LETTER OF TRANSMITTAL

Report 5 Downloads 85 Views
LETTER OF TRANSMITTAL

MOORE ENGINEERING COMPANY 3637 COLUMBIA AVENUE LANCASTER, PENNSYLVANIA 17603

Phone - (717) 285-3141 FAX - (717) 285-2443

Benchmark Construction 4121 Oregon Pike, PO Box 806 Brownstown, PA 17508

TO:

WE ARE SENDING YOU

Attached

Shop Drawings Copy of Letter

COPIES

DATE

1

DATE: JOB #: ATTN: RE:

Under Separate Cover via the following items

Plans Change Order

NO.

April 12, 2016 15139 John Clemons – Project Manager Luther Acres Muhlenberg

Samples Other

Specifications

DESCRIPTION

4/12/16

Plumbing Fixtures – Approved as Noted

THESE ARE TRANSMITTED as checked below: For Approval For your use As requested For review & comment for bids due

Approved as Submitted Approved as noted Reviewed , 20

Revise & Resubmit Submit ___ copies for distribution Return ___ corrected prints prints returned after loan to us

REMARKS:

Please call with questions or comments

Copy to:

File

Signed: Michael K. Hunt

Submittal Sheet Submittal # 220000 - 1

Date:

4/4/16

Project Name: Luther Acres – Muhlenberg Phase 2, 3, 4

Contractor: Leo Kob Co., Inc. 303 Jonlyn Drive Elizabethtown, PA 17022 (P) 717-367-1363 (F) 717-367-3376

Engineer: Moore Engineering Company 3637 Columbia Avenue Lancaster, PA 17603

Subcontractor/Supplier: APR Supply Co. 749 W Guilford St. Lebanon, PA 17046 Spec Section: PLUMBING FIXTURES 22 00 00 / Dwg P3.1 Remarks: Is this item in variance of the Contract Document?

YES

NO

Approvals Leo Kob Co., Inc. _X

MOORE ENGINEERING COMPANY CONSULTING ENGINEERS LANCASTER, PENNSYLVANIA

APPROVED APPROVED AS NOTED REVISE AND RESUBMIT NOT APPROVED

REVIEWED BY:

KSB

DATE:

4/4/16

COMMENTS:

SHOP DRAWING AND SAMPLE REVIEW REVIEW IS ONLY FOR CONFORMANCE WITH THE DESIGN CONCEPT OF THE PROJECT AND COMPLIANCE WITH THE INFORMATION GIVEN IN THE CONTRACT DOCUMENTS. CONTRACTOR IS RESPONSIBLE FOR ALL QUANTITIES AND DIMENSIONS TO BE CONFIRMED AND CORRELATED AT THE JOB SITE; FOR INFORMATION THAT PERTAINS SOLELY TO THE INSTALLATION PROCESSES AND TO THE TECHNIQUES OF CONSTRUCTION; AND FOR COORDINATION OF THE WORK OF ALL TRADES. CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH CONTRACT DOCUMENTS. ANY EQUIPMENT SUBTITUTIONS AS WELL AS ANY ADDITIONAL LABOR OR MATERIALS REQUIRED AS A RESULT OF A SUBSTITUTION.

APPROVED APPROVED AS NOTED BY

MKH

NOT APPROVED REVISE AND RESUBMIT DATE

4-12-16

Contractor shall coordinate all power, voltage, and dimensional requirements with all other trades.

ES-LFUSG-B-M2

For Residential and Commercial Applications Job Name_______________________________________ Contractor_______________________________________ Job Location_____________________________________ Approval_________________________________________ Engineer_________________________________________ Contractor’s P.O. No._____________________________ Approval_________________________________________ Representative___________________________________

LEAD FREE* Series LFUSG-B Under Sink Guardian®

The LFUSG-B-M2 Under Sink Guardian® 3⁄8" (10mm) compression and Quick-Connect fitting ther­mo­stat­ic mix­ing valves maintain and limit hot water to desired se­lect­able temperature between 80°F and 120°F (27°C and 49°C) with flow rates as low as 0.25 gpm (1.0 lpm) and as high as 2.25 gpm (8.5 lpm). The mix­ing valve is listed to ASSE Standard 1070 for sin­gle fix­ture applications and IAPMO cUPC. The LFUSG-B-M2 features Lead Free* construction to comply with Lead Free* installation requirements. The su­pe­ri­or flow char­ac­ter­is­tics of these valves provide tem­per­at­ure con­trol with low pres­sure drop. As an add­ed fea­ ture, the LFUSG-B -M2 in­cor­po­rates dual check valves to pro­tect against cross-flow and integral screens to filter out debris.

Features

• Lead Free* Brass body construction • Installs easily between the stop valves and faucet • Includes tamper resistant locking nut to prevent accidental misadjustment • Built-in check valves prevent migration of hot water to cold and cold water to hot water piping • Provided with cap for three port application • Integral strainer with 40 mesh stainless steel screens to filter out debris

Applications

The unit is intended for under sink installation to con­trol the hot water temperature and minimize the occurrence of ac­ci­den­tal scald­ing. The water temperature must be adjusted by the in­stall­ er using a thermometer to measure the hot water tem­per­at­ure at the faucet outlet. Maximum tem­per­a­ture of 105°F (41°C) is recommended.

Specifications

A Thermostatic Mixing Valve shall be installed on the hot water supply to the fix­ture. The valve shall be ASSE Standard 1070 and IAPMO cUPC listed and control the temperature of the hot water. It shall have a Lead Free* brass 4-port, “H” pattern body. Lead Free* under counter thermostatic valves shall comply with state codes and standards, where applicable, requiring reduced lead content. The valve shall include integral check valves, integral screens and an ad­just­ment nut with locking fea­ture. The valve shall be pro­vid­ed with 3⁄8" (10mm) male com­pres­sion or Quickconnect fittings. The valve shall be Watts Series LFUSG-B. For satin chrome finish specify – SC.

LFUSG-B-M2

LFUSG-B-QC-M2

ASSE 1070 & IAPMO cUPC Listed

Materials

Body: Lead Free* Brass Rubber Disc: Buna-N

O-rings: Buna-N

Spring: Stainless steel

Piston: Noryl®

Thermostat: Copper

Approval ASSE 1070

Pressure – Temperature Minimum supply pressure: 30psi (207 kPa) Hot inlet temperature: 120°F-180°F (49°C-82°C) Cold inlet temperature: 39°F-80°F (3.8°C-27°C) Minimum inlet temperature differential: 5°F (2.8°C) Temperature range: 80°F-120°F (27°C-49°C) Maximum pressure: 150psi (10.3 bar) Minimum Flow: 0.25 gpm (1.0 l/m) *The wetted surface of this product contacted by consumable water contains less than one quarter of one percent (0.25%) of lead by weight.

Noryl® is a registered trademark of SABIC Innovative Plastics®. Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.

Basic Construction

Flow Capacity Ferrule Compression Nut Body

Plunger Locking Nut Temperature Adjustment Screw

kPa psi 620 90 551 80 482 70 413 60 345 50 276 40 207 30 138 20 69 10 0 0

0 0

2.00 3.00 4.00 gpm 7.8 11.4 15.2 lpm

1.00 3.8

Spring Thermostat Check Module Screen

A

Dimensions – Weights MODEL

SIZE

DIMENSIONS A

LFUSG-B-M2 LFUSG-B-SC-M2 LFUSG-B-QC-M2 LFUSG-B-QC-SC-M2

⁄ " Comp. 3⁄8" Comp. 3⁄8" Quick Connect 3⁄8" Quick Connect 38

B

WEIGHT C

D

in.

mm

in.

mm

in.

mm

in.

mm

lbs.

kgs.

33⁄16 33⁄16 31⁄4 31⁄4

81 81 83 83

33⁄8 33⁄8 4 4

85 85 102 102

113⁄16 113⁄16 21⁄4 21⁄4

47 47 57 57

11⁄2 11⁄2 11⁄2 11⁄2

38 38 38 38

.82 .82 1.05 1.05

.37 .37 .48 .48

B C

D

Typical Installations Two Handle Faucet Sensor Faucet

LFUSG-B-M2

NOTICE

Watts LFUSG-B-M2

This information is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product.

A Watts Water Technologies Company

ES-LFUSG-B-M2 1433

USA: Tel: (978) 689-6066 • Fax: (978) 975-8350 • Watts.com Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • Watts.ca Latin America: Tel: (52) 81-1001-8600 • Fax: (52) 81-8000-7091 • Watts.com

© 2014 Watts