Kenmore Dryer Electric Dryer White 26-61202 Gas Dryer ... - Sears

Report 14 Downloads 468 Views
26-61202, 26-71202 Page 1 of 2

SELECTION

KENMORE

Electric Dryers: White

26-61202

Gas Dryers: White

26-71202

DRYER FEATURES Capacity (Cu. Ft.) Sensor Dry Technology CYCLES AND OPTIONS Specialty Cycles and Options

7.0 • 13 / 5 Timed Dry

Touch Up



Air Dry



Wrinkle Guard® Timed Drying Temperature Selections

• 10-20-30-40-5060-70 Min. 3

CONVENIENCE FEATURES Drum Light



Cycle Signal



End of Cycle Signal



Door Configuration

Drop-Down

GENERAL FEATURES Controls

Shown with washer 26-21202

Drum Finish 1/3

Kenmore Dryer

H.P. Motor

Top Finish Leveling Legs

Electric Dryer

Electric Venting

White 26-61202

Gas Venting Electric Dryer Rating: Volts / Hz / Amps

Gas Dryer

Electric Dryer Circuit Req. (60 Hz)

White 26-71202

Gas Dryer Rating: Volts / Hz / Amps

Mechanical Powder-Coated • Powder-Coated • Rear Rear 240 / 60 / 30 30 120 / 60 / 15 – 20

Gas Burner BTU / Hour

22,000

• 7.0 cu. ft. capacity

LP Gas Conversion Kit

26-49572

• Rotary controls

Gas Pipe Size (O.D. Inches) Shipping Weight (Approx. Lbs.) Electric / Gas

• 13 drying cycles and 5 drying options • Auto moisture sensing technology

3/8

125 / 128

WARRANTY 1-Year Limited Warranty – Mechanical and Electrical Parts

• Wrinkle Guard® • Timed drying

Parts & Labor

If used for other than private family purposes, warranty applies for only 90 days.

• Drop-down door

A

D

C

Dimensions, Inches

A

B

C

D

26-6 / 71202

43.375

29

28

13.75

B

16610

26-61202.PDF Due to Sears policy of continuous improve­ment on its products, Sears reserves the right to change materials and specifications without notice. Before installing, consult installation instructions packed with product for current dimensional and installation data.

Effective 12/06/10

26-61202, 26-71202 Page 2 of 2

DRYER VENTING RECOMMENDATIONS Clamps are recommended for wall and dryer connections. Steel clamps designed to resist stretching, with phillips / hex head screw are included one each on elbows and periscopes.

4" Clearance Behind the Dryer is Preferred for Best Airflow. 2" Clearance is Achieved With Periscopes.

4" CLEARANCE BEHIND DRYER 26-49900 — Over-The-Top™ Kit Universal solution, 8 foot length. Kit includes two 4 ft. pipe sections with attached elbows, two close elbows, clamps and wall plate.

26-98379 — Vent Hood Aluminum body and plastic molded hood with a 4" opening.

VENT HOOD TYPE IMPORTANT NOTE: Do not use non-metal flexible duct. Also, when installing the venting system, do not exceed the specified length for the vent duct. Venting systems which are longer than specified will accumulate lint, increase drying time and energy use and shorten the life of the dryer.

Number of 90° Turns

4" 4"

4" 4"

4"

4"

26-49608 — Flexible Pipe 4" x 6' with snap-lock fittings, 90˚ turn takes 1 foot length and 6 inch clearance

2 1/2"2 1/2"

0

64 ft

64 ft

58 ft

1

54 ft

54 ft

48 ft

2

44 ft

44 ft

38 ft

3

35 ft

35 ft

29 ft

4

27 ft

27 ft

21 ft

0

36 ft

36 ft

28 ft

1

31 ft

31 ft

23 ft

2

27 ft

27 ft

19 ft

3

25 ft

25 ft

17 ft

4

23 ft

23 ft

15 ft

2 1/2" Max. Length of 4" Dia. Rigid Heavy Metal Vent

All Electric Dryers Require Cord Order 26-49387

Wire

Length

3

4 ft.

26-49787

3

6 ft.

26-49388*

4

4 ft.

26-49788*

4

6 ft.

2" CLEARANCE BEHIND DRYER 26-49908 — Periscope 0-18" For outlets that overlap or are very close

Max. Length of 4" Dia. Flexible Metal Vent

POWER CORDS FOR ELECTRIC DRYERS ONLY 26-49387, 26-49787

26-49609 — Close Elbow Turns 90˚ within 4", rotating collars and snap-lock fittings

26-49388, 26-49788

26-49904 — Periscope 18-29" Reaches side of most dryers 26-49905 — Periscope 29-50" Reaches top of most dryers Gas Dryer Connector – Stainless Steel 26-49590

1/2"

- 3/8" Flex, 5 ft.

26-49585*

3/8"

- 3/8" Flex, 5 ft.

*Los Angeles only

*Complies with 1/1/96 NEC code revision for new construction and remodeling

16610

26-61202.PDF Due to Sears policy of continuous improve­ment on its products, Sears reserves the right to change materials and specifications without notice. Before installing, consult installation instructions packed with product for current dimensional and installation data.

Effective 12/06/10