©2011 Koninklijke Philips Electronics N.V. All rights reserved. Specifications are subject to change without notice. Brochure number: 11-0064
Philips Lightolier 631 Airport Road Fall River, MA 02720 Phone (508) 679-8131 Fax (508) 674-4710 www.lightolier.com
3015 Rue Louis Amos Lachine (Quebec) H8T 1C4 Phone (514) 636-0670 www.canlyte.com
LED Luminaires Linear recessed and surface fixtures
Philips Lightolier | LED Luminaires
More than innovation Design flexibility
Delivering 80+ CRI
Our intelligent driver technology,
Our color evaluation data goes
called the LitePlane platform, is a
beyond CRI by delivering the spectral
factory calibrated system providing
power distributions of each fixture.
the customer a choice of multiple
While CRI remains the standard
lumen packages allowing for
international metric for color
full control of operation power
performance, evaluating the spectral
consumption and light output.
power distribution (SPD) gives a
with an optimized optical system for superior results.
100
Spectral Flux (mW/nm)
Low brightness LEDs are combined
Thermal management is integrated into the fixture.
Easy maintenance
Skyway LED
Modern triple lens design features a clear conical prismatic center lens complemented by frosted white acrylic side lenses.
SpecPlus LED
Crisp, clean lines and minimalist design are sure to bring style, freshness and subtle distinction to modern office and retail interiors. Armstrong TechZone™ compatible.
60 40 20 400
450
500
550
600
650
700
750
800
850
Wavelength (nm)
Longer life without heat sinks
Deep curved lens, combined with a regressed frame opening, appears as a cove or skylight.
Lytecel 6 Lens LED
Opalescent 2'X2' LED
80
0 350
Opalescent LED
Enter the era of the green office easily with the SpecPlus LED and 89.8 delivered lumens per watt.
more complete picture.
Uniformity and visual comfort
Philips Lightolier introduces LED to
Stairwell LED
Function, safety and efficiency with bi-level output and occupancy sensing.
Sealatron LED
With Sealatron LED, lamp changes are a thing of the past — just install and forget about this long-life luminaire.
Drivers and LEDs are field replaceable.
2
Philips Lightolier
3
Philips Lightolier | LED Luminaires
Opalescent LED 2' x 2'
Fixture construction includes field replaceable LEDs and drivers. 84.0 lumens per watt efficacy. 80+ CRI.
Low brightness LEDs for uniformity and visual comfort
Opalescent
Body Style
OP
Fixture Size
Ceiling Type
22
Direct Recessed Luminaire
A = Air S = Static
Lumen Category
Color Temp.
Voltage
Driver Type
40
U
LAG
25A = 2500 lm 33A = 3300 lm 38A = 3800 lm 42A = 4200 lm (Approximate delivered values. Consult IES file)
40 = 4000K Consult representative for other color temperature options. (Approximate values. Consult IES file)
22 = 2' X 2' (Nominal size)
U = Universal 120-277v
Lens
PW G = 9/16" or 15/16"Grid T = Slot Grid
LAG = LED Driver Consult representative for dimming options
PW = High light transmission frost white acrylic lens
Options Add appropriate suffix to catalog no., i.e.: (C)
Skyway LED 2' x 2'
Fixture construction includes field replaceable LEDs and drivers. 78.3 lumens per watt efficacy. 80+ CRI. Superior efficacy and longer life Intelligent driver technology Dimming options Delivering 80+ CRI
Skyway
SK
Ceiling Type
Lens
22 A = Air S = Static
Lumen Category
Color Temp.
Voltage
Driver Type
40
U
LAG
(Approximate delivered values. Consult IES file)
Philips Lightolier
Fixture Size
Direct Recessed Luminaire
25A = 2500 lm 33A = 3300 lm 38A = 3800 lm
4
Body Style
40 = 4000K Consult representative for other color temperature options. (Approximate values. Consult IES file)
22 = 2' X 2' (Nominal size)
U = Universal 120-277v
G = 9/16" or 15/16"Grid T = Slot Grid
LAG = LED Driver Consult representative for dimming options
PK = Pattern 19, 0.156 virgin acrylic center lens with frost white acrylic side lenses. PP = Frost white acrylic center lens with frost white acrylic side lenses.
Options Add appropriate suffix to catalog no., i.e.: (C)
5
Philips Lightolier | LED Luminaires
Superior efficacy and longer life Superior efficacy and longer life
Intelligent driver with customizable performance
Dimming options
30 to 53 input watts
Delivering 80+ CRI
89.8 lumens per watt efficacy
Shallow 5" Deep housing
Air handling / Static housing for Skyway and Opalescent (shown)
Static housing for SpecPlus.
SpecPlus LED 2' x 2' SpecPlus
Body Style
Fixture Size
Ceiling Type
SP
S
22
G
Direct Recessed Luminaire
S = Static
22 = 2' X 2' (Nominal size)
G = 9/16" or 15/16"Grid
Lens Frame FS = Flat steel frame FA = Flat aluminum frame RA = Regressed aluminum frame
Lens Shielding KA = 0.156 Prismatic acrylic lens VA = 0.095 Prismatic acrylic lens
Lumen Category 25A = 2500 lm 33A = 3300 lm 38A = 3800 lm 42A = 4200 lm (Approximate delivered values. Consult IES file)
Color Temp.
Voltage
Driver Type
40
U
LAG
40 = 4000K Consult representative for other color temperature options. (Approximate values. Consult IES file)
U = Universal 120-277v
LAG = LED Driver Consult representative for dimming options
Options Add appropriate suffix to catalog no., i.e.: (C)
Fixture construction includes field replaceable LEDs and drivers accessible from below.
Positive latch for lens frame
6
Philips Lightolier
Hold-down mounting frame clip
Access plate located on end-cap
7
Philips Lightolier | LED Luminaires
Customizable lumen package. Optimized optical system.
Discreet ventilation system allows for air-return without changing the look of the fixture. LED array is field replaceable from below the ceiling.
Superior efficacy and longer life
Intelligent driver customizable performance
Intelligent driver technology
30 to 53 input watts
Dimming options
66.2 lumens per watt efficacy
Designed to fit grid ceilings as well as Armstrong TechZone™. Two hold down clips. Meets NYC code requirements.
Delivering 80+ CRI 6" fixture depth
Lytecel 6 Lens LED 6" x 48" Lytecel 6
Body Style
LI Direct Linear Recessed
8
Fixture Size
Ceiling Type
64 A = Air Return S = Static
Philips Lightolier
64 = 6" X 48" (Nominal size)
Lens
Lumen Category
PN G = 9/16" or 15/16"Grid T = Slot Grid D = 9/16" Tegular Grid
PN = .08 White Acrylic
20A = 2000 lm 25A = 2500 lm 28A = 2800 lm 31A = 3100 lm (Approximate delivered values. Consult IES file)
Color Temp.
Voltage
Driver Type
40
U
LAG
U = Universal 120-277v
LAG = LED Driver
40 = 4000K Consult representative for other color temperature options. (Approximate values. Consult IES file)
Consult representative for dimming options
Concealed air-returns vent into ceiling plenum. Options Add appropriate suffix to catalog no., i.e.: (C)
9
Philips Lightolier | LED Luminaires
Maximize energy savings with auto-activated bi-level
Versatile intelligent driver
Concealed spring-
Field adjustable
Integrated ultrasonic
Optional stainless
assisted pressure latch retains lens.
sensor controls.
or infrared motion sensor.
steel latches available.
Stairwell LED
Sealatron LED Wall, ceiling or suspended mounted. Low temperature operation.
Wall or ceiling mountable, slim profile (3 7/8"), bi-level luminaire. Integrated motion
Intelligent drive technology, IP65 standard / IP67 available for
sensor and bi-level step driver provide standby, low-level light and, upon detecting
wet location applications.
motion, restore lighting to full brightness. Sensor also allows for on / off operation.
Stairwell
Fixture Length
Lens Type
SF
4
C
Direct-Indirect Recessed Luminaire
4 = 48" (Nominal size)
C = White Composite Acrylic Lens
Lumen Category 23A = 2300 lm 28A = 2800 lm 33A = 3300 lm 38A = 3800 lm (Approximate delivered values. Consult IES file)
10
Philips Lightolier
Color Temp.
Voltage
40
U
40 = 4000K Consult representative for other color temperature options. (Approximate values. Consult IES file)
U = Universal 120-277v
Driver Type LAG = LED Driver MKB = LED Bi-level step Driver. (38A Only)
Sensor Type US = Ultra Sonic OS = Infrared
Options Consult factory.
Sealatron
Fixture Size
Damp/Wet Location
Lens Shielding
ST
74
W
A
Enclosed Industrial
74 = 7" X 4'
W = Wet location
A = DR Acrylic lens
(Nominal size)
Lumen Category 23A = 2300 lm 35A = 3500 lm 43A = 4300 lm 51A = 5100 lm (Approximate delivered values. Consult IES file)
Color Temp.
Voltage
40
U
40 = 4000K (Approximate values. Consult IES file)
U = Universal 120-277v
Driver Type
Options
MKB = 23A LED Driver MKA = 35A LED Driver ADB = 43A LED Driver PHA = 51A LED Driver
Add appropriate suffix to catalog no., i.e.: (C)
11
Philips Lightolier | LED Luminaires
Spectral power distribution gives the complete color picture.
LED specific test data Independent test data
LM-79 Electrical and Photometric Measurements of Solid-State Lighting Products
Delivering 80+ CRI Our color evaluation data goes beyond CRI by delivering the spectral power distributions of each LED. While CRI
An IES-approved method to quantify the performance of the fixture’s total luminous flux, luminous efficacy (l/w), luminous intensity (candelas) and chromaticity, CRI and color temperature.
is the only agreed upon international metric for color evaluation, it presents some challenges. Evaluating the spectral power distribution SPD gives a more complete picture.
Skyway LED 100
Spectral Flux (mW/nm)
Opalescent 2'X2' LED
80 60 40 20 0 350
400
450
500
550
600
650
700
750
800
850
Skyway 2'X2' LED
125
80 60 40 20 0 350
400
450
500
550
600
650
Wavelength (nm)
Lytecel 6 Lens 6"X48" LED
100 75 50 25 0 350
400
450
500
550
600
650
700
750
800
850
Wavelength (nm)
12
Philips Lightolier
750
800
850
75 50
35
0 350
28 21 14 7 400
450
500
550
600
400
450
500
550
600
650
700
750
800
850
Wavelength (nm)
Sealatron LED
Stairwell LED
0 350
LM-80 Measuring Lumen Maintenance of LED Light Sources
25
Stairwell LED Spectral Flux (mW/nm)
Spectral Flux (mW/nm)
125
700
Wavelength (nm)
Lytecel 6 Lens LED
SpecPlus 2'X2' LED
100
650
700
750
800
850
Wavelength (nm)
Spectral Flux (mW/nm)
Spectral Flux (mW/nm)
100
SpecPlus LED Spectral Flux (mW/nm)
Opalescent LED
This method specifies that products should be tested with absolute rather than relative photometry. Absolute photometry takes into account the performance of the LEDs as used in a particular fixture in its production configuration. The impact of the fixture’s orientation and thermal management is accounted for in this method.
75
The LED manufacturers provide life ratings for individual LEDs at specific drive currents and operating temperatures.
Sealatron LED
60 45
In turn, the luminaire manufacturer measures the drive current and temperature in the LED fixture. The data is crossed to estimate LED life in a fixture.
30 15 0 350
An IES-approved method to determine the lumen maintenance of LED light sources.
400
450
500
550
600
650
700
750
800
850
Wavelength (nm)
L70 is the life at which the fixture delivers 70% of initial light output.
13
Philips Lightolier | LED Luminaires
Photometric performance Opalescent LED 2' x 2'
Skyway LED 2' x 2'
SpecPlus LED 2' x 2'
Photometry
Photometry
Photometry
Report Number1: Catalog Number: Delivered Lumens: Input Watts: Efficacy: CCT2: CRI:
G2011090 OPS22GPW38A40ULAG 3619 44.9 80.6 lm/w 4010K 84.4 typical / 80 minimum
Report Number1: Catalog Number: Delivered Lumens: Input Watts: Efficacy: CCT2: CRI:
G2011088 SKS22GPK33A40ULAG 3366 44.9 75.0 lm/w 4014K 84.4 typical / 80 minimum
Report Number1: Catalog Number: Delivered Lumens: Input Watts: Efficacy: CCT2: CRI:
Catalog Number G2011108 SPS22GFSKA38A40ULAG 3841 44.9 80.6 lm/w 4014K 84.4 typical / 80 minimum
Candela Distribution
Candela Distribution
Candela Distribution
Vertical Angle
Vertical Angle
Vertical Angle
0 5 15 25 35 45 55 65 75 85 90
Horizontal Angle
Zonal Lumens 90
0 45 1532 1532 1532 1519 1522 1526 1433 1446 1457 1276 1302 1327 1060 1103 1140 808 866 906 558 611 637 338 370 371 160 170 164 29 29 25 0 0 0
145 408 600 689 664 541 360 177 36
0 5 15 25 35 45 55 65 75 85 90
0 1697 1681 1588 1415 1167 765 406 224 122 27 0
Horizontal Angle
Zonal Lumens 90
45 1697 1697 1677 1682 1590 1593 1401 1397 1094 1070 726 753 475 464 269 257 119 127 25 26 0 0
159 448 646 691 576 415 264 136 30
0 5 15 25 35 45 55 65 75 85 90
Opalescent LED 2' x 2'
Zonal Lumens 90
Stairwell LED
Sealatron LED
Photometry
Photometry
Photometry
Report Number1: Catalog Number: Delivered Lumens: Input Watts: Efficacy: CCT2: CRI:
G2011131 LIA64GPN28A40ULAG 2864 44.9 63.8 lm/w 3930K 84.8 typical / 80 minimum
Report Number1: Catalog Number: Delivered Lumens: Input Watts: Efficacy: CCT2: CRI:
G2011228 SF4C33A40ULAG 3348 45.0 74.4 lm/w 4047K 85.4 typical / 80 minimum
Report Number1: Catalog Number: Delivered Lumens: Input Watts: Efficacy: CCT2: CRI:
189 532 782 870 616 325 161 107 40
Candela Distribution
Candela Distribution
Vertical Angle
Vertical Angle
Vertical Angle
0 5 15 25 35 45 55 65 75 85 90
1 2
Horizontal Angle
Zonal Lumens 90
0 45 1223 1223 1223 1204 1214 1222 1153 1142 1133 1060 1012 972 931 837 813 777 671 629 599 482 416 403 277 210 201 96 97 37 32 30 4 9 10
115 323 468 537 529 437 286 133 36
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180
0 478 499 535 556 560 547 517 474 424 378 363 387 436 485 525 551 559 550 526 486 466
Horizontal Angle 90 478 483 457 408 343 272 201 135 78 33 20 37 82 138 202 272 341 403 449 474 466
Zonal Lumens 180
478 466 432 368 301 232 164 102 52 12 2 10 49 100 162 231 301 366 420 454 466
46 133 201 245 260 249 219 178 137 141 183 223 252 262 244 199 130 45
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180
Horizontal Angle
0 45 90 1515 1515 1515 1499 1496 1491 1451 1444 1450 1359 1339 1316 1211 1165 1177 1006 968 993 742 743 792 460 542 579 220 327 314 49 94 84 10 43 38 18 29 24 13 28 20 4 23 18 0 13 16 0 4 11 0 0 4 0 0 0 0 0 0 0 0 0 0 0 0
Average initial 8'X8' footcandles
8'X8' Watts per sq. foot
Average initial 8'X10' footcandles
8'X10' Watts per sq. foot
2553 3167 3619 4140
30.4 38.4 44.9 52.8
84.0 82.5 80.6 78.4
42 52 59 68
0.48 0.60 0.70 0.83
34 42 48 55
0.38 0.48 0.56 0.66
Catalog Number
Delivered Lumens
Input Watts
Lumens per Watt
Average initial 8'X8' footcandles
8'X8' Watts per sq. foot
Average initial 8'X10' footcandles
8'X10' Watts per sq. foot
2381 3366 3851
30.4 44.9 52.8
78.3 75.0 52.8
40 56 64
0.48 0.70 0.83
32 35 52
0.38 0.56 0.66
Delivered Lumens
Input Watts
Lumens per Watt
Average initial 8'X8' footcandles
8'X8' Watts per sq. foot
Average initial 8'X10' footcandles
8'X10' Watts per sq. foot
2722 3362 3841 4397
30.4 38.4 44.9 52.8
89.5 87.6 85.5 83.3
45 55 63 73
0.48 0.60 0.70 0.83
36 46 52 59
0.38 0.48 0.56 0.66
Delivered Lumens
Input Watts
Lumens per Watt
2011 2500 2864 3174
30.1 38.4 44.9 50.8
67.0 65.1 63.8 62.5
SKS22GPK25A40ULAG SKS22GPK33A40ULAG SKS22GPK38A40ULAG
SpecPlus LED 2' x 2' Flat Steel/Aluminum Door Frame with VA Lens
SPS22GFSVA25A40ULAG SPS22GFSVA33A40ULAG SPS22GFSVA38A40ULAG SPS22GFSVA42A40ULAG
LTL23327 ST74WA43A40UADB 4346 48.9 88.9 lm/w 4046K 84.7 typical / 80 minimum
Candela Distribution
Lumens per Watt
OPS22GPW25A40ULAG OPS22GPW33A40ULAG OPS22GPW38A40ULAG OPS22GPW42A40ULAG
Catalog Number
Lytecel 6 Lens LED 6" x 48"
Input Watts
Skyway LED 2' x 2'
Horizontal Angle
0 45 2017 2017 2017 1988 1994 2000 1865 1883 1904 1659 1692 1737 1364 1392 1456 810 766 746 290 400 254 98 153 86 91 61 85 33 35 35 0 0 0
Delivered Lumens
Zonal Lumens 142 410 619 745 762 676 521 306 87 27 22 15 8 4 1 0 0 0 0
Lytecel 6 Lens LED 6" x 48" Catalog Number LIA64GPN20A40ULAG LIA64GPN25A40ULAG LIA64GPN28A40ULAG LIA64GPN31A40ULAG
Stairwell LED Catalog Number SF4C23A40ULAG SF4C28A40ULAG SF4C33A40ULAG SF4C38A40ULAG
Average initial 8'X8'6" Watts per Average initial 8'X8'6" footcandles sq. foot 8'X10'6" footcandles 30 37 42 47
0.44 0.56 0.66 0.75
8'X10'6" Watts per sq. foot
24 30 34 38
0.36 0.46 0.53 0.60
Sealatron LED Delivered Lumens
Input Watts
Lumens per Watt
2323 2840 3348 3828
30.3 38.4 45.0 52.5
76.9 73.5 74.4 72.9
Catalog Number ST74WA23A40UMKB ST74WA35A40UMKA ST74WA43A40UADB ST74WA51A40UPHA
Delivered Lumens
Input Watts
Lumens per Watt
2319 3568 4346 5121
26.3 36.1 48.9 58.6
88.3 95.8 88.9 87.4
Tested using absolute photometry as specified in LM79: IESNA Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products. Correlated Color Temperature within specs as defined in ANSI_NEMA_ANSLG C78.377-2008: Specifications for the Chromaticity of Solid State Lighting Products.
14
Philips Lightolier
15
©2011 Koninklijke Philips Electronics N.V. All rights reserved. Specifications are subject to change without notice. Brochure number: 11-0064
Philips Lightolier 631 Airport Road Fall River, MA 02720 Phone (508) 679-8131 Fax (508) 674-4710 www.lightolier.com
3015 Rue Louis Amos Lachine (Quebec) H8T 1C4 Phone (514) 636-0670 www.canlyte.com
LED Luminaires Linear recessed and surface fixtures