Fluorescent light fixture Each canopy shall be provided with fluorescent light fixture to provide approximately 500LUX at cooking appliances work surface. IP65
PE
1 2 3 4 PE PE
1
2
PE
L
M16
75
HL-x.x
Hood dimension
L
L=1250,=2000, 2x49W
1620
TO LIGHTING FIXTURE IN THE HOOD
REFERENCE TO DOCUMENT S6-OM-EBI-1107-001 FOR HOOK-UP DETAILS
133
190
640
Item 12 detail
UV Ballast
VAV Module Main UV module
Extraction of contaminants from the exhaust air is provided by the KSA multicyclone TM grease extractors. Efficient grease extraction is achieved by forcing the exhaust air to spiral continuously in the same direction in the multiple chambers of the extractor, thus separating the grease particles from the air flow centrifugally. High extraction efficiency and low pressure loss over the KSA remain practically constant in use.
Item 1 detail 50
0
727
REFERENCE TO DOCUMENT S6-OM-EBI-1107-001 FOR HOOK-UP DETAILS
50
Victor A. Ballester Material AISI316L REFERENCE TO DOCUMENT S6-OM-GFO-0002 CONTAINING HANGING DETAIL REFERENCE TO DOCUMENT S6-OM-EBI-1107-001 FOR HOOK-UP DETAILS Center of Gravity Type of hood KWH