IN ENCLOSED SURFACE-MOUNTED/RECESSED LUMINAIRES • SUITABLE FOR “TYPE IC” OR “TYPE NON-IC”, LUMINAIRES • These retrofit kits are certified for use in a UL/CUL Listed Recessed Luminaire with minimum dimensions per Table 1 below and with or without a diffuser or lens
Model #’s Included: • 9T101202 • 15T101203 • 15T101204 • 18T101204 • 20T101205 • 25T101204 • 25T101206 • 30T101208 Kit Contents • (4) LED Tubes • (4) LED Drivers • (8) Wire Nuts • (4-8) Tie Straps • (4) Wire Clips • (4) Wire Clip Screws • (8) Driver Screws • Instruction Manual • Modification Label
TABLE 1 Model #
Length
Max # of Lamps/ Fixture
Minimum Fixture Dimensions (2/4-Tube Fixture)
Corresponding LED Driver
# of Tie Straps Required Per Tube
9T101202
2ft
4
24”x24”x4”
SPS-A200905011
*0
15T101203
3ft
4
24”x36”x4”
SPS-A201805011
1
15T101204
4ft
4
24”x48”x4”
SPS-A201505011
1
18T101204
4ft
4
24”x48”x4”
SPS-A201805011
1
25T101204
4ft
4
24”x48”x4”
SPS-A203605011
1
20T101205
5ft
2
4”x60”x4”
SPS-A201805011
2
25T101206
6ft
2
4”x72”4”
SPS-A203605011
2
30T101208
8ft
2
4”x96”x4”
SPS-A203605011
2
*2ft Tubes are Supported by lampholders only www.independenceled.com
O: 484.588.5401
F: 484.588.0038
Corporate Headquarters: Philadelphia Metro: 204 Old Lancaster Rd. Devon, PA 19333 Tri-State NY, NJ, CT Office: 14 East 60th St. (Between 5th & Madison) NY, NY 10022
103-1550001
PAGE 1
INSTALLATION INSTRUCTIONS Recessed Luminaire Recessed Fluorescent Troffer INSTALLATION:
Fluorescent Tubes PREPARE FIXTURE
1. Verify power is turned off
Wireway Cover Fixture Lens
2. Remove fixture lens as shown in FIGURE 1 3. Remove fluorescent tubes from fixture as shown in FIGURE 2
FIGURE 1
4. Remove wireway cover from center of fixture to expose ballast and wiring as shown in FIGURE 2
Ballast 5. Disconnect ballast from power source 6. Cut wires running to lampholders as shown in FIGURE 3
Lampholders
7. Remove ballast from fixture
FIGURE 2
LAMPHOLDERS BALLAST
+ -
FIGURE 3
www.independenceled.com
O: 484.588.5401
F: 484.588.0038
Corporate Headquarters: Philadelphia Metro: 204 Old Lancaster Rd. Devon, PA 19333 Tri-State NY, NJ, CT Office: 14 East 60th St. (Between 5th & Madison) NY, NY 10022
103-1550000
PAGE 2
INSTALLATION INSTRUCTIONS Recessed Luminaire INSTALL STRUCTURAL SUPPORTS 1.
2.
Tie-Straps installed directly between lampholders
3ft-4ft Fixtures
For 3ft-4ft Fixtures: Drill 3/16” hole in front of gear tray directly between lampholders as shown in FIGURE 4. Ensure hole is free of burrs. For 5ft-8ft Fixtures: Drill two 3/16” holes in front of gear tray spaced evenly between lampholders as shown in FIGURE 5. Ensure hole is free of burrs. Insert Anchor-Mount Tie Straps into hole .
FIGURE 4
5ft-8ft Fixtures Anchor-Mount Tie Straps are used for structural support *NOTE: Lampholders will provide additional support of the LED Tubes and have no electrical function after the installation of this retrofit kit.
FIGURE 5
Tie-Straps evenly spaced between lampholders
INSTALL LED DRIVERS 1.
2. 3.
Remove protective film from back of LED drivers and attach to fixture within wireway cover region per FIGURE 6 Secure LED Drivers with screws provided Connect LED Drivers to incoming power as shown in FIGURE 6 and FIGURE 7 (next page)
LED Drivers
A jumper wire may be needed between drivers
www.independenceled.com
O: 484.588.5401
AC Input Wire.
FIGURE 6
F: 484.588.0038
Corporate Headquarters: Philadelphia Metro: 204 Old Lancaster Rd. Devon, PA 19333 Tri-State NY, NJ, CT Office: 14 East 60th St. (Between 5th & Madison) NY, NY 10022
103-1550000
PAGE 3
INSTALLATION INSTRUCTIONS Recessed Luminaire Install LED Drivers (cont’d) ENSURE THAT AC INPUT WIRE IS RELIABLY SEPARATED (MINIMUM ¼” SEPARATION) FROM THE DC OUTPUT WIRE. THIS CAN BE DONE BY RUNNING ALL OF THE AC INPUT WIRING ON ONE SIDE OF THE LED DRIVERS AND ALL OF THE DC OUTPUT WIRING ON THE OPPOSITE SIDE OF THE LED DRIVERS AND USING PROVIDED WIRE CLIPS TO SECURE WIRES TO FIXTURE. ENSURE THAT ALL CLIPS ARE FASTENED WITHIN THE BALLAST COVER REGION. Wire clips reliably separate AC Input Wire from DC Output Wire
AC Input Wire.
DC Output Wire
AC Input Wire DC Output Wire
FIGURE 7 INSERT LAMPS AND REPLACE WIREWAY COVER
1.
Install LED tubes Into lampholders
2.
Connect LED tube push connector to LED driver push connector as shown in FIGURE 8
3.
Wrap Tie-Straps around tube
4.
Replace wireway cover and safely route all wires around end of wireway cover
5.
Place Modification Label In Fixture as shown in Figure 8
6.
Connect Tubes To Push Connectors
FIGURE 8 Place Modification Label inside fixture
Replace fixture lens and illuminate!
FIGURE 9 www.independenceled.com
O: 484.588.5401
F: 484.588.0038
Corporate Headquarters: Philadelphia Metro: 204 Old Lancaster Rd. Devon, PA 19333 Tri-State NY, NJ, CT Office: 14 East 60th St. (Between 5th & Madison) NY, NY 10022
103-1550000
PAGE 4
INSTALLATION INSTRUCTIONS Surface Mount Luminaire Safety Information: • Installation should only be conducted by a qualified electrician in accordance with NEC and any relevant codes • Disconnect the power at the breaker panel before opening fluorescent fixtures • WARNING- Risk of fire or electric shock. Luminaire wiring and electrical parts may be damaged when drilling for installation of LED retrofit kit. Check for enclosed wiring and components. • WARNING-Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician • WARNING – Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings. • WARNING – To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. • WARNING-Risk of fire or electric shock. Not for direct replacement of fluorescent lamps. Use only with corresponding LED drivers per Table 1 below. • Not for use with Dimmers • Suitable for Damp Locations • Only those open holes indicated in the photographs and/or drawings may be made or altered as a result of kit installation. Do not leave any other open holes in an enclosure of wiring or electrical components. • This retrofit kit is accepted as a component of a luminaire where the suitability of the combination shall be determined by CSA or authorities having jurisdiction. • “This luminaire has been modified and can no longer operate the originally intended lamp” shall be marked on the retrofit luminaire where readily visible by the user during normal maintenance including relamping. • SUITABLE FOR USE IN ENCLOSED SURFACE-MOUNTED/RECESSED LUMINAIRES • SUITABLE FOR “TYPE IC” OR “TYPE NON-IC”, LUMINAIRES • These retrofit kits are certified for use in a UL/CUL Listed Recessed Luminaire with minimum dimensions per Table 1 below and with or without a diffuser or lens
Model #’s Included: • 9T101202 • 15T101204 • 18T101204 • 20T101205 • 25T101204 • 30T101208 Kit Contents • (4) LED Tubes • (4) LED Drivers • (2) Grommets • (4) Wire Nuts • (4) Tie Straps • Instruction Manual • Modification Label
TABLE 1
Model #
Length
Max # of Lamps/ Fixture
Minimum Fixture Dimensions (2/4-Tube Fixture)
Corresponding LED Driver
# of Tie Straps Required Per Tube
9T101202
2ft
4
24”x24”x4”
SPS-A200905011
*0
15T101203
3ft
4
24”x36”x4”
SPS-A201805011
1
15T101204
4ft
4
24”x48”x4”
SPS-A201505011
1
18T101204
4ft
4
24”x48”x4”
SPS-A201805011
1
25T101204
4ft
4
24”x48”x4”
SPS-A203605011
1
20T101205
5ft
2
4”x60”x4”
SPS-A201805011
2
25T101206
6ft
2
4”x72”4”
SPS-A203605011
2
30T101208
8ft
2
4”x96”x4”
SPS-A203605011
2
*2ft Tubes are Supported by lampholders only www.independenceled.com
O: 484.588.5401
F: 484.588.0038
Corporate Headquarters: Philadelphia Metro: 204 Old Lancaster Rd. Devon, PA 19333 Tri-State NY, NJ, CT Office: 14 East 60th St. (Between 5th & Madison) NY, NY 10022
103-1550000
PAGE 5
INSTALLATION INSTRUCTIONS Surface Mount Luminaire INSTALLATION:
Fixture Body
PREPARE FIXTURE 1. 2. 3. 4. 5. 6. 7.
Verify power is turned off Remove fixture lens cover as shown in FIGURE 1 Remove fluorescent tubes from fixture Remove Gear Tray from Fixture and Turn over to back side as shown in FIGURE 2 Disconnect Ballast from power source Cut wires running to lampholders as shown in FIGURE 2 Remove ballast from fixture
Gear Tray Fixture Lens FIGURE 1
BACK OF GEAR TRAY BALLAST
+ -
LAMPHOLDERS
FIGURE 2
INSTALL LED DRIVERS 1. Remove protective film from back side of drivers and attach to back of gear tray as shown in FIGURE 3 2. Use screws provided to secure drivers to back of gear tray 3. Connect LED Drivers to incoming power as shown in FIGURE 3. ENSURE THAT AC INPUT WIRING IS RELIABLY SEPARATED FROM DC OUTPUT WIRE BY A MINIMUM OF ¼”. THIS CAN BE DONE BY POSITIONING ALL OF THE AC INPUT WIRING ON ONE SIDE AND ALL OF THE DC OUTPUT WIRING ON THE OPPOSITE SIDE. 4. Drill 2 1” Holes Through Gear Tray as shown in FIGURE 3 5. Install Grommets in Holes 6. Route LED Output wires through holes 7. Re-Install Gear Tray
www.independenceled.com
O: 484.588.5401
BACK OF GEAR TRAY LED Drivers
-
+
AC Input Wire DC Output Wire
LED Drivers
-
+
FIGURE 3 Drill 1” Hole and Install Grommet
F: 484.588.0038
Corporate Headquarters: Philadelphia Metro: 204 Old Lancaster Rd. Devon, PA 19333 Tri-State NY, NJ, CT Office: 14 East 60th St. (Between 5th & Madison) NY, NY 10022
103-1550000
PAGE 6
INSTALLATION INSTRUCTIONS Surface Mount Luminaire
INSTALL STRUCTURAL SUPPORTS 1.
2. 3. 4. 5. 6. 7.
Front of Gear Tray (3ft-4ft Fixtures)
For 3ft-4ft Fixtures: Drill 3/16” hole in front of gear tray directly between lampholders as shown in FIGURE 4. Ensure hole is free of burrs. For 5ft-8ft Fixtures: Drill two 3/16” holes in front of gear tray spaced evenly between lampholders as shown in FIGURE 5. Ensure hole is free of burrs. Insert Anchor-Mount Tie Straps into hole . Install LED Tubes Wrap Tie strap around tube to secure Connect LED Tube Push Connector to LED Driver Push Connector Place Modification Label inside Fixture Replace fixture lens and illuminate!
FIGURE 4 Place Modification Label inside fixture
Tie-Straps installed directly between lampholders
Connect LED Tubes to Push Connectors
Front of Gear Tray (5ft-8ft Fixtures)
Anchor-Mount Tie Straps are used for structural support FIGURE 5 Place Modification Label inside fixture
Tie-Straps evenly spaced between lampholders
Connect LED Tubes to Push Connectors
*NOTE: Lampholders will provide additional support of the LED Tubes and have no electrical function after the installation of this retrofit kit.
FIGURE 6
www.independenceled.com
O: 484.588.5401
F: 484.588.0038
Corporate Headquarters: Philadelphia Metro: 204 Old Lancaster Rd. Devon, PA 19333 Tri-State NY, NJ, CT Office: 14 East 60th St. (Between 5th & Madison) NY, NY 10022
103-1550000