Layout1

Report 3 Downloads 250 Views
P:\C1300 CCCSD\C1311 Outfall Flow Meter\Drawings\+Current\+_C4-1.dwg cu

Complete Project Solutions, Inc.

16-Mar-2012 10:04

CPS

OUTFALL IMPROVEMENTS PROJECT, PHASE 6 TE

CEU

TCE

NOV 2011

CIVIL GENERAL NOTES

NOV 2011 ISSUE FOR BID

5019 Imhoff Place, Martinez, CA 94553-4392

7290

C4-1 27

51

cu

P:\C1300 CCCSD\C1311 Outfall Flow Meter\Drawings\+Current\+_C4-2.dwg

NOTES

Complete Project Solutions, Inc.

16-Mar-2012 10:05

CPS

OUTFALL IMPROVEMENTS PROJECT, PHASE 6 TE

CEU

TCE

NOV 2011

CIVIL DETAILS

NOV 2011 ISSUE FOR BID

5019 Imhoff Place, Martinez, CA 94553-4392

7290

C4-2 28

51

P:\C1300 CCCSD\C1311 Outfall Flow Meter\Drawings\+Current\+_C4-3.dwg

NOTES

PLAN

cu

SECTION

Complete Project Solutions, Inc.

16-Mar-2012 10:05

CPS

OUTFALL IMPROVEMENTS PROJECT, PHASE 6 TE

CEU

TCE

NOV 2011

CIVIL DETAILS

NOV 2011 ISSUE FOR BID

5019 Imhoff Place, Martinez, CA 94553-4392

7290

C4-3 29

51

N2 191 400

cu

Ga te

Asp

halt

P:\C1300 CCCSD\C1311 Outfall Flow Meter\Drawings\+Current\+_C4-4.dwg

Dirt

Pipeway

Dirt

Dirt

NOTES

Complete Project Solutions, Inc.

CPS

16-Mar-2012 11:27

SITE PLAN

TE

CEU

TCE

OUTFALL IMPROVEMENTS PROJECT, PHASE 6

7290

SITE PLAN

C4-4

NOV 2011 NOV 2011

ISSUE FOR BID

5019 Imhoff Place, Martinez, CA 94553-4392

30

51

NOTES

P:\C1300 CCCSD\C1311 Outfall Flow Meter\Drawings\+Current\+_C4-5.dwg

KEYED NOTES

cu

PLAN

Complete Project Solutions, Inc.

16-Mar-2012 11:25

CPS

TE

CEU

TCE

OUTFALL IMPROVEMENTS PROJECT, PHASE 6

7290

GRADING PLAN

C4-5

NOV 2011 NOV 2011

ISSUE FOR BID

5019 Imhoff Place, Martinez, CA 94553-4392

31

51

cu

P:\C1300 CCCSD\C1311 Outfall Flow Meter\Drawings\+Current\+_C4-6.dwg

NOTES

Complete Project Solutions, Inc.

16-Mar-2012 11:22

CPS

OUTFALL IMPROVEMENTS PROJECT, PHASE 6 TE

CEU

TCE

NOV 2011

UTILITY PLAN 60" & 72" FLOW METER

NOV 2011 ISSUE FOR BID

5019 Imhoff Place, Martinez, CA 94553-4392

7290

C4-6 32

51

NOTES

20

10

0

-10

P:\C1300 CCCSD\C1311 Outfall Flow Meter\Drawings\+Current\+_C4-7A.dwg

0+00

1+00

2+00

25

20

15

10

5

0

-5

-10 cu

166+00

167+00 Complete Project Solutions, Inc.

16-Mar-2012 10:06

CPS

OUTFALL IMPROVEMENTS PROJECT, PHASE 6 TE

CEU

TCE

NOV 2011

SECTIONS 60" FLOW METER

NOV 2011 ISSUE FOR BID

5019 Imhoff Place, Martinez, CA 94553-4392

7290

C4-7A 33

51

NOTES

20

10

0

-10

P:\C1300 CCCSD\C1311 Outfall Flow Meter\Drawings\+Current\+_C4-7B.dwg

0+00

1+00

2+00

25

20

15

10

5

0

-5

cu

166+00

167+00 Complete Project Solutions, Inc.

16-Mar-2012 10:06

CPS

OUTFALL IMPROVEMENTS PROJECT, PHASE 6 TE

CEU

TCE

NOV 2011

SECTIONS 72" FLOW METER OPTION

NOV 2011 ISSUE FOR BID

5019 Imhoff Place, Martinez, CA 94553-4392

7290

C4-7B 34

51

I GENERAL REQUIREMENTS:

STRUCTURAL GENERAL NOTES V CONCRETE (Continued):

III SUBMITTALS:

IX STRUCTURAL STEEL (Continued):

X STRUCTURAL TESTS & INSPECTION PROGRAM:

VI REINFORCING STEEL:

P:\C1300 CCCSD\C1311 Outfall Flow Meter\Drawings\+Current\+_S4-1.dwg

IV EARTHWORK:

ABBREVIATIONS

VII COLD JOINT SURFACE PREPARATION:

II ADDITIONAL SAFETY NOTES:

VIII ANCHORS & DOWELS:

V CONCRETE:

cu

IX STRUCTURAL STEEL:

Complete Project Solutions, Inc.

16-Mar-2012 10:07

CPS

OUTFALL IMPROVEMENTS PROJECT, PHASE 6 GK

CEU

TCE

NOV 2011

STRUCTURAL GENERAL NOTES

NOV 2011 ISSUE FOR BID

5019 Imhoff Place, Martinez, CA 94553-4392

7290

S4-1 35

51

cu

P:\C1300 CCCSD\C1311 Outfall Flow Meter\Drawings\+Current\+_S4-2.dwg

NOTES

Complete Project Solutions, Inc.

16-Mar-2012 10:07

CPS

GK

CEU

TCE

OUTFALL IMPROVEMENTS PROJECT, PHASE 6

7290

VAULT PLANS

S4-2

NOV 2011 NOV 2011

ISSUE FOR BID

5019 Imhoff Place, Martinez, CA 94553-4392

36

51

cu

P:\C1300 CCCSD\C1311 Outfall Flow Meter\Drawings\+Current\+_S4-3.dwg

NOTES

Complete Project Solutions, Inc.

16-Mar-2012 10:08

CPS

GK

CEU

TCE

OUTFALL IMPROVEMENTS PROJECT, PHASE 6

7290

VAULT SECTIONS

S4-3

NOV 2011 NOV 2011

ISSUE FOR BID

5019 Imhoff Place, Martinez, CA 94553-4392

37

51

CLASS 'B' SPLICES (f'c = 4,000 PSI) BAR SIZE

OTHERS

TOP

#3

19"

25"

#4

25"

33"

#5

31"

41"

#6

37"

49"

#7

54"

71"

#8

62"

81"

#9

70"

91"

#10

79"

102"

#11

87"

114"

NOTES:

cu

P:\C1300 CCCSD\C1311 Outfall Flow Meter\Drawings\+Current\+_S4-4.dwg

NOTES

Complete Project Solutions, Inc.

16-Mar-2012 10:08

CPS

GK

CEU

TCE

OUTFALL IMPROVEMENTS PROJECT, PHASE 6

7290

DETAILS

S4-4

NOV 2011 NOV 2011

ISSUE FOR BID

5019 Imhoff Place, Martinez, CA 94553-4392

38

51

NOTES

SIDE ELEVATION

cu

P:\C1300 CCCSD\C1311 Outfall Flow Meter\Drawings\+Current\+_S4-5.dwg

FRONT ELEVATION

Complete Project Solutions, Inc.

16-Mar-2012 10:09

CPS

GK

CEU

TCE

OUTFALL IMPROVEMENTS PROJECT, PHASE 6

7290

DETAILS

S4-5

NOV 2011 NOV 2011

ISSUE FOR BID

5019 Imhoff Place, Martinez, CA 94553-4392

39

51

cu

P:\C1300 CCCSD\C1311 Outfall Flow Meter\Drawings\+Current\+_S4-6.dwg

NOTES

Complete Project Solutions, Inc.

16-Mar-2012 10:36

CPS

OUTFALL IMPROVEMENTS PROJECT, PHASE 6 GK

CEU

TCE

NOV 2011 NOV 2011

DETAILS

7290

S4-6

ISSUE FOR BID

5019 Imhoff Place, Martinez, CA 94553-4392

40

51

PIPING SYMBOLS

LINE SYMBOLS

GENERAL MECHANICAL NOTES I. SCOPE OF WORK

ABBREVIATIONS

IV. SUBMITTALS

II. REFERENCE CODES

V. DELIVERY, STORAGE & HANDLING

III. QUALITY ASSURANCE

P:\C1300 CCCSD\C1311 Outfall Flow Meter\Drawings\+Current\+_M4-1.dwg

VALVE DESIGNATIONS

cu

PIPING DESIGNATIONS

Complete Project Solutions, Inc.

16-Mar-2012 10:31

CPS

OUTFALL IMPROVEMENTS PROJECT, PHASE 6 JM

CEU

TCE

NOV 2011

MECHANICAL GENERAL NOTES

NOV 2011 ISSUE FOR BID

5019 Imhoff Place, Martinez, CA 94553-4392

7290

M4-1 41

51

P:\C1300 CCCSD\C1311 Outfall Flow Meter\Drawings\+Current\+_M4-2.dwg

NOTES

C L PIPE

PUMP SCHEDULE MFR

QTY

GPM

HEAD FT H20

TYPE

BHP

MOTOR HP

RPM

REMARKS

cu

TAG

Complete Project Solutions, Inc.

16-Mar-2012 10:32

CPS

OUTFALL IMPROVEMENTS PROJECT, PHASE 6 JM

CEU

TCE

NOV 2011

VAULT PLAN, SECTION, DETAILS & SCHEDULES

NOV 2011 ISSUE FOR BID

5019 Imhoff Place, Martinez, CA 94553-4392

7290

M4-2 42

51

ABBREVIATIONS

cu

P:\C1300 CCCSD\C1311 Outfall Flow Meter\Drawings\+Current\+_E4-1.dwg

GENERAL ELECTRICAL NOTES

Complete Project Solutions, Inc.

16-Mar-2012 10:11

CPS

OUTFALL IMPROVEMENTS PROJECT, PHASE 6 JU

CEU

TCE

NOV 2011

ELECTRICAL GENERAL NOTES

NOV 2011 ISSUE FOR BID

5019 Imhoff Place, Martinez, CA 94553-4392

7290

E4-1 43

51

cu

P:\C1300 CCCSD\C1311 Outfall Flow Meter\Drawings\+Current\+_E4-2.dwg

Dirt

NOTES

Complete Project Solutions, Inc.

16-Mar-2012 10:14

CPS

OUTFALL IMPROVEMENTS PROJECT, PHASE 6 JU

CEU

TCE

NOV 2011

SITE PLAN POWER & LIGHTING

NOV 2011 ISSUE FOR BID

5019 Imhoff Place, Martinez, CA 94553-4392

7290

E4-2 44

51

NOTES

P:\C1300 CCCSD\C1311 Outfall Flow Meter\Drawings\+Current\+_E4-3.dwg

LIGHT FIXTURE SCHEDULE

cu

NOTES

Complete Project Solutions, Inc.

16-Mar-2012 10:15

CPS

OUTFALL IMPROVEMENTS PROJECT, PHASE 6 GK

CEU

TCE

NOV 2011

VAULT PLAN, SECTION, DIAGRAM & SCHEDULES

NOV 2011 ISSUE FOR BID

5019 Imhoff Place, Martinez, CA 94553-4392

7290

E4-3 45

51

P:\C1300 CCCSD\C1311 Outfall Flow Meter\Drawings\+Current\+_E4-4.dwg cu

Complete Project Solutions, Inc.

16-Mar-2012 10:15

CPS

OUTFALL IMPROVEMENTS PROJECT, PHASE 6 JU

CEU

TCE

NOV 2011

ELECTRICAL DETAILS

NOV 2011 ISSUE FOR BID

5019 Imhoff Place, Martinez, CA 94553-4392

7290

E4-4 46

51