Light Duty Commercial Atmospheric Vent High Input Gas

Report 0 Downloads 83 Views
Light Duty Commercial Atmospheric Vent High Input Gas Water Heater

Photo is of LG2100H853N FEATURING:

The Atmospheric Vent High Input Models Feature: ■ Bradford White ICON System™ (Excluding LG155H803N) —Intelligent gas control with proven millivolt powered technology and built-in piezo igniter. A standard, off-the-shelf thermopile converts heat energy from the pilot flame into electrical energy to operate the gas valve and microprocessor. No need for external electricity. -- Enhanced Performance—Proprietary algorithms provide enhanced First Hour Delivery ratings and tighter temperature differentials -- Advanced Temperature Control System—Microprocessor constantly monitors and controls burner operation to maintain consistent and accurate water temperature levels (up to 180°F). -- Intelligent Diagnostics—An exclusive green LED light prompts the installer during start-up and provides ten different diagnostic codes to assist in troubleshooting. -- Pilot On Indication—Flashing green LED provides positive indication that pilot is on. -- Separate Immersed Thermowell—High-strength advanced polymer composite thermowell provides isolation between electric temperature sensor and surrounding water. No need to drain the tank when removing gas valve. ■ Advanced ScreenLok® Technology Flame Arrestor Design—Flame arrestor is designed to prevent ignition of flammable vapor outside of the water heater (LG250H653N). ■ Resettable Thermal Switch—Proven and reliable bimetallic switch prevents burner and pilot operation in case of ongoing flammable vapor burn inside of the combustion chamber or restricted air flow (LG250H653N). ■ Factory-Installed Hydrojet 2 ™ Total Performance System—Cold water inlet sediment reducing device helps prevent sediment build-up in tank and increases first hour delivery of hot water. ■ Vitraglas® Lining—An exclusively engineered enamel formula that provides superior tank protection from the highly corrosive effects of hot water. This formula (Vitraglas®) is fused to the steel surface by firing at a temperature of over 1600°F (871°C). ■ Side Connections—3/4" (19mm) NPT tappings that allow easy connections for space heating applications (potable water only). ■ Insulation System—Non-CFC foam covers the sides and top of the tank, reducing heat loss. This results in less energy consumption, improved efficiencies, and jacket rigidity. ■ Pedestal Base (LG250H653N & LG275H763N). ■ Water Connections—Factory-installed true dielectric fittings extend water heater life and simplify water line connections. ■ Hand Hole Cleanout—Allows inspection of tank interior and facilitates the removal of sediment deposits (LG2100H853N models only). ■ Protective Magnesium Anode Rod. ■ 4" (107mm) “Snap Lock” Draft Diverter. ■ T&P Relief Valve—Installed. ■ Low Restrictive Brass Drain Valve—Durable tamper proof design. ■ Thermostatic Mixing Valve (ASSE Approved)—Included with LG155H803N only.

3 or 5-Year Limited Tank Warranties / 1-Year Limited Warranty on Component Parts. For more information on warranty, please visit www.bradfordwhite.com

For products installed in USA, Canada and Puerto Rico. Some states do not allow limitations on warranties. See complete copy of the warranty included with the heater. MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526; 6,684,821; 6,442,178; 7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984; 8,082,888; 5,988,117; 7,621,238; 7,650,859; 5,761,379; 7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 2,314,845; 2,504,824; 2,108,186; 2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105; 2,107,012. Vitraglas®, Hydrojet® and ScreenLok® are registered trademarks of Bradford White® Corporation.

1700-B-0617

Light Duty Commercial Atmospheric Vent Gas Water Heater Atmospheric Vent Models

Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed

NATURAL GAS AND LIQUID PROPANE GAS Model Number

LG250H653N LG155H803N LG275H763N LG2100H853N

Nominal Capacity

Recovery at DOE 100°F Rise* Rated 1st Storage Nat. Hour Uniform Nat. Nat. LP LP LP U.S. Imp. Volume BTU/Hr. BTU/Hr. Rating* Energy U.S. Imp. U.S. Imp. Gal. Gal. (Gal.) Input Input (Gal.) Factor GPH GPH GPH GPH 46 55 72 95

40 46 63 83

48 55 75 100

61,000 78,000 76,000 88,000

65,000 80,000 76,000 85,000

Model Number

A Floor to Flue Conn. in.

B Jacket Dia.

C Vent Size

in.

LG250H653N LG155H803N LG275H763N LG2100H853N

60 59 1/2 62 5/8 711/2

22 22 24 28 1/4

Model Number

A Floor to Flue Conn. mm.

B Jacket Dia. mm.

mm.

LG250H653N LG155H803N LG275H763N LG2100H853N

1524 1511 1591 1816

559 559 610 718

102 102 102 102

104 117 126 137

0.63 0.61 0.59 0.57

63 78 74 82

59 76 74 85

53 65 62 69

Nominal Capacity

Model Number

Liters LG250H653N LG155H803N LG275H763N LG2100H853N

49 63 62 71

174 208 273 360

M L Floor to Floor to Space Heating Space Heating Outlet Inlet in. in.

F Floor to Top of Heater in.

H C/L of Water Conn. in.

J Floor to Water Conn. in.

K Depth

in.

E Floor to Gas Conn. in.

4 4 4 4

49 15/16 49 7/8 51 7/8 59 5/16

13 1413/16 15 15 7/16

56 5/8 55 15/16 59 65 1/2

11 8 11 16

57 7/8 57 7/8 60 7/16 66 15/16

26 25 7/8 27 1/4 31 1/2

C Vent Size

D Floor to T&P Conn. mm.

E Floor to Gas Conn. mm.

F Floor to Top of Heater mm.

H C/L of Water Conn. mm.

J Floor to Water Conn. mm.

K Depth

1268 1267 1318 1507

330 376 381 392

1438 1421 1499 1664

279 203 279 406

1470 1470 1535 1700

660 657 692 800

B K

N

394 443 477 519

17.9 22.9 22.3 25.7

19.0 23.4 22.3 24.9

182 208 284 379

D Floor to T&P Conn. in.

Propane models feature a Titanium Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”. H For 5 year models, change suffix “3” to “5”. *Based on manufacturer’s rated recovery efficiency. LG2100H853N model features hand hole cleanout. K N N on the Uniform Energy Factor and First Hour Rating is based latest AHRI directory listings. NSF kits available.

Recovery at DOE 56°C Rise* 1st Rated LP Hour Uniform Nat. Storage Nat. LP kW Rating* Energy Liters/ Liters/ Volume kW (Liters) Input Input (Liters) Factor Hour Hour

in.

mm.

49 15/16 49 7/8 51 7/8 50 5/8

13 1/2 15 7/16 16 5/8 17 11/16

M L Floor to Floor to Space Heating Space Heating Outlet Inlet mm. mm. 1268 1267 1318 1286

343 392 422 449

N

B K

H

238 295 280 310

0.63 0.61 0.59 0.57

223 287 280 322

N NPT

Approx. Shipping Weight

in.

lbs.

3 4

/ 3/4 1 11/4

193 207 263 424

N NPT

Approx. Shipping Weight

mm.

kg.

19 19 25 32

88 94 119 192

N

N H

C

B

C

C

H

N

K

N

J

J

A J

A

A

F

F

F

B

D&M

D&M

D&M C

E

J

L

E

L

L

E

LG250H653N / LG275H763N LG155H803N LG2100H853N General: Meets NAECA Requirements (Applicable Models). A All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All gas connections are 1/2" (13mm). All D&M models design-certified by CSA International (formerly AGA/CGA), ANSI standard Z-21.10.3 and peak performance rated (RG250H6N = ANSI Z-21.10.1). Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. Suitable for Water (Potable) Heating and Space Heating. Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance.

F

E

L

For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative. Ambler, PA

Sales 800-523-2931 l Fax 215-641-1670 / Technical Support 800-334-3393 l Fax 269-795-1089 l Warranty 800-531-2111 l Fax 269-795-1089 International: Telephone 215-641-9400 l Telefax 215-641-9750 / www.bradfordwhite.com Sales / Technical Support 866-690-0961 / 905-238-0100 l Fax 905-238-0105 / www.bradfordwhite.com

1700-B-0617

©2017, Bradford White Corporation. All rights reserved.

Printed in U.S.A.