FFLED18 EMERGENCY INSTALLATION SHEET

Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000, or email: [email protected]

IMPORTANT

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. WARNING: Make certain power is OFF and batteries are disconnected before installing or maintaining fixture. No user serviceable parts inside.

Mounting

CAUTION: Suitable as Wet Locations as Wall Mount. 1. Loosen and remove (4) Screws and separate Back Box from Emergency Housing. Use provided tether.

Gasket

Screws

Housing

2. Drill necessary holes on Back Box. Measurements of drill positions are shown below. 3. Match the hole pattern and place the Gasket on the Back Box. 4. Secure the Back Box on the surface with hardware appropriate for the mounting surface. 5. Wire the fixture to the incoming supply wires according to NEC and local codes. Use UL listed wire connectors. 6. For FFLED18/E, each battery unit has one connector. For FFLED18/EC, each battery unit has two connectors as shown below. For details refer to the appropriate Wiring Diagram section and supplied Instruction Sheet.

Back Box

Housing Gasket

Screws

Emergency Batteries

7. Connect the battery connectors. Do not connect the Batteries before wiring the fixture to the supply.

Bracket Screw

8. Secure Housing to Back Box. Check Housing Gasket seal all around. 9. Apply sealant to all unused conduit entry points. To ensure weatherproof seal, apply weatherproof silicone sealant around the edge where the fixture meets the wall. Seal arm thread using teflon tape or silicone sealant.

Bracket

Two connectors for FFLED18/EC

FFLED18/E Battery Connector

FFLED18 EMERGENCY INSTALLATION SHEET CLEANING & MAINTENANCE

DRILL TEMPLATE

CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized.

7.5” 7.500 [190,5]

3.75” 3.750 [95,25]

1. Clean glass lens & fixture with non-abrasive glass cleaning solution. 2. Do not open fixture to clean the LED. Do not touch the LED.

0.6”

.600 [15,24]

2.94” 2.940 [74,68]

US: Pat. D643,147; CN: ZL201130171304.1; MX: pending; TW: Pat. pending; CA: D RAB Lighting Inc. Patent Pending.

Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.

FFLED18/E WIRING DIAGRAM

(Refer to next page for FFLED18/EC wiring diagram)

BATTERY 1

RED

BATTERY 2

RED

WHITE

WHITE

CUSTOMER SHOULD CONNECT ONLY AFTER FINISHING WIRING TO AC POWER. BATTERY COULD HAVE CHARGE & SHOCK

RAB LABEL - ADD

BLACK

SWITCHED HOT FUSE HOLDER

RAB LABEL - ADD

BLACK

BROWN

BODINE BSL722 LED EMERGENCY DRIVER

WHITE

WHITE

WHITE

LABEL PROVIDED

RED-WHITE STRIPE

WHITE - RED STRIPE

LEAVE OPEN

WHITE DO NOT CONNECT

DURING RED MANUFACTURING

RED-WHITE STRIPE

BLACK

UNSWITCHED HOT

RED

BLACK

BLACK

EMERGENCY HOUSING

BLUE

CHARGING INDICATOR LIGHT / TEST SWITCH

RED

VIOLET GREY

BLACK

GREY

CHARGING INDICATOR/ TEST SWITCH

BLACK

YELLOW

WHITE/BLACK

YELLOW - BLACK STRIPE WHITE

COM

RED BLACK

AC DRIVER WHITE

BLACK RED BLACK

RED

BLUE

RED BLACK

GROUND

FFLED18

FFLED18 (3X6) EMERGENCY 120V OR 277V WIRING DIAGRAM

KS

2.22.12 LED18W EMERGENCY 120V OR 277V WIRING

FFLED18 EMERGENCY INSTALLATION SHEET FFLED18/EC WIRING DIAGRAM

(Refer to previous page for FFLED18/E wiring diagram)

RED

RED

WHITE

BLACK

BLACK BLACK

SWITCHED HOT FUSE HOLDER

BAT 1

RED

BLUE/ORANGE

RED BAT 1

BAT 1

WHITE

RED

RED BAT 2

BAT 2

BLUE

BLACK

YELLOW/RED

RED-WHITE STRIPE

RED BAT 2

BAT 2

YELLOW/RED

RAB LABEL - ADD

WHITE - RED STRIPE

BLACK

UNSWITCHED HOT

BODINE BSL722 LED EMERGENCY DRIVER

WHITE

WHITE

LEAVE OPEN DO NOT CONNECT DURING MANUFACTURING

WHITE RED

BLUE

BATTERY 1

BATTERY 2

WHITE WHITE

BROWN

BLUE

VIOLET

RED

GREY

LABEL PROVIDED CHARGING INDICATOR LIGHT / TEST SWITCH

BLACK

CHARGING INDICATOR/ TEST SWITCH

BLACK

GREY WHITE/BLACK YELLOW - BLACK STRIPE

YELLOW

WHITE

COM

CUSTOMER SHOULD CONNECT ONLY AFTER FINISHING WIRING TO AC POWER. BATTERY COULD HAVE CHARGE & SHOCK

WHITE

YELLOW/RED

WHITE

RED-WHITE STRIPE

WHITE

BLUE/ORANGE

YELLOW/RED

RAB LABEL - ADD

BAT 1

EMERGENCY HOUSING

RED BLACK

AC DRIVER WHITE

BLACK RED BLACK

RED

BLUE

RED BLACK

GROUND

FFLED18

FFLED18 (3X6) EMERGENCY COLD 120V OR 277V WIRING DIAGRAM

FFLED18 EMG-IN-0412

KS

4.18.12 LED18W EMERGY COLD 120V OR 277V WIRING