LBUH UH Series Brochure 11 13

Report 6 Downloads 58 Views
uh

SERIES

detroit radiant

fa

uh SERIES gas-fired, separated combustion unit heater The UH Series line of gas-fired, tubular exchanger, induced draft hot air heaters are now available for use in commercial, industrial, agricultural and residential applications. This line of heaters features a low profile design with a durable, powder-coated black enamel exterior and stainless steel louvers for an exceptional aesthetic appeal. Additional features include operational troubleshooting lights, finger-proof fan guards, and integrated mounting brackets for ease in installation. The UH Series can be used as separated combustion or power-vented combustion out -of-the-box.

products company Compact Comfort

MODEL Number UH-30 UH-45 UH-60 UH-75

Gas Type Nat. or LP Nat. or LP Nat. or LP Nat. or LP

Typical Approx. AvERaGE VENT BTU/H Mounting Heat air Temp Ship LENGTH INPUT OUTPUT Height Throw Rise Min. Max. weight 30,000

24,000

8 to 12 Ft.

26 Ft.

45°F

3 Ft. 30 Ft.

77 Lbs.

45,000

36,000

8 to 14 Ft.

28 Ft.

45°F

3 Ft. 30 Ft.

77 Lbs.

60,000

48,000

10 to 16 Ft.

37 Ft.

45°F

3 Ft. 30 Ft.

98 Lbs.

75,000

60,000

10 to 18 Ft.

39 Ft.

45°F

3 Ft. 30 Ft.

98 Lbs.

TYPICAL APPLICATIONS

PRODUCT FEATURES Operational Indicator Lights

Fan Guard

• Greenhouses

Mounting Brackets

• Garages Stainless Steel Discharge Louvers Aluminized Steel Tubular Heat Exchangers

• Check-in/out Areas • Vestibules • Entrance Ways • Work Stations • Spot or Total Building Heat

Service Access Handle Burner Sight Glass

Powder Coated Black Enamel Exterior

• Compact, aesthetically pleasing construction. • Easy to install with minimal assembly required. • Mounting brackets are standard. • Indicator lights are standard. • Finger proof fan guards are standard. • All UH models can be rotated 180˚. • North American ETL certified for both indoor and residential use.

detroit radiant products co. 21400 Hoover Rd. Warren, MI 48089-3162 Phone: Toll Free: Fax: Email: Website:

(586) 756-0950 1-800-222-1100 (586) 756-2626 [email protected] www.detroitradiant.com

Visit Our Website For: Product Specs Parts Support Dealer Locator Applications

C.A.D. Library Design Guidelines Theory of Infrared and More!

uh SERIES

SPECIFICATIONS PRODUCT SPECIFICATIONS

MOUNTING:

VOLTAGE:

• 120/60Hz.VAC (primary). • 24 VAC (thermostatic). • Single phase.

Input Range:

30,000 to 75,000 BTU/h

Gas Type:

Natural or Propane

Burner Control Box:

Powder Coated Black Enamel

• Natural Gas - 3.5 Inches W.C. • Propane Gas - 10.0 Inches W.C.

Radiant Exchanger Tubes:

Tubular Aluminized Steel

INLET PRESSURE:

Certification:

ETL Listed North America

Limited Warranty:

MANIFOLD PRESSURE:

1-3-5 (Components-Exchangers-

• Natural Gas - 5.0 to 14.0” W.C. • Propane Gas - 11.0 to 14.0” W.C.

Burners)

GAS CONNECTION

24V Controls:

Thermostat Connection

Operational Indicator Lights:

Standard

• Four (4) suspension points. • Slotted mounting brackets accommodate joists on 16 or 24 inch centers. • 180˚ mounting

CERTIFICATIONS:

• ANSI Z83.8/CSA 2.6 • Commercial & Industrial use. • Residential use. • Indoor use only.

OTHER

•External indicator lights. • External thermostatic • 1/2” N.P.T. connection. • Field connect to valve. • Approved for elevations 0 - 2,000 ft. without VENT & INLET CONNECTION: modifications. • Category l or lll venting. • Supplied standard as • Rear, horizontal discharge/inlet. separated combustion. • 3” to 4” inlet adapter included for UH-30 and UH-45 models

Available uh SERIES models & dimensions Model

FLA AMPS

Motor Type

MoTor HP

Fan DiaMeter

Axial Fan Rotation

Gas Connection

Inlet & Vent Connection

heater width dim “a”

heater depth dim “b”

heater height dim “c”

air to vent dim “d”

UH-30

2.7

SP

1/15

10 in.

CCW

1/2” NPT

3” O.D.

28 in.

17 in.

12 in.

4.4 in

UH-45

2.7

SP

1/15

10 in.

CCW

1/2” NPT

3” O.D.

28 in.

17 in.

12 in.

4.4 in

UH-60

4.0

PSC

1/12

14 in.

CCW

1/2” NPT

4” O.D.

28 in.

17 in.

17 in.

7.4 in

UH-75

4.0

PSC

1/12

14 in.

CCW

1/2” NPT

4” O.D.

28 in.

17 in.

17 in.

7.4 in.

Top View

Rear View

7.12”

DIM. A

3.78” DIM. D

DIM. B

DIM. C

6.54”

3.96”

5.3”

2.86” DIM. A

uh SERIES clearances All Models

Front

Top and Bottom

Access Side

Non-Access Side

Rear

Vent Connection

Clearance to Combustibles

60 in.

1 in.

18 in.

1 in.

1 in.

6 in.

Clearance to Allow Service

60 in.

1 in.

18 in.

1 in.

18 in.

6 in.

FRONT VIEW

Vent Connection

Top

SIDE VIEW

Top

NonAccess Side

Access Side

Front Rear

Bottom

DISTRIBUTED BY:

Bottom

LBUH-UH 11/13 DRP