Lot 113 Warnervale Road

Report 0 Downloads 141 Views
All floor levels and other site specific details are design details only and are subject to change due to construction tolerances and site variables.

NOTE

IMPORTANT NOTE:

NBN estate - National Broadband Network. Please see the job supervisor to ensure the correct method of installation is implemented.

PLANS ARE SUBJECT TO CHANGE UPON COMPLETION OF PROPERTY BOUNDARY IDENTIFICATION SURVEY; CONTOUR SURVEY; SURVEYED LOCATION OF NEIGHBOURING DWELLINGS; AND ENVIRONMENTAL OVERLAYS/HAZARDS.

N

All Required Fencing to be Colorbond 1800H with access gates as shown. 19.00

19.50

20.00

20.50

21.00

21.50

Drop Edge Beam

2,770

Building Setback Line

3,160

900

31.50

POS>90m²

6,250

Concrete 125mm Min. thickness 20 MPA strength SL72 Mesh full extend of driveway 50mm Sand Bed

7m²

FILL

RL: 19.75 FFL: 20.05 900

3,000

65m² Coloured Concrete

31.50

Solar HWS AC Condenser

AC

4,950

Solar Panel

4,500

Proposed 1000mm High Timber Sleeper Retaining Wall if required NOT COMPLY NSW SITEWORKS(WE CAN'T BATTER)

19.50 20.00

Muster Point

21.00

20.50

21.50

Batter (with direction of fall)

1500

750

1 in 10 max

1 in 6 max

Varies

1300

1000

Boundary

19.00

Gas Cylinder

Water Line Sewer Line

6,180

Downpipe Elect Meter Box Gas Meter Box Int Fuse Box Gas HWS

1,125

15.41

5,800

CUT POS>86m²

15.41

6,000

6m²

1 in 4 max

1 in 6 max

1200

1500

Footpath Transition 1 in 8

1 in 40

1 in 8

Kerb

Road

1 in 25

Driveway Gradient 1500

Varies

1300

1000

1200

1500 Kerb

1 in 10 max

1 : 200

1 in 6 max

1 in 4 max

1 in 6 max

Boundary

Footpath Transition 1 in 8

1 in 40

Road

1 in 8

1 in 25

SP Licensed to Karan Sharma, [email protected] and downloaded on May 11, 2017

Ceiling GF Ceiling FF Ceiling SF Roof Pitch Roof Material Eave O'hang

2440

02 #

20.00° Colorbond 450

SITE DATE

DESCRIPTION

1 : 200

CLIENT SIGN.

DESIGN: Renee ( Dual Key )

AMENDMENTS

Parish: County: Map Ref: Local Authority: Wyong Shire Council Wind Rating: Area of Land: 485.4m2 Site coverage: 50% Job Number: 131856 Prelim Drawings Issue: 25/04/2017 Date:

CONSTRUCTION DET.

SITE ADDRESS

Lot 113 Warnervale Road . HAMLYN TERRACE . NSW . 2259

DRAWING PROPERTY DETAILS DESCRIPTION

Driveway Gradient CLIENT

1

Site Plan

750

SIGN: _______________ DATE: _____/____/_____

This plan may not be copied in part or in whole without the written permission of Impact Homes Pty Ltd. © Copyright 2014 Impact Homes Pty Ltd.

WINDOWS

Floor Areas

Unless dimensioned all windows are to be centred to the room in which they are located. IF a window is NOT centred OR dimensioned - ASK the job supervisor

18,610 10,380 160 70

Upgrades

3,000

160 70

General Flyscreens Flush panel internal doors Engineered Stone Benchtops Throughout 3 x AC Units Gas HWS

530 530 70 70 70

2,800

70

70

2,800

70

4,200

160

3,170

70

3,330

3,100

1,230

7,000

70 1,230

7,000

4,330

70

8,470

70

530 70 70

6,600

530 70 70

2,900

214.70 m² 27.57 m² 242.27 m²

7,000

70

4,900

Floor Area Outdoor Living

230

6,000

230

90

70

230

Ground Floor Plan

3,700 3,770

2,710 13,385

10,225 7,515 230 3,160

2,710

2,710 230

230 3,000

3,000 245

2,710 70 1,060 230 1,800 315

245 3,000

3,000 2,700

DP Elect &

230

1215 SW

HWS

2,900

Carpet

230

1215 SW

1809 SW DP

Bed 4

2,900

Robe

Carpet

1815 SW

Robe

Bed 3

Carpet

1400 WSD

Bed 2

70 1,130 70

1400 WSD

820

Gas MB

1,200

3,520

3,100

Porch

2,700

820

Tiles

1,345 70 1,345 140 930 70

820

Entry

230

AC

1815 SW

PTY

m/w

Kit

AC

DP

Robe

Tiles

Tiles

930

REF

dwp

2118 SGD

Elect CT Elect Ov

Meals

1800 WSD

AC

820

820

230

Tiles

930

300

820

Bed 1

Alfresco

1,800

960

720

1,050 90

230

Robe

1215 SW

Store

720

Tiles

1800 WSD

DP

Living

950 90

720

1,150

WC Ldy

Bath

1300 WSD

Linen

Ens

1500 WSD

0909 SW

DP

245

AC

1,560

1,870

2100 x 2400 Panel Lift

Garage

2100 x 2400 Panel Lift

Bath

70 930 70 1,130 70

Garage

Store

Linen

Tiles

1800 WSD

Drain for washing machine

1800 WSD

Living

70 930 140 1,300 70

1,870

Tiles

Tiles

720

2121 SGD

Alfresco

70 1,060 70 930 70

Elect & Gas MB

HWS

DP

Entry

Meals

820

900

3,350

REF

AC

820

2,620

Tiles

Porch

Tiles

2,150 90

230

Kit

Carpet

820

m/w

1806 SW

Robe

1800 WSD

Robe

1800 WSD

1218 SW

Elect CT Elect Ov

Bed 6

Carpet

3000L rainwater tank with rainbank system.

70 70 1,800

3,000 245

315 6,970

6,970

dwp

AC

230

70

70 2,800

3,930

1,800

2,800 70

3,930

2,960 285

315

1,500 70

140 1,430 1,800

3,000

230 1,060 70

230 2,400

Bed 5

90

530 70 70

4,900

70

70

4,900

70

230

2,930

2,500

1,900

530 70 930 70 70

6,000

7,800 530 70 70

3,000

3,770

230 1,300 70

70

3,000

1,700

530 70 70

230 1,300 3,000

230

16,300

1 : 100

NOTE

20,070

SP Licensed to Karan Sharma, [email protected] and downloaded on May 11, 2017

Ceiling GF Ceiling FF Ceiling SF Roof Pitch Roof Material Eave O'hang

2440

03 #

20.00° Colorbond 450

GROUND FLOOR DATE

DESCRIPTION

1 : 100

CLIENT SIGN.

DESIGN: Renee ( Dual Key )

AMENDMENTS

Parish: County: Map Ref: Local Authority: Wyong Shire Council Wind Rating: Area of Land: 485.4m2 Site coverage: 50% Job Number: 131856 Prelim Drawings Issue: 25/04/2017 Date:

CONSTRUCTION DET.

Lot 113 Warnervale Road . HAMLYN TERRACE . NSW . 2259

DRAWING PROPERTY DETAILS DESCRIPTION

CLIENT

PLANS ARE SUBJECT TO CHANGE UPON COMPLETION OF PROPERTY BOUNDARY IDENTIFICATION SURVEY; CONTOUR SURVEY; SURVEYED LOCATION OF NEIGHBOURING DWELLINGS; AND ENVIRONMENTAL OVERLAYS/HAZARDS.

SITE ADDRESS

1

1212 SW

Carpet

2,400

2,960 13,385 5,085 2,400

1218 SW

PTY

70

2,940

140

1,140 90

SIGN: _______________ DATE: _____/____/_____

This plan may not be copied in part or in whole without the written permission of Impact Homes Pty Ltd. © Copyright 2014 Impact Homes Pty Ltd.

NGL

PGL

Feature Colour Rendered Brick Proposed 1000mm High Timber Sleeper Retaining Wall if required

Axon

Elevation B 1 : 100

2,440

NGL

PGL Face Brick

86

Site Boundary

F.C. Sheeting Above All Brick Openings

Site Boundary

20.00°

2

Rendered Brick

2,440

Site Boundary

Site Boundary

Rendered Brick Above All Openings

1 : 100

20.00°

1

Elevation A

Feature Colour Rendered Brick

NOTE

SP Licensed to Karan Sharma, [email protected] and downloaded on May 11, 2017

Ceiling GF Ceiling FF Ceiling SF Roof Pitch Roof Material Eave O'hang

2440

04 #

20.00° Colorbond 450

ELEVATION 1 DATE

DESCRIPTION

1 : 100

CLIENT SIGN.

DESIGN: Renee ( Dual Key )

AMENDMENTS

Parish: County: Map Ref: Local Authority: Wyong Shire Council Wind Rating: Area of Land: 485.4m2 Site coverage: 50% Job Number: 131856 Prelim Drawings Issue: 25/04/2017 Date:

CONSTRUCTION DET.

Lot 113 Warnervale Road . HAMLYN TERRACE . NSW . 2259

DRAWING PROPERTY DETAILS DESCRIPTION

SITE ADDRESS

CLIENT

PLANS ARE SUBJECT TO CHANGE UPON COMPLETION OF PROPERTY BOUNDARY IDENTIFICATION SURVEY; CONTOUR SURVEY; SURVEYED LOCATION OF NEIGHBOURING DWELLINGS; AND ENVIRONMENTAL OVERLAYS/HAZARDS.

SIGN: _______________ DATE: _____/____/_____

This plan may not be copied in part or in whole without the written permission of Impact Homes Pty Ltd. © Copyright 2014 Impact Homes Pty Ltd.

1 : 100

F.C. Sheeting Above All Brick Openings

Site Boundary

Site Boundary

86

2,440

20.00°

1

Elevation C

PGL

Axon

Face Brick

NGL Porposed Alfresco Deck

Drop Edge Beam

20.00°

1 : 100

Site Boundary

F.C. Sheeting Above All Brick Openings

2,440

Site Boundary

2

Elevation D

NGL Rendered Brick

Face Brick

PGL

Axon Drop Edge Beam

NOTE

SP Licensed to Karan Sharma, [email protected] and downloaded on May 11, 2017

Ceiling GF Ceiling FF Ceiling SF Roof Pitch Roof Material Eave O'hang

2440

04a ELEVATION 2 #

20.00° Colorbond 450

DATE

DESCRIPTION

1 : 100

CLIENT SIGN.

DESIGN: Renee ( Dual Key )

AMENDMENTS

Parish: County: Map Ref: Local Authority: Wyong Shire Council Wind Rating: Area of Land: 485.4m2 Site coverage: 50% Job Number: 131856 Prelim Drawings Issue: 25/04/2017 Date:

CONSTRUCTION DET.

Lot 113 Warnervale Road . HAMLYN TERRACE . NSW . 2259

DRAWING PROPERTY DETAILS DESCRIPTION

SITE ADDRESS

CLIENT

PLANS ARE SUBJECT TO CHANGE UPON COMPLETION OF PROPERTY BOUNDARY IDENTIFICATION SURVEY; CONTOUR SURVEY; SURVEYED LOCATION OF NEIGHBOURING DWELLINGS; AND ENVIRONMENTAL OVERLAYS/HAZARDS.

SIGN: _______________ DATE: _____/____/_____

This plan may not be copied in part or in whole without the written permission of Impact Homes Pty Ltd. © Copyright 2014 Impact Homes Pty Ltd.

Electrical Legend

IMPORTANT NOTE:

NBN estate - National Broadband Network. Please see the job supervisor to ensure the correct method of installation is implemented.

Elect Meter Box Gas Meter Box Fuse Box (Int) Gas HWS Solar HWS AC AC

AC Condenser AC Head Unit Gas Cylinder

Solar Panel

Ceiling Fan

PTY dwp

m/w

Ceiling Fanlight (Fluro) 2W

REF

AC

Exhaust 3 in 1 Exhaust Fan Exhaust Fanlight

Elect & Gas MB

HWS

DP

2W

Smoke Detector R

Sgl Fluro Tube 18w Dbl Fluro Tube 36w Sgl Globe Fluro Oyster Dbl Globe Fluro Oyster

DP

AC

Downlight 240V (Fluro) Downlight 12V Low Voltage Downlight 12V Pendant Downlight Low V Fluro

R DP

Eyeball Light Wall Light Bunker Light (External) Flood Light (Eave)

AC

dwp

2W

Sensor

2W

REF

2W

AC

Flood Light (Wall)

Sensor Flood Light

AC

DP

AC

PTY

R

Single GPO Double GPO Roof Single GPO Waterproof Single GPO Waterproof Doube GPO

m/w

Batten Holder

DP

DP Elect &

HWS

Gas MB

Gas Outlet

$

TV Point Pay TV Point Phone Point Data Point

Isolation Switch

1

GF Electrical Plan 1 : 100

NOTE PLANS ARE SUBJECT TO CHANGE UPON COMPLETION OF PROPERTY BOUNDARY IDENTIFICATION SURVEY; CONTOUR SURVEY; SURVEYED LOCATION OF NEIGHBOURING DWELLINGS; AND ENVIRONMENTAL OVERLAYS/HAZARDS.

Lot 113 Warnervale Road . HAMLYN TERRACE . NSW . 2259

DRAWING PROPERTY DETAILS DESCRIPTION

SITE ADDRESS

CLIENT

Electrical points positions subject to construction constraints

Parish: County: Map Ref: Local Authority: Wyong Shire Council Wind Rating: Area of Land: 485.4m2 Site coverage: 50% Job Number: 131856 Prelim Drawings Issue: 25/04/2017 Date:

SP Licensed to Karan Sharma, [email protected] and downloaded on May 11, 2017

DESIGN: Renee ( Dual Key ) Ceiling GF Ceiling FF Ceiling SF Roof Pitch Roof Material Eave O'hang

2440

08 #

20.00° Colorbond 450

GF ELECTRICAL DATE

DESCRIPTION

1 : 100

CLIENT SIGN.

Dimmer Switch

AMENDMENTS

Door Chime Speaker

CONSTRUCTION DET.

Door Chime Button

SIGN: _______________ DATE: _____/____/_____

This plan may not be copied in part or in whole without the written permission of Impact Homes Pty Ltd. © Copyright 2014 Impact Homes Pty Ltd.

Recommend Documents